MCP
BS

Ben Sun

10 papers in the library

Papers

10
Single-photon time-stretch computational ghost spectroscopy
Zhibin ZhaoKun HuangBen SunBeibei DongWen ZhangJianan FangHeping Zeng
Single-photon time-stretch computational ghost spectroscopy integrates dispersive wavelength-to-time mapping with programmable temporal encoding and correlation-based reconstruction, enabling near-infrared spectral reconstruction across 1530–1590 nm with 450 channels using a low-bandwidth detector and without direct high-speed waveform acquisition. Compressive sensing allows accurate sub-Nyquist recovery at 210 kHz. In the single-photon regime, the method suppresses detector timing jitter, yielding high-fidelity spectra at fluxes as low as 0.01 photons per pulse.
arXivarXiv · · June 21, 2026
1
2
High-speed mid-infrared single-photon upconversion spectrometer
Tingting ZhengKun HuangBen SunJianan FangYongyuan ChuHairun GuoE WuMing YanHeping Zeng
This paper presents an ultra-sensitive broadband mid-infrared spectrometer that combines a supercontinuum source (1.5–4.2 $\mu$m) with nonlinear frequency upconversion using coincident pulsed pumping and spectro-temporal optimization. The system achieves single-photon sensitivity at 0.2 photons/nm/pulse by leveraging silicon detectors, and enables high-speed spectral acquisition beyond 200 kHz, roughly ten times faster than state-of-the-art FTIR spectrometers at comparable resolution.
arXivarXiv · · May 29, 2026
0
52
Highly-sensitive mid-infrared upconversion detection based on external-cavity pump enhancement
Xiaohan LiuKun HuangWen ZhangBen SunJianan FangYan LiangHeping Zeng
By placing the 1064 nm pump inside an optical cavity, the authors enhance the pump power by a factor of 36, achieving a mid-infrared upconversion conversion efficiency of 22% at 55 W intra-cavity power. This yields a noise equivalent power of 0.3 fW/Hz^{1/2}, a ten-fold improvement over prior results, enabling high-sensitivity, room-temperature passive MIR detection with single-frequency pumping for high-fidelity spectral mapping.
arXivarXiv · · May 28, 2026
0
21
Single-photon time-stretch infrared spectroscopy
Ben SunKun HuangHuijie MaJianan FangTingting ZhengYongyuan ChuHairun GuoYan LiangE WuMing YanHeping Zeng
The authors present a single-photon time-stretch mid-infrared spectrometer that achieves broadband coverage (2.4–4.2 μm), sub-wavenumber resolution (~0.5 cm⁻¹), and single-photon sensitivity (0.14 photons/nm/pulse) by combining high-fidelity spectral upconversion, nanophotonic supercontinuum illumination, and time-correlated coincidence counting. The upconverted near-infrared signal is dispersed in single-mode fiber and detected with a low-jitter photon counter, enabling room-temperature, single-pixel operation with high throughput. This approach overcomes noise limitations of conventional infrared sensors, making it suitable for photon-scarce applications in material and life sciences.
arXivarXiv · · May 28, 2026
0
23
High-speed mid-infrared imaging via nonlinear multiplexed detection
Ruiyang QinKun HuangMin PengJianan FangBen SunZhengru GuoHeping Zeng
We implement high-speed mid-infrared (MIR) videography by time-multiplexed nonlinear structured pumping. A dynamic MIR scene is optically gated with a sequence of spatially periodic pump patterns in a nonlinear crystal, enabling rapid temporal encryption and upconversion. The upconverted frames are superimposed on a silicon camera in one exposure, forming a multiplexed spatial-frequency snapshot. Sub-exposure images are computationally deciphered via band-pass filtering and Fourier transforms, achieving 10,000 frames per second without sacrificing megapixel spatial format.
arXivarXiv · · May 27, 2026
0
12
Mid-Infrared Single-Photon Compressive Spectroscopy
Ben SunKun HuangHuijie MaJianan FangTingting ZhengRuiyang QinYongyuan ChuHairun GuoYan LiangHeping Zeng
This paper presents a mid-infrared single-pixel spectrometer that achieves high sensitivity by combining spectral upconversion with compressive measurement. A supercontinuum from 3.1 to 3.9 μm is converted to the near-infrared via chirped-pulse pumping, then spatially dispersed onto a digital micromirror device (DMD) and detected by a single silicon detector. The spectral information is recovered from the correlation between encoded patterns and measurements. The system achieves 0.5 cm⁻¹ resolution with only 0.01 photons/nm/pulse illumination, and compressive sensing reduces acquisition time by 95%.
arXivarXiv · · May 27, 2026
0
25
High-resolution mid-infrared single-photon upconversion ranging
Shuhong JiangKun HuangTingting YuJianan FangBen SunYan LiangQiang HaoE WuMing YanHeping Zeng
This paper presents a mid-infrared (MIR) upconversion LiDAR that achieves single-photon sensitivity and a ranging precision of 4 μm at a detected flux of 8×10$^{-5}$ photons per pulse. The key technique is nonlinear asynchronous optical sampling: a probe pulse and a pump pulse train with a slightly different repetition rate generate a cross-correlation upconversion signal that is temporally stretched by a factor of 2×10$^4$, enabling picosecond timing resolution recorded by a low-bandwidth silicon detector. This effectively decouples resolution from detector jitter, extending single-photon ranging to the MIR band.
arXivarXiv · · May 26, 2026
0
28
Infrared Single-Pixel Hyperspectral Imaging via Spatial-Temporal Multiplexing
Ben SunKun HuangZhibin ZhaoBeibei DongJianan FangHeping Zeng
This paper presents a single-pixel near-infrared hyperspectral imaging system that combines high-fidelity spectrum-to-time mapping via a single-mode fiber with high-precision spatial encoding from a programmable spatial light modulator. A single InGaAs detector captures all signals, enabling reconstruction of 64×64 hyperspectral datacubes across 50 spectral bands in the 1550–1600 nm range. The system achieves real-time dynamic monitoring at 12 Hz under sub-Nyquist sampling, offering single-pixel simplicity, high optical throughput, and efficient data acquisition.
arXivarXiv · · May 25, 2026
0
11
Mid-infrared single-photon computational temporal ghost imaging
Wen ZhangKun HuangXu WangBen SunJianan FangYijing LiHeping Zeng
We propose a computational temporal ghost imaging system for mid-infrared (MIR) transient waveforms. The system uses nonlinear optical transduction to enable programmable structured illumination with a near-infrared modulator and upconversion detection with a near-infrared detector. The correlation between the recorded integral upconversion intensity and the encoding patterns reconstructs MIR temporal profiles with 80 ps resolution, surpassing detector bandwidth limits. It achieves record-high sensitivity by recovering single-photon MIR waveforms with <0.1 photon/bit incident flux, and compressive sensing reduces data acquisition time by over 90% at sub-Nyquist rates.
arXivarXiv · · May 25, 2026
0
20
Wide-field mid-infrared cavity-enhanced upconversion imaging
Yue SongJianan FangWen ZhangYijing LiBen SunZhiwei JiaKun HuangHeping Zeng
This paper presents a continuous-wave-pumped mid-infrared (MIR) upconversion imaging system that uses an external optical cavity, constructed by using one crystal facet as a mirror, to achieve a 43-fold pump power enhancement at 1064 nm. Combined with a chirped-poled crystal, the system enables wide-field spectral imaging with an acceptance angle up to 28.5° over 2.5–5 μm. A thermal locking approach stabilizes the cavity at high power without active feedback. A proof-of-principle demonstration shows real-time CO₂ gas injection dynamics.
arXivarXiv · · May 23, 2026
0
6
Frequent collaborators
Kun Huang (10)
Jianan Fang (10)
Heping Zeng (10)
Wen Zhang (4)
Yan Liang (4)
Tingting Zheng (3)
Yongyuan Chu (3)
Hairun Guo (3)
E Wu (3)
Ming Yan (3)
Zhibin Zhao (2)
Beibei Dong (2)