MCP
AL

A. Lam

10 papers in the library

Papers

10
P-ONE-1: the first detector line of the Pacific Ocean Neutrino Experiment
O. AghaeiM. Agostini…A. Lam
This paper presents the design, integration, and testing of P-ONE-1, the first detector line of the Pacific Ocean Neutrino Experiment (P-ONE), a planned neutrino telescope in the Northeast Pacific Ocean being developed with Ocean Networks Canada (ONC) in preparation for deployment and integration into ONC's deep-sea observatory NEPTUNE. Alongside the detector design and integration methods, the authors detail in-air and in-water system-level validation at several Canadian test sites, culminating in the successful construction of P-ONE-1 and its preparation for deployment.
arXivarXiv · · October 20, 2026
1
Characterization of the R14374-10 photomultiplier tube for the Pacific Ocean Neutrino Experiment
O. AghaeiM. Agostini…A. Lam
This paper characterizes 320 Hamamatsu R14374-10 photomultiplier tubes for the first line of the Pacific Ocean Neutrino Experiment (P-ONE). All PMTs meet acceptance criteria: average transit-time spread is $1.73\pm0.15$ ns, charge resolution at gain \num{5e6} is $0.43\pm0.03$ pC, and after-pulse rate is about 6%. The integrated DAQ system was cross-validated. Detailed study of six PMTs measured linearity up to 150 photoelectrons, identified after-pulse ions, quantum efficiency of $27.0\pm0.7\%$ at 395 nm, and collection efficiency differing by a wavelength-independent offset of 10–15%.
arXivarXiv · · October 19, 2026
0
Long term study of sedimentation and biofouling at Cascadia Basin, the site of the Pacific Ocean Neutrino Experiment
O. AghaeiM. Agostini…A. Lam
Analysis of the STRAW pathfinders at the Pacific Ocean Neutrino Experiment (P-ONE) site reveals that biofouling and sedimentation reduced the optical transparency of upward-facing modules over five years, with losses modeled to begin roughly 2.5 years post-deployment and potentially reaching 35% to complete obscuration. Crucially, the downward-facing surfaces, which will dominate P-ONE's astrophysical sensitivity, remained largely unaffected, and microbial samples informed a candidate anti-biofouling strategy for future instruments.
arXivarXiv · · July 12, 2025
0
4
Not just winds: why models find binary black hole formation is metallicity dependent, while binary neutron star formation is not
L. A. C. van SonS. K. RoyI. MandelW. M. FarrA. LamJ. MerrittF. S. BroekgaardenA. SanderJ. J. Andrews
The paper finds that the metallicity dependence of double compact object (DCO) formation is primarily a question of formation channel. Binary black hole (BHBH) formation is more efficient at low metallicity because the stable mass transfer and chemically homogeneous evolution channels diminish at high metallicity due to changes in stellar radii, while the common envelope channel is most affected by stellar winds and natal kicks. Outdated giant wind prescriptions may overstate this dependence. Binary neutron star (NSNS) formation remains metallicity-independent because it proceeds exclusively through the common envelope channel with mass-uncorrelated natal kicks.
arXivarXiv · · November 4, 2024
0
3
Environmental impact assessment for climate change policy with the simulation-based integrated assessment model E3ME-FTT-GENIE
J-F MercureH. PollittN.R. EdwardsP.B. HoldenU. ChewpreechaP. SalasA. LamF. KnoblochJ. Vinuales
This paper presents the simulation-based integrated assessment model E3ME-FTT-GENIE, which combines a macro-econometric model (E3ME), a family of evolutionary technology diffusion models (FTT), and a carbon-cycle and climate model (GENIE-1). Unlike optimization-based models suitable for agenda setting, this fully descriptive model is designed specifically for climate policy impact assessment. The authors use it to produce a detailed global and sectoral policy scenario that achieves the Paris Agreement goals with >66% probability of limiting warming to 2°C.
arXivarXiv · · July 16, 2017
0
206
The 2.4 μμm Galaxy Luminosity Function as Measured Using WISE. I. Measurement Techniques
S. E. LakeE. L. WrightC.-W. TsaiA. Lam
This paper derives a statistical estimator for galaxy luminosity functions that can simultaneously analyze multiple redshift surveys, addressing color-selection biases from multi-wavelength flux limits. The key innovation is a generalization of the luminosity function $\(\Phi(L)\) over the space of all spectra, the spectro-luminosity functional $\(\Psi[L_\nu]\), the first estimator capable of consistently combining disparate surveys. Additionally, a new parametrization of the evolution of Shechter-function parameters $L_\star$ and $\phi_\star$ improves physical realism and statistical performance. These techniques will be applied to measure the $2.4\,\mu\mathrm{m}$ luminosity function using WISE data.
arXivarXiv · · April 26, 2016
0
The effectiveness of policy on consumer choices for private road passenger transport emissions reductions in six major economies
J.-F. MercureA. Lam
The paper analyzes the structure of 2012 private passenger vehicle fleets in six major economies (UK, USA, China, India, Japan, Brazil) in terms of price, engine size, and emissions distributions. It argues that consumer choices and aggregate elasticities of substitution can be predicted from these data, enabling evaluation of fiscal and technological policies for fleet-year emissions reductions. The study finds significant cross-national market differences, with correlations between engine size, emissions, and price strong in some markets but weak in others, and patchy coverage of unconventional engine technologies.
arXivarXiv · · November 10, 2014
0
58
Cryogenic instrumentation for fast current measurement in a silicon single electron transistor
T. FerrusD. G. HaskoQ. R. MorrisseyS. R. BurgeE. J. FreemanM. J. FrenchA. LamL. CreswellR. J. CollierD. A. WilliamsG. A. D. Briggs
This work presents cryogenic instrumentation that enables fast current measurement in a silicon single-electron transistor, operating at dilution refrigerator temperatures. The low-temperature electronics achieve higher measurement bandwidth than conventional room-temperature setups, demonstrated using a phosphorous-doped single-electron transistor. A single-shot technique is implemented to observe the real-time decay of a quantum state. The paper also discusses measurement strategies and their impact on electron heating and noise.
arXivarXiv · · April 21, 2009
0
11
An Improved Limit on the Muon Electric Dipole Moment
G.W.BennettB.Bousquet…A.Lam
Searches for the muon electric dipole moment (EDM) were conducted using spin precession data from the muon g-2 storage ring at Brookhaven National Laboratory. Three independent analyses of positive and negative muons yielded a combined result of $d = -0.1(0.9) \times 10^{-19}\, e\,\text{cm}$, consistent with zero. This sets a new limit of $|d| < 1.9 \times 10^{-19}\, e\,\text{cm}$ (95% C.L.), a factor of five improvement over the previous best limit.
arXivarXiv · · November 7, 2008
0
Single shot measurement of a silicon single electron transistor
D. G. HaskoT. FerrusQ. R. MorrisseyS. R. BurgeE. J. FreemanM. J. FrenchA. LamL. CreswellR. J. CollierD. A. WilliamsG. A. D. Briggs
A custom cryogenic CMOS integrated circuit achieves higher measurement bandwidth than room-temperature electronics, enabling single-shot observation of the real-time current evolution of a silicon single-electron transistor under microwave irradiation. Relaxation times up to 90 µs are observed, attributed to well-isolated electron excitations, suggesting the device may have long decoherence times and be suitable for quantum information processing.
arXivarXiv · · November 5, 2008
0
13
Frequent collaborators
O. Aghaei (3)
M. Agostini (3)
A. Alexander Wight (3)
P. S. Barbeau (3)
A. J. Baron (3)
S. Bash (3)
C. Bellenghi (3)
M. Boehmer (3)
M. Brandenburg (3)
D. Brussow (3)
N. Cedarblade-Jones (3)
B. Crudele (3)