MCP
AB

A. Behrens

20 papers in the library

Papers

20
Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic Recoil Data
XENON CollaborationE. Aprile…A. Behrens
Using XENON100 electronic recoil data, the search finds no evidence of dark matter interacting with electrons, excluding several leptophilic models. For axial-vector couplings, cross-sections above $6 \times 10^{-35} \,\text{cm}^2$ are ruled out for a particle mass of $m_\chi = 2 \,\text{GeV}/c^2$. Halo-independently, DAMA/LIBRA's signal is excluded as arising from axial-vector couplings (4.4$\sigma$), mirror dark matter (3.6$\sigma$), and luminous dark matter (4.6$\sigma$).
arXivarXiv · · July 28, 2015
0
101
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
E. AprileF. AgostiniM. AlfonsiL. AraziK. ArisakaF. ArneodoM. AugerC. BalanP. BarrowL. BaudisB. BauermeisterA. Behrens  +86
By combining material screening and production modifications, the XENON collaboration and Hamamatsu reduced the radioactivity of the R11410-21 photomultiplier tube (PMT) for the XENON1T dark matter experiment. Measurements of individual PMT components with ultra-low background germanium detectors guided the selection of cleaner materials and assembly changes. A screening of 216 tubes confirmed a mean activity of $^{238}$U at 1.9 mBq/PMT and $^{232}$Th at 0.9 mBq/PMT, which is sufficiently low for the experiment's background goals.
arXivarXiv · · March 26, 2015
0
148
Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
E. AprileF. AgostiniM. AlfonsiK. ArisakaF. ArneodoM. AugerC. BalanP. BarrowL. BaudisB. BauermeisterA. BehrensP. Beltrame  +79
The XENON1T dark matter detector requires a two-order-of-magnitude background reduction relative to XENON100. A water Cherenkov muon veto, 10 m in height and diameter, with 8-inch photomultipliers and reflective foil, was designed and optimized via Monte Carlo simulations. The central contribution is the demonstration that this veto achieves >99.5% efficiency for muons and >70% for muon-induced secondary showers, making muon-induced neutron backgrounds negligible for XENON1T.
arXivarXiv · · June 9, 2014
0
150
First Axion Results from the XENON100 Experiment
XENON100 CollaborationE. AprileF. AgostiniM. AlfonsiK. ArisakaF. ArneodoM. AugerC. BalanP. BarrowL. BaudisB. BauermeisterA. Behrens  +78
The XENON100 experiment reports the first direct search for axions and axion-like-particles using the axio-electric effect in liquid xenon. With 224.6 live days and a 34 kg fiducial exposure, no signal was found. The strongest limit to date is set on the axion-electron coupling $g_{Ae}$: below $7.7 \times 10^{-12}$ (90% CL) for solar axions, and below $1 \times 10^{-12}$ (90% CL) for axion-like-particles constituting the entirety of galactic dark matter in the 1--40 keV/$c^2$ mass range. Under the DFSZ and KSVZ models, QCD axions heavier than 0.3 eV/$c^2$ and 80 eV/$c^2$ are excluded, respectively.
arXivarXiv · · April 5, 2014
0
226
Observation and applications of single-electron charge signals in the XENON100 experiment
E. AprileM. AlfonsiK. ArisakaF. ArneodoC. BalanL. BaudisB. BauermeisterA. BehrensP. BeltrameK. BokelohA. BrownE. Brown  +68
The XENON100 experiment reports the observation of single-electron charge signals unrelated to WIMP interactions. These signals arise from photoionization of impurities in liquid xenon and metal components in the time projection chamber. They serve as a unique calibration source, enabling the inference of secondary-scintillation gain, extraction yield, and electron drift velocity, thus demonstrating the detector's excellent sensitivity to small charge signals.
arXivarXiv · · November 5, 2013
0
158
The neutron background of the XENON100 dark matter experiment
E.AprileM.AlfonsiK.ArisakaF.ArneodoC.BalanL.BaudisB.BauermeisterA.BehrensP.BeltrameK.BokelohA.BrownE.Brown  +65
The XENON100 experiment, located at LNGS, directly searches for WIMP dark matter via elastic scattering off xenon nuclei. This paper characterizes the nuclear recoil background from neutrons produced by (α,n) and spontaneous fission reactions from natural radioactivity in detector and shield materials, plus muon-induced neutrons. Using Monte Carlo simulations and measured radioactive contaminations, the study predicts the neutron background for the 2011 and 2012 WIMP search results: 0.11$^{+0.08}_{-0.04}$ and 0.17$^{+0.12}_{-0.07}$ events, concluding that this background does not limit the experiment's sensitivity.
arXivarXiv · · June 10, 2013
0
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
XENON100 CollaborationE. AprileM. AlfonsiK. ArisakaF. ArneodoC. BalanL. BaudisB. BauermeisterA. BehrensP. BeltrameK. BokelohA. Brown  +71
This paper reports the nuclear recoil calibration of the XENON100 dark matter detector using an external $^{241}\text{AmBe}$ neutron source. The data are compared with a detailed Monte Carlo simulation to extract the energy-dependent charge yield $Q_y$ and relative scintillation efficiency $L_{\text{eff}}$. Excellent spectral matching is achieved in the scintillation (S1) and ionization (S2) channels, as well as in the two-dimensional particle discrimination space. The results validate the signal acceptance used in the experiment's previous dark matter searches.
arXivarXiv · · April 4, 2013
0
110
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
XENON100 collaborationE. AprileM. AlfonsiK. ArisakaF. ArneodoC. BalanL. BaudisB. BauermeisterA. BehrensP. BeltrameK. BokelohA. Brown  +66
Using 224.6 live days × 34 kg of exposure from the XENON100 experiment, we report the most stringent upper limits on the spin-dependent WIMP-neutron cross section for WIMP masses above 6 GeV. No signal from axial-vector interactions with $^{129}$Xe and $^{131}$Xe nuclei was observed, yielding a minimum cross section of $3.5 \times 10^{-40} \text{ cm}^2$ at a WIMP mass of 45 GeV (90% confidence level).
arXivarXiv · · January 28, 2013
0
503
The distributed Slow Control System of the XENON100 Experiment
E. AprileM. AlfonsiK. ArisakaF. ArneodoC. BalanL. BaudisA. BehrensP. BeltrameK. BokelohE. BrownG. M. BrunoR. Budnik  +63
This paper describes the Slow Control System (SCS) of the XENON100 dark matter experiment, emphasizing its distributed, modular architecture. The system, implemented in Java following object-oriented principles, continuously monitors hundreds of parameters from dozens of instruments in real time and sets emergency alarms. The SCS has been operating remotely since mid 2008, maximizing flexibility and code reusability.
arXivarXiv · · November 5, 2012
0
11
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
XENON CollaborationE. AprileM. AlfonsiK. ArisakaF. ArneodoC. BalanL. BaudisB. BauermeisterA. BehrensP. BeltrameK. BokelohE. Brown  +65
This comment refutes Sorensen's claim that XENON100's spin-independent WIMP-nucleon cross-section upper limits below 10 GeV may be understated by an order of magnitude or more. The authors report that their own detailed analysis, performed before submitting their new result, does not confirm Sorensen's findings. They explain their rationale for excluding the described effect from their final analysis and list several potential problems with his study.
arXivarXiv · · August 28, 2012
0
0
Dark Matter Results from 225 Live Days of XENON100 Data
XENON100 CollaborationE. AprileM. AlfonsiK. ArisakaF. ArneodoC. BalanL. BaudisB. BauermeisterA. BehrensP. BeltrameK. BokelohE. Brown  +66
The XENON100 experiment, operating at LNGS, searched for dark matter with 224.6 live days × 34 kg exposure. With an ultra-low electromagnetic background of $(5.3 \pm 0.6) \times 10^{-3}$ events (kg day keVee)$^{-1}$, a blind analysis found two candidate events in the 6.6–30.5 keVnr range, consistent with the background expectation of $1.0 \pm 0.2$ events. A Profile Likelihood analysis over 6.6–43.3 keVnr set the most stringent limit on spin-independent WIMP-nucleon scattering cross sections for WIMP masses above 8 GeV/$c^2$, reaching a minimum of $2 \times 10^{-45}$ cm$^2$ at 55 GeV/$c^2$ (90% CL).
arXivarXiv · · July 25, 2012
0
2k+
Analysis of the XENON100 Dark Matter Search Data
XENON100 CollaborationE. AprileM. AlfonsiK. ArisakaF. ArneodoC. BalanL. BaudisA. BehrensP. BeltrameK. BokelohE. BrownG. Bruno  +62
The paper presents the general analysis methods developed for the XENON100 dark matter search, which uses a dual-phase xenon time projection chamber to detect WIMP-nucleon interactions. These methods, applied to the 100.9 and 224.6 live-day science runs, underlie the reported results on spin-independent elastic, spin-dependent elastic, and inelastic WIMP-nucleon cross-sections, providing the technical framework for the experiment's dark matter constraints.
arXivarXiv · · July 14, 2012
0
117
The XENON100 Dark Matter Experiment
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensE. BrownJ. M. R. CardosoB. ChoiD. ClineS. Fattori  +24
The XENON100 experiment targets WIMP dark matter via nuclear recoils in a 62 kg liquid xenon (LXe) time projection chamber (TPC), surrounded by a 99 kg LXe veto. Both volumes are instrumented with photomultiplier tubes and housed in a low-radioactivity stainless steel vessel shielded by passive materials. Installed underground at LNGS (Italy), its design goal is a spin-independent WIMP-nucleon cross-section sensitivity of $\sigma = 2 \times 10^{-45} \text{ cm}^2$ for a 100 GeV/$c^2$ WIMP.
arXivarXiv · · July 11, 2011
0
567
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensK. BokelohE. BrownT. BruchG. BrunoJ. M. R. Cardoso  +43
Using 100.9 live-days of XENON100 data, this paper reports limits on the WIMP-nucleon cross section for inelastic dark matter. With three observed events in the signal region (expected background $1.8 \pm 0.6$), the results rule out, at 90% confidence level, the inelastic dark matter scattering off iodine as an explanation for the DAMA/LIBRA modulation.
arXivarXiv · · April 15, 2011
0
102
Dark Matter Results from 100 Live Days of XENON100 Data
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensK. BokelohE. BrownT. BruchG. BrunoJ. M. R. Cardoso  +43
The XENON100 experiment, a two-phase time projection chamber with a 62 kg liquid xenon target installed underground, found no evidence for dark matter in 100.9 live days of data. Three candidate events were observed in a pre-defined signal region against an expected background of $1.8 \pm 0.6$ events. This null result sets the most stringent limit on dark matter interactions at the time, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above $7.0 \times 10^{-45}$ cm$^2$ for a WIMP mass of 50 GeV/$c^2$ at 90% confidence level.
arXivarXiv · · April 13, 2011
0
1k+
Material screening and selection for XENON100
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensK. BokelohE. BrownJ.M.R. CardosoB. ChoiD. Cline  +29
This paper reports the extensive material screening campaign for the XENON100 dark matter experiment, operated underground at LNGS, Italy. Using ultra-sensitive HPGe gamma spectrometry and mass spectrometry for low-mass plastics, the authors measured radioactive contaminations of all candidate materials. Detailed tables of contamination levels are presented, with implications for the experiment's background and construction decisions.
arXivarXiv · · March 30, 2011
0
172
Likelihood Approach to the First Dark Matter Results from XENON100
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensK. BokelohE. BrownT. BruchJ. M. R. CardosoB. Choi  +34
This paper presents a statistical model for direct Dark Matter detection experiments using the Profile Likelihood ratio as a frequentist test statistic. The model incorporates calibration data as control measurements and includes systematic uncertainties from detectors and astrophysics. Applied to XENON100's first data release, it extracts additional information and sets a single limit on the spin-independent elastic WIMP-nucleon scattering cross-section, with a minimum of $2.4 \times 10^{-44} \, \mathrm{cm}^2$ for a WIMP mass of $50 \, \mathrm{GeV}/c^2$, including all relevant uncertainties.
arXivarXiv · · March 1, 2011
0
213
Study of the electromagnetic background in the XENON100 experiment
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensK. BokelohE. BrownJ.M.R. CardosoB. ChoiD. Cline  +33
The XENON100 experiment, located at LNGS, aims to directly detect dark matter WIMPs. This paper presents a comprehensive study of the predicted electronic recoil background from radioactive decays. Using GEANT4 Monte Carlo simulations with detailed detector geometry and measured radioactivity of all components, the background in the WIMP-search energy range (0-100 keV) within the 30 kg fiducial mass is predicted to be less than $10^{-2}$ events/(kg-day-keV). This prediction, consistent with the design goal, agrees very well with commissioning data from Fall 2009.
arXivarXiv · · January 20, 2011
0
150
First Dark Matter Results from the XENON100 Experiment
XENON100 CollaborationE. AprileK. ArisakaF. ArneodoA. AskinL. BaudisA. BehrensE. BrownJ. M. R. CardosoB. ChoiD. B. ClineS. Fattori  +27
The XENON100 experiment, using 62 kg of liquid xenon in a dual-phase time projection chamber, reports its first dark matter search results from 11.17 live days of data. With a 40 kg fiducial target and no events observed in the predefined signal region, it excludes spin-independent WIMP-nucleon elastic scattering cross-sections above $3.4 \times 10^{-44}$ cm$^2$ for 55 GeV/c$^2$ WIMPs at 90% confidence level. For WIMP masses below 20 GeV/c$^2$, this constraint challenges the interpretation of CoGeNT and DAMA signals as spin-independent, elastic light WIMP interactions.
arXivarXiv · · May 3, 2010
0
571
Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr
A. ManalaysayT. Marrodan UndagoitiaA. AskinL. BaudisA. BehrensA. D. FerellaA. KishO. LebedaR. SantorelliD. VenosA. Vollhardt
The authors introduce a calibration method for liquid xenon (LXe) detectors using the short-lived noble gas $^{83\text{m}}$Kr, which disperses uniformly throughout the detector. Its two transitions at 9.4 and 32.1 keV enable background-free decay identification. Applying this method, they find that LXe light yield increases at lower energies while electric field quenching decreases. Any introduced long-lived backgrounds would be below $67\times10^{-6}$ events/kg/day for next-generation dark matter searches.
arXivarXiv · · August 5, 2009
0
Frequent collaborators
L. Baudis (19)
A. Kish (19)
E. Aprile (18)
K. Arisaka (18)
F. Arneodo (18)
E. Brown (18)
S. Fattori (18)
U. Oberlack (18)
E. Pantic (18)
G. Plante (18)
M. Schumann (18)
P. Shagin (18)