MCP
BB

B. Bumble

19 papers in the library

Papers

19
Single-photon detection in the mid-infrared up to 10 micron wavelength using tungsten silicide superconducting nanowire detectors
V. B. VermaB. KorzhA. B. WalterA. E. LitaR. M. BriggsM. ColangeloY. ZhaiE. E. WollmanA. D. BeyerJ. P. AllmarasB. BumbleH. Vora  +6
This paper presents tungsten silicide superconducting nanowire single-photon detectors (SNSPDs) that achieve saturated internal detection efficiency at wavelengths up to 10 $\mu$m, extending single-photon sensitivity into the mid-infrared. The WSi-based devices offer ultra-high gain stability, low dark counts, and high efficiency, making them suitable for demanding applications such as chemical sensing, LIDAR, dark matter searches, and exoplanet spectroscopy.
arXivarXiv · · December 17, 2020
0
0
Characterization of sputtered hafnium thin films for high quality factor microwave kinetic inductance detectors
G. CoiffardM. DaalN. ZobristN. SwimmerS. SteigerB. BumbleB. A. Mazin
This work reports that hafnium thin films deposited by DC magnetron sputtering at normal incidence, low pressure, and low plasma power grow with a compressive (002) crystal orientation. This orientation leads to high internal quality factors, up to 600,000, in microwave kinetic inductance detectors (MKIDs), making the films suitable for optical and near-infrared detection.
arXivarXiv · · April 1, 2020
0
Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy
P. SzyprytS. R. MeekerG. CoiffardN. FruitwalaB. BumbleG. UlbrichtA. B. WalterM. DaalC. BockstiegelG. ColluraN. ZobristI. Lipartito  +1
This paper demonstrates that replacing substoichiometric TiN on silicon with PtSi on sapphire in large-format microwave kinetic inductance detector arrays (up to 20,440 pixels) for optical to near-IR astronomy greatly improves pixel uniformity, spectral resolution, and eliminates hot pixel effects for photons below 1 μm, directly benefiting exoplanet imaging instruments requiring 800–1400 nm coverage.
arXivarXiv · · October 19, 2017
0
High Quality Factor Platinum Silicide Microwave Kinetic Inductance Detectors
P. SzyprytB.A. MazinG. UlbrichtB. BumbleS.R. MeekerC. BockstiegelA.B. Walter
This paper reports platinum silicide (PtSi) as a sensor material for microwave kinetic inductance detectors (MKIDs). PtSi microresonators achieve superconducting critical temperatures of $944\pm12$ mK, internal quality factors $Q_i \gtrsim 10^6$, and quasiparticle lifetimes $\tau_{qp} \approx 30$–$40$ $\mu$s. These properties yield a spectral resolution $R = 8$ at 406.6 nm, addressing the spatial inhomogeneity of TiN and low kinetic inductance fraction of Al. Compared to TiN MKIDs, PtSi MKIDs offer substantial advantages.
arXivarXiv · · October 3, 2016
0
Search for Optical Pulsations in PSR J0337+1715
M. J. StraderA. M. ArchibaldS. R. MeekerP. SzyprytA. B. WalterJ. C. van EykenG. UlbrichtC. StoughtonB. BumbleD. L. KaplanB. A. Mazin
This paper presents a search for optical pulsations from PSR J0337+1715, a millisecond pulsar (2.7 ms spin period) in a triple hierarchical system with two white dwarfs. Using the ARCONS camera on the 200-inch Hale telescope, no significant pulsations were detected in the 4000-11000 angstrom range. The authors set an upper limit: pulsed emission in g-band is fainter than 25 mag.
arXivarXiv · · March 16, 2016
0
23
A frequency and sensitivity tunable microresonator array for high-speed quantum processor readout
J. D. WhittakerL. J. SwensonM. H. VolkmannP. SpearF. AltomareA. J. BerkleyB. BumbleP. BunykP. K. DayB. H. EomR. HarrisJ. P. Hilton  +9
This paper presents a superconducting microresonator readout design that integrates two tunable inductances per detector, enabling independent control of both resonance frequency and sensitivity. This tuning capability is shown to maximize transmission line bandwidth utilization, addressing the problem of non-uniform shifts caused by fabrication tolerances. The design is also integrated into a multilayer fabrication stack for high-speed readout of the D-Wave quantum processor, using single flux-quantum loops to minimize control wires at the lowest temperature stage.
arXivarXiv · · September 18, 2015
0
26
Ultraviolet, Optical, and Near-IR Microwave Kinetic Inductance Detector Materials Developments
P. SzyprytB. A. MazinB. BumbleH. G. LeducL. Baker
This paper describes two approaches to improve the yield and energy resolution of microwave kinetic inductance detector (MKID) arrays for the ultraviolet/optical/near-IR range. As array size increases, frequency collisions in the readout reduce yield. To address this, the authors are developing more uniform titanium nitride films via atomic layer deposition instead of sputtering, and testing platinum silicide as a new material system for MKIDs.
arXivarXiv · · December 1, 2014
0
Performance of the Caltech Submillimeter Observatory Dual-Color 180-720 GHz Balanced SIS Receivers
J. W. KooiR. A. ChamberlinR. MonjeA. KovacsF. RiceH. YoshidaB. ForceK. CooperD. MillerM. GouldD. LisB. Bumble  +3
This paper describes dual-color balanced SIS receivers for the 180-720 GHz submillimeter window, using high-current-density Nb-AlN-Nb junctions and fully synthesized local oscillators. The central contribution is the measured receiver noise performance: at 230 GHz, double-sideband noise temperatures (uncorrected for optics loss) are 50 K at 185 GHz, 33 K at 246 GHz, and 51 K at 280 GHz, with a DSB conversion gain of 0 ± 1.5 dB. Similarly, at 460 GHz, noise temperatures are 32 K at 400 GHz, 34 K at 460 GHz, and 61 K at 520 GHz, with a gain of 1 ± 1 dB. The receivers also support dual-frequency observation by separating circularly polarized components and offer excellent stability via LO noise cancellation.
arXivarXiv · · February 6, 2014
0
41
Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
P. SzyprytG. E. Duggan…B. Bumble
Using ARCONS, a new type of energy-resolved photon counter, on the Palomar 200-inch telescope, we observed the eclipsing AM CVn binary SDSS J0926+3624. From the resulting light curves, a quadratic ephemeris model yields a period rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$, directly detecting orbital expansion. No high-frequency quasi-periodic oscillations or significant spectral variability across an eclipse were found.
arXivarXiv · · September 16, 2013
0
Excess Optical Enhancement Observed with ARCONS for Early Crab Giant Pulses
M. J. StraderM. D. Johnson…B. Bumble
Using ARCONS on the Palomar 200-inch telescope and the Green Bank Telescope, the authors find that Crab giant radio pulses are causally linked to optical emission. An optical pulse whose peak coincides with a giant radio pulse shows an $11.3\pm2.5\%$ increase in peak flux, whereas a radio pulse arriving just after the optical peak yields only a $3.2\pm0.5\%$ increase. No spectral differences are observed between optical pulses with and without accompanying giant radio pulses, suggesting a common optical emission mechanism.
arXivarXiv · · September 12, 2013
0
69
ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging Spectrophotometer
B.A. MazinS.R. MeekerM.J. StraderB. BumbleK. O'BrienP. SzyprytD. MarsdenJ.C. van EykenG.E. DugganG. UlbrichtC. StoughtonM. Johnson
ARCONS is the first ground-based optical-through-near-IR instrument using Microwave Kinetic Inductance Detectors (MKIDs), which count single photons and measure their energy without filters or gratings, offering noiseless detection with zero read noise and dark current. Its 2024-pixel lens-coupled array provides a 20″×20″ field of view as an integral field spectrograph. Commissioning on Palomar and Lick telescopes over 24 nights shows the instrument is fully operational for astronomical observations.
arXivarXiv · · June 19, 2013
0
209
Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors
D. C. MooreS. R. GolwalaB. BumbleB. CornellP. K. DayH. G. LeDucJ. Zmuidzinas
A phonon-mediated microwave kinetic inductance detector (MKID) array on a silicon substrate achieves position and energy-resolved particle detection. Using relative signal magnitude and delay across sensors, interaction positions are determined with sub-mm precision at 30 keV, enabling correction of position-dependent response variations. This yields an energy resolution of $\sigma_E = 0.55$ keV at 30 keV. The MKIDs’ single-film fabrication and frequency-domain multiplexing allow scaling to ~1 kg detector elements with highly-pixelized athermal phonon sensors, relevant to rare-event searches like dark matter detection.
arXivarXiv · · March 20, 2012
0
103
Herschel observations of EXtra-Ordinary Sources: The Terahertz spectrum of Orion KL seen at high spectral resolution
N. R. CrockettE. A. BerginS. WangD. C. LisT. A. BellG. A. BlakeA. BoogertB. BumbleS. CabritE. CauxC. CeccarelliJ. Cernicharo  +51
This paper presents the first high-spectral-resolution observations of Orion KL in the 1573.4–1702.8 GHz and 1788.4–1906.8 GHz bands using Herschel/HIFI. The central contribution is the characterization of the line emission, which arises primarily from the hot core and also from outflow components traced by H₂O, SO₂, and OH. A key finding is that the line density is significantly lower in these terahertz bands compared to lower-frequency Herschel/HIFI bands.
arXivarXiv · · July 26, 2010
0
Herschel observations of EXtra-Ordinary Sources: the present and future of spectral surveys with Herschel/HIFI
E. A. BerginT. G. PhillipsC. ComitoN. R. CrockettD. C. LisP. SchilkeS. WangT. A. BellG. A. BlakeB. BumbleE. CauxS. Cabrit  +47
The Herschel/HIFI instrument, with its sensitivity and continuous spectral coverage, observes the Orion KL spectrum between 480-560 GHz and 1.06-1.115 THz. It resolves emission lines separately from the dust continuum, showing that line contributions to the broad-band continuum are ~20-40% below 1 THz and decline to a few percent at higher frequencies. The survey also tentatively identifies multiple transitions of HD18O, marking the first detection of this rare isotopologue in the interstellar medium, suggesting HDO emission is optically thick in the Orion hot core with HDO/H2O ~ 0.02.
arXivarXiv · · July 13, 2010
0
0
HIFI observations of warm gas in DR21: Shock versus radiative heating
V. OssenkopfM. Röllig…B. Bumble
By analyzing Herschel/HIFI observations of mid-J CO and HCO+ isotopic lines toward DR21, this paper distinguishes shock from radiative heating. Despite the known outflow and shock-excited H2, all line emission up to >2 THz is reproduced by purely radiative heating. The data reveal two excitation regimes: hot, dense clumps near the central cluster, likely outflow-affected, and cooler but still dense clumps distributed more widely.
arXivarXiv · · May 14, 2010
0
26
Implementation of a Quantum Annealing Algorithm Using a Superconducting Circuit
R. HarrisA.J. BerkleyJ. JohanssonM.W. JohnsonT. LantingP. BunykE. TolkachevaE. LadizinskyB. BumbleA. FungA. KaulA. Kleinsasser  +1
Successfully implementing a quantum annealing algorithm on a superconducting circuit of coupled compound Josephson junction rf-SQUID flux qubits requires precise knowledge of the persistent current magnitude as a function of annealing parameters. This is demonstrated by comparing two annealing protocols—one with and one without active compensation for the persistent current growth during annealing—showing that the compensated protocol yields better optimization performance.
arXivarXiv · · March 23, 2009
0
9
Synchronization of Multiple Coupled rf-SQUID Flux Qubits
R. HarrisF. BritoA.J. BerkleyJ. JohanssonM.W. JohnsonT. LantingP. BunykE. LadizinskyB. BumbleA. FungA. KaulA. Kleinsasser  +1
This paper demonstrates a strategy to synchronize the properties of multiple coupled rf-SQUID flux qubits on a chip. Small ($\sim1\%$) fabrication variations in qubit inductance and critical current are minimized by applying a custom-tuned flux offset to each qubit's compound Josephson junction (CJJ) structure. This simultaneously synchronizes the qubit persistent current and tunnel splitting across a range of external bias parameters relevant for adiabatic quantum processors.
arXivarXiv · · March 11, 2009
0
31
Geometrical dependence of low frequency noise in superconducting flux qubits
T. LantingA.J. BerkleyB. BumbleP. BunykA. FungJ. JohanssonA. KaulA. KleinsasserE. LadizinskyF. MaibaumR. HarrisM.W. Johnson  +2
The paper measures low-frequency flux noise (below 10 Hz) in 85 superconducting flux qubits of varying design using a direct method. The noise varies systematically with qubit wiring length and width, and is lower for qubits above a superconducting ground plane. These results support the hypothesis that localized magnetic impurities near the qubit wiring are a key noise source.
arXivarXiv · · December 1, 2008
0
Probing Noise in Flux Qubits via Macroscopic Resonant Tunneling
R. HarrisM.W. JohnsonS. HanA.J. BerkleyJ. JohanssonP. BunykE. LadizinskyS. GovorkovM.C. ThomS. UchaikinB. BumbleA. Fung  +4
Macroscopic resonant tunneling in an RF-SQUID is used to probe noise in a flux qubit. The incoherent decay rate, measured as a function of flux bias, shows a Gaussian profile shifted away from the symmetry point, indicating the initial well is higher than the target well. The r.m.s. noise amplitude, proportional to $1/T_2^*$, is weakly temperature-dependent below 70 mK, suggesting that the dominant low-frequency ($1/f$) flux noise originates from a quantum mechanical environment in thermal equilibrium.
arXivarXiv · · December 6, 2007
0
113
Frequent collaborators
P. Szypryt (7)
B. A. Mazin (6)
G. Ulbricht (6)
A. B. Walter (5)
P. Bunyk (5)
R. Harris (5)
A. Kleinsasser (5)
E. Ladizinsky (5)
S. R. Meeker (4)
C. Stoughton (4)
T. Lanting (4)
A.J. Berkley (4)