MCP
AL

A. Laing

56 papers in the library

Papers

30
Ba2+^{2+} ion trapping by organic submonolayer: towards an ultra-low background neutrinoless double beta decay detector
P. Herrero-GómezJ.P. Calupitan…A. Laing
The paper demonstrates that Ba$^{2+}$ ions can be chelated in vacuum by an organic fluorescent bicolour indicator (FBI) molecule immobilized on a surface, using surface science techniques on Au(111). This trapping mechanism is also shown to work on a technologically relevant substrate, establishing the feasibility of using FBI molecules as building blocks for a Ba$^{2+}$ detector. Such a detector could tag the Ba$^{2+}$ dication produced in neutrinoless double beta decay of $^{136}$Xe, potentially enabling a nearly background-free experiment.
arXivarXiv · · January 22, 2022
0
Measurement of the 136{}^{136}Xe two-neutrino double beta decay half-life via direct background subtraction in NEXT
NEXT CollaborationP. Novella…A. Laing
The NEXT collaboration reports a measurement of the ${}^{136}$Xe two-neutrino double beta decay half-life using a novel direct background subtraction technique. By comparing data from NEXT-White with ${}^{136}$Xe-enriched and -depleted xenon, and leveraging the topology of double-electron tracks, they disentangle signal from background without relying on a background model. From a fiducial mass of 3.5 kg of Xe, they obtain a half-life of $2.34^{+0.80}_{-0.46}\mathrm{(stat)}^{+0.30}_{-0.17}\mathrm{(sys)}\times10^{21}~\mathrm{yr}$, demonstrating the feasibility of background-model-independent neutrinoless double beta decay searches.
arXivarXiv · · November 22, 2021
0
The Dynamics of Ions on Phased Radio-frequency Carpets in High Pressure Gases and Application for Barium Tagging in Xenon Gas Time Projection Chambers
NEXT CollaborationB.J.P. Jones…A. Laing
This paper develops new analytic and computational methods for modeling radio-frequency (RF) carpet ion transport in gases at atmospheric pressures and above, where buffer gas collisions dominate. The central contribution is an analytic description of levitating and sweeping forces from phased arrays, combined with thermodynamic and kinetic principles to calculate ion loss rates. Validation against SIMION simulations is provided, and the method is applied to transport barium ions in xenon (1–10 bar) for neutrinoless double beta decay experiments, revealing challenges with current manufacturing techniques.
arXivarXiv · · September 8, 2021
0
16
Demonstration of background rejection using deep convolutional neural networks in the NEXT experiment
NEXT CollaborationM. Kekic…A. Laing
This paper demonstrates that deep convolutional neural networks (CNNs) can improve background rejection for neutrinoless double-beta decay searches in the NEXT experiment. Using 2.6-MeV gamma rays from a $^{228}$Th source in a high-pressure xenon TPC, the authors created electron-positron pair production events with a topology similar to the signal. By training on Monte Carlo simulations with on-the-fly data augmentation, the CNN became robust to simulation-data differences, achieving better signal efficiency and background rejection than previous non-CNN-based methods.
arXivarXiv · · September 22, 2020
0
54
Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air
S. GhoshJ. Haefner…A. Laing
This paper measures the dependence of polytetrafluoroethylene (PTFE) diffuse reflectance on thickness in air at 260 nm and 450 nm. For thicknesses from 5 mm to 10 mm, reflectance ranges from 90.0% to 92.0% at 260 nm and 92.5% to 94.5% at 450 nm. Spatial variation within a single piece of PTFE can reach 2.7%. Placing a specular reflector behind the PTFE recovers visible reflectance loss without adding a specular component.
arXivarXiv · · July 13, 2020
0
18
Sensitivity of the NEXT experiment to Xe-124 double electron capture
G. Martínez-LemaM. Martínez-Vara…A. Laing
The NEXT collaboration reports the sensitivity of its NEXT-White detector to the two-neutrino double electron capture ($2\nu ECEC$) of $^{124}$Xe, a Standard-Model-allowed process relevant as a benchmark for a future neutrinoless mode search. Using simulated $2\nu ECEC$ signal events and real background data from NEXT-White operated with $^{124}$Xe-depleted gas, an optimal event selection is defined. The analysis extrapolates to NEXT-100, showing that with 1 kg of $^{124}$Xe-enriched xenon over 5 years, a sensitivity to the $2\nu ECEC$ half-life of $6 \times 10^{22}$ y (90% confidence level) can be achieved.
arXivarXiv · · June 12, 2020
0
10
Radiogenic backgrounds in the NEXT double beta decay experiment
NEXT CollaborationP. Novella…A. Laing
This paper characterizes radiogenic backgrounds in the NEXT double beta decay experiment using 37.9 days of data from NEXT-White. A total background rate of (0.84±0.02) mHz above 1000 keV is measured. Radon abatement shows airborne-Rn contribution is negligible. A spectral fit to a radiopurity-based model identifies specific contributions from ⁶⁰Co, ⁴⁰K, ²¹⁴Bi, and ²⁰⁸Tl to this rate. After topological cuts, the rate reduces to (0.25±0.01) mHz, enabling a 3.5σ median sensitivity to two-neutrino double beta decay after one year. In a Q_ββ±100 keV window, only one event is observed against (0.75±0.12) expected, validating the model for NEXT-100.
arXivarXiv · · May 31, 2019
0
43
Demonstration of the event identification capabilities of the NEXT-White detector
NEXT CollaborationP. Ferrario…A. Laing
The NEXT-White detector, the first underground detector of the NEXT experiment, demonstrates its ability to identify double-electron events from single-electron backgrounds using a topological cut. With a \TO\ calibration source producing events near 1.6 MeV, the cut achieves a signal efficiency of $71.6\%$ for a background acceptance of $20.6\%$, matching Monte Carlo simulations. Simulated extrapolation to the 0νββ region further improves background rejection over lower energies, enhancing experimental sensitivity.
arXivarXiv · · May 30, 2019
0
46
Electron Drift and Longitudinal Diffusion in High Pressure Xenon-Helium Gas Mixtures
A.D. McDonaldK. Woodruff…A. Laing
This paper reports new measurements of electron drift velocity and longitudinal diffusion coefficients in pure xenon and xenon-helium gas mixtures, at 1--9 bar and 50--300 V/cm. In pure xenon, excellent agreement with world data is found for both quantities at all $E/P$, except that a larger longitudinal diffusion coefficient than theory appears at low $E/P$. A similar effect occurs in mixtures at somewhat higher $E/P$. While drift velocities in mixtures are well predicted, longitudinal diffusion exceeds predictions, but extrapolation indicates that helium additives remain promising for reducing transverse diffusion.
arXivarXiv · · February 14, 2019
0
34
Study of the loss of Xenon Scintillation in Xenon-Trimethylamine Mixtures
A. M. F. TrindadeJ. Escada…A. Laing
This study tests whether TMA (trimethylamine) can shift xenon's VUV scintillation (160–188 nm) to a longer wavelength (260–350 nm). Using a Xe lamp, gas mixtures at 800 Torr, and bandpass filters, no re-emission was detected; if any occurs, it is below 0.3% of the absorbed scintillation. An absorption coefficient of $0.43 \pm 0.03 \text{ cm}^{-1}\text{Torr}^{-1}$ for Xe VUV light by TMA was measured. These results are relevant for experiments considering TMA as a molecular additive in large xenon optical time projection chambers.
arXivarXiv · · December 13, 2018
0
11
Initial results on energy resolution of the NEXT-White detector
J. RennerP. Ferrario…A. Laing
The NEXT-White detector, an electroluminescent high-pressure xenon TPC, demonstrates an energy resolution that extrapolates to approximately 1% FWHM at $Q_{\beta\beta}$ for high-energy tracks. This result is based on energy calibrations with $^{137}$Cs and $^{232}$Th sources from a long run in 2017, showing excellent linearity in response.
arXivarXiv · · August 6, 2018
0
27
Electroluminescence TPCs at the thermal diffusion limit
C.A.O. HenriquesC.M.B. Monteiro…A. Laing
The NEXT experiment searches for neutrinoless double-beta decay using a xenon TPC, where pattern recognition of primary ionization tracks is limited by electron diffusion. Adding molecular gases reduces diffusion but may compromise electroluminescence (EL) yield and energy resolution. This work measures EL yield and energy resolution for Xe with CO₂, CH₄, or CF₄ additives. CF₄ gives the highest EL yield but poor energy resolution due to large fluctuations; CH₄ offers the best energy resolution despite the lowest EL yield. Extrapolating to NEXT-100, CH₄ shows the best performance, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%.
arXivarXiv · · June 15, 2018
0
46
The electronics of the energy plane of the NEXT-White detector
V. ÁlvarezV. HerreroR. EsteveA. LaingJ. RodríguezM. QuerolF. MonrabalJ.F. ToledoJ.J. Gómez-Cadenas
The paper describes the electronics for the photomultiplier (PMT) plane of the NEXT-White detector, a high-pressure xenon TPC measuring event energy. To meet a sub-1% energy resolution and strict radiopurity, the design uses a grounded cathode connection that introduces AC coupling and baseline variations. The central contribution is a digital baseline restoration method that compensates for these effects, achieving linearity better than 0.4% and noise below 0.4 mV in the final PMT channel.
arXivarXiv · · May 21, 2018
0
9
The Next White (NEW) detector
F. MonrabalJ.J. Gómez-CadenasJ.F. ToledoV. ÁlvarezJ.M. Benlloch-RodríguezS. CárcelJ.V. CarriónR. EsteveR. FelkaiV. HerreroA. LaingA. Martínez  +63
The NEXT-White (NEW) detector is a high-pressure xenon gas time projection chamber (TPC) with electroluminescent amplification, serving as the largest such detector and a 1:2 scale model of the future NEXT-100 detector for searching $\beta\beta 0\nu$ decays in 136Xe. It operates with 5 kg of xenon at 15 bar, using a photomultiplier plane behind the transparent cathode for energy measurement and a silicon photomultiplier plane behind the anode for charged track reconstruction, supported by a shared gas system ensuring high purity. The detector has been active since October 2017 at the Canfranc Underground Laboratory, Spain, and this paper details its design and infrastructure.
arXivarXiv · · April 6, 2018
0
76
Electron drift properties in high pressure gaseous xenon
NEXT CollaborationA. Simón…A. Laing
The NEXT-White high-pressure xenon gas TPC, operating at 7.2 and 9.1 bar, was used to measure electron drift velocity and longitudinal and transverse diffusion via $^{83m}$Kr decays. These drift parameters, obtained for a range of reduced drift fields, agree with Magboltz simulations at the 5% level or better, validating the detector's tracking capabilities.
arXivarXiv · · April 5, 2018
0
22
Calibration of the NEXT-White detector using 83mKr^{83m}\mathrm{Kr} decays
G. Martínez-LemaJ.A. Hernando MorataB. PalmeiroA. BotasP. FerrarioF. MonrabalA. LaingJ. RennerA. SimónJ.J. Gómez-CadenasC. AdamsV. Álvarez  +65
Using $^{83m}\mathrm{Kr}$ decays, the NEXT-White detector’s drift-electron lifetime and position-dependent energy variations are corrected via calibration maps. The resulting energy resolution at 41.5 keV is (4.553 ± 0.010 (stat.) ± 0.324 (sys.))% FWHM in the full chamber and (3.804 ± 0.013 (stat.) ± 0.112 (sys.))% FWHM in a fiducial volume. Scaling by $1/\sqrt{E}$ gives corresponding resolutions at the $Q_{\beta\beta}$ energy of xenon double beta decay (2458 keV) of (0.516 ± 0.0014 (stat.) ± 0.0421 (sys.))% FWHM and (0.4943 ± 0.0017 (stat.) ± 0.0146 (sys.))% FWHM, well within the 1% target.
arXivarXiv · · April 5, 2018
0
Demonstration of Single Barium Ion Sensitivity for Neutrinoless Double Beta Decay using Single Molecule Fluorescence Imaging
A.D.McDonaldB.J.P. Jones…A. Laing
This paper demonstrates a new method for tagging the barium daughter in neutrinoless double beta decay of $^{136}$Xe by using single molecule fluorescent imaging (SMFI). Individual Ba$^{++}$ ions are resolved at a transparent scanning surface, confirmed by a single-step photo-bleach, and localized with super-resolution (~2 nm) at a statistical significance of 12.9$\sigma$ over backgrounds. This result lays the foundation for a potentially background-free technology combining SMFI with high-pressure xenon gas time projection chambers.
arXivarXiv · · November 13, 2017
0
104
Radiopurity assessment of the energy readout for the NEXT double beta decay experiment
S. CebriánJ. Pérez…A. Laing
The NEXT experiment, searching for neutrinoless double beta decay of $^{136}\mathrm{Xe}$, requires ultra-low background conditions. This work reports the radiopurity assessment of the energy readout plane, performed via gamma-ray spectroscopy with germanium detectors at the Laboratorio Subterráneo de Canfranc. All photomultiplier units of the selected model, along with most base, enclosure, and window components, were screened. The measured activities yield a total background contribution of at most $2.4 \times 10^{-4}$ counts keV$^{-1}$ kg$^{-1}$ y$^{-1}$ in the region of interest, confirming that the energy plane meets the experiment's sensitivity requirements.
arXivarXiv · · June 19, 2017
0
31
Application and performance of an ML-EM algorithm in NEXT
NEXT CollaborationA. Simón…A. Laing
The NEXT experiment aims to observe neutrinoless double beta decay in $^{136}$Xe using a gaseous TPC. This paper applies the Maximum Likelihood Expectation Maximization (ML-EM) algorithm to reconstruct transverse event projections from time-integrated photosensor signals. Applied to simulation data, the method achieves nearly optimal energy resolution (better than 0.5% FWHM at the $^{136}$Xe Q value) for events across the full active TPC volume.
arXivarXiv · · May 29, 2017
0
4
Microscopic simulation of xenon-based optical TPCs in the presence of molecular additives
C.D.R. AzevedoD. Gonzalez-Diaz…A. Laing
We present a simulation framework for electron transport in xenon-based optical time projection chambers (OTPCs) that includes elementary cross sections and the reaction/quenching rates of the first 41 excited states of xenon and their associated excimers, enabling computation of gas scintillation. The framework reproduces observations in pure xenon and its mixtures with CO$_2$ and CF$_4$ at pressures from 0.1 to 10 bar, clarifying the primary and secondary scintillation mechanisms in the presence of molecular additives relevant to OTPC technology.
arXivarXiv · · May 26, 2017
0
41
Secondary scintillation yield of Xenon with sub-percent levels of CO2 additive: efficiently reducing electron diffusion in HPXe optical TPCs for rare-event detection
C.A.O. HenriquesE.D.C. Freitas…A. Laing
Adding sub-percent CO2 to xenon reduces electron diffusion from ~10 mm/√m to ~2.5 mm/√m in high-pressure Xe optical TPCs, while preserving high electroluminescence (EL) yield – 70% and 35% of pure xenon at 0.05% and 0.1% CO2, respectively. For concentrations below 0.1% CO2, statistical fluctuations in EL production contribute less to energy resolution than the Fano factor. This makes Xe-CO2 mixtures a viable alternative to pure xenon for rare-event detection, improving event discrimination via topology pattern recognition.
arXivarXiv · · April 5, 2017
0
Background rejection in NEXT using deep neural networks
NEXT CollaborationJ. Renner…A. Laing
Deep neural networks trained on simulated event topologies in a high-pressure xenon time projection chamber distinguish neutrinoless double beta decay signal from background. The networks provide an additional rejection factor with acceptable efficiency loss and outperform previous topological methods by a factor of 1.2 to 1.6, with potential for further improvement.
arXivarXiv · · September 20, 2016
0
79
Sensitivity of NEXT-100 to neutrinoless double beta decay
NEXT CollaborationJ. Martín-Albo…A. Laing
NEXT-100, a high-pressure xenon gas time projection chamber with electroluminescence, aims to detect the neutrinoless double beta decay of Xe-136. Its energy resolution (<1% FWHM at the Q-value) and track reconstruction capability enable signal-background discrimination. Material screening and Monte Carlo simulations predict a background rate ≤4×10⁻⁴ counts keV⁻¹ kg⁻¹ yr⁻¹. The detector will achieve a sensitivity to the half-life of 2.8×10²⁵ years (90% CL) for 100 kg·yr exposure, or 6.0×10²⁵ years after 3 effective years.
arXivarXiv · · November 30, 2015
0
172
First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment
NEXT CollaborationP. FerrarioA. LaingN. López-MarchJ.J. Gómez-CadenasV. ÁlvarezC.D.R. AzevedoF.I.G. BorgesS. CárcelS. CebriánA. CerveraC.A.N. Conde  +58
The NEXT experiment uses a high-pressure xenon gas TPC with electroluminescence amplification to search for neutrinoless double beta decay. This paper's first demonstration, using data from the NEXT-DEMO prototype, shows that event topology reconstruction provides an extra background rejection handle. Algorithms developed on single electrons (from $^{22}$Na gammas) and electron-positron pairs (from $^{228}$Th) achieve a background rejection factor of $24.3 \pm 1.4\%$ while maintaining $66.7 \pm 1\%$ signal efficiency.
arXivarXiv · · July 21, 2015
0
104
Radon and material radiopurity assessment for the NEXT double beta decay experiment
S. CebriánJ. Pérez…A. Laing
The NEXT double-beta-decay experiment uses a high-pressure xenon TPC enriched in $^{136}$Xe, operating at the Canfranc Underground Laboratory. To achieve ultra-low background, an extensive material screening campaign based on gamma-ray spectroscopy with germanium detectors and mass spectrometry (GDMS, ICPMS) has been conducted. Components from shielding, pressure vessel, electroluminescence and high-voltage elements, and readout planes were analyzed, informing the final design and background model. In-situ radon measurements at the NEW detector further guided radon mitigation.
arXivarXiv · · May 26, 2015
0
17
Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres
Diego Gonzalez-DiazV. Alvarez…A. Laing
A 10-atm Xe/TMA time projection chamber achieves ultra-low electron diffusion (1.3 mm longitudinal, 0.8 mm transverse sigma over 1 m drift) using 1% trimethylamine. The TPC, containing 1.1 kg of gas, operated continuously for 100 days with Micromegas readout, providing 3D voxelization of 8 mm × 8 mm × 1.2 mm for approximately 10 cm/MeV electron tracks. The work focuses on calorimetric and topological properties of reconstructed MeV-electron tracks for the NEXT 0νββ decay search.
arXivarXiv · · April 14, 2015
0
An improved measurement of electron-ion recombination in high-pressure xenon gas
NEXT CollaborationL. Serra…A. Laing
Using the NEXT-DEMO prototype of a high-pressure xenon gas TPC, this work measures event-by-event correlated fluctuations between ionization and scintillation from electron-ion recombination during alpha decays. The measured correlation coefficients range from -0.80 to -0.56 depending on drift field conditions. Combining both signals yields a 2.8% FWHM energy resolution at 5.49 MeV, enabling the measurement of the average ratio of excited to ionized atoms, $0.561\pm 0.045$, corresponding to an average energy per primary scintillation photon of $W_{\rm ex}=(39.2\pm 3.2)$ eV.
arXivarXiv · · December 11, 2014
0
18
Results of the material screening program of the NEXT experiment
T. DafniV. Alvarez…A. Laing
The NEXT experiment, which searches for neutrinoless double beta decay, conducts a material screening program to achieve extremely low background levels. Combining several techniques, including germanium gamma-ray spectrometry at the Canfranc Underground Laboratory, the program assesses the radioactivity of components. The paper presents recent results of this screening and selection process.
arXivarXiv · · November 5, 2014
0
9
Ionization and scintillation of nuclear recoils in gaseous xenon
J. RennerV. M. Gehman…A. Laing
The first simultaneous measurement of ionization and scintillation from nuclear recoils in gaseous xenon at ~14 bar is reported using an electroluminescent time projection chamber. Neutron sources induced xenon recoils, and the observed spectra match a Monte Carlo simulation based on estimated yields. The ratio of ionization to primary scintillation demonstrates electronic/nuclear recoil discrimination, supporting further investigation of gaseous xenon for dark matter direct detection.
arXivarXiv · · September 9, 2014
0
25
Characterisation of NEXT-DEMO using xenon Kα_α X-rays
NEXT CollaborationD. LorcaJ. Martín-AlboA. LaingP. FerrarioJ.J. Gómez-CadenasV. ÁlvarezF.I.G. BorgesM. CamargoS. CárcelS. CebriánA. Cervera  +54
The NEXT-DEMO prototype, a high-pressure xenon gas TPC for neutrinoless double-beta decay searches, is characterised using xenon K$_\alpha$ X-rays produced during data taking. The K$_\alpha$ deposits are used to measure electron drift properties, assess the electroluminescence production region, and extract position-dependent correction constants. These constants equalise the detector's response to $^{22}$Na gamma deposits, improving energy measurement consistency.
arXivarXiv · · July 15, 2014
0
46
Frequent collaborators
M. Sorel (44)
F. Monrabal (39)
R. Esteve (39)
P. Ferrario (38)
A. Goldschmidt (38)
J. Hauptman (38)
L. Labarga (38)
M. Losada (38)
J. Renner (38)
L. Ripoll (38)
J. Torrent (38)
N. Yahlali (36)