To address the problem of redundant long visual token sequences in volume image generation for 3D medical vision-language models, this paper proposes a unified training-free adaptive visual token redundancy compression framework named MedARC, which achieves token compression by fusing three complementary importance cues.
If a token compression scheme relies on a single importance signal alone, there is a risk of mistakenly removing clinically relevant regions or structurally distinctive regions.
No single criterion can simultaneously cover all the objectives that the compression process needs to account for: similarity-based criteria only capture feature redundancy between tokens and cannot judge the actual relevance of the corresponding regions to downstream clinical tasks; visual attention-based criteria mostly reflect encoder-level, query-independent intrinsic preferences and cannot adapt to the dynamically changing demands of inference tasks; and prompt-relevance-based criteria easily miss key medical regions of interest that have structural abnormalities but low model attention weights.
MedARC is a unified training-free adaptive visual token compression framework for 3D medical vision-language models. Without modifying the pretrained vision-language model, it can dynamically compress the long visual sequences generated by 3D medical vision-language models.
The core difference between this framework and existing compression schemes based on a single importance signal lies in that it estimates token importance by integrating three complementary, independent cues: the first is the self-attention output by the vision-language model's visual encoder, reflecting the model's intrinsic visual attention tendencies; the second is the similarity between projected visual tokens and text embeddings, which can identify regions relevant to the clinical query; the third is the deviation between local features of a frozen 3D visual foundation model and volume-level feature centroids, used to highlight anatomically distinctive regions. The resulting integrated importance distribution guides a saliency-aware merging strategy that preserves tokens with high informational value while consolidating redundant tokens.
MedARC's multi-cue scoring module integrates three complementary, independent importance signals: a visual attention signal, a visual-text similarity signal, and a visual foundation model saliency signal. The three signals are fused into a unified token importance score via weighted summation, computed as . The fine-grained visual knowledge provided by the visual foundation model is independent of the attention preferences of any specific vision-language model, and can supplement image detail information that was weakened during multimodal training, avoiding the judgment bias introduced by a single importance signal. Readers can refer to the figure that follows to fully understand the complete pipeline of visual token compression—from the medical image and input question up to before LLM decoding.
After obtaining the unified multi-cue importance score, MedARC performs a hierarchical token processing pipeline: high-importance visual tokens with top-ranked scores are directly retained in full, while the remaining visual tokens judged to be redundant undergo merging operations. All compression processing steps are completed before the large language model formally begins decoding.
The core implementation logic enabling this framework to run without fine-tuning is that all parameters of the target vision-language model and the 3DINO feature extractor remain frozen throughout the entire compression experiments. MedARC only accesses their intermediate features during inference to perform token importance estimation and redundant token merging, without introducing any additional training objectives. Across all experimental scenarios, the weight configuration is uniformly set to α=0.4, β=0.3, γ=0.3; the fixed parameter ρ in the adaptive compression pipeline is 0.05, and different compression levels are obtained solely by varying the threshold τ within the range from 0.6 to 0.9.
In the compression setting on the CT-RATE dataset, MedARC effectively preserves task-level clinical performance. At a visual token retention rate of 79.32%, its performance on the CT-RATE VQA task even exceeds that of the uncompressed baseline model, and even under the aggressive low retention setting of 52.66%, MedARC* maintains task performance close to the uncompressed model. You can refer to the multi-task output examples compared below to directly observe the output differences of different compression schemes across the three clinical tasks.
Under high-compression settings with similar compression rates, MedARC* delivers overall performance superior to existing compression baselines such as VisionZip and MedPruner on both CT-modality tasks, while its performance on the MR-RATE dataset is weaker than VisionZip, suggesting that clinical tasks in the MRI modality may require a larger visual token budget to maintain comparable performance.
The study conducted progressive ablation validation of the three complementary importance cues used by MedARC. Using only visual encoder attention as the scoring signal already yields a compression baseline with considerable effectiveness; adding the visual-text relevance cue leads to a clear improvement in VQA task performance, but brings a limited or even slight negative impact on the report generation task; finally, supplementing with the structural saliency cue from the frozen 3D visual foundation model effectively compensates for this trade-off, allowing the full model to achieve the best overall performance on both report generation and VQA tasks.
Under the experimental conditions completed in the paper, MedARC's effective performance range corresponds to a token compression rate of about 50%, and the ablation results verify that the three importance signals adopted by the framework are complementary. Performance at higher compression rates shows that MedARC's optimal token allocation budget has no universal fixed value and needs to be adapted according to the specific dataset and input modality used. The paper explicitly states that future work will extend MedARC to more types of models, medical institutions, modalities, and rare lesion scenarios, while further exploring technical directions related to risk-aware token allocation, robust saliency computation, and spatially constrained merging.