MCP
CA

C. Alduino

31 papers in the library

Papers

30
End-to-End Data Analysis Methods for the CUORE Experiment
D. Q. AdamsC. AlduinoK. AlfonsoA. ArmatolF. T. AvignoneO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. Branca  +108
The CUORE experiment, a ton-scale array of cryogenic calorimeters operating at ~10 mK, achieved the most stringent limit on the neutrinoless double-beta ($0\nu\beta\beta$) decay half-life of $^{130}$Te. This work describes the end-to-end analysis tools and methods developed for CUORE, treating each calorimeter independently for optimization, data acquisition, and analysis. The core contribution is the detailed evaluation of the energy-dependent detector response and signal efficiency used in the latest $0\nu\beta\beta$ decay search, enabling high-quality datasets for multiple rare-event searches.
arXivarXiv · · October 29, 2025
0
3
Reconstruction of cosmic-ray muon events with CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoA. ArmatolF. T. AvignoneO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. Biassoni  +109
By using the segmentation of the CUORE cryogenic detector array, a multi-objective optimization algorithm achieves in-situ 3D reconstruction of through-going cosmic-ray muons without time-of-flight estimation. The integral muon flux measured underground at the Laboratori Nazionali del Gran Sasso agrees with other experiments. This work is the first demonstration of 3D particle tracking with per-event angular determination in a millikelvin detector, critical for validating muon-related background in next-generation neutrinoless double-beta decay experiments.
arXivarXiv · · September 5, 2025
0
0
Exploring the keV-scale physics potential of CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoA. ArmatolF. T. AvignoneO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. Biassoni  +111
This paper reports the keV-scale analysis of the CUORE experiment using over 2 tonne yr of data. By applying stricter selection to optimize thresholds at 10 keV and 3 keV, the analysis achieves average baseline resolutions of 2.54 ± 0.14 keV and 1.18 ± 0.02 keV FWHM, respectively. The overall background is reduced by about an order of magnitude, reaching 2.06 ± 0.05 counts/(keV kg days) at 10 keV and 16 ± 2 counts/(keV kg days) at 3 keV. Near-threshold reconstruction efficiencies are evaluated for the first time, yielding 50 ± 2 % at 10 keV and 26 ± 4 % at 3 keV, demonstrating the scalability of tonne-scale cryogenic calorimeters for low-energy physics.
arXivarXiv · · May 29, 2025
0
5
The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment
D. Q. AdamsC. AlduinoK. AlfonsoA. ArmatolF. T. AvignoneO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. Branca  +117
Using data from the CUORE experiment and the Copernicus Earth Observation program, this study reports the first detection of marine microseismic vibrations with mK-scale calorimeters. The analysis reveals seasonal Mediterranean Sea activity that impacts CUORE's energy thresholds, resolution, and sensitivity over four years, underscoring the need to address faint environmental noise in ultra-sensitive experiments. The paper also demonstrates a noise decorrelation algorithm using auxiliary sensors that reduces vibrational noise and improves detector performance.
arXivarXiv · · May 13, 2025
0
3
Half-life and precision shape measurement of 2νββ decay of 130^{130}Te
D. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. BrancaC. Brofferio  +110
Using 1038 kg yr of CUORE data, the $2\nu\beta\beta$ half-life of $^{130}$Te is measured as $(9.32^{+0.05}_{-0.04}(\text{stat.})^{+0.07}_{-0.07}(\text{syst.}))\times10^{20}$ yr, doubling previous precision. The improved signal-to-background ratio enables the first application of the enhanced $2\nu\beta\beta$ formalism to $^{130}$Te, yielding an effective axial coupling credibility interval and higher-order nuclear matrix element ratios. The second-to-first ratio agrees with models, while the third-to-first deviates, providing nuclear model tests relevant to $0\nu\beta\beta$ searches.
arXivarXiv · · March 31, 2025
0
Search for fractionally charged particles with CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. Branca  +108
The Cryogenic Underground Observatory for Rare Events (CUORE), a 988-crystal TeO$_2$ array operating below 20 mK, is used to search for fractionally charged particles (FCPs) with charges between $e/24$ and $e/5$. Using the first tonne-year of exposure, no significant excess of FCP candidate tracks is found, leading to the most stringent limits on the underground FCP flux in this charge range at 90% confidence level. This work demonstrates the sensitivity of tonne-scale sub-Kelvin detectors to exotic particle signatures.
arXivarXiv · · June 18, 2024
0
15
Data-driven background model for the CUORE experiment
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. Branca  +106
We present a data-driven background model for the CUORE experiment, built from a Bayesian fit to energy spectra across a broad range using 1038.4 kg yr of exposure. The model exploits detector granularity, exposure, and operational stability to resolve spatial and time-dependent backgrounds, achieving sensitivity to bulk activities as low as 10 nBq kg$^{-1}$ and surface activities as low as 0.1 nBq cm$^{-2}$. The extracted contamination levels are compared with prior radio-assay data, informing future background mitigation strategies for CUORE and the CUPID experiment.
arXivarXiv · · May 28, 2024
0
36
Constraints on Lepton Number Violation with the 2 tonne⋅\cdotyr CUORE Dataset
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. AvignoneO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. Branca  +106
The CUORE experiment searches for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te using a tonne-scale cryogenic calorimeter at milli-kelvin temperatures. With over 2 tonne$\cdot$year TeO$_2$ exposure, no evidence of $0\nu\beta\beta$ is found, yielding a lower limit on the half-life of $T_{1/2} > 3.5 \times 10^{25}$ years (90% C.I.). This result and the stable operation of nearly 1000 detectors demonstrate infrastructure for future searches.
arXivarXiv · · April 5, 2024
0
11
New direct limit on neutrinoless double beta decay half-life of 128^{128}Te with CUORE
D. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. BrancaC. Brofferio  +108
The CUORE experiment, a ton-scale cryogenic detector searching for neutrinoless double beta ($0\nu\beta\beta$) decay in $^{130}$Te, reports its first results for $^{128}$Te. No evidence of decay is found. A Bayesian analysis sets a lower limit on the half-life of $T_{1/2} > 3.6 \times 10^{24}$ yr (90% CI), the most stringent direct limit, improving over previous direct searches by a factor of 30 and surpassing geochemical constraints for the first time.
arXivarXiv · · May 6, 2022
0
0
Search for Neutrinoless β+ECβ^+EC Decay of 120^{120}Te with CUORE
D. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. BrancaC. Brofferio  +109
This paper reports a search for neutrinoless positron-emitting electron capture ($0\nu\beta^+EC$) decay in $^{120}$Te using the CUORE detector. With a total TeO$_2$ exposure of 355.7 kg·yr (0.2405 kg·yr of $^{120}$Te), the analysis exploited the detector's modularity by including events with different topology and performing a simultaneous fit of five selected signal signatures. No evidence of signal was found, yielding a 90% credibility interval Bayesian lower limit of $2.9 \times 10^{22}$ yr on the $^{120}$Te half-life, improving the previous limit by an order of magnitude.
arXivarXiv · · March 16, 2022
0
Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE
D. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. BrancaC. Brofferio  +102
The CUORE experiment searches for neutrinoless double beta ($0\nu\beta\beta$) decay of $^{130}$Te using cryogenic calorimeters operating at 10 mK. No evidence for the decay is found, yielding a lower bound on the half-life of $T_{1/2}^{0\nu} > 2.2 \times 10^{25}$ years at 90% credibility. The results constrain the Majorana nature of neutrinos, and the advances in maintaining large mass at ultra-low temperature with low radioactivity are relevant to other fields.
arXivarXiv · · April 14, 2021
0
306
Search for Double-Beta Decay of 130Te\mathrm{^{130}Te} to the 0+0^+ States of 130Xe\mathrm{^{130}Xe} with CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. Biassoni A. BrancaC. BrofferioC. Bucci  +96
The CUORE experiment searches for neutrino-less double beta decay ($0\nu\beta\beta$) of $^{130}\mathrm{Te}$ to the first $0^+_2$ excited state of $^{130}\mathrm{Xe}$. Using 372.5 kg$\times$yr TeO$_2$ exposure, no significant evidence for either $0\nu\beta\beta$ or Standard Model-allowed two-neutrino double beta decay ($2\nu\beta\beta$) to this state was found. Bayesian lower bounds at 90% C.I. set half-life limits of $ (T_{1/2})^{0\nu}_{0^+_2} > 5.9 \times 10^{24}$ yr and $ (T_{1/2})^{2\nu}_{0^+_2} > 1.3 \times 10^{24}$ yr, the most stringent limits on double beta decay of $^{130}\mathrm{Te}$ to excited states, improving previous results by a factor of $\sim5$.
arXivarXiv · · January 26, 2021
0
Measurement of the 2νββνββ Decay Half-life of 130^{130}Te with CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BiassoniA. BrancaC. Brofferio  +101
Using a 300.7 kg$\cdot$yr exposure from the CUORE detector, the two-neutrino double beta decay half-life of $^{130}$Te was measured via a Bayesian analysis that disentangled background sources from the signal. The result, $T_{1/2}^{2\nu} = 7.71^{+0.08}_{-0.06}(\mathrm{stat.})^{+0.12}_{-0.15}(\mathrm{syst.})\times10^{20}$ yr, agrees with prior measurements but achieves the most precise determination to date.
arXivarXiv · · December 21, 2020
0
New results from the CUORE experiment
A. GiacheroD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BiassoniA. BrancaC. Brofferio  +101
CUORE, a one-ton-scale cryogenic detector using 988 TeO₂ crystals, finds no evidence for neutrinoless double-beta decay of ¹³⁰Te. Based on 372.5 kg·yr of exposure, it sets a Bayesian 90% credibility lower limit of 3.2×10²⁵ yr on the half-life, with a median exclusion sensitivity of 1.7×10²⁵ yr. The paper also reviews detector performance, the background model, and the measured two-neutrino double-beta decay half-life.
arXivarXiv · · November 18, 2020
0
8
Improved Limit on Neutrinoless Double-Beta Decay in 130^{130}Te with CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BiassoniA. BrancaC. Brofferio  +99
The CUORE collaboration reports an improved search for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{130}$Te using a 372.5 kg$\cdot$yr exposure, a fourfold increase over previous data. No evidence for decay is found, yielding a $90\%$ CI Bayesian lower limit of $3.2\cdot10^{25}$ yr on the half-life. Assuming light Majorana neutrinos, this corresponds to an effective Majorana mass upper limit of 75–350 meV, depending on nuclear matrix elements.
arXivarXiv · · December 23, 2019
0
Results of CUORE
S. Dell'OroD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BiassoniA. BrancaC. Brofferio  +100
CUORE, the world's largest bolometric experiment using 988 TeO2 crystals (742 kg total mass), has been searching for the neutrinoless double beta decay of 130Te since 2017. Its initial science run set the most stringent limit on the neutrinoless double beta decay half-life of 130Te and achieved the most precise measurement of the two-neutrino double beta decay half-life. With more than double the initial exposure collected, this contribution reports updated results on these key measurements from the ongoing experiment.
arXivarXiv · · May 19, 2019
0
0
The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
C. AlduinoF. AlessandriaM. BalataD. BiareM. BiassoniC. BucciA. CaminataL. CanonicaL. CappelliG. CerutiA. ChiariniN. Chott  +44
The CUORE cryostat, a custom cryogen-free system designed for the world's largest bolometric experiment, achieves and maintains a base temperature of about 10 mK for a 742 kg TeO2 detector array searching for neutrinoless double beta decay of 130Te. The cryostat minimizes radioactive background and noise without cryogenic fluids. This paper overviews its sub-systems, commissioning phases, and the successful cooldown of CUORE.
arXivarXiv · · April 9, 2019
0
109
Double-beta decay of 130{}^{130}Te to the first 0+0^+ excited state of 130{}^{130}Xe with CUORE-0
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniT. I. BanksG. BariJ.W. BeemanF. BelliniA. BersaniM. Biassoni  +109
Using a 9.8 kg·yr exposure of $^{130}$Te collected with CUORE-0, a search for double-beta decay to the first $0^+$ excited state of $^{130}$Xe found no evidence for either neutrinoless or two-neutrino modes, yielding lower half-life bounds of $\tau^{0\nu}_{0^+}>7.9\cdot 10^{23}$ yr and $\tau^{2\nu}_{0^+}>2.4\cdot 10^{23}$ yr. Combining these with CUORICINO results gives the most stringent constraints: $\tau^{0\nu}_{0^+}>1.4\cdot 10^{24}$ yr and $\tau^{2\nu}_{0^+}>2.5\cdot 10^{23}$ yr.
arXivarXiv · · November 26, 2018
0
Update on the recent progress of the CUORE experiment
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoA. BersaniM. BiassoniA. Branca  +109
The CUORE experiment, a 741 kg array of 988 TeO₂ bolometers, searches for the neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te. Based on 86.3 kg·yr of TeO₂ exposure collected since 2017, it sets a $0\nu\beta\beta$ half-life limit $T^{0\nu}_{1/2} > 1.5\times10^{25}$ yr at 90% C.L. and measures the $2\nu\beta\beta$ half-life as $T_{1/2}^{2\nu} = [7.9\pm0.1\text{(stat.)}\pm0.2\text{(syst.)}]\times10^{20}$ yr, the most precise such measurement yet.
arXivarXiv · · August 30, 2018
0
5
The CUORE cryostat
A. D'AddabboM. BiassoniC. BucciA. CaminataC. AlduinoA. BersaniL. CanonicaL. CappelliG. CerutiN. ChottS. CopelloO. Cremonesi  +29
The CUORE cryostat is a key component of the bolometric experiment searching for neutrinoless double-beta decay in $^{130}$Te. It successfully cooled a roughly 1-ton detector mass to $\sim 7\, \text{mK}$, providing a uniform and stable base temperature. This achievement demonstrates a critical step in low-temperature detector technology, enabling future ton-scale bolometric searches for rare events. The paper describes the cryogenic infrastructure and its essential subsystems.
arXivarXiv · · May 16, 2018
0
Study of Rare Nuclear Processes with CUORE
CUORE CollaborationC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoA. BersaniM. BiassoniA. BrancaC. Brofferio  +107
The CUORE experiment, a tonne-scale TeO$_2$ bolometer array, has set the most stringent limit on neutrinoless double beta decay of $^{130}\text{Te}$, with a half-life $T_{1/2}^{0\nu} > 1.5 \times 10^{25}\,\text{yr}$, corresponding to an effective Majorana neutrino mass upper bound of $140-400\,\text{meV}$. Beyond this leading result, CUORE will also study other rare nuclear processes, including two-neutrino double beta decay, electron capture, and interactions of dark matter and axions, building on past TeO$_2$ bolometer experiments.
arXivarXiv · · January 16, 2018
0
21
First Results from CUORE: A Search for Lepton Number Violation via 0νββ0νββ Decay of 130^{130}Te
CUORE CollaborationC. AlduinoK. AlfonsoE. AndreottiC. ArnaboldiF. T. Avignone IIIO. AzzoliniI. BandacT. I. BanksG. BariM. BarucciJ.W. Beeman  +153
The CUORE experiment, a ton-scale cryogenic bolometer array, performed its first high-sensitivity search for $^{130}$Te neutrinoless double-beta decay ($0\nu\beta\beta$), a lepton-number-violating process. Based on 86.3 kg$\cdot$yr of TeO$_2$ exposure with an energy resolution of $(7.7 \pm 0.5)$ keV FWHM and background of $(0.014 \pm 0.002)$ counts/(keV$\cdot$kg$\cdot$yr), no evidence for $0\nu\beta\beta$ was found. The median sensitivity was $7.0\times10^{24}$ yr, and a lower limit of $T^{0\nu}_{1/2}(^{130}\text{Te}) > 1.3\times10^{25}$ yr (90% C.L.) was set. Combined with earlier experiments, the limit increased to $>1.5\times10^{25}$ yr, the most stringent yet, corresponding to an effective Majorana neutrino mass $m_{\beta\beta} < (110-520)$ meV.
arXivarXiv · · October 22, 2017
0
Search for Neutrinoless β+ECβ^{+}\hspace{-0.2em}EC Decay of 120^{120}Te with CUORE-0
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoA. BersaniM. BiassoniA. Branca  +106
CUORE-0 searches for the neutrinoless $\beta^{+}EC$ decay of $^{120}$Te, a lepton-number-violating process. A new analysis method simultaneously fits signals with different event topologies and data subsets with varying efficiencies. The resulting half-life limit is $T_{1/2}>1.6\times10^{21}$ yr at 90% CI. Combining this with earlier Cuoricino data yields the strongest limit to date, $T_{1/2}>2.7\times10^{21}$ yr at 90% CI.
arXivarXiv · · October 20, 2017
0
Low Energy Analysis Techniques for CUORE
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniG. BariJ.W. BeemanF. BelliniG. BenatoA. BersaniM. Biassoni  +112
This paper presents low-energy analysis techniques for CUORE, a tonne-scale cryogenic detector searching for neutrinoless double-beta decay of $^{130}$Te. To enable rare-event searches like solar axions or WIMP scattering, the energy threshold is improved to 10 keV. Using data from the CUORE-0 prototype (November 2013 – March 2015), the authors detail threshold optimization, trigger efficiency monitoring, event selection, and low-energy calibration. They also show the low-energy background spectrum below 60 keV and report CUORE's sensitivity to WIMP annual modulation based on CUORE-0's performance.
arXivarXiv · · August 25, 2017
0
36
CUORE Sensitivity to 0νββ0νββ Decay
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniT. I. BanksG. BariJ.W. BeemanF. BelliniG. BenatoA. Bersani  +119
The CUORE experiment's sensitivity to neutrinoless double beta decay is evaluated via a Bayesian toy Monte Carlo analysis. With expected background and energy resolution, the 90% credibility interval exclusion sensitivity on the half-life $T_{1/2}^{0\nu}$ reaches $2\times10^{25}$ yr after 3 months and $9\times10^{25}$ yr after 5 years of live time. The corresponding $3\sigma$ discovery sensitivities are $7\times10^{24}$ yr and $4\times10^{25}$ yr, respectively.
arXivarXiv · · May 30, 2017
0
71
The projected background for the CUORE experiment
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniT. I. BanksG. BariJ.W. BeemanF. BelliniG. BenatoA. Bersani  +120
The CUORE experiment searches for neutrinoless double beta decay of $^{130}\text{Te}$ using 988 TeO$_2$ bolometers at $∼10$ mK. To achieve a $9\times10^{25}$-year half-life exclusion sensitivity, the background rate in the region of interest must be $≤10^{-2}$ counts/keV/kg/y. This paper presents a detailed Monte Carlo simulation, built from material screening, radioassays, and bolometric measurements, that projects the expected background. The model has guided the experiment's construction and now provides the background estimate for the upcoming physics run.
arXivarXiv · · April 28, 2017
0
215
The CUORE and CUORE-0 experiments at LNGS
A. D&#39;AddabboC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniT. I. BanksG. BariJ.W. BeemanF. BelliniA. BersaniM. Biassoni  +113
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton bolometric experiment searching for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{130}$Te using 988 TeO$_2$ crystals at 10 mK. Its demonstrator, CUORE-0, operated from 2013 to 2015 and represents the largest $^{130}$Te bolometric setup ever run. This paper presents the final CUORE-0 $0\nu\beta\beta$ analysis and detector performance, together with the status of CUORE's construction and cryostat commissioning.
arXivarXiv · · December 13, 2016
0
1
Measurement of the Two-Neutrino Double Beta Decay Half-life of 130^{130}Te with the CUORE-0 Experiment
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniT. I. BanksG. BariJ.W. BeemanF. BelliniA. BersaniM. Biassoni  +114
The CUORE-0 experiment measured the two-neutrino double beta decay half-life of $^{130}$Te using a 33.4 kg$\cdot$y exposure of TeO$_2$. The result is $T_{1/2}^{2\nu} = [8.2 \pm 0.2\,(\text{stat.}) \pm 0.6\,(\text{syst.})] \times 10^{20}$ y, obtained after detailed reconstruction of the detector's counting rate and background sources, including those affecting the neutrinoless double beta decay region of interest.
arXivarXiv · · September 6, 2016
0
173
CUORE-0 detector: design, construction and operation
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniM. BalataT. I. BanksG. BariJ. W. BeemanF. BelliniA. Bersani  +142
The CUORE-0 detector, a prototype tower of 52 TeO$_2$ bolometers built using CUORE assembly procedures, operated at Laboratori Nazionali del Gran Sasso from 2013 to 2015. Its design, construction, and operation improved upon the predecessor Cuoricino, and data from CUORE-0 demonstrate that the design goals of the full 988-bolometer CUORE experiment for neutrinoless double-beta decay search are achievable.
arXivarXiv · · April 19, 2016
0
156
The CUORE Cryostat: A 1-Ton Scale Setup for Bolometric Detectors
C. LigiC. AlduinoF. AlessandriaM. BiassoniC. BucciA. CaminataL. CanonicaL. CappelliN. I. ChottS. CopelloA. D&#39;AddabboS. Dell&#39;Oro  +16
The CUORE cryostat, a 1-ton scale cryogen-free system based on pulse tubes and a custom high-power dilution refrigerator, cools a 988-crystal TeO$_2$ bolometric detector to around 10 mK. Commissioned in 2014 at Gran Sasso, it reached a record 6 mK on a cubic meter scale. This paper presents its thermal characteristics and cryogenic performance from commissioning runs.
arXivarXiv · · March 10, 2016
0
27
Frequent collaborators
C. Bucci (31)
A. Caminata (31)
L. Cappelli (31)
P. Gorla (31)
A. Nucciotti (31)
L. Pattavina (31)
V. Singh (31)
L. Taffarello (31)
M. Biassoni (30)
O. Cremonesi (30)
L. Marini (30)
C. E. Pagliarone (30)