MCP
BA

B. Aja

10 papers in the library

Papers

10
The QUIJOTE Experiment: Prospects for CMB B-MODE polarization detection and foregrounds characterization
F. PoidevinJ.A. Rubino-Martin…B. Aja
The QUIJOTE experiment combines two telescopes and three instruments observing from 10-42 GHz at Teide Observatory to detect CMB B-mode polarization, targeting a primordial gravitational-wave component with amplitude as low as $r=0.05$. Its observing strategy includes deep integration fields for cosmology, a wide survey of the northern sky, and targeted observations. The paper presents the project's goals and reviews first scientific results from the initial instrument.
arXivarXiv · · February 13, 2018
0
The QUIJOTE experiment: project overview and first results
R. Génova-SantosJ.A. Rubiño-Martín…B. Aja
The QUIJOTE experiment introduces a polarimeter operating at 10–40 GHz to characterize the polarization of the Cosmic Microwave Background and other signals at medium and large angular scales. Its central contribution is the capability to detect the B-mode polarization signature of primordial gravitational waves if the tensor-to-scalar ratio exceeds $r = 0.05$, with instruments at 10–20 GHz, 30 GHz, and 40 GHz achieving nominal sensitivities for this purpose.
arXivarXiv · · April 14, 2015
0
The QUIJOTE CMB Experiment: status and first results with the multi-frequency instrument
M. López-CaniegoR. Rebolo…B. Aja
QUIJOTE is a ground-based experiment observing CMB polarization at 10–40 GHz. Its first telescope and multi-frequency (10–20 GHz) instrument have operated since November 2012, with higher-frequency instruments planned. The projected sensitivity after three years of full operation can detect a primordial gravitational-wave component if the tensor-to-scalar ratio $r > 0.05$. Half of a wide Galactic survey covering 18,000 square degrees in the Northern hemisphere has been completed; upon completion in early 2014, the survey will reach approximately 14 $\mu$K per one-degree beam in Q and U at 11, 13, 17, and 19 GHz.
arXivarXiv · · January 19, 2014
0
14
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
A. MennellaM. Bersanelli…B. Aja
This paper assesses the in-flight performance of Planck's Low Frequency Instrument (LFI) after one year of operation. It presents the main optical parameters, photometric calibration, white noise sensitivity, and noise properties, along with a preliminary evaluation of systematic effects. The methods used to derive these parameters from flight data are outlined, and the results confirm pre-launch ground assessments.
arXivarXiv · · January 11, 2011
0
234
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
F. VillaL. Terenzi…B. Aja
This paper reports the pre-launch calibration of the eleven radiometer subsystems (RCAs) aboard the Planck Low Frequency Instrument. Each RCA, a pseudo-correlation receiver, was tested in a cryogenic environment with its front-end at 20 K and back-end at 300 K, using a variable-temperature blackbody load. Key parameters—noise temperature, gain, 1/f noise, spectral response, and thermal susceptibility—were measured. These results provide essential inputs for Planck-LFI data analysis.
arXivarXiv · · May 14, 2010
0
28
Noise Properties of the Planck-LFI Receivers
P. MeinholdR. LeonardiB. AjaE. ArtalP. BattagliaM. BersanelliE. BlackhurstC. R. ButlerL. P. CuevasF. CuttaiaO. D'ArcangeloR. Davis  +38
This paper characterizes the noise properties of the Planck Low Frequency Instrument (LFI) radiometers using extensive test campaigns. It reports the primary noise parameters, establishing the baseline performance of these receivers for the Planck mission. The work provides a foundation for understanding the instrument's sensitivity and systematic effects.
arXivarXiv · · January 26, 2010
0
42
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
R.J. DavisA. Wilkinson…B. Aja
The paper describes the design, construction, and testing of the 30 and 44 GHz front-end modules (FEMs) for the Planck Low Frequency Instrument. Each FEM is a differential pseudo-correlation radiometer comparing sky signal with a 4-K blackbody load, using an indium phosphide HEMT-based low-noise amplifier and a novel phase-switch. The FEMs meet or exceed all mission requirements, including noise temperature, stability, and linear polarization. The most sensitive amplifiers achieve noise temperatures of 3 and 5 times the quantum limit at 30 and 44 GHz band centres, respectively, setting new noise-temperature benchmarks for HEMTs.
arXivarXiv · · January 26, 2010
0
32
LFI 30 and 44 GHz receivers Back-End Modules
E. ArtalB. AjaM. L. de la FuenteJ. P. PascualA. MediavillaE. Martinez-GonzalezL. PradellP. de PacoM. BaraE. BlancoE. GarciaR. Davis  +10
This paper describes the 30 and 44 GHz Back End Modules (BEMs) for the Planck Low Frequency Instrument. These are broadband (20% relative bandwidth) room-temperature receivers that amplify, filter, and detect signals from the front end. Each BEM contains two identical branches following the Planck radiometer's differential scheme. The design uses MMIC LNAs with GaAs P-HEMT devices, microstrip filters, and Schottky diode detectors. The paper presents the modules' electrical and environmental test results, including frequency response, effective bandwidth, noise temperature, 1/f noise, and linearity.
arXivarXiv · · January 26, 2010
0
22
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
A. MennellaM. Bersanelli…B. Aja
Based on ground cryogenic tests, the Planck Low Frequency Instrument (LFI) achieves excellent $1/f$ stability and rejection of systematic effects, with measured noise performance making it the most sensitive instrument of its kind. These calibration parameters represent the best pre-launch characterization of the LFI's scientific performance and will be updated during flight operations.
arXivarXiv · · January 25, 2010
0
55
Planck pre-launch status: Design and description of the Low Frequency Instrument
M. BersanelliN. MandolesiR. C. ButlerA. MennellaF. VillaB. AjaE. ArtalE. ArtinaC. BaccigalupiM. BalasiniG. BaldanA. Banday  +100
This paper describes the design and scientific requirements of the Planck Low Frequency Instrument (LFI), a 20-K cryogenic array of differential microwave radiometers using Indium Phosphide HEMT amplifiers and 4-K blackbody reference loads. LFI will map the full sky in intensity and polarization at 30, 44, and 70 GHz to complement the higher-frequency HFI instrument in precision imaging of the cosmic microwave background.
arXivarXiv · · January 19, 2010
0
308
Frequent collaborators
E. Artal (10)
A. Mediavilla (7)
A. Mennella (7)
M. Bersanelli (7)
F. Cuttaia (7)
M. Tomasi (7)
A. Wilkinson (7)
N. Roddis (7)
L. Stringhetti (7)
R. Rebolo (6)
N. Mandolesi (6)
A. Zonca (6)