MCP
AA

A. Abusleme

4 papers in the library

Papers

4
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Daya BayJUNO collaborationsA. AbuslemeT. AdamS. AhmadS. AielloM. AkramN. AliF. P. AnG. P. AnQ. AnG. Andronico  +636
To maximize the light yield of the JUNO liquid scintillator, a 20 t sample was produced in a Daya Bay pilot plant and tested in an antineutrino detector. By varying PPO and bis-MSB concentrations across 12 steps, the detected photoelectrons indicated that, with purified solvent, bis-MSB need not exceed 4 mg/L. Using Daya Bay data to tune an optical model, the JUNO simulation determined the optimal composition: LAB solvent with 2.5 g/L PPO and 1–4 mg/L bis-MSB.
arXivarXiv · · July 1, 2020
0
109
Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up
H. AbramowiczA. AbuslemeK. AfanacievY. BenhammouL. BortkoO. BorysovM. BorysovaI. Bozovic-JelisavcicG. ChelkovW. DanilukD. DannheimK. Elsener  +48
From a test-beam study of a four-plane tungsten/silicon LumiCal prototype, the Molière radius of the electromagnetic shower was measured as $24.0 \pm 0.6\ (\text{stat.}) \pm 1.5\ (\text{syst.})$ mm using a parametrization of the shower shape. The data show very good agreement with a detailed Geant4 simulation, validating the multi-plane operation for a future $e^+e^-$ collider luminometer.
arXivarXiv · · May 10, 2017
0
Higgs Physics at the CLIC Electron-Positron Linear Collider
H. AbramowiczA. AbuslemeK. AfanacievN. Alipour TehraniC. BalázsY. BenhammouM. BenoitB. BilkiJ.-J. BlaisingM.J. BolandM. BoronatO. Borysov  +112
This paper presents the first comprehensive study of Higgs physics at the CLIC electron-positron collider across three energy stages ($\sqrt{s}=350$\,GeV, 1.4\,TeV, 3\,TeV). The initial stage enables precise, model-independent measurements of the Higgs production cross sections, total decay width $\Gamma_H$, and couplings via Higgsstrahlung and WW-fusion. At higher energies, large WW-fusion samples tighten coupling constraints, while $t\bar{t}H$ and $HH\nu\nu$ processes probe the top Yukawa and Higgs self-coupling. The expected precision and a global fit interpretation are reported.
arXivarXiv · · August 26, 2016
0
352
ECFA Detector R&D Panel, Review Report
FCAL CollaborationH. AbramowiczA. AbuslemeK. AfanacievJ. AguilarE. AlvarezP. BambadeL. BortkoI. Bozovic-JelisavcicE. CastroG. ChelkovC. Coca  +59
This report reviews the design of two special calorimeters for the very forward region of ILC or CLIC detectors. LumiCal measures low-angle Bhabha scattering with a precision better than $10^{-3}$ at ILC and $10^{-2}$ at CLIC, while BeamCal handles beamstrahlung remnants, providing fast luminosity estimates and beam parameters. Both improve electromagnetic hermeticity for new particle searches. R&D includes Monte Carlo studies, radiation-hard sensors, fast front-end electronics, and prototype tests with electron beams.
arXivarXiv · · November 18, 2014
0
1
Frequent collaborators
H. Abramowicz (3)
K. Afanaciev (3)
W. Daniluk (3)
K. Elsener (3)
E. Firu (3)
T. Fiutowski (3)
V. Ghenescu (3)
M. Idzik (3)
S. Kananov (3)
B. Krupa (3)
A. Levy (3)
I. Levy (3)