MCP
BF

B. Flatt

8 papers in the library

Papers

8
An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
M. AkerK. Altenmüller…B. Flatt
The KATRIN experiment's first four-week science run in spring 2019 measured the tritium beta-decay electron spectrum near the 18.57 keV endpoint using a MAC-E filter, yielding an effective neutrino mass square of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. This result sets an upper limit of 1.1 eV (90% confidence) on the absolute neutrino mass, matching the experimental sensitivity. The limit improves previous kinematic bounds by nearly a factor of two and offers a model-independent input for cosmology.
arXivarXiv · · September 13, 2019
0
Characterization of large area APDs for the EXO-200 detector
R. NeilsonF. LePort…B. Flatt
The paper characterizes large area avalanche photodiodes (LAAPDs) for the EXO-200 liquid xenon detector, which uses 468 LAAPDs to detect scintillation light in an ultra-low-background environment. It reports initial measurements of dark noise, gain, and response to xenon scintillation light across temperatures from room temperature down to 169 K, the operating temperature of liquid xenon. Additionally, over 800 LAAPDs were individually characterized for selective installation in the detector.
arXivarXiv · · June 13, 2009
0
99
Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
D. S. LeonardP. Grinberg…B. Flatt
This paper reports a systematic study of trace radioactive impurities in candidate construction materials for the EXO-200 detector, which searches for neutrinoless double beta decay of $^{136}\text{Xe}$. Using gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry, the authors measured impurity concentrations in raw materials and finished parts, providing essential data for material selection to minimize background radioactivity.
arXivarXiv · · September 28, 2007
0
228
A microfabricated sensor for thin dielectric layers
P. FierlingerR. DeVoeB. FlattG. GrattaM. GreenS. KolkowitzF. LeportM. Montero DiezR. NeilsonK. O'SullivanA. PocarJ. Wodin
This paper presents a microfabricated sensor that measures thin dielectric layers via an interleaved aluminum-finger capacitor exposed to the sample. The device can detect single atomic layers and, combined with a fast feedback capacitance readout, dynamically maintain coatings of few layers. The design, readout, and calibration of several optimized versions are discussed, with detailed focus on growing and stabilizing atomically thin solid xenon from a liquid xenon bath under cryogenic conditions.
arXivarXiv · · June 4, 2007
0
8
A linear RFQ ion trap for the Enriched Xenon Observatory
B. FlattM. GreenJ. WodinR. DeVoeP. FierlingerG. GrattaF. LePortM. Montero DiezR. NeilsonK. OSullivanA. PocarS. Waldman  +30
The paper presents a linear radio-frequency (RFQ) ion trap designed for the Enriched Xenon Observatory (EXO). EXO aims to detect neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba. A key background suppression method is the identification of the daughter $^{136}$Ba nucleus. The described RFQ trap can accept, cool, and confine individual Ba ions extracted from candidate decay events, enabling subsequent laser spectroscopy identification with high signal-to-noise ratio.
arXivarXiv · · April 12, 2007
0
32
Observation of single collisionally cooled trapped ions in a buffer gas
M. GreenJ. WodinR. DeVoeP. FierlingerB. FlattG. GrattaF. LePortM. Montero DiezR. NeilsonK. OSullivanA. PocarS. Waldman  +28
This paper demonstrates the trapping and observation of single Ba+ ions in a buffer gas by resonance fluorescence. Individual ions are stored for ~5 minutes in He (8e-5–4e-3 torr) and ~1 minute in Ar. The work experimentally studies the dynamics of single trapped ions undergoing collisional cooling, contrasting the stabilizing effect of light gases (He, Ar) with the destabilizing effect of heavier gases (Xe). A simple model accounts for the observed behavior.
arXivarXiv · · February 14, 2007
0
73
A liquid xenon ionization chamber in an all-fluoropolymer vessel
EXO CollaborationF. LePortA. PocarL. BartoszekR. DeVoeP. FierlingerB. FlattG. GrattaM. GreenT. KoffasM. Montero DiezR. Neilson  +33
This paper presents a new technique for constructing liquid xenon ionization detector vessels entirely from ultra-clean fluoropolymer, offering advantages in low radioactivity contamination. The authors describe the construction methods and report the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
arXivarXiv · · November 20, 2006
0
13
Final Results from phase II of the Mainz Neutrino Mass Search in Tritium ββ Decay
Ch. KrausB. BornscheinL. BornscheinJ. BonnB. FlattA. KovalikB. OstrickE.W. OttenJ.P. SchallTh. ThümmlerCh. Weinheimer
The Mainz experiment measured the electron antineutrino mass via tritium β-decay spectroscopy with an improved signal-to-background ratio. After eliminating systematic errors through side experiments, the final squared-mass result is $m^2(\nu_e) = (-0.6 \pm 2.2_{\mathrm{stat}} \pm 2.1_{\mathrm{syst}})$ eV$^2$/c$^4$, from which an upper limit $m(\nu_e) \leq 2.3$ eV/c$^2$ at 95% confidence level is derived.
arXivarXiv · · December 20, 2004
0
Frequent collaborators
R. Neilson (6)
A. Pocar (6)
P. Fierlinger (6)
G. Gratta (6)
M. Green (6)
J. Wodin (6)
F. LePort (5)
A. Odian (5)
M. Breidenbach (5)
R. Conley (5)
W. Fairbank Jr. (5)
J. Farine (5)