MCP
AA

A. Argan

70 papers in the library

Papers

30
The TES-based Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU: a large area silicon microcalorimeter for background particles detection
M. D'AndreaC. MacculiS. LottiL. PiroA. ArganG. MinerviniG. TorrioliF. ChiarelloL. Ferrari BarussoE. CelascoG. GallucciF. Gatti  +5
We present the latest single-pixel prototype of the Cryogenic AntiCoincidence detector (CryoAC) for the ATHENA X-IFU spectrometer, a TES-based microcalorimeter with a 1 cm² silicon absorber and an Ir/Au TES. Illuminated with ⁵⁵Fe and ²⁴¹Am sources, the detector response and on-chip heater calibration accuracy at low energy were studied. By operating it with a past-generation prototype, coincident detections characterized the laboratory background spectrum, disentangling primary cosmic muons from secondary photons and electrons.
arXivarXiv · · January 19, 2024
0
AGILE gamma-ray detection of the exceptional GRB 221009A
M. TavaniG. Piano…A. Argan
The AGILE satellite detected the long-duration gamma-ray burst GRB 221009A in the MeV–GeV range. Hard X-ray/MeV prompt emission lasted hundreds of seconds, with peak brightness between 200–300 seconds after trigger. Intense GeV emission persisted into the early afterglow up to 10,000 seconds. The key feature is the coexistence of time-variable MeV-peaked emission with hardening power-law GeV radiation during the prompt phase, suggesting distinct physical mechanisms at different locations.
arXivarXiv · · September 19, 2023
0
39
ATHENA X-IFU Demonstration Model: First joint operation of the main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)
M. D'AndreaK. RavensbergA. ArganD. BrienzaS. LottiC. MacculiG. MinerviniL. PiroG. TorrioliF. ChiarelloL. Ferrari BarussoM. Biasotti  +19
The X-IFU spectrometer on ATHENA combines a TES microcalorimeter array with a Cryogenic AntiCoincidence detector (CryoAC) to reduce particle background. In the first joint test of their Demonstration Models in a Frequency-Domain Multiplexing setup, both detectors operated correctly. Simultaneous detection of cosmic muons provided a preliminary demonstration of the anti-coincidence capability, a key step toward enabling mission science goals.
arXivarXiv · · June 30, 2022
0
On the High-Energy Spectral Component and Fine Time Structure of Terrestrial Gamma Ray Flashes
M. MarisaldiM. Galli…A. Argan
This paper resolves the controversy over a high-energy component in terrestrial gamma ray flashes (TGFs) extending to ~100 MeV. Using new AGILE satellite detections paired with lightning data, detailed Monte Carlo simulations, and refined instrument modeling, the authors show that the observed high-energy counts can be explained by a standard relativistic runaway electron avalanche (RREA) spectrum at the source if the TGF is sufficiently bright and short. No clear evidence is found for a fine-pulsed time structure at ~4 μs scales. The results also explain the TGF distribution in fluence-duration space and suggest the AGILE detection rate can nearly double.
arXivarXiv · · July 9, 2021
0
AGILESim: Monte Carlo simulation of the AGILE gamma-ray telescope
V. FiorettiA. BulgarelliM. TavaniS. SabatiniA. AboudanA. ArganP. W. CattaneoA. W. ChenI. DonnarummaF. LongoM. GalliA. Giuliani  +3
AGILESim is a Monte Carlo simulator of the AGILE/GRID gamma-ray telescope, built with the BoGEMMS architecture and Geant4. Its output is digitized and processed through the same onboard and on-ground reconstruction pipeline as real observations. The paper validates AGILESim by reproducing tracker conversion efficiency, charge readout distributions, and the Vela pulsar's point-spread function. The measured in-flight angular resolution (FWHM) for Vela-like sources is $2.0^{+0.2}_{-0.3}$ degrees (100–300 MeV) and $0.8^{+0.1}_{-0.1}$ degrees (300–1000 MeV), confirming the framework's applicability for future gamma-ray trackers.
arXivarXiv · · June 16, 2020
0
4
An X-Ray Burst from a Magnetar Enlightening the Mechanism of Fast Radio Bursts
M. TavaniC. CasentiniA. UrsiF. VerrecchiaA. AddisL. A. AntonelliA. ArganG. BarbielliniL. BaroncelliG. BernardiG. BianchiA. Bulgarelli  +51
On April 28, 2020, AGILE detected a hard X-ray burst (18–60 keV, lasting ~0.5 s, spectrally cutoff above 80 keV, isotropically emitted energy ~$10^{40}$ erg) from the Galactic magnetar SGR 1935+2154, coincident with a very bright FRB-like radio burst. This marks the first simultaneous detection of an X-ray burst and an FRB-like radio burst from a magnetar, showing that high-brightness temperature radio emission can coexist with spectrally-cutoff X-ray radiation, contrary to previous expectations. The event suggests that nearby repeating FRBs may be powered by magnetars with fields ~$10^{15}$ G.
arXivarXiv · · May 25, 2020
0
243
Gamma-Ray and X-Ray Observations of the Periodic-Repeater FRB 180916 During Active Phases
M. TavaniF. Verrecchia…A. Argan
AGILE and Swift X-ray and gamma-ray observations of the periodic repeater FRB 180916 during its active 5-day windows in 2020 found no simultaneous or extended emission. The cumulative X-ray (0.3–10 keV) flux upper limit of $5 \times 10^{-14} \rm\, erg\, cm^{-2} s^{-1}$ yields an isotropic luminosity limit $L_{X,UL} \sim 1.5 \times 10^{41} \rm\, erg\, s^{-1}$, the most stringent to date. This constrains a magnetar-like source with radius $R_m$, internal field $B_m$, and dissipation timescale $\tau_d$ to satisfy $R_{m,6}^3 B_{m,16}^2 \tau_{d,8}^{-1} \lesssim 1$.
arXivarXiv · · April 7, 2020
0
37
AGILE Observations of Two Repeating Fast Radio Bursts with Small Intrinsic Dispersion Measures
C. CasentiniF. VerrecchiaM. TavaniA. UrsiL.A. AntonelliA. ArganG. BarbielliniA. BulgarelliP. CaraveoM. CardilloP.W. CattaneoA. Chen  +21
The AGILE satellite observed two repeating fast radio bursts (FRBs 180916.J0158+65 and 181030.J1054+73) with small intrinsic dispersion measures, constraining their maximal distances. No prompt MeV–GeV emission was detected simultaneously with the bursts. For Source 1, the millisecond MeV-fluence upper limit is $F'_{\text{MeV}} = 10^{-8} \,\text{erg}\,\text{cm}^{-2}$, corresponding to isotropic energy $E_{\text{MeV,UL}} \simeq 2\times10^{46}\,\text{erg}$ at 150 Mpc. For Source 2 at ~100 kpc, the limit is $E_{\text{MeV,UL}} \simeq 10^{40}\,\text{erg}$. These constraints are significant for magnetar-like high-energy emission models.
arXivarXiv · · November 22, 2019
0
All-Sky-ASTROGAM: The MeV Gamma-Ray Companion to Multimessenger Astronomy
V. TatischeffA. De AngelisM. TavaniU. OberlackR. WalterG. AmbrosiA. ArganP. von BallmoosS. BrandtA. BulgarelliA. BykovS. Ciprini  +24
All-Sky-ASTROGAM is a proposed gamma-ray observatory for the 100 keV to few hundred MeV range, designed as a transient monitor with a nearly 4π sr field of view. It targets bright and intermediate-flux sources such as gamma-ray bursts and active galactic nuclei on timescales from seconds to months, operating in an L2 orbit from 2028. The mission aims to provide the MeV gamma-ray complement to the gravitational-wave and multi-messenger astronomy network.
arXivarXiv · · May 19, 2019
0
12
The Second AGILE Catalog of Gamma-Ray Sources
A. BulgarelliV. Fioretti…A. Argan
The Second AGILE-GRID Catalog (2AGL) presents 175 high-confidence $γ$-ray sources above 4$σ$ significance, based on 2.3 years of mission data. It includes improved calibrations, an updated Galactic diffuse model, and extended source searches. Among them, 121 sources have positional associations with known counterparts, including 62 blazars and 40 pulsars; 54 sources remain unidentified. The catalog also provides spectral properties and variability analysis.
arXivarXiv · · March 16, 2019
0
AGILE detection of gamma-ray sources coincident with cosmic neutrino events
F. LucarelliM. TavaniG. PianoA. BulgarelliI. DonnarummaF. VerrecchiaC. PittoriL. A. AntonelliA. ArganG. BarbielliniP. CaraveoM. Cardillo  +25
AGILE's gamma-ray imager detected three transient sources above 100 MeV that are spatially and temporally coincident with ten high-energy neutrino IceCube events. The chance probability of such associations is low, indicating possible counterparts. One source is linked to the BL Lac TXS 0506+056; the other two have no obvious known counterparts, leaving both Galactic and extragalactic origins open.
arXivarXiv · · November 19, 2018
0
32
The Wide Field Monitor onboard the eXTP mission
M. HernanzS. Brandt…A. Argan
This paper presents the design and expected performance of the Wide Field Monitor (WFM) for the eXTP mission, an X-ray timing and polarimetry observatory. The WFM, based on the LOFT mission design, consists of three pairs of coded-mask cameras using large-area silicon drift detectors. It covers the 2–50 keV energy range with a combined field of view of 90x180 degrees and achieves a source localization accuracy of ~1 arcmin. The paper details modifications from the earlier LOFT configuration and the anticipated instrument performance.
arXivarXiv · · July 24, 2018
0
24
Calibration of AGILE-GRID with on-ground data and Monte Carlo simulations
P.W. CattaneoA. RappoldiA. ArganG. BarbielliniF. BoffelliA. BulgarelliB. BuonomoM. CardilloA.W. ChenV. CoccoS. ColafrancescoF. D'Ammando  +32
The AGILE-GRID gamma-ray telescope (30 MeV–50 GeV) was calibrated before launch using a tagged gamma-ray beam of up to 500 MeV at the Frascati test facility. The beam data were compared to a GEANT3-based Monte Carlo simulation to measure angular and energy resolutions. The simulation matched the experimental resolutions well, validating its use for reliably predicting on-orbit performance.
arXivarXiv · · May 28, 2018
0
3
The e-ASTROGAM gamma-ray space observatory for the multimessenger astronomy of the 2030s
V. TatischeffA. De AngelisM. TavaniI. GrenierU. OberlackL. HanlonR. WalterA. ArganP. von BallmoosA. BulgarelliI. DonnarummaM. Hernanz  +65
e-ASTROGAM is a proposed space observatory with a gamma-ray telescope covering 0.15 MeV to 3 GeV, extending to 30 keV for gamma-ray bursts. Its advanced detector technology provides unprecedented sensitivity, angular and energy resolution, and polarimetric capability. In the MeV range, line sensitivity is one to two orders of magnitude better than prior instruments, enabling identification of supernova isotopes and study of relativistic outflows in powerful sources, positioning it as a key multimessenger facility for the 2030s.
arXivarXiv · · May 16, 2018
0
15
Science with e-ASTROGAM (A space mission for MeV-GeV gamma-ray astrophysics)
A. De AngelisV. TatischeffI. A. GrenierJ. McEneryM. MallamaciM. TavaniU. OberlackL. HanlonR. WalterA. ArganP. Von BallmoosA. Bulgarelli  +239
e-ASTROGAM is a proposed space mission for MeV–GeV gamma-ray astrophysics, using a silicon tracker, calorimeter, and anticoincidence system to cover 0.3 MeV–3 GeV (extendable to 30 keV). Its central contribution is an unprecedented combination of sensitivity, angular and energy resolution, and polarimetric capability in this energy range, improving line sensitivity by one to two orders of magnitude over previous instruments. This will enable breakthrough observations of non-thermal sources, relativistic outflows, and supernova nucleosynthesis, complementing major observatories across the electromagnetic and multi-messenger spectrum.
arXivarXiv · · November 3, 2017
0
267
AGILE Observations of the Gravitational-wave Source GW170817: Constraining Gamma-Ray Emission from a NS-NS Coalescence
F. VerrecchiaM. Tavani…A. Argan
The AGILE satellite observed the GW170817 localization region starting about 935 seconds after the LIGO-Virgo detection. No significant gamma-ray or X-ray emission was detected across repeated exposures spanning minutes, hours, and days before and after the event. These non-detections constrain the high-energy emission from the neutron star merger, excluding with high confidence a magnetar-like object with a magnetic field of $10^{15}\,\mathrm{G}$.
arXivarXiv · · October 16, 2017
0
The THESEUS space mission concept: science case, design and expected performances
L. AmatiP. O'Brien…A. Argan
The THESEUS space mission concept uses Gamma-Ray Bursts as probes of the early Universe, combining a wide-field (over 1 sr) X-ray/gamma-ray transient detector with a 0.7 m IR telescope for on-board prompt follow-up. This design enables arcmin localization, 0.3 keV–MeV coverage, and identification of electromagnetic counterparts to gravitational-wave sources for the multi-messenger era. The mission addresses cosmology topics such as high-redshift star formation, Pop III stars, and re-ionization, and will synergize with next-generation observatories.
arXivarXiv · · October 12, 2017
0
314
AGILE Observations of the Gravitational Wave Source GW170104
F. VerrecchiaM. TavaniA. UrsiA. ArganC. PittoriI. DonnarummaA. BulgarelliF. FuschinoC. LabantiM. MarisaldiY. EvangelistaG. Minervini  +27
AGILE observations of the GW170104 localization region found no significant gamma-ray emission above 50 MeV. A refined analysis of the MCAL omnidirectional detector (0.4–100 MeV) revealed a weak event, E2, with a signal-to-noise ratio of $4.4\,\sigma$, lasting about 32 ms and occurring $0.46\pm0.05\,\mathrm{s}$ before the LVC detection time $T_0$. Its post-trial significance for temporal coincidence with GW170104 is between $2.4\,\sigma$ and $2.7\,\sigma$. If associated, E2 would indicate MeV-band emission from a short burst preceding the coalescence by 0.46 s, releasing about $10^{-7}$ of the system's rest-mass energy.
arXivarXiv · · May 31, 2017
0
47
The e-ASTROGAM gamma-ray space mission
V. TatischeffM. TavaniP. von BallmoosL. HanlonU. OberlackA. AboudanA. ArganD. BernardA. BrognaA. BulgarelliA. BykovR. Campana  +39
The e-ASTROGAM is a proposed M5 Medium-size ESA mission for gamma-ray astrophysics, achieving unprecedented sensitivity in the 0.2–100 MeV range and extending to GeV energies with groundbreaking polarization capability. It substantially improves on COMPTEL and Fermi in the MeV–GeV band, targeting extreme particle accelerators, Galactic center mysteries, and nucleosynthesis. The telescope optimizes simultaneous detection of Compton and pair-production events, leveraging high-technology-readiness subsystems and innovative detectors.
arXivarXiv · · August 12, 2016
0
75
Enhanced detection of terrestrial gamma-ray flashes by AGILE
M. MarisaldiA. ArganA. UrsiT. GjestelandF. FuschinoC. LabantiM. GalliM. TavaniC. PittoriF. VerrecchiaF. D'AmicoN. Østgaard  +12
In March 2015, the AGILE satellite's onboard software was modified to disable the anticoincidence shield veto for the minicalorimeter, which had been causing excessive dead time. This change increased the detection rate of terrestrial gamma-ray flashes (TGFs) by an order of magnitude. Most new events are short (< 100 $\mu$s), and some coincide with lightning sferics recorded by WWLLN. The resulting detection rate density (TGFs/km$^2$/year) is the highest achieved to date, enabling improved correlation studies with lightning and atmospheric parameters along the equatorial region.
arXivarXiv · · May 25, 2016
0
57
AGILE Observations of the Gravitational Wave Event GW150914
M. TavaniC. PittoriF. VerrecchiaA. BulgarelliA. GiulianiI. DonnarummaA. ArganA. TroisF. LucarelliM. MarisaldiE. Del MonteY. Evangelista  +26
AGILE, operating in spinning mode, searched for a gamma-ray counterpart of the LIGO gravitational wave event GW150914. The instrument covered about 65% of the localization region during 100-second intervals centered at -100 s and +300 s from the event time. No significant signal was detected; a 2-sigma flux upper limit of $1.9 \times 10^{-8} \rm \, erg \, cm^{-2} \, s^{-1}$ (50 MeV–10 GeV) was obtained about 300 s after the event, the fastest such measurement for GW150914. The weak transient reported by Fermi-GBM was not confirmed. No precursor or delayed emission was found over timescales from minutes to days.
arXivarXiv · · April 4, 2016
0
70
On the Angular Resolution of the AGILE gamma-ray imaging detector
S. SabatiniI. DonnarummaM. TavaniA. TroisA. BulgarelliA. ArganG. BarbielliniP.W. CattaneoA. ChenE. Del MonteV. FiorettiF. Gianotti  +7
We present a study of the angular resolution of the AGILE gamma-ray imaging detector (GRID), operational since April 2007 and sensitive from 50 MeV to 10 GeV. Using Monte Carlo simulations and in-flight Crab data, we show that for a Crab-like $E^{-2}$ spectrum, the angular resolution is stable across a large field of view: full width at half maximum (FWHM) of ~4° at 100 MeV, ~0.8° at 1 GeV, and ~0.9° integrating from 100 MeV to tens of GeV, with a flat response up to 30° off-axis. Despite different detector configurations, the angular resolution of AGILE-GRID and Fermi-LAT is very similar between 100 MeV and a few GeV.
arXivarXiv · · July 6, 2015
0
26
Study of the Gamma-ray performance of the GAMMA-400 Calorimeter
P.CumaniA.M. GalperV. BonviciniN.P. TopchievO. AdrianiR.L. AptekarA. ArganI.V. ArkhangelskajaA.I. ArkhangelskiyL. BergstromE. BertiG. Bigongiari  +64
The GAMMA-400 space mission studies gamma rays from ~100 MeV to a few TeV and cosmic rays. Using a Geant4-based simulation, the paper outlines the gamma-ray reconstruction pipeline in the pre-shower and calorimeter, and reports the most updated mission performance, including point-spread function and effective area.
arXivarXiv · · February 11, 2015
0
0
The Large Observatory For x-ray Timing
M. FerociJ.W. den Herder…A. Argan
The Large Observatory For x-ray Timing (LOFT), studied within ESA's M3 Cosmic Vision framework, was designed to probe matter under extreme gravity and density by combining a 10 m² effective-area Large Area Detector (2–30 keV, 240 eV resolution) with a Wide Field Monitor (2–50 keV, 1 arcmin localization). Its unprecedented timing and spectral capabilities would have enabled studies of strong-field gravity near black holes and neutron stars, as well as supra-nuclear densities in neutron-star interiors. The paper reports the mission status at the end of Phase A.
arXivarXiv · · August 27, 2014
0
352
The digital data processing concepts of the LOFT mission
C. TenzerA. ArganA. CrosY. FavreM. GschwenderF. JetterA. SantangeloS. SchanneP. SmithS. SuchyP. UterD. Walton  +1
The paper describes the on-board data handling concepts developed for the LOFT mission, which had two instruments: the Large Area Detector (LAD) and the Wide Field Monitor (WFM). The central contribution is the design of real-time data processing, filtering, and compression algorithms that handle the LAD's enormous data rates from observing bright X-ray sources, while the WFM's processing focused on locating photon interactions and deconvolving detector images to obtain sky coordinates of transient sources.
arXivarXiv · · August 27, 2014
0
3
Optimisation of the design for the LOFT Large Area Detector Module
D. WaltonB. WinterS. ZaneT. KennedyA.J. CokerM. FerociJ.-W. Den HerderA. ArganP. AzzarelloD. BarretL. BradleyF. Cadoux  +16
This paper summarizes the optimized design of the Large Area Detector (LAD) Module for the LOFT X-ray timing observatory, a 10 m²-class instrument (2–30 keV) capable of millisecond timing of compact objects. The module is the building block of the LAD; the paper presents the rationale for the module concept, its key characteristics, and the trade-offs and optimizations that produced the final design developed during ESA's assessment phase.
arXivarXiv · · August 27, 2014
0
The Large Area Detector of LOFT: the Large Observatory for X-ray Timing
S. ZaneD. WaltonT. KennedyM. FerociJ.-W. Den HerderM. AhangarianabhariA. ArganP. AzzarelloG. BaldazziM. BarberaD. BarretG. Bertuccio  +47
The Large Area Detector (LAD) is a 10 m²-class instrument for the 2-30 keV band, designed to achieve millisecond X-ray timing for probing matter near black holes and neutron stars. It was the pointed instrument of the proposed LOFT mission, an ESA M3 candidate studied through an assessment phase. Although not selected for launch, the LAD design was matured and well documented, ready for future re-proposal.
arXivarXiv · · August 27, 2014
1
50
The design of the wide field monitor for LOFT
S. BrandtM. HernanzL. AlvarezA. ArganB. ArtiguesP. AzzarelloD. BarretE. BozzoBudtz-JørgensenR. CampanaA. CrosE. del Monte  +32
The paper describes the Wide Field Monitor (WFM) for the LOFT mission, designed to detect transient X-ray sources in the 2-50 keV range for follow-up by the Large Area Detector. The WFM uses coded masks and 10 independent cameras arranged in 5 pairs, achieving an instantaneous sky coverage of over 1/3 and energy resolution better than 500 eV, enabling long-term variability studies of X-ray sources. Its compact modular design makes it adaptable for other missions.
arXivarXiv · · August 27, 2014
0
The LOFT Ground Segment
E. BozzoA. AntonelliA. ArganD. BarretP. BinkoS. BrandtE. CavazzutiT. CourvoisierJ.W. den HerderM. FerociC. FerrignoP. Giommi  +18
This paper describes the planned ground segment (GS) for LOFT, an ESA M3 mission candidate. The GS was designed to handle ~100 GB of daily science data from two instruments: the pointed Large Area Detector (LAD) and the all-sky Wide Field Monitor (WFM), whose data were to be made public immediately. A VHF-based burst alert system would broadcast on-board triggers for impulsive events. The paper summarises the GS organisation, data flow, archiving, and distribution as established in the mission Yellow Book.
arXivarXiv · · August 27, 2014
0
2
The Agile Alert System For Gamma-Ray Transients
A. BulgarelliM. Trifoglio…A. Argan
The AGILE Gamma-Ray Alert System automatically detects gamma-ray transients in the 30 MeV–30 GeV band of the GRID instrument. An alert pipeline analyzes data at each orbital downlink, and when flux thresholds are exceeded, alerts are generated as SMS, email, or push notifications within two to three hours—an unprecedented reaction time in gamma-ray astrophysics. The system includes a new blind-search algorithm, cross-checks between two pipelines, manual analysis, and likelihood-ratio tests to evaluate post-trial statistical significance.
arXivarXiv · · January 15, 2014
0
44
Frequent collaborators
M. Tavani (55)
A. Bulgarelli (55)
F. Longo (55)
I. Donnarumma (54)
C. Pittori (52)
M. Marisaldi (51)
A. Trois (50)
M. Feroci (50)
C. Labanti (50)
F. Verrecchia (49)
S. Vercellone (48)
E. Del Monte (48)