MCP
AB

A. Baù

21 papers in the library

Papers

21
QUBIC IV: Performance of TES Bolometers and Readout Electronics
M. PiatG. Stankowiak…A. Bau
QUBIC IV reports the performance of its 256 NbSi transition edge sensor (TES) bolometers and time-domain multiplexing readout. The low-noise amplifier achieved 0.3 nV/Hz$^{-0.5}$ white noise, and about 80% of detectors operated within specifications. The instrument noise equivalent power was about 2×10$^{-16}$ W/Hz$^{-0.5}$, sufficient for demonstrating bolometric interferometry, though limited by microphonics and noise aliasing.
arXivarXiv · · January 17, 2021
0
36
QUBIC I: Overview and ScienceProgram
J.-Ch. HamiltonL. Mousset…A. Baù
QUBIC is a novel bolometric interferometer for CMB B-mode polarization that combines the systematic-error control of interferometry with the wide-band sensitivity of bolometers. Its synthesized beam's frequency-dependent shape enables multi-sub-band polarization mapping within the 150 and 220 GHz bands, aiding foreground removal. Simulations for three years of observation from Argentina, assuming perfect foreground subtraction and stable atmosphere, yield a statistical sensitivity to the effective tensor-to-scalar ratio of $\sigma(r)=0.015$.
arXivarXiv · · November 4, 2020
0
QUBIC II: Spectro-Polarimetry with Bolometric Interferometry
L. MoussetM.M. Gamboa Lerena…A. Baù
This paper reports that bolometric interferometry enables spectral imaging, allowing a single instrument to reconstruct sky maps in multiple sub-bands from a wide frequency band. Using the QUBIC instrument, the authors demonstrate point-source reconstruction and Galactic dust mapping, characterize the frequency-dependent point spread function, and study noise correlations between sub-bands via simulations. They conclude that with QUBIC, spectral imaging performance is nearly optimal for up to five sub-bands, offering a method to separate CMB B-mode polarization from astrophysical foregrounds.
arXivarXiv · · October 28, 2020
0
0
The large scale polarization explorer (LSPE) for CMB measurements: performance forecast
LSPE collaborationG. AddamoP. A. R. AdeC. BaccigalupiA. M. BaldiniP. M. BattagliaE. S. BattistelliA. BaùP. de BernardisM. BersanelliM. BiasottiA. Boscaleri  +93
LSPE, combining the ground-based Strip telescope and the balloon-borne SWIPE instrument, will observe CMB polarization from the Northern Hemisphere. Its design targets a sensitivity to the tensor-to-scalar ratio of $\sigma_r<0.01$, enabling competitive constraints on inflationary B-modes. The forecast accounts for scanning strategy, component separation, foreground residuals, and systematic effects, demonstrating that the two-instrument configuration can reach the target sensitivity despite partial sky coverage.
arXivarXiv · · August 25, 2020
0
88
QUBIC V: Cryogenic system design and performance
S. MasiE.S. Battistelli…A. Baù
The QUBIC experiment's cryogenic system, designed for long-duration CMB polarization measurements, is presented. The system uses two pulse-tube refrigerators to cool a ~1 m³, ~165 kg instrument to ~3K. A ⁴He evaporator cools the beam combiner to ~1K, and a ³He evaporator cools the detector arrays to ~0.33K. The system operated stably for over six months, and tilting from 20° to 90° elevation caused no significant temperature changes, confirming readiness for deployment.
arXivarXiv · · August 24, 2020
0
29
QUBIC VI: cryogenic half wave plate rotator, design and performances
G. D&#39;AlessandroL. Mele…A. Baù
The QUBIC Stokes polarimeter rotates a half-wave plate (HWP) at cryogenic temperature to modulate polarization while minimizing spurious signals from optical element emissivity. Its rotation is driven by an external stepper motor to avoid thermal load at low temperature. Tests show positioning precision below 0.1° and an extra power load of only a few mK on the ~8 K cryogenic stage.
arXivarXiv · · August 24, 2020
0
QUBIC III: Laboratory Characterization
S.A. TorchinskyJ.-Ch. Hamilton…A. Baù
The QUBIC Technological Demonstrator successfully validates bolometric interferometry through laboratory characterization. A prototype scanned a far-field modulated millimeter-wave source to produce synthesized beam maps, achieving measured beams matching theoretical simulations and enabling spectro-imaging. Polarization performance showed less than 0.5% cross-polarization rejection. The instrument is now ready for deployment in Argentina.
arXivarXiv · · August 23, 2020
0
28
QUBIC VIII: Optical design and performance
C. O&#39;SullivanM. De Petris…A. Bau
QUBIC uses bolometric interferometry to detect CMB B-mode polarisation around the recombination peak. A cold reflective combiner overlays beams from 400 feedhorns onto two focal planes, combining imager sensitivity with interferometer systematic-error control. A fixed groundshield and a moving forebaffle limit local contamination. The paper presents the optics modelling, design, manufacturing, and preliminary measurements.
arXivarXiv · · August 23, 2020
0
36
Progress report on the Large Scale Polarization Explorer
L. LamagnaG. AddamoP. A. R. AdeC. BaccigalupiA. M. BaldiniP. M. BattagliaE. BattistelliA. BaùM. BersanelliM. BiasottiC. BoragnoA. Boscaleri  +87
The Large Scale Polarization Explorer (LSPE) is a cosmology program aiming to constrain the tensor-to-scalar ratio $r$ down to $10^{-2}$ by measuring B-modes in the cosmic microwave background polarization. It combines two instruments: LSPE/STRIP, a ground-based coherent receiver array for characterizing low-frequency galactic polarized signals, and LSPE/SWIPE, a balloon-borne bolometric polarimeter with 330 multi-moded detectors targeting CMB polarization at 150 GHz and galactic dust emission above 200 GHz. This report covers the pre-commissioning phase of STRIP and the characterization of SWIPE's key subsystems before integration.
arXivarXiv · · May 3, 2020
0
30
QUBIC: the Q & U Bolometric Interferometer for Cosmology
E.S. BattistelliP. AdeJ.G. AlberroA. AlmelaG. AmicoL. H. ArnaldiD. AugusteJ. AumontS. AzzoniS. BanfiP. BattagliaA. Baù  +127
QUBIC combines Transition Edge Sensor bolometers with interferometric techniques to measure the faint polarization signal of the cosmic microwave background left by inflation. This hybrid design achieves the sensitivity of cryogenic detectors and the systematic-error control of an interferometer, distinguishing it from classical imaging CMB experiments. The instrument, demonstrated in the lab, will be deployed in Argentina at the end of 2019.
arXivarXiv · · January 28, 2020
0
21
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
M. PiatB. Bélier…A. Baù
QUBIC is a ground-based CMB experiment that measures polarized fluctuations using bolometric interferometry, combining the systematic-immunity of an interferometer with the sensitivity of cryogenic detectors. Its detection chain uses 2048 NbSi Transition Edge Sensors (TESs) cooled to 350 mK, read out via time-domain multiplexing (MUX factor 128) with SQUIDs at 1 K and a SiGe ASIC at 60 K. Characterization results from a reduced detector setup are presented, focusing on the detectors and readout system.
arXivarXiv · · November 27, 2019
0
The STRIP instrument of the Large Scale Polarization Explorer: microwave eyes to map the Galactic polarized foregrounds
C. FranceschetS. RealiniA. MennellaG. AddamoA. BaùP. M. BattagliaM. BersanelliB. CaccianigaS. CaprioliF. CavaliereK. A. ClearyF. Cuttaia  +39
The STRIP instrument, part of the LSPE experiment, uses an array of forty-nine coherent polarimeters at 43 GHz coupled to a 1.5 m rotating crossed-Dragone telescope to measure approximately 25% of the Northern sky from Tenerife. Its goal is to detect B-modes in the CMB polarization by characterizing Galactic polarized foregrounds. A six-element 95 GHz channel monitors the atmosphere. The hardware has been tested at sub-system level, with system-level characterization starting in July 2018 and a two-year observation campaign planned.
arXivarXiv · · December 10, 2018
0
12
Thermal architecture for the QUBIC cryogenic receiver
A.J. MayC. Chapron…A. Bau
The QUBIC cryogenic receiver uses a four-stage thermal architecture (40 K, 4 K, 1 K, 350 mK) driven by two pulse tube coolers, a novel 4He sorption cooler, and a double-stage 3He/4He sorption cooler. This design enables bolometric interferometry for measuring the B-mode polarization of the cosmic microwave background. The paper presents the thermal and mechanical design, modeling, and laboratory cryogenic testing of the receiver.
arXivarXiv · · November 6, 2018
0
11
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background
A. MennellaP.A.R. AdeJ. AumontS. BanfiP. BattagliaE.S. BattistelliA. BaùB. BélierD.BennettL. BergéJ.Ph. BernardM. Bersanelli  +96
QUBIC is a novel instrument that combines the sensitivity of bolometric detectors with the systematic-effects control of interferometers to detect polarized signals from the cosmic microwave background, specifically primordial gravitational waves. Its key contribution is "self-calibration", a technique intrinsic to its interferometric design that removes instrumental effects from the measured data. The first module, a dual-band instrument at 150 GHz and 220 GHz, was set for deployment in Argentina in fall 2018.
arXivarXiv · · January 11, 2018
0
3
QUBIC Technical Design Report
J. AumontS. BanfiP. BattagliaE.S. BattistelliA. BaùB. BélierD.BennettL. BergéJ.Ph. BernardM. BersanelliM.A. Bigot-SazyN. Bleurvacq  +87
The QUBIC instrument is designed to measure CMB B-mode polarization anisotropies at multipoles 30–200. It is a bolometric interferometer that combines background-limited Transition-Edge-Sensor sensitivity with systematic control via interference fringe patterns, operating at two frequencies to separate polarized foregrounds from primordial B-mode signal. This Technical Design Report provides a detailed description of its characteristics.
arXivarXiv · · September 14, 2016
0
15
An improved upper limit to the CMB circular polarization at large angular scales
R. MaininiD. MinelliM. GervasiG. BoellaG. SironiA. Bau&#39;S. BanfiA. PasseriniA. De LuciaF. Cavaliere
Using the MIPOL polarimeter at the Testa Grigia Observatory, the authors report improved 95% confidence upper limits on the CMB circular polarization (V Stokes parameter) at large angular scales. At angular scales between 8° and 24°, the limits range from 5.0×10^{-4} to 0.7×10^{-4}, improving by an order of magnitude over previous limits. These results are still far from the expected nK-level signals but represent the best constraints at these scales.
arXivarXiv · · July 23, 2013
0
Latest Progress on the QUBIC Instrument
A. GhribiJ. AumontE. S. BattistelliA. BauL. BergéJ-Ph. BernardM. BersanelliM-A. Bigot-SazyG. BordierE. T. BunnF. CavaliereP. Chanial  +51
QUBIC is a hybrid instrument combining classical imaging and interferometry to achieve high sensitivity and systematic control. Its primary goal is detecting primordial gravitational wave imprints on the Cosmic Microwave Background, which would confirm inflation. This paper presents the latest advances in the architecture and subsystems of the first QUBIC module, scheduled for deployment at Dome Charlie Concordia base in Antarctica in 2015.
arXivarXiv · · July 22, 2013
0
18
A coherent polarimeter array for the Large Scale Polarization Explorer balloon experiment
M. BersanelliA. MennellaG. MorganteM. ZannoniG. AddamoA. BaschirottoP. BattagliaA. BaùB. CappelliniF. CavaliereF. CuttaiaF. Del Torto  +34
This paper presents the design and expected performance of STRIP, a coherent polarimeter array for the LSPE balloon experiment. STRIP comprises 49 Q-band and 7 W-band cryogenic receivers cooled to 20 K, mounted in a $\sim 0.6$ m telescope’s focal plane for $\sim 1.5^\circ$ resolution. The Q-band channel is designed to measure and remove synchrotron polarization, while the W-band works with a bolometric channel to cross-check systematic effects, together enabling high-sensitivity CMB polarization measurements.
arXivarXiv · · August 1, 2012
0
The Large-Scale Polarization Explorer (LSPE)
LSPE collaborationS. AiolaG. AmicoP. BattagliaE. BattistelliA. BaùP. de BernardisM. BersanelliA. BoscaleriF. CavaliereA. CoppolecchiaA. Cruciani  +45
The Large-Scale Polarization Explorer (LSPE) is a balloon-borne mission designed to measure B-mode polarization of the cosmic microwave background, targeting a tensor-to-scalar ratio limit of $r = 0.03$ at 99.7% confidence. It observes 25% of the sky at approximately 1.5° resolution using two instruments: coherent polarimeters at 43 and 90 GHz, and bolometric polarimeters at 95, 145, and 245 GHz. The multi-frequency coverage enables foreground removal from Galactic synchrotron and dust emission.
arXivarXiv · · August 1, 2012
0
140
Intensity and polarization of the atmospheric emission at millimetric wavelengths at Dome Concordia
E. S. BattistelliG. AmicoA. BaùL. BergéÉ. BréelleR. CharlassierS. CollinA. CrucianiP. de BernardisC. DufourL. DumoulinM. Gervasi  +23
From 380 skydip scans at 150 GHz during the 2009/2010 summer campaign at Dome C, the BRAIN‑pathfinder experiment measured an extremely low atmospheric optical depth $\langle\tau_I\rangle = 0.050 \pm 0.003 \pm 0.011$, confirming the exceptional transparency of the Antarctic plateau for millimetre‑wave astronomy. Using the “am” radiative‑transfer model adapted to Dome C, the precipitable water vapour was inferred to be $\langle\mathrm{PWV}\rangle = 0.77^{+0.15}_{-0.12}\pm 0.06$ mm. Upper limits on air‑mass‑correlated polarized emission were placed for the first time: circular polarization $<0.2\%$ and linear polarization $<0.1\%$ (both at 95 % CL, including instrumental spurious polarization).
arXivarXiv · · March 26, 2012
0
26
QUBIC: The QU Bolometric Interferometer for Cosmology
QUBIC collaborationE. BattistelliA. BaùD. BennettL. BergéJ.-Ph. BernardP. de BernardisA. BounabÉ. BréelleE.F. BunnM. CalvoR. Charlassier  +48
The QUBIC instrument introduces bolometric interferometry for CMB B-mode detection, combining the sensitivity of bolometers with the systematic-error control of interferometry. An array of entry horns feeds an optical combiner; interference fringes are imaged onto bolometer-tiled focal planes. This design acts as a synthetic imager whose synthesized beam depends on horn positions, yielding low beam-related systematics. An autocalibration technique further controls other systematics, and sensitivity matches that of a conventional imager with the same number of horns. The instrument thus addresses the extreme sensitivity and systematics requirements for detecting inflationary B-modes.
arXivarXiv · · October 4, 2010
0
96
Frequent collaborators
M. Gervasi (21)
A. Passerini (21)
M. Zannoni (20)
A. Tartari (19)
F. Cavaliere (19)
S. Masi (18)
A. Mennella (18)
M. Bersanelli (18)
F. Piacentini (18)
L. Piccirillo (18)
G. Pisano (18)
P. de Bernardis (17)