MCP
BC

B. Cabrera

59 papers in the library

Papers

30
Low Frequency Noise Identification for the SuperCDMS Experiment using Convolutional Neural Networks
SuperCDMS collaborationM. F. Albakry…B. Cabrera
This paper presents a convolutional neural network (CNN) method to identify low-frequency noise (LFN) in SuperCDMS data. LFN resembles low-energy signal pulses and is hard to remove; the prior CDMSlite Run 3 event-selection criterion reduced sensitivity to low-mass dark matter. The CNN-based rejection aims to improve signal efficiency while maintaining purity. Applied to the CDMSlite Run 3 dataset, its impact on dark matter sensitivities is reported and further examined through case studies.
arXivarXiv · · October 30, 2026
0
Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB
M. F. AlbakryI. Alkhatib…B. Cabrera
For SuperCDMS SNOLAB, six new cryogenic germanium and silicon High Voltage (HV) detectors were tested at the CUTE facility. Focusing on the four germanium detectors, the study demonstrates the low-energy calibration using $^{71}$Ge electron-capture peaks (keV to sub-keV) and an unexpected ability to measure hundreds-of-keV interactions with resolution better than 3% at 356 keV under voltage bias up to 90 V. This shows the HV detector concept's expanded energy range for dark matter searches.
arXivarXiv · · June 24, 2026
0
1
Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector
SuperCDMS CollaborationM.F. Albakry…B. Cabrera
Using a SuperCDMS HVeV detector, a blind analysis of 6.1 g·days of underground exposure produced exclusion limits on dark matter-electron scattering for masses down to 1 MeV/c², and on absorption processes (photon–dark photon mixing, axionlike particle–electron coupling) for particles above 1.2 eV/c². The result improves on previous HVeV limits by reducing luminescence from the detector holder's printed circuit boards.
arXivarXiv · · September 3, 2025
1
17
Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning
M.F. AlbakryI. Alkhatib…B. Cabrera
SuperCDMS dark-matter detectors suffer from noise correlations among readout channels and position-dependent pulse shapes, both of which degrade energy resolution. The authors present a new algorithm that fits the $N$ readout channels with a superposition of $M$ pulse templates simultaneously (the $N\times M$ filter). They derive templates via PCA and use a gradient boosted decision tree for energy and position extraction. This approach reduces correlated-noise impact and improves resolution: for simulated mono-energetic events by over a factor of three, and for the 71Ge electron-capture peak in CDMSlite data from $\sim$100 eV to below 50 eV.
arXivarXiv · · August 27, 2025
0
3
Low-Energy Calibration of SuperCDMS HVeV Cryogenic Silicon Calorimeters Using Compton Steps
SuperCDMS CollaborationM. F. Albakry…B. Cabrera
The SuperCDMS HVeV collaboration demonstrates a sub-keV calibration method for cryogenic silicon calorimeters using Compton steps from gamma-ray scattering. Applied to four detectors operated at 0 V bias, the calibration reveals the detector response is about 30% weaker than expected relative to the established high-voltage optical-photon calibration, indicating challenges in modeling low-mass dark matter searches.
arXivarXiv · · August 4, 2025
0
6
Broadband Optical Modulation and Control at Millikelvin Temperatures
N. TabassumT. AralisJ. AnczarskiD. BaxterB. CabreraR. ChaplaN. EntinL. HsuH. W. MagoonA. NunezJ. L. RyanM. Salatino  +8
This paper presents a compact cryogenic optical beam steering system that delivers O(μs) pulses of few photons in the 1.2–4.5 eV range from room temperature to any specified location on a detector surface at millikelvin temperatures. The system enables robust calibration of photon-sensitive detectors, including superconducting devices, and supports studies of position sensitivity, phonon transport, and quasiparticle poisoning. First results from a second-generation system at sub-Kelvin temperatures are reported.
arXivarXiv · · April 9, 2025
0
Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
SuperCDMS CollaborationM.F. Albakry…B. Cabrera
This paper reports dark-matter-electron interaction constraints from the first underground run of multiple SuperCDMS HVeV detectors in the same housing. Using 7.63 g-days of exposure, it sets upper limits on the scattering cross section for dark matter masses 0.5–1000 MeV/$c^2$ and on dark photon and axion-like particle couplings for masses 1.2–23.3 eV/$c^2$. The 225 m water-equivalent overburden, anticoincidence selection, and improved pile-up rejection enhance sensitivity; for heavy-mediator scattering, the cross-section limit improves by up to a factor of 25 over a previous search.
arXivarXiv · · July 10, 2024
0
58
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
M.F. AlbakryI. Alkhatib…B. Cabrera
Using a cryogenic phonon-sensitive gram-scale silicon detector and a mono-energetic neutron beam, the nuclear-recoil ionization yield was measured for energy depositions from 4 keV down to 100 eV — the lowest energy probed so far. No sign of an ionization production threshold was observed above 100 eV, calling for further refinement of yield theory and detector response models below the keV scale.
arXivarXiv · · March 3, 2023
0
45
A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS
M.F. AlbakryI. Alkhatib…B. Cabrera
A new analysis of SuperCDMS data uses a profile likelihood framework to search for sub-GeV dark matter via two inelastic channels: bremsstrahlung radiation and the Migdal effect. These channels extend sensitivity to masses below the energy threshold for elastic scattering. The Migdal channel provides stronger limits, excluding masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.
arXivarXiv · · February 17, 2023
0
G4CMP: Condensed Matter Physics Simulation Using the Geant4 Toolkit
M. H. KelseyR. AgneseY. F. AlamI. Ataee LangroudyE. AzadbakhtD. BrandtR. BunkerB. CabreraY.-Y. ChangH. CoombesR. M. CormierM. D. Diamond  +35
G4CMP extends the Geant4 toolkit to simulate ballistic phonon and charge-carrier transport in cryogenic semiconductors. It models anisotropic phonon propagation, oblique charge-carrier drift, and phonon emission from accelerated carriers. The implementation reproduces theoretical predictions and experimental benchmarks such as phonon caustics, heat-pulse times, and mean drift velocities. The package is used by the dark matter and quantum information communities to design superconducting devices on silicon and germanium substrates.
arXivarXiv · · February 12, 2023
0
54
Effective Field Theory Analysis of CDMSlite Run 2 Data
SuperCDMS CollaborationM.F. Albakry…B. Cabrera
An effective field theory (EFT) analysis of CDMSlite Run 2 data, which used a 600 g Ge detector in high-voltage mode to search for low-mass WIMPs (2–20 GeV/$c^2$), is presented. A binned likelihood Bayesian analysis performed on an extended energy range, with 5σ cuts around activation peaks, found the data consistent with background-only models. No additional EFT interaction was supported. Upper limits on WIMP mass and coupling-coefficient amplitudes and phases are given for each operator, improving previous bounds for WIMP masses above 5 GeV/$c^2$.
arXivarXiv · · May 24, 2022
0
4
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
SuperCDMS CollaborationM.F. Albakry…B. Cabrera
Operating a 1-gram silicon SuperCDMS-HVeV detector at 0 V, 60 V, and 100 V bias, this work observes an excess of events in the tens of eV region at 0 V. By comparing datasets, the dominant source of this excess is attributed to luminescence from the printed circuit boards in the detector holder. Despite the excess, the 0 V data set a competitive exclusion limit on spin-independent dark matter–nucleon elastic scattering for masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by a very low $\mathcal{O}(10)$ eV nuclear recoil threshold.
arXivarXiv · · April 17, 2022
0
47
Constraints on Lightly Ionizing Particles from CDMSlite
SuperCDMS CollaborationI. Alkhatib…B. Cabrera
Using the CDMSlite germanium detector, the Cryogenic Dark Matter Search set first direct-detection limits on the vertical intensity of cosmogenically produced lightly ionizing particles (LIPs) with charge below $e/(3\times10^5)$ and the strongest limits for charge $\leq e/160$, achieving a minimum intensity of $1.36\times10^{-7}\,\text{cm}^{-2}\text{s}^{-1}\text{sr}^{-1}$ at $e/160$. These results span LIP masses from 5 MeV/$c^2$ to 100 TeV/$c^2$ and $\beta\gamma$ values from 0.1 to $10^6$, excluding non-relativistic LIPs with $\beta\gamma$ as low as 0.1 for the first time.
arXivarXiv · · November 18, 2020
0
18
Photoelectric absorption cross section of silicon near the band gap from room temperature to sub-Kelvin temperature
C. StanfordM.J. WilsonB. CabreraM. DiamondN.A. KurinskyR.A. MoffattF. PonceB. von KrosigkB.A. Young
This paper resolves order-of-magnitude discrepancies in prior extrapolations of the photoelectric absorption cross section of silicon near the band gap by performing a direct, low-temperature measurement using a novel technique. The measurement spans from room temperature to sub-Kelvin temperatures, providing accurate data crucial for cryogenic silicon detectors used in dark matter searches, particularly for low-mass dark matter candidates.
arXivarXiv · · October 29, 2020
0
Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
I. AlkhatibD. W. P. Amaral…B. Cabrera
Using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of $\sigma_E=3.86 \pm 0.04$ (stat.)$^{+0.19}_{-0.00}$ (syst.) eV, this work reports the most stringent spin-independent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from 93 to 140 MeV/c$^2$, based on a raw exposure of 9.9 g$\cdot$d acquired above ground.
arXivarXiv · · July 21, 2020
0
203
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS CollaborationD.W. Amaral…B. Cabrera
Using a 0.93 g SuperCDMS Si detector with a 3 eV phonon energy resolution and a charge resolution of 3% of a single electron-hole pair at 100 V bias, this paper reports constraints on light dark matter from a blind analysis of 1.2 gram-days of exposure acquired above ground. Incorporating charge carrier trapping and impact ionization into signal models, the dark matter-electron cross section $\bar{\sigma}_{e}$ is constrained for masses 0.5--$10^4$ MeV$/c^2$, with a minimum 90% confidence-level upper limit of $8.7\times10^{-34}$ cm$^2$. For dark photon kinetic mixing parameter $\varepsilon$ and axioelectric coupling $g_{ae}$, limits are set for masses 1.2--50 eV$/c^2$, reaching $3.3\times10^{-14}$ and $1.0\times10^{-9}$, respectively.
arXivarXiv · · May 28, 2020
0
277
Modeling of Impact Ionization and Charge Trapping in SuperCDMS HVeV Detectors
F. PonceW. PageP.L. BrinkB. CabreraM. CherryC. FinkN. KurinskyR. PartridgeM. PyleB. SadouletB. SerfassC. Stanford  +3
An experiment and model isolating charge trapping and impact ionization in SuperCDMS HVeV detectors is presented. The work describes a procedure to separate bulk and surface charge leakage noise, enabling precise measurement of trapping and ionization probabilities. These parameters will be incorporated into future dark matter searches, improving detector response modeling.
arXivarXiv · · December 24, 2019
0
Constraints on dark photons and axion-like particles from SuperCDMS Soudan
SuperCDMS CollaborationT. Aralis…B. Cabrera
Using electron recoil data from cryogenic germanium detectors in the SuperCDMS Soudan experiment, new exclusion limits are set on two dark-matter candidates: the kinetic mixing parameter of dark photons and the axioelectric coupling of axion-like particles, assuming each constitutes all galactic dark matter. The constraints cover masses from 40 eV/$c^2$ to 500 eV/$c^2$, reaching below $10^{-15}$ for dark-photon mixing near 100 eV/$c^2$ and below $10^{-12}$ for axion-like coupling at a few hundred eV/$c^2$, thereby excluding previously untested parameter space below ~1 keV/$c^2$.
arXivarXiv · · November 27, 2019
0
Measuring the Impact Ionization and Charge Trapping Probabilities in SuperCDMS HVeV Phonon Sensing Detectors
F. PonceW. PageP.L. BrinkB. CabreraM. CherryC. FinkN. KurinskyR. PartridgeM. PyleB. SadouletB. SerfassC. Stanford  +3
Using a 0.93 g SuperCDMS silicon HVeV detector operated at 30 mK and illuminated by 1.91 eV photons, the probabilities for a charge carrier to undergo charge trapping (0.713 ± 0.093%) or cause impact ionization (1.576 ± 0.110%) were measured and found to be nearly independent of bias polarity and charge-carrier type (electron or hole) for substrate biases of ±140 V.
arXivarXiv · · October 4, 2019
0
High-field Spatial Imaging of Charge Transport in Silicon at Low Temperature
C. StanfordR.A. MoffattN.A. KurinskyP.L. BrinkB. CabreraM. CherryF. InsullaM. KelseyF. PonceK. SundqvistS. YellinB.A. Young
We present direct imaging measurements of charge transport in a 1 cm × 1 cm × 4 mm-thick high-purity silicon crystal (∼15 kΩ·cm) at 5 K and 500 mK. By applying electric fields along the [111] axis up to ten times stronger than a previous study, we measure electron and hole lateral diffusion and verify our Monte Carlo simulation. The field range now covers that used by recent silicon dark-matter detectors. We also observe surface charge trapping that reduces expected charge collection.
arXivarXiv · · October 4, 2019
0
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
SuperCDMS CollaborationR. Agnese…B. Cabrera
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) presents a profile-likelihood analysis of its final dataset, using a different detector than in previous runs. With an energy threshold of 70 eV and improved noise discrimination and background modeling, the experiment reports significantly enhanced sensitivity to dark matter particles with masses between 2.5 and 10 GeV/c$^2$. It sets an upper limit on the spin-independent dark matter-nucleon scattering cross section in germanium of $5.4 \times 10^{-42} \ \text{cm}^2$ at 5 GeV/c$^2$, a factor of approximately 2.5 improvement over the previous CDMSlite result.
arXivarXiv · · August 28, 2018
0
Spatial Imaging of Charge Transport in Silicon at Low Temperature
R. A. MoffattN. A. KurinskyC. StanfordJ. AllenP. L. BrinkB. CabreraM. CherryF. InusllaF. PonceK. SundqvistS. YellinJ. J. Yen  +1
This paper reports direct imaging of charge transport across a high-purity silicon crystal at 0.5–5 K. By tracking electron motion under an electric field along the ⟨111⟩ axis, the authors extract the intervalley scattering rate and propose a phenomenological model that explains its constant low-voltage behaviour at cryogenic temperatures. They also image hole mass anisotropy, finding it strongly depends on temperature and field, attributed to valence-band warping near the spin-orbit splitting energy.
arXivarXiv · · July 20, 2018
0
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
SuperCDMS CollaborationR. Agnese…B. Cabrera
Using a 0.93 gram SuperCDMS HVeV detector with a charge resolution of 0.1 electron-hole pairs, we set the first limits on inelastic electron-scattering dark matter and dark photon absorption from a single-charge-sensitive device. These constraints improve the sensitivity to dark matter particles down to 1 MeV/c², and achieve competitive dark photon limits with only 0.49 gram days of exposure, demonstrating the power of phonon-mediated detectors sensitive to single electronic excitations.
arXivarXiv · · April 27, 2018
0
462
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
R. AgneseA.J. Anderson…B. Cabrera
This paper calibrates the absolute nuclear-recoil energy scale for CDMS II silicon dark-matter detectors using neutrons from a $^{252}$Cf source, exploiting a silicon neutron-scattering resonance near 20 keV recoil (182 keV neutron) energy. The phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$\% lower than for electron recoils of the same energy. Ionization collection efficiency at $\sim$4 V/cm is consistent with 100\% for nuclear recoils below 20 keV, decreasing to $\sim$75\% at 100 keV. The impact on previously published CDMS II silicon results is small.
arXivarXiv · · March 7, 2018
0
32
Thermal detection of single e-h pairs in a biased silicon crystal detector
R.K. RomaniP.L. BrinkB. CabreraM. CherryT. HowarthN. KurinskyR.A. MoffattR. PartridgeF. PonceM. PyleA. TomadaS. Yellin  +2
This paper reports the detection of individual electron-hole (e⁻h⁺) pairs in a 0.93 g silicon crystal operated at ~35 mK. The detector uses a bias grid and quasiparticle-trap-assisted electro-thermal-feedback transition edge sensor (QET) arrays to measure the energy of drifting charges. With a phonon sensor noise of σ ≈ 0.09 e⁻h⁺ pair, the system resolves single charge pairs, which appear nearly identical for both holes and electrons transported across the crystal.
arXivarXiv · · October 25, 2017
0
Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan
SuperCDMS CollaborationR. Agnese…B. Cabrera
The SuperCDMS experiment at Soudan reports a blind search for WIMPs using 1690 kg·days of germanium data. One candidate event was observed, consistent with expected backgrounds. Combined with previous Ge results, this sets an upper limit on the spin-independent WIMP–nucleon cross section of $1.4 \times 10^{-44}$ cm$^2$ at 46 GeV/$c^2$, which is the strongest limit for WIMP–germanium-nucleus interactions for masses above 12 GeV/$c^2$.
arXivarXiv · · August 29, 2017
0
Low-Mass Dark Matter Search with CDMSlite
SuperCDMS CollaborationR. Agnese…B. Cabrera
The CDMSlite mode of the SuperCDMS experiment applies a high detector-bias voltage to amplify phonon signals from drifting charges, achieving an energy threshold as low as 56 eV$_{\text{ee}}$. Detailed noise studies, electric-field geometry corrections, and a fiducial parameter eliminate poorly measured events, yielding an energy resolution from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. Accounting for astrophysical uncertainties in the WIMP velocity distribution, new spin-dependent limits exclude parameter space for WIMP masses $\lesssim$3 GeV/$c^2$.
arXivarXiv · · July 6, 2017
0
379
Projected Sensitivity of the SuperCDMS SNOLAB experiment
R. AgneseA. J. Anderson…B. Cabrera
SuperCDMS SNOLAB, a next-generation direct dark matter experiment, will use cryogenic HV and iZIP detectors with germanium and silicon targets to achieve a projected sensitivity to nuclear recoil cross sections of ~$1 \times 10^{-43}$ cm$^2$ for a dark matter mass of 1 GeV/c$^2$. The HV detectors, whose phonon sensitivity can detect sub-GeV nuclear recoils, can reach over three orders of magnitude beyond current results at that mass even if $^{3}$H and $^{32}$Si backgrounds are ten times higher than expected. The iZIP detectors provide better sensitivity for masses above 5 GeV/c$^2$ and are less affected by detector response variations and backgrounds. This detector mix, along with operational flexibility, maximizes low-mass reach and background understanding, while future upgrades could extend sensitivity to the neutrino floor.
arXivarXiv · · September 30, 2016
0
WIMP-Search Results from the Second CDMSlite Run
SuperCDMS CollaborationR. Agnese…B. Cabrera
The CDMSlite experiment uses cryogenic germanium detectors with high bias voltage to amplify phonon signals for low-mass WIMP searches. The second run achieved a 56 eV electron-recoil energy threshold with 70 kg·days exposure. A fiducialization cut reduced backgrounds below previous levels, enabling the exclusion of new WIMP-nucleon spin-independent cross-section parameter space for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
arXivarXiv · · September 8, 2015
0
Imaging the Oblique Propagation of Electrons in Germanium Crystals at Low Temperature and Low Electric Field
R. A. MoffattB. CabreraB. M. CorcoranJ. M. KreikebaumP. RedlB. ShankJ. J. YenB. A. YoungP. L. BrinkM. CherryA. TomadaA. Phipps  +2
This paper reports the first two-dimensional imaging of electron propagation in germanium at sub-Kelvin temperatures and low electric fields (0.5–6 V/cm). Electrons in four anisotropic conduction-band valleys travel obliquely to an applied [0,0,1] field, unlike the more isotropic holes. Using a focused laser to excite carriers and measuring the charge pattern on the opposite crystal face, the authors reconstruct trajectories and compare them with Monte Carlo simulations from the CDMS experiment, capturing valley transitions and oblique drift.
arXivarXiv · · April 30, 2015
0
14
Frequent collaborators
B. Sadoulet (48)
M. Pyle (46)
E. Figueroa-Feliciano (42)
S. Yellin (41)
P. Cushman (40)
N. Mirabolfathi (40)
B. Serfass (40)
L. Hsu (39)
T. Saab (38)
R. Bunker (37)
J. Cooley (37)
R. Mahapatra (37)