MCP
AA

A. Askin

9 papers in the library

Papers

9
The XENON100 Dark Matter Experiment
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensE. BrownJ. M. R. CardosoB. ChoiD. ClineS. Fattori  +24
The XENON100 experiment targets WIMP dark matter via nuclear recoils in a 62 kg liquid xenon (LXe) time projection chamber (TPC), surrounded by a 99 kg LXe veto. Both volumes are instrumented with photomultiplier tubes and housed in a low-radioactivity stainless steel vessel shielded by passive materials. Installed underground at LNGS (Italy), its design goal is a spin-independent WIMP-nucleon cross-section sensitivity of $\sigma = 2 \times 10^{-45} \text{ cm}^2$ for a 100 GeV/$c^2$ WIMP.
arXivarXiv · · July 11, 2011
0
567
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensK. BokelohE. BrownT. BruchG. BrunoJ. M. R. Cardoso  +43
Using 100.9 live-days of XENON100 data, this paper reports limits on the WIMP-nucleon cross section for inelastic dark matter. With three observed events in the signal region (expected background $1.8 \pm 0.6$), the results rule out, at 90% confidence level, the inelastic dark matter scattering off iodine as an explanation for the DAMA/LIBRA modulation.
arXivarXiv · · April 15, 2011
0
102
Dark Matter Results from 100 Live Days of XENON100 Data
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensK. BokelohE. BrownT. BruchG. BrunoJ. M. R. Cardoso  +43
The XENON100 experiment, a two-phase time projection chamber with a 62 kg liquid xenon target installed underground, found no evidence for dark matter in 100.9 live days of data. Three candidate events were observed in a pre-defined signal region against an expected background of $1.8 \pm 0.6$ events. This null result sets the most stringent limit on dark matter interactions at the time, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above $7.0 \times 10^{-45}$ cm$^2$ for a WIMP mass of 50 GeV/$c^2$ at 90% confidence level.
arXivarXiv · · April 13, 2011
0
1k+
Material screening and selection for XENON100
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensK. BokelohE. BrownJ.M.R. CardosoB. ChoiD. Cline  +29
This paper reports the extensive material screening campaign for the XENON100 dark matter experiment, operated underground at LNGS, Italy. Using ultra-sensitive HPGe gamma spectrometry and mass spectrometry for low-mass plastics, the authors measured radioactive contaminations of all candidate materials. Detailed tables of contamination levels are presented, with implications for the experiment's background and construction decisions.
arXivarXiv · · March 30, 2011
0
172
Gator: a low-background counting facility at the Gran Sasso Underground Laboratory
L. BaudisA. D. FerellaA. AskinJ. AngleE. AprileT. BruchA.KishM. LaubensteinA. ManalaysayT. Marrodan UndagoitiaM. Schumann
The Gator facility, a low-background germanium spectrometer installed at the Gran Sasso Underground Laboratory (LNGS), achieves an integrated background rate of approximately 0.16 events/min in the 100–2700 keV energy range, comparable to the world's most sensitive germanium detectors. The paper describes its ultra-low-background shield, calibration and efficiency measurements, background sources, and two independent analysis methods compared via sample measurements. Gator is used for material screening for the XENON, GERDA, and future DARWIN experiments.
arXivarXiv · · March 10, 2011
0
Likelihood Approach to the First Dark Matter Results from XENON100
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensK. BokelohE. BrownT. BruchJ. M. R. CardosoB. Choi  +34
This paper presents a statistical model for direct Dark Matter detection experiments using the Profile Likelihood ratio as a frequentist test statistic. The model incorporates calibration data as control measurements and includes systematic uncertainties from detectors and astrophysics. Applied to XENON100's first data release, it extracts additional information and sets a single limit on the spin-independent elastic WIMP-nucleon scattering cross-section, with a minimum of $2.4 \times 10^{-44} \, \mathrm{cm}^2$ for a WIMP mass of $50 \, \mathrm{GeV}/c^2$, including all relevant uncertainties.
arXivarXiv · · March 1, 2011
0
213
Study of the electromagnetic background in the XENON100 experiment
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensK. BokelohE. BrownJ.M.R. CardosoB. ChoiD. Cline  +33
The XENON100 experiment, located at LNGS, aims to directly detect dark matter WIMPs. This paper presents a comprehensive study of the predicted electronic recoil background from radioactive decays. Using GEANT4 Monte Carlo simulations with detailed detector geometry and measured radioactivity of all components, the background in the WIMP-search energy range (0-100 keV) within the 30 kg fiducial mass is predicted to be less than $10^{-2}$ events/(kg-day-keV). This prediction, consistent with the design goal, agrees very well with commissioning data from Fall 2009.
arXivarXiv · · January 20, 2011
0
150
First Dark Matter Results from the XENON100 Experiment
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensE. BrownJ. M. R. CardosoB. ChoiD. B. ClineS. Fattori  +27
The XENON100 experiment, using 62 kg of liquid xenon in a dual-phase time projection chamber, reports its first dark matter search results from 11.17 live days of data. With a 40 kg fiducial target and no events observed in the predefined signal region, it excludes spin-independent WIMP-nucleon elastic scattering cross-sections above $3.4 \times 10^{-44}$ cm$^2$ for 55 GeV/c$^2$ WIMPs at 90% confidence level. For WIMP masses below 20 GeV/c$^2$, this constraint challenges the interpretation of CoGeNT and DAMA signals as spin-independent, elastic light WIMP interactions.
arXivarXiv · · May 3, 2010
0
571
Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr
A. ManalaysayT. Marrodan UndagoitiaA. AskinL. BaudisA. BehrensA. D. FerellaA. KishO. LebedaR. SantorelliD. VenosA. Vollhardt
The authors introduce a calibration method for liquid xenon (LXe) detectors using the short-lived noble gas $^{83\text{m}}$Kr, which disperses uniformly throughout the detector. Its two transitions at 9.4 and 32.1 keV enable background-free decay identification. Applying this method, they find that LXe light yield increases at lower energies while electric field quenching decreases. Any introduced long-lived backgrounds would be below $67\times10^{-6}$ events/kg/day for next-generation dark matter searches.
arXivarXiv · · August 5, 2009
0
Frequent collaborators
L. Baudis (9)
E. Aprile (8)
A. Behrens (8)
A. Kish (8)
R. Santorelli (8)
M. Schumann (8)
XENON100 Collaboration (7)
K. Arisaka (7)
F. Arneodo (7)
E. Brown (7)
B. Choi (7)
S. Fattori (7)