Design and operation of APEX-LD: a compact levitated dipole for the confinement of electron-positron pair plasmas
A. CardM. R. StonekingA. DellerE. V. Stenson
A. Card
M. R. Stoneking
A. Deller
E. V. Stenson
+4
APEX-LD is a compact levitated dipole trap for confining electron–positron pair plasmas, whose central element is a 7.5-cm-radius closed-loop high-temperature superconducting (ReBCO) floating coil. The coil is solder-potted in a gold-plated-copper case, charged inductively within a resealable in-vacuum cryostat, and reliably produces persistent currents of ~60 kA-turns with an axial field $B_0 \sim 0.5$ T. The authors report levitation times over three hours with vertical stability $\sigma_z < 20$ $\mu$m, and demonstrate robustness under routine quenches and mechanical shocks. Preliminary electron experiments and next steps toward positron injection are described.