Performance Deterioration of Deep Learning Models after Clinical Deployment: A Case Study with Auto-segmentation for Definitive Prostate Cancer Radiotherapy
BWBiling WangMDMichael DohopolskiTBTi BaiJWJunjie Wu
Raquibul Hannan
Neil DesaiAGAurelie GarantDYDaniel YangDan Nguyen
Mu-Han Lin
Robert Timmerman
Xinlei Wang +1 BWBiling Wang
MDMichael Dohopolski
TBTi Bai
JWJunjie Wu

Raquibul Hannan

Neil Desai
AGAurelie Garant
DYDaniel Yang
Dan Nguyen

Mu-Han Lin

Robert Timmerman

Xinlei Wang
+13
This case study evaluates the temporal performance of a UNet-based deep learning model for auto-segmentation in prostate cancer radiotherapy after clinical deployment. Trained on data from 2006–2011 and tested on 2012–2022 data, the model achieved peak Dice similarity coefficients for prostate, rectum, and bladder during 2012–2014, but performance declined notably for prostate and rectum after 2015. Factors including physician contouring styles, hydrogel spacer use, CT slice thickness, MRI-guided contouring, and intravenous contrast affected contour quality, underscoring the need for continuous model monitoring and updating.

arXiv ·
· October 11, 2022