MCP
AG

A. Giuliani

200+ papers in the library

Papers

30
The CROSS experiment: detector construction, background projection, and sensitivity to 100^{100}Mo 0ν2I^20\nu2β decay
D. AugusteA. S. Barabash…A. Giuliani
The CROSS experiment searches for neutrinoless double-beta decay in $^{100}$Mo using an array of scintillating cryogenic calorimeters containing 4.9 kg of $^{100}$Mo at the Canfranc underground laboratory. Geant4-based simulations predict a background index of 3.2(5) $\times$ 10$^{-3}$ cnts/keV/kg/yr in a 100-keV window around the $Q$-value (3034 keV). With this background and a 1-year run, the experiment could achieve a world-leading sensitivity of $T_{1/2} \sim 4 \times 10^{24}$ yr. Even with a factor 3 or 10 worse background, competitive sensitivity remains possible over 2 years.
arXivarXiv · · July 29, 2026
0
0
Search for Sterile Neutrinos with CUPID-0
O. AzzoliniJ. W. Beeman…A. Giuliani
The CUPID-0 experiment searched for sterile neutrinos by looking for spectral distortions in the double beta decay of $^{82}$Se, which would be compatible with the emission of such a particle. Using a Zn$^{82}$Se exposure of 9.95 kg$\cdot$yr and a detailed background model down to 200 keV, the analysis tested sterile neutrino masses between 0.5 and 1.5 MeV. No signal was found, leading to 90% confidence-level upper limits on the mixing probability $\sin^2\theta$. The most stringent bound, $\sin^2\theta < 8 \times 10^{-3}$, was set for a sterile neutrino mass of 0.7 MeV.
arXivarXiv · · March 18, 2026
0
0
Muon veto system for the CROSS double-beta decay search experiment
A. S. BarabashL. Bergé…A. Giuliani
For the CROSS experiment searching for neutrinoless double-beta decay of $^{100}$Mo, a dedicated muon veto system is developed to suppress the dominant background from residual cosmic muons ($\sim$20 $\mu$/m$^2$/h) at the Canfranc underground laboratory. The veto consists of four lateral, one top, and four bottom sectors surrounding the low-background setup. Using two trigger logics based on coincidences with either two sectors or a single sector, Monte Carlo simulations show that 99.2% and 99.7% of muon-induced events in the region of interest ($\sim$3 MeV) can be rejected. With the adopted coincidence strategy, the muon-induced background is reduced to $\sim$2 $\times$ $10^{-3}$ cnts/keV/kg/yr, compatible with the high-sensitivity search.
arXivarXiv · · October 31, 2025
0
0
End-to-End Data Analysis Methods for the CUORE Experiment
D. Q. AdamsC. Alduino…A. Giuliani
The CUORE experiment, a ton-scale array of cryogenic calorimeters operating at ~10 mK, achieved the most stringent limit on the neutrinoless double-beta ($0\nu\beta\beta$) decay half-life of $^{130}$Te. This work describes the end-to-end analysis tools and methods developed for CUORE, treating each calorimeter independently for optimization, data acquisition, and analysis. The core contribution is the detailed evaluation of the energy-dependent detector response and signal efficiency used in the latest $0\nu\beta\beta$ decay search, enabling high-quality datasets for multiple rare-event searches.
arXivarXiv · · October 29, 2025
0
3
Reconstruction of cosmic-ray muon events with CUORE
CUORE CollaborationD. Q. Adams…A. Giuliani
By using the segmentation of the CUORE cryogenic detector array, a multi-objective optimization algorithm achieves in-situ 3D reconstruction of through-going cosmic-ray muons without time-of-flight estimation. The integral muon flux measured underground at the Laboratori Nazionali del Gran Sasso agrees with other experiments. This work is the first demonstration of 3D particle tracking with per-event angular determination in a millikelvin detector, critical for validating muon-related background in next-generation neutrinoless double-beta decay experiments.
arXivarXiv · · September 5, 2025
0
0
Cryogenic light detectors with thermal signal amplification for 0I^½I^2I^20νββ search experiments
A. ArmatolA. S. Barabash…A. Giuliani
We tested 10 germanium cryogenic light detectors with Neganov-Trofimov–Luke (NTL) thermal signal amplification, assembled with 45 mm cubic scintillating crystals, for use in neutrinoless double-beta decay searches (CROSS, BINGO, CUPID). Operating at milli-Kelvin temperatures, 8 detectors showed no leakage current up to 100 V bias. At 80 V, the signal-to-noise ratio gain was about 9, achieving baseline noise RMS of $O(10\,\mathrm{eV})$ and a rise time of about 0.5 ms. Simulations indicated that this NTL technology offers a viable background-reduction solution for CUPID.
arXivarXiv · · July 21, 2025
0
7
Exploring the keV-scale physics potential of CUORE
CUORE CollaborationD. Q. Adams…A. Giuliani
This paper reports the keV-scale analysis of the CUORE experiment using over 2 tonne yr of data. By applying stricter selection to optimize thresholds at 10 keV and 3 keV, the analysis achieves average baseline resolutions of 2.54 ± 0.14 keV and 1.18 ± 0.02 keV FWHM, respectively. The overall background is reduced by about an order of magnitude, reaching 2.06 ± 0.05 counts/(keV kg days) at 10 keV and 16 ± 2 counts/(keV kg days) at 3 keV. Near-threshold reconstruction efficiencies are evaluated for the first time, yielding 50 ± 2 % at 10 keV and 26 ± 4 % at 3 keV, demonstrating the scalability of tonne-scale cryogenic calorimeters for low-energy physics.
arXivarXiv · · May 29, 2025
0
5
The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment
D. Q. AdamsC. Alduino…A. Giuliani
Using data from the CUORE experiment and the Copernicus Earth Observation program, this study reports the first detection of marine microseismic vibrations with mK-scale calorimeters. The analysis reveals seasonal Mediterranean Sea activity that impacts CUORE's energy thresholds, resolution, and sensitivity over four years, underscoring the need to address faint environmental noise in ultra-sensitive experiments. The paper also demonstrates a noise decorrelation algorithm using auxiliary sensors that reduces vibrational noise and improves detector performance.
arXivarXiv · · May 13, 2025
0
3
Sensitivity of the CUPID experiment to 0I^½I^2I^20νββ decay of 100^{100}Mo
K. AlfonsoA. Armatol…A. Giuliani
CUPID, a next-generation bolometric experiment using 1596 Li$_2$MoO$_4$ crystals at ~10 mK in the CUORE cryostat, searches for neutrinoless double-beta decay of $^{100}$Mo. With a background of $1.0 \times 10^{-4}$ counts/keV/kg/yr and 5 keV FWHM energy resolution at the Q-value, its Bayesian 90% credible interval exclusion sensitivity gives a half-life $′T_{1/2} > 1.6 \times 10^{27}$ yr, corresponding to an effective Majorana neutrino mass $′m_{\beta\beta} < 9.6$--$28$ meV; the Frequentist 3σ discovery sensitivity is $′T_{1/2}= 1.0 \times 10^{27}$ yr, corresponding to $′m_{\beta\beta}= 12$--$36$ meV.
arXivarXiv · · April 19, 2025
0
Half-life and precision shape measurement of 2νββ decay of 130^{130}Te
D. Q. AdamsC. Alduino…A. Giuliani
Using 1038 kg yr of CUORE data, the $2\nu\beta\beta$ half-life of $^{130}$Te is measured as $(9.32^{+0.05}_{-0.04}(\text{stat.})^{+0.07}_{-0.07}(\text{syst.}))\times10^{20}$ yr, doubling previous precision. The improved signal-to-background ratio enables the first application of the enhanced $2\nu\beta\beta$ formalism to $^{130}$Te, yielding an effective axial coupling credibility interval and higher-order nuclear matrix element ratios. The second-to-first ratio agrees with models, while the third-to-first deviates, providing nuclear model tests relevant to $0\nu\beta\beta$ searches.
arXivarXiv · · March 31, 2025
0
Precise 113^{113}Cd ββ decay spectral shape measurement and interpretation in terms of possible gAg_A quenching
I. BandacL. BergeJ.M. Calvo-MozotaP. CarnitiM. ChapellierF. A. DanevichT. DixonL. DumoulinF. FerriA. GiulianiC. GottiPh. Gras  +20
This paper presents a high-precision measurement of the $\beta$ decay spectrum of $^{113}$Cd, a fourth-forbidden non-unique decay, using a 0.43 kg CdWO$_4$ crystal bolometer operated at low temperature in the Canfranc underground laboratory. By fitting the measured spectrum to three nuclear models (IBFM-2, MQPM, NSM) via a Bayesian approach with two free parameters, the effective weak axial-vector coupling constant $g_A^{\text{eff}}$ is constrained to between 1.0 and 1.2, compatible with possible quenching. The half-life is measured as $7.73^{+0.60}_{-0.57} \times 10^{15}$ yr, agreeing with previous experiments.
arXivarXiv · · November 5, 2024
0
Search for fractionally charged particles with CUORE
CUORE CollaborationD. Q. Adams…A. Giuliani
The Cryogenic Underground Observatory for Rare Events (CUORE), a 988-crystal TeO$_2$ array operating below 20 mK, is used to search for fractionally charged particles (FCPs) with charges between $e/24$ and $e/5$. Using the first tonne-year of exposure, no significant excess of FCP candidate tracks is found, leading to the most stringent limits on the underground FCP flux in this charge range at 90% confidence level. This work demonstrates the sensitivity of tonne-scale sub-Kelvin detectors to exotic particle signatures.
arXivarXiv · · June 18, 2024
0
15
Simplified and Flexible Coils for Stellarators using Single-Stage Optimization
R. JorgeA. GiulianiJ. Loizu
This work shows that single-stage optimization, which directly combines plasma-coil design, can yield stellarator configurations with dramatically simplified coils. The method produces designs with as few as one to three coils per half field period, including quasisymmetric stellarators, and can generate both quasi-axisymmetric and quasi-helical equilibria from a single coil set. This streamlines device design by simultaneously addressing confinement, stability, and engineering constraints.
arXivarXiv · · June 12, 2024
0
19
Development of large-volume 130^{130}TeO2_2 bolometers for the CROSS 2I^22β decay search experiment
F. T. AvignoneA. S. Barabash…A. Giuliani
This paper reports the development of large-volume $^{130}$TeO$_2$ bolometers for the CROSS double-beta decay experiment. Powder purification via directional solidification reduced total impurities to a few ppm. Four large cubic crystals (45 mm) were characterized underground, showing high bolometric performance and very low internal radioactivity: $^{210}$Po activity ~1 mBq/kg, and $^{228}$Th/$^{226}$Ra below 0.01 mBq/kg. Two crystals were coated with thin metal films (Al layer or AlPd grid) to enable surface-event tagging via pulse-shape discrimination, meeting the experiment's requirements.
arXivarXiv · · June 3, 2024
0
6
A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment
D. AugusteA. S. Barabash…A. Giuliani
The paper presents a mechanical-structure design for the CROSS neutrinoless double-beta decay experiment, which holds scintillating bolometers in a modular Cu frame. Two versions are introduced: Thick (~15% Cu/crystal mass) and Slim (~6% Cu). The Slim design reduces background but yields higher baseline noise for light detectors (0.10–0.35 keV RMS vs 0.05–0.09 keV). Despite this, both achieve 5–7 keV FWHM energy resolution at 2615 keV, near the 3034 keV Q-value of ¹⁰⁰Mo, and acceptable α/γ(β) discrimination. The structure will be used with upgraded light detectors employing the Neganov-Trofimov-Luke effect.
arXivarXiv · · May 29, 2024
0
14
Data-driven background model for the CUORE experiment
CUORE CollaborationD. Q. Adams…A. Giuliani
We present a data-driven background model for the CUORE experiment, built from a Bayesian fit to energy spectra across a broad range using 1038.4 kg yr of exposure. The model exploits detector granularity, exposure, and operational stability to resolve spatial and time-dependent backgrounds, achieving sensitivity to bulk activities as low as 10 nBq kg$^{-1}$ and surface activities as low as 0.1 nBq cm$^{-2}$. The extracted contamination levels are compared with prior radio-assay data, informing future background mitigation strategies for CUORE and the CUPID experiment.
arXivarXiv · · May 28, 2024
0
36
Searching for Beyond the Standard Model physics using the improved description of 100^{100}Mo 2νββ2νββ decay spectral shape with CUPID-Mo
C. AugierA. S. Barabash…A. Giuliani
Using 1.47 kg×y of $^{100}$Mo exposure from the CUPID-Mo experiment, the authors search for Beyond Standard Model (BSM) physics via distortions in the $2\nu\beta\beta$ decay spectral shape. They set limits on $0\nu\beta\beta$ decays with Majoron emission, Lorentz-violating $2\nu\beta\beta$ decay, and $2\nu\beta\beta$ decay producing a sterile neutrino. A key novelty is the investigation of systematic uncertainty from modeling the $2\nu\beta\beta$ spectral shape with an improved model, an effect not previously considered. This motivates BSM searches in the upcoming CUPID experiment.
arXivarXiv · · May 17, 2024
0
Constraints on Lepton Number Violation with the 2 tonne⋅\cdotyr CUORE Dataset
CUORE CollaborationD. Q. Adams…A. Giuliani
The CUORE experiment searches for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te using a tonne-scale cryogenic calorimeter at milli-kelvin temperatures. With over 2 tonne$\cdot$year TeO$_2$ exposure, no evidence of $0\nu\beta\beta$ is found, yielding a lower limit on the half-life of $T_{1/2} > 3.5 \times 10^{25}$ years (90% C.I.). This result and the stable operation of nearly 1000 detectors demonstrate infrastructure for future searches.
arXivarXiv · · April 5, 2024
0
11
AGILE gamma-ray detection of the exceptional GRB 221009A
M. TavaniG. PianoA. BulgarelliL. FoffanoA. UrsiF. VerrecchiaC. PittoriC. CasentiniA. GiulianiF. LongoG. PanebiancoA. Di Piano  +38
The AGILE satellite detected the long-duration gamma-ray burst GRB 221009A in the MeV–GeV range. Hard X-ray/MeV prompt emission lasted hundreds of seconds, with peak brightness between 200–300 seconds after trigger. Intense GeV emission persisted into the early afterglow up to 10,000 seconds. The key feature is the coexistence of time-variable MeV-peaked emission with hardening power-law GeV radiation during the prompt phase, suggesting distinct physical mechanisms at different locations.
arXivarXiv · · September 19, 2023
0
39
Test of 116^{116}CdWO4_4 and Li2_2MoO4_4 scintillating bolometers in the CROSS underground facility with upgraded detector suspension
A. AhmineI. C. Bandac…A. Giuliani
In preparation for the CROSS double-beta decay experiment, a new detector suspension with magnetic dumping was installed in a pulse-tube cryostat and tested with two scintillating bolometers: $^{116}$CdWO$_4$ (CWO-enr) and Li$_2$MoO$_4$ (LMO). Both detectors reached 6 keV FWHM energy resolution for 2.6 MeV gamma quanta, among the best for such compounds. The CWO-enr baseline noise resolution improved by 2 keV compared to its previous best measurement. A Ge light detector with Neganov-Trofimov-Luke amplification achieved 20 eV FWHM noise resolution at 60 V bias. The LMO crystal showed high radiopurity with only traces of $^{210}$Po and $^{226}$Ra (0.1 mBq/kg each).
arXivarXiv · · July 27, 2023
0
17
Measurement of the 2νββ2νββ decay rate and spectral shape of 100^{100}Mo from the CUPID-Mo experiment
C. AugierA. S. Barabash…A. Giuliani
The CUPID-Mo experiment reports the most precise measurement of the $2\nu\beta\beta$ decay half-life of $^{100}$Mo to the ground state of $^{100}$Ru: $(7.07 \pm 0.02 \text{(stat.)} \pm 0.11 \text{(syst.)}) \times 10^{18}$ yr, with a relative precision of $\pm1.6\%$. The study also constrains higher-order corrections to the spectral shape, reporting a novel measurement of the shape factor $\xi_{3,1}=0.45 \pm 0.03 \text{(stat.)} \pm 0.05 \text{(syst.)}$, and extracts the first value for the effective axial vector coupling constant from a $2\nu\beta\beta$ spectral shape analysis.
arXivarXiv · · July 26, 2023
0
0
Measurement of the 2νββνββ Decay Half-Life of Se-82 with the Global CUPID-0 Background Model
O. AzzoliniJ. W. Beeman…A. Giuliani
Using the CUPID-0 global background model that combines two measurement campaigns (8.82 kg·yr exposure of \(^{82}\)Se), the background sources around 3 MeV are identified with improved precision, supporting the neutrinoless double-beta decay search for next-generation CUPID. The two-neutrino double-beta decay half-life of \(^{82}\)Se is measured with unprecedented accuracy: \(T_{1/2}^{2\nu} = [8.69 \pm 0.05 \text{(stat.)}~^{+0.09}_{-0.06} \text{(syst.)}] \times 10^{19}~\text{yr}\).
arXivarXiv · · June 26, 2023
0
First demonstration of 30 eVee ionization energy resolution with Ricochet germanium cryogenic bolometers
C. AugierG. Baulieu…A. Giuliani
The Ricochet experiment will search for new physics by measuring coherent elastic neutrino-nucleus scattering from reactor antineutrinos with sub-100 eV nuclear recoil sensitivity. This paper reports the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) using the CryoCube germanium cryogenic bolometer, coupled with a dedicated HEMT-based front-end. This resolution is an order of magnitude better than previous best results from EDELWEISS and SuperCDMS, and a factor of three better than the prior HEMT-based CDMS-II detector. The findings are discussed in the context of Ricochet's background mitigation goals.
arXivarXiv · · May 31, 2023
0
29
Study of collision and γγ-cascade times following neutron-capture processes in cryogenic detectors
CRAB collaborationG. Soum-Sidikov…A. Giuliani
Accurate nuclear recoil spectra from neutron capture in cryogenic detectors require modelling the interplay between the de-excitation $\gamma$-cascade timing and atomic collisions. The authors couple FIFRELIN and IRADINA codes to simulate this for Al$_2$O$_3$, Si, Ge, and CaWO$_4$ crystals exposed to thermal neutrons. Timing effects produce new calibration peaks and alter the continuous recoil distribution, impacting sub-keV calibration for Dark Matter and CE$\nu$NS experiments.
arXivarXiv · · May 17, 2023
0
12
The background model of the CUPID-Mo 0νββ0νββ experiment
CUPID-Mo CollaborationC. Augier…A. Giuliani
CUPID-Mo, a demonstrator for the next-generation $0\nu\beta\beta$ decay experiment CUPID, operated 20 enriched Li$_2^{100}$MoO$_4$ scintillating bolometers with particle identification at the Laboratoire Souterrain de Modane. This paper presents a detailed background model that accurately reproduces the experimental data, enabling precise studies of $2\nu\beta\beta$ decay and other processes. The model yields a background index of $3.7^{+0.9}_{-0.8}(\text{stat})^{+1.5}_{-0.7}(\text{syst})\times10^{-3}$ counts/$\Delta E_{\text{FWHM}}$/mol$_{\text{iso}}$/yr in the region of interest, the lowest achieved in a bolometric $0\nu\beta\beta$ experiment.
arXivarXiv · · May 2, 2023
0
Li2_2100depl^{100\textrm{depl}}MoO4_4 Scintillating Bolometers for Rare-Event Search Experiments
I. C. BandacA. S. BarabashL. BergéYu. A. BorovlevJ. M. Calvo-MozotaP. CarnitiM. ChapellierI. DafineiF. A. DanevichL. DumoulinF. FerriA. Giuliani  +26
We report that Li$_2$$^{100\textrm{depl}}$MoO$_4$ scintillating bolometers, using molybdenum depleted in the double-$\beta$ active isotope $^{100}$Mo, achieve spectrometric performance (3--6 keV FWHM at 0.24--2.6 MeV), moderate scintillation (0.3--0.6 keV/MeV), and radiopurity ($^{228}$Th and $^{226}$Ra below a few $\mu$Bq/kg) comparable to the best Li$_2$MoO$_4$ detectors with natural or enriched molybdenum, making them suitable for rare-event searches.
arXivarXiv · · April 25, 2023
0
ZnO-based scintillating bolometers: New prospects to study double beta decay of 64^{64}Zn
A. ArmatolB. BroermanL. DumoulinA. GiulianiH. KhalifeM. LaubensteinP. LoaizaP. de MarcillacS. MarnierosS.S. NagornyS. NisiC. Nones  +6
This paper reports the first detailed study of a ZnO-based cryogenic scintillating bolometer for searching for rare processes in zinc isotopes. A 7.2 g ZnO detector, with over 80% zinc mass, demonstrates good performance: baseline energy resolution of 1.0--2.7 keV FWHM, a low-energy threshold of 2.0--6.0 keV, and effective identification of $\beta/\gamma$ events from $\alpha$ events using only heat signal time properties. From 271 h of above-ground background data, limits on double beta decay of $^{64}$Zn and $^{70}$Zn are set at $\mathcal{O}(10^{17}$--$10^{18})$ yr, with a 10 kg-scale experiment potentially reaching $\mathcal{O}(10^{24})$ yr sensitivity.
arXivarXiv · · April 11, 2023
0
6
Twelve-crystal prototype of Li2_2MoO4_4 scintillating bolometers for CUPID and CROSS experiments
CUPIDCROSS collaborations…A. Giuliani
This paper reports the construction and long-term operation of a twelve-crystal array of Li$_2$MoO$_4$ scintillating bolometers, each 0.28 kg, equipped with 16 Ge light detectors, to optimize detector design for the CROSS and CUPID double-beta decay experiments. The study systematically varied phonon sensor size, Ge detector shape and supplier, and light collection conditions (reflector and surface coating). The array ran for eight months in a low-background cryostat at Canfranc, achieving sensitivity to radioactive contamination at the $\mu$Bq/kg level for $^{228}$Th and $^{226}$Ra.
arXivarXiv · · April 10, 2023
0
20
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
CUPID collaborationK. Alfonso…A. Giuliani
This paper reports the first test of CUPID-design bolometric light detectors with NTD-Ge sensors inside a pulse-tube cryostat, a setting that introduces strong mechanical vibrations. Each of the four tested detectors achieved a baseline noise well below the CUPID goal of 100 eV RMS, with measured values of 70–90 eV RMS. One detector reached an energy resolution of 0.71(5) keV FWHM at the 356 keV line of a $^{133}$Ba source, the best reported for any gamma detector in that energy range. The results validate the detector design for the CUPID neutrinoless double-beta decay experiment.
arXivarXiv · · April 10, 2023
0
14
Sensitivity of the Cherenkov Telescope Array to spectral signatures of hadronic PeVatrons with application to Galactic Supernova Remnants
Cherenkov Telescope Array ConsortiumF. Acero…A. Giuliani
This work assesses the potential of the Cherenkov Telescope Array (CTA) to identify hadronic PeVatrons—sources accelerating cosmic rays to ~PeV energies—using very-high-energy gamma-ray spectral signatures. Applying a simplified model of Galactic supernova remnant (SNR) evolution, the authors estimate that scanning the Galactic plane with CTA for 10 hours will detect a gamma-ray signal from about 9 SNRs, and that deep observations (~100 hours per source) can confirm them as PeVatrons via spectral features.
arXivarXiv · · March 27, 2023
2
30
Frequent collaborators
C. Nones (121)
G. Pessina (97)
L. Pattavina (85)
I. Dafinei (84)
S. Pirro (81)
C. Tomei (81)
F. Bellini (79)
L. Cardani (79)
L. Gironi (78)
E. Previtali (78)
N. Casali (77)
M. Pavan (77)