MCP
CB

C. Bucci

137 papers in the library

Papers

30
Optimisation of TES design for the CRESST experiment
G. AngloherS. BanikA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. BurmeisterL. CanonicaE. CipelliS. Di LorenzoJ. Dohm  +45
This work presents an optimisation study of tungsten transition-edge sensors (W-TESs) for the CRESST dark matter experiment. By systematically investigating the thickness, dimensions, and material composition of phonon collectors, the authors demonstrate a significant improvement in the signal-to-noise ratio and overall detector performance, establishing new benchmarks for the sensors used in CRESST.
arXivarXiv · · May 8, 2026
0
3
Search for Sterile Neutrinos with CUPID-0
O. AzzoliniJ. W. BeemanF. BelliniM. BerettaM. BiassoniC. BrofferioC. BucciS. CapelliV. CaraccioloL. CardaniP. CarnitiN. Casali  +41
The CUPID-0 experiment searched for sterile neutrinos by looking for spectral distortions in the double beta decay of $^{82}$Se, which would be compatible with the emission of such a particle. Using a Zn$^{82}$Se exposure of 9.95 kg$\cdot$yr and a detailed background model down to 200 keV, the analysis tested sterile neutrino masses between 0.5 and 1.5 MeV. No signal was found, leading to 90% confidence-level upper limits on the mixing probability $\sin^2\theta$. The most stringent bound, $\sin^2\theta < 8 \times 10^{-3}$, was set for a sterile neutrino mass of 0.7 MeV.
arXivarXiv · · March 18, 2026
0
0
ImpCresst -- A versatile simulation tool focusing on solid-state detectors at keV energies
G. AngloherS. BanikA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. BurmeisterL. CanonicaF. CasadeiE. CipelliS. Di Lorenzo  +48
This paper introduces ImpCresst, a Geant4-based Monte Carlo tool for simulating backgrounds and calibration signals in solid-state detectors at keV energies. Originally developed by the CRESST collaboration, it features dynamic geometry from CAD files, ROOT-based data persistency, automatic metadata annotation, and a novel particle generator for radioactive bulk and surface contaminations independent of user-defined confinement volumes. The auxiliary tool CresstDS applies empirical detector-specific energy and time resolutions. The tool is designed for flexibility and suitability in heterogeneous detector environments.
arXivarXiv · · March 2, 2026
0
2
End-to-End Data Analysis Methods for the CUORE Experiment
D. Q. AdamsC. Alduino…C. Bucci
The CUORE experiment, a ton-scale array of cryogenic calorimeters operating at ~10 mK, achieved the most stringent limit on the neutrinoless double-beta ($0\nu\beta\beta$) decay half-life of $^{130}$Te. This work describes the end-to-end analysis tools and methods developed for CUORE, treating each calorimeter independently for optimization, data acquisition, and analysis. The core contribution is the detailed evaluation of the energy-dependent detector response and signal efficiency used in the latest $0\nu\beta\beta$ decay search, enabling high-quality datasets for multiple rare-event searches.
arXivarXiv · · October 29, 2025
0
3
Reconstruction of cosmic-ray muon events with CUORE
CUORE CollaborationD. Q. Adams…C. Bucci
By using the segmentation of the CUORE cryogenic detector array, a multi-objective optimization algorithm achieves in-situ 3D reconstruction of through-going cosmic-ray muons without time-of-flight estimation. The integral muon flux measured underground at the Laboratori Nazionali del Gran Sasso agrees with other experiments. This work is the first demonstration of 3D particle tracking with per-event angular determination in a millikelvin detector, critical for validating muon-related background in next-generation neutrinoless double-beta decay experiments.
arXivarXiv · · September 5, 2025
0
0
Description of CRESST-III lithium aluminate data
G. AngloherS. BanikG. BenatoA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. CanonicaA. D&#39;AddabboS. Di LorenzoL. Einfalt  +49
The paper describes the CRESST-III data set from two lithium aluminate detector modules operated in 2021, which produced the strongest spin-dependent dark matter cross-section limits for 0.25–1.5 GeV/c² masses. It specifies how to use the publicly available data to reproduce the reported dark matter results.
arXivarXiv · · August 5, 2025
0
1
Exploring the keV-scale physics potential of CUORE
CUORE CollaborationD. Q. Adams…C. Bucci
This paper reports the keV-scale analysis of the CUORE experiment using over 2 tonne yr of data. By applying stricter selection to optimize thresholds at 10 keV and 3 keV, the analysis achieves average baseline resolutions of 2.54 ± 0.14 keV and 1.18 ± 0.02 keV FWHM, respectively. The overall background is reduced by about an order of magnitude, reaching 2.06 ± 0.05 counts/(keV kg days) at 10 keV and 16 ± 2 counts/(keV kg days) at 3 keV. Near-threshold reconstruction efficiencies are evaluated for the first time, yielding 50 ± 2 % at 10 keV and 26 ± 4 % at 3 keV, demonstrating the scalability of tonne-scale cryogenic calorimeters for low-energy physics.
arXivarXiv · · May 29, 2025
0
5
The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment
D. Q. AdamsC. Alduino…C. Bucci
Using data from the CUORE experiment and the Copernicus Earth Observation program, this study reports the first detection of marine microseismic vibrations with mK-scale calorimeters. The analysis reveals seasonal Mediterranean Sea activity that impacts CUORE's energy thresholds, resolution, and sensitivity over four years, underscoring the need to address faint environmental noise in ultra-sensitive experiments. The paper also demonstrates a noise decorrelation algorithm using auxiliary sensors that reduces vibrational noise and improves detector performance.
arXivarXiv · · May 13, 2025
0
3
The CRESST experiment: towards the next-generation of sub-GeV direct dark matter detection
G. AngloherS. BanikA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. CanonicaE.R. CipelliS. Di LorenzoJ. DohmF. Dominsky  +45
The CRESST experiment upgrade will deploy about 100 detectors with masses from 2g to 24g to achieve unprecedented sensitivity to sub-GeV dark matter particles, focusing on spin-independent dark matter-nucleus scattering. The paper presents the experimental strategies, projected sensitivities, and approaches to mitigate low-energy excess backgrounds, which have been a key limitation in previous sub-GeV searches. A long-term roadmap for the next decade is also outlined.
arXivarXiv · · May 2, 2025
0
12
Sensitivity of the CUPID experiment to 0I^½I^2I^20νββ decay of 100^{100}Mo
K. AlfonsoA. Armatol…C. Bucci
CUPID, a next-generation bolometric experiment using 1596 Li$_2$MoO$_4$ crystals at ~10 mK in the CUORE cryostat, searches for neutrinoless double-beta decay of $^{100}$Mo. With a background of $1.0 \times 10^{-4}$ counts/keV/kg/yr and 5 keV FWHM energy resolution at the Q-value, its Bayesian 90% credible interval exclusion sensitivity gives a half-life $′T_{1/2} > 1.6 \times 10^{27}$ yr, corresponding to an effective Majorana neutrino mass $′m_{\beta\beta} < 9.6$--$28$ meV; the Frequentist 3σ discovery sensitivity is $′T_{1/2}= 1.0 \times 10^{27}$ yr, corresponding to $′m_{\beta\beta}= 12$--$36$ meV.
arXivarXiv · · April 19, 2025
0
Half-life and precision shape measurement of 2νββ decay of 130^{130}Te
D. Q. AdamsC. Alduino…C. Bucci
Using 1038 kg yr of CUORE data, the $2\nu\beta\beta$ half-life of $^{130}$Te is measured as $(9.32^{+0.05}_{-0.04}(\text{stat.})^{+0.07}_{-0.07}(\text{syst.}))\times10^{20}$ yr, doubling previous precision. The improved signal-to-background ratio enables the first application of the enhanced $2\nu\beta\beta$ formalism to $^{130}$Te, yielding an effective axial coupling credibility interval and higher-order nuclear matrix element ratios. The second-to-first ratio agrees with models, while the third-to-first deviates, providing nuclear model tests relevant to $0\nu\beta\beta$ searches.
arXivarXiv · · March 31, 2025
0
Search for fractionally charged particles with CUORE
CUORE CollaborationD. Q. Adams…C. Bucci
The Cryogenic Underground Observatory for Rare Events (CUORE), a 988-crystal TeO$_2$ array operating below 20 mK, is used to search for fractionally charged particles (FCPs) with charges between $e/24$ and $e/5$. Using the first tonne-year of exposure, no significant excess of FCP candidate tracks is found, leading to the most stringent limits on the underground FCP flux in this charge range at 90% confidence level. This work demonstrates the sensitivity of tonne-scale sub-Kelvin detectors to exotic particle signatures.
arXivarXiv · · June 18, 2024
0
15
Data-driven background model for the CUORE experiment
CUORE CollaborationD. Q. Adams…C. Bucci
We present a data-driven background model for the CUORE experiment, built from a Bayesian fit to energy spectra across a broad range using 1038.4 kg yr of exposure. The model exploits detector granularity, exposure, and operational stability to resolve spatial and time-dependent backgrounds, achieving sensitivity to bulk activities as low as 10 nBq kg$^{-1}$ and surface activities as low as 0.1 nBq cm$^{-2}$. The extracted contamination levels are compared with prior radio-assay data, informing future background mitigation strategies for CUORE and the CUPID experiment.
arXivarXiv · · May 28, 2024
0
36
First observation of single photons in a CRESST detector and new dark matter exclusion limits
CRESST CollaborationG. AngloherS. BanikG. BenatoA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. CanonicaA. D&#39;AddabboS. Di Lorenzo  +47
The CRESST-III experiment reports the first observation of single-luminescence photons in the eV range using a 0.6\,g silicon-on-sapphire cryogenic detector with an energy threshold of (6.7\, \pm \,0.2)\,eV and a baseline resolution of (1.0\, \pm \,0.2)\,eV. This calibration enabled new exclusion limits on dark matter-nucleon scattering that extend to dark matter particle masses below 100\,MeV/$c^{2}$.
arXivarXiv · · May 10, 2024
0
62
Constraints on Lepton Number Violation with the 2 tonne⋅\cdotyr CUORE Dataset
CUORE CollaborationD. Q. Adams…C. Bucci
The CUORE experiment searches for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te using a tonne-scale cryogenic calorimeter at milli-kelvin temperatures. With over 2 tonne$\cdot$year TeO$_2$ exposure, no evidence of $0\nu\beta\beta$ is found, yielding a lower limit on the half-life of $T_{1/2} > 3.5 \times 10^{25}$ years (90% C.I.). This result and the stable operation of nearly 1000 detectors demonstrate infrastructure for future searches.
arXivarXiv · · April 5, 2024
0
11
A likelihood framework for cryogenic scintillating calorimeters used in the CRESST dark matter search
CRESST CollaborationG. AngloherS. BanikG. BenatoA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. CanonicaA. D&#39;AddabboS. Di Lorenzo  +48
This paper presents a likelihood framework that models backgrounds and a potential dark matter signal in the two-dimensional plane of phonon and scintillation light energies for cryogenic scintillating calorimeters. Applied to CaWO4-based CRESST detectors, it is the first single framework in CRESST to simultaneously fit calibration and physics data and extract dark matter results in one step via a profile likelihood ratio test. The framework can be expanded to other materials and experiments.
arXivarXiv · · March 6, 2024
0
15
Optimal operation of cryogenic calorimeters through deep reinforcement learning
G. AngloherS. BanikG. BenatoA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. CanonicaA. D&#39;AddabboS. Di LorenzoL. Einfalt  +50
This paper automates the optimization of cryogenic phonon detectors with transition-edge sensors using deep reinforcement learning. The method tunes the thermometer temperature and bias current to achieve optimal detector performance. It was tested in simulation and on three real CRESST detectors in an underground setup, matching human-expert results in speed and quality. This reduces manual intervention, enabling large-scale detector tuning.
arXivarXiv · · November 26, 2023
0
5
Detector development for the CRESST experiment
G. AngloherS. BanikG. BenatoA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. CanonicaA. D&#39;AddabboS. Di LorenzoL. Einfalt  +46
The CRESST-III dark matter search faces a low-energy background that rises sharply below 200 eV, limiting its physics reach. To investigate this unexplained signal, the collaboration developed three new detector layouts. These designs are presented as a step toward understanding the background's origin and improving the sensitivity of low-mass dark matter direct detection.
arXivarXiv · · November 13, 2023
0
17
Light Dark Matter Search Using a Diamond Cryogenic Detector
CRESST CollaborationG. AngloherS. BanikG. BenatoA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. CanonicaA. D&#39;AddabboS. Di Lorenzo  +47
By operating diamond as a cryogenic calorimeter with a 16.8 eV energy threshold, this work sets exclusion limits on the elastic spin-independent dark matter–nucleon cross section down to dark matter masses of 0.122 GeV/c². Two 0.175 g CVD diamond samples instrumented with tungsten transition-edge sensors were measured. The limits demonstrate the scientific potential of diamond as a target material for low-mass dark matter direct detection.
arXivarXiv · · October 9, 2023
0
11
Measurement of the 2νββνββ Decay Half-Life of Se-82 with the Global CUPID-0 Background Model
O. AzzoliniJ. W. BeemanF. BelliniM. BerettaM. BiassoniC. BrofferioC. BucciS. CapelliV. CaraccioloL. CardaniP. CarnitiN. Casali  +40
Using the CUPID-0 global background model that combines two measurement campaigns (8.82 kg·yr exposure of \(^{82}\)Se), the background sources around 3 MeV are identified with improved precision, supporting the neutrinoless double-beta decay search for next-generation CUPID. The two-neutrino double-beta decay half-life of \(^{82}\)Se is measured with unprecedented accuracy: \(T_{1/2}^{2\nu} = [8.69 \pm 0.05 \text{(stat.)}~^{+0.09}_{-0.06} \text{(syst.)}] \times 10^{19}~\text{yr}\).
arXivarXiv · · June 26, 2023
0
Twelve-crystal prototype of Li2_2MoO4_4 scintillating bolometers for CUPID and CROSS experiments
CUPIDCROSS collaborations…C. Bucci
This paper reports the construction and long-term operation of a twelve-crystal array of Li$_2$MoO$_4$ scintillating bolometers, each 0.28 kg, equipped with 16 Ge light detectors, to optimize detector design for the CROSS and CUPID double-beta decay experiments. The study systematically varied phonon sensor size, Ge detector shape and supplier, and light collection conditions (reflector and surface coating). The array ran for eight months in a low-background cryostat at Canfranc, achieving sensitivity to radioactive contamination at the $\mu$Bq/kg level for $^{228}$Th and $^{226}$Ra.
arXivarXiv · · April 10, 2023
0
20
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
CUPID collaborationK. Alfonso…C. Bucci
This paper reports the first test of CUPID-design bolometric light detectors with NTD-Ge sensors inside a pulse-tube cryostat, a setting that introduces strong mechanical vibrations. Each of the four tested detectors achieved a baseline noise well below the CUPID goal of 100 eV RMS, with measured values of 70–90 eV RMS. One detector reached an energy resolution of 0.71(5) keV FWHM at the 356 keV line of a $^{133}$Ba source, the best reported for any gamma detector in that energy range. The results validate the detector design for the CUPID neutrinoless double-beta decay experiment.
arXivarXiv · · April 10, 2023
0
14
Results on sub-GeV Dark Matter from a 10 eV Threshold CRESST-III Silicon Detector
CRESST CollaborationG. AngloherS. BanikG. BenatoA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. CanonicaA. D&#39;AddabboS. Di Lorenzo  +50
The CRESST-III experiment reports a new limit on spin-independent dark matter–silicon scattering using a 0.35 g cryogenic calorimeter with the lowest-ever baseline nuclear recoil energy resolution of $(1.36\pm 0.05)$ eV$_{\text{nr}}$ and a threshold of $(10.0\pm 0.2)$ eV$_{\text{nr}}$. This improves sensitivity to sub-GeV dark matter (mass below 160 MeV/c$^2$) by up to 20× over earlier results. The observed low-energy excess is characterized, ruling out noise triggers and surface radioactive contamination as dominant sources.
arXivarXiv · · December 23, 2022
0
90
Towards an automated data cleaning with deep learning in CRESST
G. AngloherS. BanikD. BartolotG. BenatoA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. CanonicaA. D&#39;AddabboS. Di Lorenzo  +53
For the CRESST dark matter experiment, the authors frame the manual cleaning of cryogenic calorimeter signals—removing pile-up and read-out artefacts—as a time-series classification task. Testing four neural network architectures on over one million labeled records from 68 detectors, their best model achieves 0.932 balanced accuracy. They further show that about half of the model's errors on one detector are actually mislabeled data, and most remaining errors have context-dependent ground truth, demonstrating that the trained classifiers are well suited for automated data cleaning.
arXivarXiv · · November 1, 2022
0
30
Search for Majoron-like particles with CUPID-0
CUPID-0 CollaborationO. AzzoliniJ.W. BeemanF. BelliniM. BerettaM. BiassoniC. BrofferioC. BucciS. CapelliV. CaraccioloL. CardaniP. Carniti  +41
Using scintillating cryogenic calorimeters, the CUPID-0 experiment performed the first search for Majoron-emitting neutrinoless double beta decay ($0\nu\beta\beta\chi_0$) of $^{82}$Se. Bayesian analysis of Phase I data found no evidence for such decays across four spectral indices ($n=1,2,3,7$) corresponding to different Majoron-like boson models. The resulting lower limits on the half-life range from $1.2\times10^{23}$ yr ($n=1$) to $2.2\times10^{21}$ yr ($n=7$), representing the best constraints on $0\nu\beta\beta\chi_0$ for $^{82}$Se to date.
arXivarXiv · · September 20, 2022
0
27
Latest observations on the low energy excess in CRESST-III
G. AngloherS. BanikG. BenatoA. BentoA. BertoliniR. BreierC. BucciL. CanonicaA. D&#39;AddabboS. Di LorenzoL. EinfaltA. Erb  +48
The CRESST-III experiment reports an unexplained low-energy excess in its latest data. By comparing detectors with different designs, the collaboration finds that the excess shows no dependence on time, energy, or temperature in ways that would be consistent with dark matter, radioactive backgrounds, or intrinsic crystal-bulk sources. These observations rule out those major candidate explanations, narrowing the search for the origin of the excess.
arXivarXiv · · July 19, 2022
0
47
Testing spin-dependent dark matter interactions with lithium aluminate targets in CRESST-III
G. AngloherS. BanikG. BenatoA. BentoA. BertoliniR. BreierC. BucciJ. BurkhartL. CanonicaA. D&#39;AddabboS. Di LorenzoL. Einfalt  +49
The CRESST-III experiment operated two 10.46 g LiAlO$_2$ cryogenic detector modules and used the odd-proton/odd-neutron isotopes $^6$Li, $^7$Li, and $^{27}$Al to achieve the currently strongest upper limits on the spin-dependent dark matter-nucleon cross section for dark matter masses between 0.25 and 1.5 GeV/c$^2$.
arXivarXiv · · July 15, 2022
0
69
Final Result on the Neutrinoless Double Beta Decay of 82^{82}Se with CUPID-0
O. AzzoliniJ. W. BeemanF. BelliniM. BerettaM. BiassoniC. BrofferioC. BucciS. CapelliV. CaraccioloL. CardaniP. CarnitiN. Casali  +36
Using the full 8.82 kg·yr exposure from both phases of the CUPID-0 experiment, which employed Zn$^{82}$Se cryogenic calorimeters, the most stringent limit on the neutrinoless double beta decay of $^{82}$Se is set. The half-life to the ground state of $^{82}$Kr exceeds $4.6 \times 10^{24}$ yr (90% credible interval), corresponding to an effective Majorana neutrino mass $m_{\beta\beta} < (263-545)$ meV. New lower limits on decays to excited states are also reported.
arXivarXiv · · June 10, 2022
0
0
New direct limit on neutrinoless double beta decay half-life of 128^{128}Te with CUORE
D. Q. AdamsC. Alduino…C. Bucci
The CUORE experiment, a ton-scale cryogenic detector searching for neutrinoless double beta ($0\nu\beta\beta$) decay in $^{130}$Te, reports its first results for $^{128}$Te. No evidence of decay is found. A Bayesian analysis sets a lower limit on the half-life of $T_{1/2} > 3.6 \times 10^{24}$ yr (90% CI), the most stringent direct limit, improving over previous direct searches by a factor of 30 and surpassing geochemical constraints for the first time.
arXivarXiv · · May 6, 2022
0
0
Toward CUPID-1T
A. ArmatolC. Augier…C. Bucci
This paper outlines the roadmap toward CUPID-1T, a next-to-next generation ton-scale calorimetric experiment that targets a sensitivity to the neutrinoless double-beta decay half-life beyond $10^{28}$ years and $m_{\beta\beta}\lesssim 15$ meV, covering the Inverted Ordering region and exploring the Normal Ordering parameter space. The work reviews ongoing projects in background reduction, cryogenic readout, and beyond-$0\nu\beta\beta$ physics that underpin this detector.
arXivarXiv · · March 16, 2022
0
15
Frequent collaborators
P. Gorla (112)
L. Pattavina (90)
L. Canonica (84)
G. Pessina (74)
A. Giuliani (73)
S. Pirro (73)
E. Previtali (73)
C. Brofferio (72)
S. Capelli (72)
O. Cremonesi (72)
M. Pavan (72)
S. Di Domizio (70)