MCP
BF

B. Freund

7 papers in the library

Papers

7
Particle Identification Using Boosted Decision Trees in the Semi-Digital Hadronic Calorimeter Prototype
D. BoumedieneA. Pingault…B. Freund
The CALICE SDHCAL prototype, a high-granularity calorimeter for future leptonic colliders, was exposed to hadron, electron, and muon beams at CERN. This work introduces a particle identification method based on Boosted Decision Trees (BDT) for the SDHCAL. The method's performance is evaluated using both Geant4 simulations and data collected in 2015 across 10–80 GeV. The BDT method is applied to reject electron and muon contamination in SPS hadron beams.
arXivarXiv · · April 6, 2020
0
7
Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models
CALICE CollaborationM. Chefdeville…B. Freund
This paper reports on the response of the highly granular Fe-DHCAL, a digital hadron calorimeter with steel absorbers and RPC active layers, to positrons, muons, and pions (2–60 GeV/c). Using testbeam data from Fermilab (2010–11), the study measures calorimeter response, energy resolution, and shower shapes. These measurements are compared with Geant4 simulations employing different physics lists, providing validation of the Monte Carlo models for this $1\times1$ cm$^2$ granularity, 38-layer, 350,208-channel digital calorimeter.
arXivarXiv · · January 25, 2019
0
28
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
M. DragicevicM. Friedl…B. Freund
The CMS experiment's Phase I Upgrade pixel detector, featuring reduced material budget and a new front-end readout chip, was tested with a beam to verify its design. The key result is a measured tracking efficiency of $99.95\pm0.05\%$ under optimal conditions, with intrinsic spatial resolutions of $4.80\pm0.25\,\mu \mathrm{m}$ and $7.99\pm0.21\,\mu \mathrm{m}$ along the $100\,\mu \mathrm{m}$ and $150\,\mu \mathrm{m}$ pixel pitches, respectively. These measurements agree well with a detailed Monte Carlo simulation.
arXivarXiv · · June 1, 2017
0
19
DHCAL with Minimal Absorber: Measurements with Positrons
CALICE CollaborationB. FreundC. NeubüserJ.RepondJ. SchlerethL. XiaA. DottiC. GrefeV. IvantchenkoJ. Berenguer AntequeraE. Calvo AlamilloM.-C. Fouz  +90
The CALICE DHCAL prototype was tested with absorber plates removed, exposing its active layers directly to low-energy positron beams. Each layer had a thickness of about 0.29 radiation lengths. Measurements were taken with 1 to 10 GeV positrons at Fermilab. The results are compared to simulations using GEANT4 and a custom program that models the detailed response of the active elements.
arXivarXiv · · March 4, 2016
0
17
Measurements of the Rate Capability of Various Resistive Plate Chambers
M. AffatigatoU. AkgunB. BilkiF. CorriveauB. FreundN. JohnsonC. NeubueserY. OnelJ. RepondL. Xia
This paper reports measurements of the rate capability of three glass Resistive Plate Chamber (RPC) designs, each with a different total resistance of the resistive plates. Using 120 GeV protons at varying beam intensities, the study directly links the high resistivity of the plates to the significant efficiency loss observed under high particle fluxes, characterizing how the total resistance governs the rate limitation.
arXivarXiv · · July 24, 2015
0
Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
W. AdamT. Bergauer…B. Freund
This paper measures effective trapping rates in 200-μm-thick n-type silicon sensors irradiated with protons to HL-LHC fluences up to $3 \cdot 10^{15}$ neq/cm². Using 672 nm laser pulses, charge collection efficiencies for electrons and holes are extracted separately and compared to simulations. The obtained effective trapping rates for both carriers are about 50% smaller than standard low-fluence extrapolations, indicating better-than-expected tracker performance.
arXivarXiv · · May 7, 2015
0
Tests of a Novel Design of Resistive Plate Chambers
B. BilkiF. CorriveauB. FreundC. NeubüserY. OnelJ. RepondJ. SchlerethL. Xia
This paper proposes a novel Resistive Plate Chamber (RPC) design that uses only a single resistive plate instead of the traditional two. Two large prototype chambers were built and tested with cosmic rays and particle beams. The tests confirm the design's viability, showing an improved single-particle response compared to the conventional design, and demonstrate suitability for calorimetric applications.
arXivarXiv · · January 22, 2015
0
Frequent collaborators
B. Bilki (5)
Y. Onel (5)
F. Corriveau (5)
L. Xia (4)
E. Garutti (4)
M. Matysek (4)
D. Northacker (3)
K. Kawagoe (3)
T. Suehara (3)
T. Yoshioka (3)
C. Combaret (3)
N. Lumb (3)