MCP
CC

C. Chapron

15 papers in the library

Papers

15
The coded mask of the ECLAIRs telescope onboard the SVOM space mission
C. LachaudA. GivaudanM. KarakacW. BertoliS. DheillyC. JuffroyC. ChapronA. GrosS. SchanneS. BegocP. GuillemotH. Pasquier
The ECLAIRs hard X-ray telescope on the SVOM mission extends coded-mask imaging down to an unusually low 4 keV while maintaining performance up to 150 keV. This required a novel self-supporting coded mask, developed through dedicated pattern-generation algorithms and an innovative stiffened sandwich structure to meet both scientific and mechanical requirements. The paper presents the rationale, development, and final implementation of this mask.
arXivarXiv · · April 27, 2026
0
Measuring the CMB primordial B-modes with Bolometric Interferometry
A. MennellaP. Ade…C. Chapron
Bolometric interferometry, as realized by the QUBIC instrument, combines the sensitivity of bolometric detectors with the systematic control of interferometry for measuring the CMB's primordial B-modes. A unique feature is 'spectral imaging', which provides in-band spectral resolution $\Delta\nu/\nu \sim 0.04$—unattainable by traditional imagers—to control Galactic foreground contamination. This paper describes the technique's principles, QUBIC's current status, and prospects.
arXivarXiv · · November 5, 2023
0
Status of QUBIC, the Q&U Bolometer for Cosmology
L. MoussetP. Ade…C. Chapron
QUBIC is a novel polarimeter combining interferometry and bolometric detectors to measure the B-mode polarization of the CMB, a signal of a few tens of nK. Its design uses interferometry for systematic control and bolometers for wide-band, background-limited sensitivity, with multichroic observations to handle astrophysical foregrounds. The paper reports the instrument's status.
arXivarXiv · · October 6, 2022
0
0
QUBIC IV: Performance of TES Bolometers and Readout Electronics
M. PiatG. Stankowiak…C. Chapron
QUBIC IV reports the performance of its 256 NbSi transition edge sensor (TES) bolometers and time-domain multiplexing readout. The low-noise amplifier achieved 0.3 nV/Hz$^{-0.5}$ white noise, and about 80% of detectors operated within specifications. The instrument noise equivalent power was about 2×10$^{-16}$ W/Hz$^{-0.5}$, sufficient for demonstrating bolometric interferometry, though limited by microphonics and noise aliasing.
arXivarXiv · · January 17, 2021
0
36
QUBIC I: Overview and ScienceProgram
J.-Ch. HamiltonL. Mousset…C. Chapron
QUBIC is a novel bolometric interferometer for CMB B-mode polarization that combines the systematic-error control of interferometry with the wide-band sensitivity of bolometers. Its synthesized beam's frequency-dependent shape enables multi-sub-band polarization mapping within the 150 and 220 GHz bands, aiding foreground removal. Simulations for three years of observation from Argentina, assuming perfect foreground subtraction and stable atmosphere, yield a statistical sensitivity to the effective tensor-to-scalar ratio of $\sigma(r)=0.015$.
arXivarXiv · · November 4, 2020
0
QUBIC II: Spectro-Polarimetry with Bolometric Interferometry
L. MoussetM.M. Gamboa Lerena…C. Chapron
This paper reports that bolometric interferometry enables spectral imaging, allowing a single instrument to reconstruct sky maps in multiple sub-bands from a wide frequency band. Using the QUBIC instrument, the authors demonstrate point-source reconstruction and Galactic dust mapping, characterize the frequency-dependent point spread function, and study noise correlations between sub-bands via simulations. They conclude that with QUBIC, spectral imaging performance is nearly optimal for up to five sub-bands, offering a method to separate CMB B-mode polarization from astrophysical foregrounds.
arXivarXiv · · October 28, 2020
0
0
QUBIC V: Cryogenic system design and performance
S. MasiE.S. BattistelliP. de BernardisC. ChapronF. ColumbroG. D'AlessandroM. De PetrisL. GrandsireJ.-Ch. HamiltonS. MarnierosL. MeleA. May  +117
The QUBIC experiment's cryogenic system, designed for long-duration CMB polarization measurements, is presented. The system uses two pulse-tube refrigerators to cool a ~1 m³, ~165 kg instrument to ~3K. A ⁴He evaporator cools the beam combiner to ~1K, and a ³He evaporator cools the detector arrays to ~0.33K. The system operated stably for over six months, and tilting from 20° to 90° elevation caused no significant temperature changes, confirming readiness for deployment.
arXivarXiv · · August 24, 2020
0
29
QUBIC VI: cryogenic half wave plate rotator, design and performances
G. D'AlessandroL. Mele…C. Chapron
The QUBIC Stokes polarimeter rotates a half-wave plate (HWP) at cryogenic temperature to modulate polarization while minimizing spurious signals from optical element emissivity. Its rotation is driven by an external stepper motor to avoid thermal load at low temperature. Tests show positioning precision below 0.1° and an extra power load of only a few mK on the ~8 K cryogenic stage.
arXivarXiv · · August 24, 2020
0
QUBIC III: Laboratory Characterization
S.A. TorchinskyJ.-Ch. HamiltonM. PiatE.S. BattistelliC. ChapronG. D'AlessandroP. de BernardisM. De PetrisM.M. Gamboa LerenaM. GonzálezL. GrandsireS. Masi  +116
The QUBIC Technological Demonstrator successfully validates bolometric interferometry through laboratory characterization. A prototype scanned a far-field modulated millimeter-wave source to produce synthesized beam maps, achieving measured beams matching theoretical simulations and enabling spectro-imaging. Polarization performance showed less than 0.5% cross-polarization rejection. The instrument is now ready for deployment in Argentina.
arXivarXiv · · August 23, 2020
0
28
QUBIC VIII: Optical design and performance
C. O'SullivanM. De PetrisG. AmicoE.S. BattistelliD. BurkeD. BuziC. ChapronL. ConversiG. D'AlessandroP. de BernardisM. De LeoD. Gayer  +117
QUBIC uses bolometric interferometry to detect CMB B-mode polarisation around the recombination peak. A cold reflective combiner overlays beams from 400 feedhorns onto two focal planes, combining imager sensitivity with interferometer systematic-error control. A fixed groundshield and a moving forebaffle limit local contamination. The paper presents the optics modelling, design, manufacturing, and preliminary measurements.
arXivarXiv · · August 23, 2020
0
36
QUBIC: the Q & U Bolometric Interferometer for Cosmology
E.S. BattistelliP. Ade…C. Chapron
QUBIC combines Transition Edge Sensor bolometers with interferometric techniques to measure the faint polarization signal of the cosmic microwave background left by inflation. This hybrid design achieves the sensitivity of cryogenic detectors and the systematic-error control of an interferometer, distinguishing it from classical imaging CMB experiments. The instrument, demonstrated in the lab, will be deployed in Argentina at the end of 2019.
arXivarXiv · · January 28, 2020
0
21
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
M. PiatB. BélierL. BergéN. BleurvacqC. ChapronS. DheillyL. DumoulinM. GonzálezL. GrandsireJ.-Ch. HamiltonS. Henrot-VersilléD.T. Hoang  +126
QUBIC is a ground-based CMB experiment that measures polarized fluctuations using bolometric interferometry, combining the systematic-immunity of an interferometer with the sensitivity of cryogenic detectors. Its detection chain uses 2048 NbSi Transition Edge Sensors (TESs) cooled to 350 mK, read out via time-domain multiplexing (MUX factor 128) with SQUIDs at 1 K and a SiGe ASIC at 60 K. Characterization results from a reduced detector setup are presented, focusing on the detectors and readout system.
arXivarXiv · · November 27, 2019
0
Thermal architecture for the QUBIC cryogenic receiver
A.J. MayC. ChapronG. CoppiG. D'AlessandroP. de BernardisS. MasiS. MelhuishM. PiatL. PiccirilloA. SchillaciJ.-P. ThermeauP. Ade  +118
The QUBIC cryogenic receiver uses a four-stage thermal architecture (40 K, 4 K, 1 K, 350 mK) driven by two pulse tube coolers, a novel 4He sorption cooler, and a double-stage 3He/4He sorption cooler. This design enables bolometric interferometry for measuring the B-mode polarization of the cosmic microwave background. The paper presents the thermal and mechanical design, modeling, and laboratory cryogenic testing of the receiver.
arXivarXiv · · November 6, 2018
0
11
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background
A. MennellaP.A.R. Ade…C. Chapron
QUBIC is a novel instrument that combines the sensitivity of bolometric detectors with the systematic-effects control of interferometers to detect polarized signals from the cosmic microwave background, specifically primordial gravitational waves. Its key contribution is "self-calibration", a technique intrinsic to its interferometric design that removes instrumental effects from the measured data. The first module, a dual-band instrument at 150 GHz and 220 GHz, was set for deployment in Argentina in fall 2018.
arXivarXiv · · January 11, 2018
0
3
QUBIC Technical Design Report
J. AumontS. Banfi…C. Chapron
The QUBIC instrument is designed to measure CMB B-mode polarization anisotropies at multipoles 30–200. It is a bolometric interferometer that combines background-limited Transition-Edge-Sensor sensitivity with systematic control via interference fringe patterns, operating at two frequencies to separate polarized foregrounds from primordial B-mode signal. This Technical Design Report provides a detailed description of its characteristics.
arXivarXiv · · September 14, 2016
0
15
Frequent collaborators
A. Mennella (14)
J. Aumont (14)
S. Banfi (14)
P. de Bernardis (14)
M. Bersanelli (14)
D. Buzi (14)
F. Cavaliere (14)
P. Chanial (14)
A. Coppolecchia (14)
G. De Gasperis (14)
M. De Petris (14)
A. Etchegoyen (14)