Resonant Frequency Control For the PIP-II Injector Test RFQ: Control Framework and Initial Results
A.L. Edelen
S.G. BiedronSMS.V. MiltonD.BowringB.E. ChaseJ.P. EdelenD. NicklausJ. Steimel
A.L. Edelen

S.G. Biedron
SMS.V. Milton
D.Bowring
B.E. Chase
J.P. Edelen
D. Nicklaus
J. Steimel
+8
This paper presents a control framework for the resonant frequency of the PIP-II Injector Test RFQ at Fermilab, which accelerates an H- beam under pulsed and continuous wave operation. The RF amplifiers limit acceptable detuning to 3 kHz, managed entirely by thermal regulation. The framework uses model predictive control (MPC) to achieve fine detuning control, minimal manual intervention, and fast trip recovery. Written in modular Python, it handles high-level decisions and control calculations. Initial results under both operation modes are reported.

arXiv ·
· December 16, 2016