MCP
AK

A. Kopec

46 papers in the library

Papers

30
The liquid-phase xenon purification system of the XENONnT dark matter experiment
E. AprileJ. Aalbers…A. Kopec
The XENONnT dark matter experiment developed a liquid-phase xenon purification system to remove impurities, particularly O$_2$, from 8.5 t of liquid xenon, achieving an O$_2$-equivalent concentration below 100 ppt needed for sensitivity. The system circulates liquid xenon (~2 L/min at ~175 K) through two purifier types: a Q5 copper-on-alumina purifier with nearly 100% efficiency for initial cleanup, followed by a St707 getter purifier with 55% efficiency for sustained operation with negligible background. Commissioning achieved below 19 ppt, with over 86% electron survival across the 1.5-meter TPC.
arXivarXiv · · October 23, 2026
0
0
Search for Magnetic and Spin-Independent Inelastic Dark Matter with XENONnT
E. AprileJ. Aalbers…A. Kopec
XENONnT sets 90% C.L. upper limits on magnetic and spin-independent inelastic dark matter using 2.1 tonne-years of data. The search exploits the delayed de-excitation photon after an initial nuclear recoil, applying directional and kinematic selections on the inferred speed and direction of the excited particle between scatter and decay sites. No signal is found, yielding constraints across the GeV/c$^2$–TeV/c$^2$ mass range.
arXivarXiv · · August 15, 2026
0
1
Direct Measurement of the 212Pb^{212}\mathrm{Pb} and 214Pb^{214}\mathrm{Pb} β\beta Decay Branching Ratios with the XENONnT Experiment
E. AprileJ. Aalbers…A. Kopec
Using calibration data from the XENONnT dual-phase liquid xenon time projection chamber, this work reports the most precise direct measurements of the $^{212}\mathrm{Pb}$ and $^{214}\mathrm{Pb}$ $\beta$-decay branching ratios to the ground state. The measured values are $(14.75 \pm 0.20(\mathrm{stat}) ^{+0.14}_{-0.40}(\mathrm{sys}))\%$ for $^{212}\mathrm{Pb}$ and $(9.8 \pm 0.3(\mathrm{stat}) ^{+0.8}_{-0.2}(\mathrm{sys}))\%$ for $^{214}\mathrm{Pb}$. These results improve background modeling for rare-event searches, thereby enhancing sensitivity to dark matter and solar neutrinos.
arXivarXiv · · June 16, 2026
0
0
Enhancing Neutrinoless Double-Beta Decay Sensitivity of Liquid-Xenon Time Projection Chamber with Augmented Convolutional Neural Network
E. AprileJ. Aalbers…A. Kopec
Gamma-ray backgrounds from detector materials limit neutrinoless double-beta decay ($0\nu\beta\beta$) searches in liquid-xenon time projection chambers. The authors built an augmented convolutional neural network (A-CNN) that extracts additional event-topology information from the detector data. Using XENONnT simulation and calibration data, the model rejects over 60% of the background while retaining 90% signal acceptance, improving the projected $^{136}$Xe $0\nu\beta\beta$ sensitivity by about 40%.
arXivarXiv · · March 20, 2026
0
0
Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT
E. AprileJ. Aalbers…A. Kopec
This paper reports a search for dark matter using ionization-only signals from 7.83 tonne$\times$year of XENONnT exposure. No significant excess was found, and the strongest constraints were set on spin-independent DM–nucleon scattering, excluding cross sections above $6.0\times10^{-45}$ cm$^2$ at a DM mass of 5 GeV/$c^2$, pushing sensitivity toward the neutrino fog.
arXivarXiv · · January 16, 2026
0
28
Constraints on Solar Reflected Dark Matter from a combined analysis of XENON1T and XENONnT data
XENON CollaborationE. Aprile…A. Kopec
This work searches for sub-GeV dark matter upscattered by solar reflection in the heavy mediator scenario. By analyzing XENON1T ionization-only and XENONnT low-energy electronic recoil data, they enhance sensitivity to low-mass dark matter via electron scattering and reduced detection thresholds. The analysis excludes previously unconstrained dark matter-electron scattering cross sections for masses between $4.6\,\text{keV}/c^2$ and $20\,\text{keV}/c^2$, and between $0.2\,\text{MeV}/c^2$ and $2\,\text{MeV}/c^2$, reaching a minimum of $3.41\times10^{-39}\,\text{cm}^2$ at $0.3\,\text{MeV}/c^2$ (90% confidence level).
arXivarXiv · · December 22, 2025
0
0
Spectral Measurement of the 214^{214}Bi beta-decay to the 214^{214}Po Ground State with XENONnT
E. AprileJ. Aalbers…A. Kopec
Using the XENONnT detector, we measure the $^{214}$Bi beta-decay spectrum to the $^{214}$Po ground state, a first-forbidden non-unique transition. A dedicated algorithm selects a high-purity sample of ground-state decays, excluding events with gamma rays. Comparing the measured spectrum (up to 3.27 MeV) with nuclear models, the conserved vector current (CVC) hypothesis best describes the data. This dataset also yields charge and light yield curves for electronic recoils, extending detector response modeling to the MeV scale.
arXivarXiv · · October 6, 2025
0
2
Challenging Spontaneous Quantum Collapse with XENONnT
E. AprileJ. Aalbers…A. Kopec
Using 1-140 keV electronic recoil data from the XENONnT dark matter detector's first science run, we set new world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose collapse models. The analysis incorporates a model that accounts for cancellation effects in the emitted X-ray spectrum due to opposing electron-proton charges in xenon atoms. The limits improve previous best constraints by two orders of magnitude and a factor of five, respectively, and exclude the original continuous spontaneous localization model parameters for the first time.
arXivarXiv · · June 5, 2025
0
0
WIMP Dark Matter Search using a 3.1 Tonne-Year Exposure of the XENONnT Experiment
E. AprileJ. Aalbers…A. Kopec
The XENONnT experiment reports a WIMP dark matter search using 3.1 tonne-years of exposure from two science campaigns. A blind analysis of nuclear recoil events above 3.8 keV$_{NR}$ found no significant excess. The resulting upper limit on the spin-independent WIMP-nucleon cross section reaches a minimum of $1.7 \times 10^{-47}\,\mathrm{cm}^2$ at 90% CL for a 30 GeV/$c^2$ WIMP, with a best median sensitivity of $1.4 \times 10^{-47}\,\mathrm{cm}^2$ for a 41 GeV/$c^2$ WIMP, improving sensitivity up to 1.8 times over the first campaign.
arXivarXiv · · February 25, 2025
0
221
Low-Energy Nuclear Recoil Calibration of XENONnT with a 88^{88}YBe Photoneutron Source
XENON CollaborationE. Aprile…A. Kopec
The XENONnT experiment calibrated its low-energy nuclear recoil response using a $^{88}$YBe photoneutron source emitting 152 keV neutrons. From 183 hours of exposure, 474 events were selected, with a background of $55 \pm 12$ accidental coincidences estimated from a dedicated Y-PVC gamma-only run and data-driven modeling. This first calibration for XENONnT yielded light and charge yields at 23 V/cm in liquid xenon for nuclear recoil energies between 0.3 keV$_{\rm NR}$ and 5.0 keV$_{\rm NR}$, supporting measurements of solar $^8$B neutrino CEνNS and searches for light dark matter below 12 GeV/c$^2$.
arXivarXiv · · December 12, 2024
0
11
The neutron veto of the XENONnT experiment: Results with demineralized water
XENON CollaborationE. Aprile…A. Kopec
The XENONnT experiment uses a gadolinium-doped water Cherenkov neutron veto (NV) to suppress radiogenic neutron backgrounds in its direct dark-matter search. In its initial phase with demineralized water, the NV achieves a neutron detection efficiency of $(82\pm 1)\%$, the highest reported in a water Cherenkov detector, and tags WIMP-like neutron signals with $(53\pm 3)\%$ efficiency within a $250\,\mu\mathrm{s}$ coincidence window, incurring only $1.6\%$ livetime loss.
arXivarXiv · · December 6, 2024
0
31
Search for Light Dark Matter in Low-Energy Ionization Signals from XENONnT
E. AprileJ. Aalbers…A. Kopec
Using low-energy ionization signals from the first science run of XENONnT, the collaboration reports a blinded search for dark matter via a novel detector response framework. They derive 90% confidence upper limits on dark matter–electron interactions for both heavy and light mediators under the standard halo model and solar up-scattering. The results set stringent new limits on electron scattering (mass within 10–20 MeV/$c^2$) and on electron absorption of axion-like particles and dark photons for $m_\chi$ below 0.186 keV/$c^2$.
arXivarXiv · · November 22, 2024
0
67
The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
XLZD CollaborationJ. Aalbers…A. Kopec
The XLZD Design Book presents the baseline design for a next-generation liquid xenon observatory with a 60‑tonne active target (expandable to 80 tonnes), building on the mature time projection chamber technology of LZ and XENONnT. The primary contribution is its projected sensitivity to dark matter and neutrino physics: it can probe WIMP-nucleon cross sections down to $3\times10^{-49}\text{ cm}^2$ at 40 GeV/$c^2$ with $3\sigma$ evidence potential, detect neutrinoless double beta decay of $^{136}$Xe up to a half-life of $5.7\times10^{27}$ years, and observe astrophysical neutrinos.
arXivarXiv · · October 22, 2024
0
108
Model-independent searches of new physics in DARWIN with a semi-supervised deep learning pipeline
J. AalbersK. Abe…A. Kopec
This paper presents a semi-supervised deep learning pipeline for model-independent, likelihood-free searches for anomalous events in the proposed DARWIN experiment. The pipeline combines a variational autoencoder and a classifier to produce a one-dimensional anomaly score optimized to reject the background-only hypothesis in the presence of non-background-like events. Benchmarked on a simulated WIMP signal, it outperforms the classical likelihood-based approach. The method uses low-level, high-dimensional detector outputs directly, avoiding data compression and reducing information loss.
arXivarXiv · · October 1, 2024
0
0
First Search for Light Dark Matter in the Neutrino Fog with XENONnT
E. AprileJ. Aalbers…A. Kopec
XENONnT searches for light dark matter (DM) in the mass range [3,12] GeV/$c^2$ using a 3.51 t$\times$y exposure. With a lowered energy threshold, a blind analysis of [0.5,5.0] keV nuclear recoil events finds no significant excess. The experiment excludes spin-independent DM-nucleon cross sections above $2.5\times10^{-45}$ cm$^2$ at 90% confidence for 6 GeV/$c^2$ DM, approaching the neutrino fog where solar neutrinos mimic light DM signals.
arXivarXiv · · September 26, 2024
0
72
XENONnT Analysis: Signal Reconstruction, Calibration and Event Selection
XENON CollaborationE. Aprile…A. Kopec
This paper presents the foundational framework for the blind analysis of XENONnT data, focusing on signal reconstruction, calibration, and event selection. The experiment achieved an exceptionally low background of (15.8 ± 1.3) events/(tonne·year·keV) in the (1, 30) keV region, enabling sensitive searches for dark matter WIMPs. Using one tonne·year of exposure from 2021, the work details the detector calibration and selection procedures that underpin the reporting of physics results.
arXivarXiv · · September 13, 2024
0
54
First Indication of Solar 8^8B Neutrinos via Coherent Elastic Neutrino-Nucleus Scattering with XENONnT
E. AprileJ. Aalbers…A. Kopec
The XENONnT dark matter experiment reports the first measurement of solar neutrino-induced nuclear recoils via coherent elastic neutrino-nucleus scattering (CEνNS). Using a 3.51 t·yr exposure in a low-background liquid xenon time projection chamber, a blind analysis observes 37 events above 0.5 keV, rejecting the background-only hypothesis at 2.73σ. The measured $^8$B neutrino flux of $(4.7^{+3.6}_{-2.3})\times10^6\,\mathrm{cm}^{-2}\mathrm{s}^{-1}$ and the flux-weighted CEνNS cross section of $(1.1^{+0.8}_{-0.5})\times10^{-39}\,\mathrm{cm}^2$ on Xe are consistent with Standard Model predictions and Sudbury Neutrino Observatory results.
arXivarXiv · · August 6, 2024
0
Offline tagging of radon-induced backgrounds in XENON1T and applicability to other liquid xenon detectors
E. AprileJ. Aalbers…A. Kopec
The paper presents the first software tagging algorithm for reducing radon-induced backgrounds in liquid xenon detectors, applied to XENON1T. By mapping the convection velocity field ($0.30 \pm 0.01$ cm/s RMS) using $^{222}\text{Rn}$ and $^{218}\text{Po}$ events, the algorithm tags $^{214}\text{Pb}$ background events when they are spatially correlated with subsequent $^{214}\text{Bi}$/$^{214}\text{Po}$ or preceding $^{218}\text{Po}$ decays, evolving a point cloud along the convection field. In XENON1T, this achieved a $6.2^{+0.4}_{-0.9}\%$ background reduction with $1.8\pm 0.2\%$ exposure loss. Performance is expected to improve in XENONnT and diffusion-limited scenarios. The method may also apply to tagging $^{137}\text{Xe}$ for neutrinoless double-beta decay searches.
arXivarXiv · · March 21, 2024
0
Design and performance of the field cage for the XENONnT experiment
E. AprileK. Abe…A. Kopec
The XENONnT experiment uses a double-array field cage with two nested rings and an independently biased top ring, adding a tunable degree of freedom. Finite-element simulations optimized the cage and were compared with calibration data, revealing a constant charge accumulation on TPC panels. The simulated field corrected the charge signal for field-dependent yield, resolving inconsistent drift electron lifetime measurements from different calibration sources and tuning voltages.
arXivarXiv · · September 21, 2023
0
33
Cosmogenic background simulations for the DARWIN observatory at different underground locations
M. AdroverL.Althueser…A. Kopec
This study uses Monte Carlo simulations to model the dominant cosmogenic backgrounds for the DARWIN observatory (a 40 t liquid‑xenon TPC) at four underground laboratories: LNGS, SURF, LSM, and SNOLAB. The main contribution is the determination of production rates for unstable xenon isotopes and tritium from muon-induced neutron fluxes and spallation, which are the most relevant backgrounds for site selection.
arXivarXiv · · June 28, 2023
0
Search for events in XENON1T associated with Gravitational Waves
XENON CollaborationE. Aprile…A. Kopec
A blind search for particle signals in the XENON1T detector, timed within ±500 seconds of five gravitational wave events from LIGO/Virgo, found no coincident signal. Using the null result, the strongest new upper limits are set on the fluence of mono-energetic neutrinos down to 17 keV at 90% confidence from the binary neutron star merger GW170817. Additionally, for Beyond Standard Model particles in the 5.5–210 keV range, the product of fluence and cross section is constrained to less than $10^{-29}$ cm²/cm² at 90% confidence.
arXivarXiv · · June 20, 2023
0
3
Searching for Heavy Dark Matter near the Planck Mass with XENON1T
E. AprileK. Abe…A. Kopec
This work reports a blind search for Multiply-Interacting Massive Particles (MIMPs) using 219.4 days of XENON1T data. The unique track signature of these heavy dark matter candidates, with masses near the Planck scale, enabled a targeted analysis with only 0.05 expected background events from muons. No signal candidates were observed, yielding strong constraints on spin-independent interactions for masses between $1\times10^{12}\,\text{GeV}/c^2$ and $2\times10^{17}\,\text{GeV}/c^2$ and the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross-sections.
arXivarXiv · · April 21, 2023
0
36
Detector signal characterization with a Bayesian network in XENONnT
XENON CollaborationE. Aprile…A. Kopec
We present a Bayesian network model trained on waveform attributes from a dual-phase xenon time projection chamber, which produces a quantitative metric that distinguishes scintillation from ionization signals. Applied to electronic-recoil data from XENONnT's first science run, this method achieves a 3% increase in event-selection efficiency while maintaining effective rejection of out-of-interest events, marking the first use of a Bayesian network in waveform-based detector signal analysis.
arXivarXiv · · April 11, 2023
0
14
First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
XENON CollaborationE. Aprile…A. Kopec
The XENONnT experiment, using a 5.9 t two-phase xenon time projection chamber, performed its first blind search for WIMP nuclear recoils. With unprecedentedly low $^{85}$Kr and $^{222}$Rn backgrounds, an electronic recoil rate of $(15.8\pm1.3)~\mathrm{events}/(\mathrm{t\cdot y \cdot keV})$ was achieved. No significant excess was found in the 3.3–60.5 keV energy range, yielding a 90% CL upper limit on the spin-independent WIMP-nucleon cross section of $2.58\times 10^{-47}~\mathrm{cm}^2$ at $28~\mathrm{GeV}/c^2$, improving on XENON1T results for the same exposure.
arXivarXiv · · March 26, 2023
0
943
The Triggerless Data Acquisition System of the XENONnT Experiment
E. AprileJ. Aalbers…A. Kopec
The XENONnT experiment's triggerless data acquisition (DAQ) system digitizes signals from 698 photomultiplier tubes across three subsystems—TPC, muon veto, and neutron veto—using commercial hardware and custom software. It stores every signal above digitization thresholds, enabling live monitoring within ~10 seconds. The system has operated with >99% livetime in normal runs, withstanding readout rates exceeding ~500 MB/s during calibration, and has collected over 2 PB of data.
arXivarXiv · · December 21, 2022
0
37
Effective field theory and inelastic dark matter results from XENON1T
E. AprileK. Abe…A. Kopec
Using 1 tonne×year exposure from XENON1T, this work searches for dark matter through chiral effective field theory (ChEFT) up to dimension-eight operators and an inelastic dark matter (iDM) model. The data are consistent with background, with a maximum local significance of 1.7σ for the $VV_s$ ChEFT channel at 70 GeV/$c^2$ and 1.8σ for iDM at 50 GeV/$c^2$ with a 100 keV/$c^2$ mass splitting. 90% CL upper limits are reported, and for ChEFT benchmark models, isospin-breaking interactions cause rate-driven cancellations that weaken limits by up to six orders of magnitude.
arXivarXiv · · October 14, 2022
0
27
An approximate likelihood for nuclear recoil searches with XENON1T data
E. AprileK. Abe…A. Kopec
We present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search, constructed in bins of reconstructed energy and profiled along the signal expectation in each bin. This method applies to any nuclear recoil spectrum and computes approximate results about three orders of magnitude faster than the original likelihood. We also provide binwise likelihoods for the upcoming XENONnT experiment, derived from toy Monte Carlo simulations, to assess sensitivity in its 20 tonne-year exposure.
arXivarXiv · · October 13, 2022
0
6
Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors
Carl Eric DahlRoxanne Guenette…A. Kopec
This report identifies five key R&D directions for noble element detectors (gaseous, liquid, or solid phases) used in neutrino, dark matter, and collider experiments. The central message is that enhancing and combining existing scintillation and electron-drift modalities, while developing new signal-detection methods (ion drift, metastable fluids, solid-phase detectors, dissolved targets), is essential to increase signal-to-noise, reconstruction fidelity, and physics reach. Scaling challenges (purification, background mitigation, large-area readout, magnetization) and improved microphysics understanding are also needed, alongside training the next generation through fast-turnaround projects.
arXivarXiv · · August 23, 2022
0
2
Search for New Physics in Electronic Recoil Data from XENONnT
E. AprileK. Abe…A. Kopec
The XENONnT dark matter experiment reports a blinded analysis of low-energy electronic-recoil data from its first science run. With a 5.9-tonne liquid xenon target and novel subsystems, it achieved the lowest background ever in a dark matter detector, $(15.8 \pm 1.3)$ events/(tonne$\times$year$\times$keV) in the (1, 30) keV search region, about five times lower than XENON1T. From 1.16 tonne-years of exposure, no excess above background is observed, leading to new stringent limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.
arXivarXiv · · July 22, 2022
0
558
Double-Weak Decays of 124^{124}Xe and 136^{136}Xe in the XENON1T and XENONnT Experiments
E. AprileK. Abe…A. Kopec
Using XENON1T data, the collaboration reports the first measurement of the double-electron-capture half-life of $^{124}$Xe: $T_{1/2}^{2\nu\text{ECEC}}=(1.1\pm0.2_{\text{stat}}\pm0.1_{\text{sys}})\times 10^{22}$ yr with $7.0\,\sigma$ significance. No signal for $^{136}$Xe neutrinoless double-beta decay is found, yielding a lower limit $T_{1/2}^{0\nu\beta\beta}>1.2\times10^{24}$ yr at 90% CL, the best from a dark-matter detector without enriched target. Projected XENONnT sensitivity for a $275$ kg$\cdot$yr $^{136}$Xe exposure is $>2.1\times10^{25}$ yr, corresponding to $\langle m_{\beta\beta}\rangle<(0.19-0.59)$ eV/$c^2$.
arXivarXiv · · May 9, 2022
0
Frequent collaborators
K. Ni (44)
W. Fulgione (43)
J. Ye (43)
E. Aprile (42)
L. Baudis (42)
R. Budnik (42)
J. Conrad (42)
P. Di Gangi (42)
S. Diglio (42)
A. Elykov (42)
L. Grandi (42)
M. Iacovacci (42)