MCP
CA

C. E. Aalseth

24 papers in the library

Papers

24
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
DarkSide CollaborationC. E. AalsethS. AbdelhakimF. AcerbiP. AgnesR. AjajI. F. M. AlbuquerqueT. AlexanderA. AliciA. K. AltonP. AmaudruzF. Ameli  +319
The DArT in ArDM experiment is a small, ultra-radio-pure detector designed to measure the $^{39}$Ar content of underground argon (UAr) for the DarkSide-20k dark matter search. It will be placed at the center of the ArDM detector, which acts as an active veto against background radioactivity. The article describes the chamber's design, construction, and background requirements needed to achieve the performance required for the Global Argon Dark Matter Collaboration.
arXivarXiv · · January 22, 2020
0
49
Search for Zero-Neutrino Double Beta Decay in 76Ge with the Majorana Demonstrator
C.E. AalsethN. AbgrallE. AguayoS.I. AlvisM. AmmanI.J. ArnquistF.T. Avignone IIIH.O. BackA.S. BarabashP.S. BarbeauC.J. BartonP.J. Barton  +117
The Majorana Demonstrator searches for neutrinoless double-beta decay in $^{76}$Ge using an array of high-purity Ge detectors. With an unprecedented energy resolution of 2.5 keV FWHM at the $Q$-value and a very low background, no candidate events were observed in 10 kg yr of enriched Ge exposure, yielding a lower half-life limit of $1.9\times10^{25}$ yr (90% CL). This constrains the effective Majorana neutrino mass to 240–520 meV, depending on nuclear matrix elements.
arXivarXiv · · October 31, 2017
0
DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
C. E. AalsethF. AcerbiP. AgnesI. F. M. AlbuquerqueT. AlexanderA. AliciA. K. AltonP. AntonioliS. ArcelliR. ArditoI. J. ArnquistD. M. Asner  +273
DarkSide-20k is a planned 20-tonne fiducial-mass two-phase liquid argon TPC for direct WIMP detection. Building on DarkSide-50, it achieves an instrumental background-free experiment (less than 0.1 expected non-neutrino events) by combining underground argon to suppress ³⁹Ar, a pulse-shape-based electron/nuclear recoil rejection factor greater than 3×10⁹, and a liquid scintillator plus water Cherenkov veto system. With a 5-year run (100 t·yr exposure), it targets WIMP-nucleon cross-section sensitivities of 1.2×10⁻⁴⁷ cm² for 1 TeV/c² WIMPs and 1.1×10⁻⁴⁶ cm² for 10 TeV/c² WIMPs.
arXivarXiv · · July 25, 2017
0
674
Cryogenic Characterization of FBK RGB-HD SiPMs
C. E. AalsethF. AcerbiP. AgnesI. F. M. AlbuquerqueT. AlexanderA. AliciA. K. AltonP. AmpudiaP. AntonioliS. ArcelliR. ArditoI. J. Arnquist  +259
FBK RGB-HD SiPMs, developed for the DarkSide program, are characterized cryogenically between 40 K and 300 K. The low-quenching-resistance variant (RGB-HD-LR$_q$) operates across this range with gains of $10^5$ to $10^6$ and primary dark noise rates of a few Hz/mm$^2$, measured via a custom setup and analysis software. This establishes the viability of these SiPMs for low-background, low-temperature applications such as liquid argon dark matter detectors.
arXivarXiv · · May 19, 2017
0
30
Development of a low-level Ar-37 calibration standard
R. M. WilliamsC. E. AalsethT. W. BowyerA. R. DayE. S. FullerD. A. HaasJ. C. HayesE. W. HoppeP. H. HumbleM. E. KeillorB. D. LaFerriereE. K. Mace  +7
This paper reports progress at Pacific Northwest National Laboratory in developing a process to generate and quantify low-level Ar-37 calibration standards. The standards are designed for calibrating sensitive field measurement instruments at activity levels consistent with soil background, using Ar-37 as an environmental signature of underground nuclear explosions. The work includes measurement analysis, assumptions, and uncertainty estimates.
arXivarXiv · · March 4, 2016
0
Development of a low background liquid scintillation counter for a shallow underground laboratory
J. L. ErchingerC. E. AalsethB. E. BernackiM. DouglasE. S. FullerM. E. KeillorS. M. MorleyC. A. MullenJ. L. OrrellM. E. PaniskoG. A. WarrenR. O. Williams  +1
The authors report the design and background evaluation of a low-background liquid scintillation counter intended for a shallow underground laboratory (35 m water equivalent overburden) at Pacific Northwest National Laboratory. The counter combines high-efficiency detection of charged-particle-emitting isotopes (e.g., β, α) in a liquid scintillation cocktail with a low-background shield and the underground environment. A series of simulations assessed the shield design requirements and achievable background rate. The goal is to enable increased-sensitivity measurements of low-concentration radioisotopes in environmental samples.
arXivarXiv · · December 21, 2015
0
Maximum Likelihood Signal Extraction Method Applied to 3.4 years of CoGeNT Data
C.E. AalsethP.S. BarbeauJ. Diaz LeonJ.E. FastT.W. HossbachA. KnechtM.S. KosM.G. MarinoH.S. MileyM.L. MillerJ.L. Orrell
A maximum likelihood analysis of 3.4 years of CoGeNT data (1136 live days) extracts a possible dark matter signal using 2D probability density functions for energy and annual modulation, plus pulse rise-time. The best-fit signal matches earlier reports, but its statistical significance is only 1.7 σ, well below the evidentiary threshold.
arXivarXiv · · January 24, 2014
0
Search for An Annual Modulation in Three Years of CoGeNT Dark Matter Detector Data
C.E. AalsethP.S. BarbeauJ. ColaresiJ.I. CollarJ. Diaz LeonJ.E. FastN.E. FieldsT.W. HossbachA. KnechtM.S. KosM.G. MarinoH.S. Miley  +3
This paper analyzes 3.4 years of CoGeNT data searching for the annual modulation expected from WIMP dark matter. A persistent modulation is found, concentrated in an energy region with an unexplained exponential excess. Its phase and period match expectations, but its amplitude is 4–7 times larger than standard halo predictions. The authors suggest a non-Maxwellian local velocity distribution as a possible explanation for the discrepancy.
arXivarXiv · · January 14, 2014
0
A Segmented, Enriched N-type Germanium Detector for Neutrinoless Double Beta-Decay Experiments
L. E. LevinerC. E. AalsethM. W. AhmedF. T. Avignone IIIH. O. BackA. S. BarabashM. BoswellL. De BraeckeleerV. B. BrudaninY-D ChanV. G. EgorovS. R. Elliott  +18
This paper characterizes the SEGA (Segmented, Enriched Germanium Assembly), the first segmented N-type germanium detector isotopically enriched to 85% in $^{76}$Ge, developed as a prototype for the Majorana neutrinoless double beta-decay experiment. The central contribution is demonstrating that, under the tested conditions, all but two detector segments achieve a resolution below 4 keV full width at half maximum (FWHM) at the 2039 keV Q-value, meeting the Majorana resolution goal, with all channels below 4.5 keV FWHM. General characteristics such as bias potential, efficiency, leakage current, and integral cross-talk are also reported for this detector in its temporary cryostat.
arXivarXiv · · April 19, 2013
0
CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors
C. E. AalsethP. S. BarbeauJ. ColaresiJ. I. CollarJ. Diaz LeonJ. E. FastN.E. FieldsT. W. HossbachA. KnechtM. S. KosM. G. MarinoH. S. Miley  +3
CoGeNT uses p-type point-contact germanium detectors to search for low-mass dark matter (WIMP mass ~10 GeV/c²). The low energy threshold and surface background rejection enable the study of the annual modulation signature expected from WIMP interactions. A detailed background model and simulations fail to explain the observed low-energy event excess or its temporal variation, ruling out known backgrounds. This work also reports the first energy-dependent determination of surface-event contamination, concluding that the technology is well suited for probing the DAMA/LIBRA-favored parameter region.
arXivarXiv · · August 28, 2012
0
Search for an Annual Modulation in a P-type Point Contact Germanium Dark Matter Detector
C.E. AalsethP.S. BarbeauJ. ColaresiJ.I. CollarJ. Diaz LeonJ.E. FastN. FieldsT.W. HossbachM.E. KeillorJ.D. KephartA. KnechtM.G. Marino  +6
Analysis of 15 months of CoGeNT data from a p-type point-contact germanium detector reveals a modulated component with statistical significance of about 2.8 sigma, prima facie compatible with a light-mass WIMP galactic halo. The result is limited by the short exposure and does not establish a definitive dark matter signal.
arXivarXiv · · June 3, 2011
0
Measurement of 37Ar to support technology for On-site Inspection under the Comprehensive Nuclear-Test-Ban Treaty
C. E. AalsethA. R. DayD. A. HaasE. W. HoppeB. J. HyronimusM. E. KeillorE. K. MaceJ. L. OrrellA. SeifertV. T. Woods
This paper presents a low-background internal-source gas proportional counter for measuring Argon-37 (³⁷Ar), a radionuclide signature of underground nuclear explosions produced via ⁴⁰Ca(n,α)³⁷Ar. The counter achieves a ³⁷Ar measurement sensitivity of 45.1 mBq/SCM in whole air, supporting On-Site Inspection under the Comprehensive Nuclear-Test-Ban Treaty by leveraging the 35-day half-life of ³⁷Ar for high specific activity and sufficient inspection time.
arXivarXiv · · August 4, 2010
0
Astroparticle Physics with a Customized Low-Background Broad Energy Germanium Detector
MAJORANA CollaborationC.E. AalsethM. AmmanF.T. Avignone IIIH.O. BackA.S. BarabashP.S. BarbeauM. BergevinF.E. BertrandM. BoswellV. BrudaninW. Bugg  +91
This paper reports on the characterization of a customized low-background Broad Energy Germanium (BEGe) detector, developed as part of the MAJORANA program. The detector, deployed at the Kimballton Underground Research Facility, offers low electronic noise, excellent pulse shape discrimination, and simple fabrication. These features make it a promising candidate for neutrinoless double-beta decay searches with $^{76}$Ge and for dark matter searches in the 1–10 GeV/$c^2$ mass range, demonstrating the feasibility of larger-scale experiments.
arXivarXiv · · July 19, 2010
0
25
Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
C.E. AalsethP.S. BarbeauN.S. BowdenB. Cabrera-PalmerJ. ColaresiJ.I. CollarS. DazeleyP. de LurgioG. DrakeJ.E. FastN. FieldsC.H. Greenberg  +15
Operating an ultra-low-noise p-type point contact germanium detector at 2,100 m.w.e. and employing a new surface-event rejection technique, this work reports the first observation of several cosmogenic peaks and an irreducible excess of bulk-like events below 3 keVee. The excess is examined for consistency with a dark matter candidate that could explain the DAMA/LIBRA annual modulation and a CDMS signal hint, and improved constraints on a cosmological origin for the DAMA/LIBRA effect are placed.
arXivarXiv · · February 25, 2010
0
Real-time digital signal processor implementation of self-calibrating pulse-shape discriminator for high purity germanium
R. SuarezJ. L. OrrellC. E. AalsethT. W. HossbachH. S. Miley
This paper presents a hardware real-time digital signal processor that implements a self-calibrating parametric pulse-shape discriminator for high-purity germanium detectors. The processor distinguishes single-site from multi-site gamma-ray interactions directly on-line, reproducing the results of an original off-line analysis routine with no significant difference. By reducing the recorded information per event, it enables higher duty-cycle data acquisition while retaining the benefits of pulse-shape-based event characterization.
arXivarXiv · · December 4, 2007
0
The IGEX experiment revisited: a response to the critique of Klapdor-Kleingrothaus,Dietz, and Krivosheina
C.E. Aalseth
This paper defends the IGEX lower limit for the half-life of $^{76}$Ge neutrinoless double-beta decay, $1.57 \times 10^{25}$ y, against a critique that claimed an arithmetical error. The authors answer each question raised and conclude that the original limit is correct, directly contradicting the asserted mistake.
arXivarXiv · · April 27, 2004
0
Pulse Shape Discrimination in the IGEX Experiment
D. GonzalezJ. MoralesS. CebrianE. GarciaI.G. IrastorzaA. MoralesA. Ortiz de SolorzanoJ. PuimedonM.L. SarsaJ.A. VillarC.E. AalsethF.T. Avignone III  +12
The IGEX experiment searched for neutrinoless double beta decay of $^{76}$Ge using enriched germanium detectors at the Canfranc Underground Laboratory. This work describes the implementation of Pulse Shape Discrimination (PSD) to reduce radioactive background. Applied to part of the IGEX data, PSD rejected about 60% of background events in the 2–2.5 MeV region of interest, lowering the background rate to approximately 0.09 counts/(keV kg y).
arXivarXiv · · February 14, 2003
0
The Igex 76ge Neutrinoless Double-Beta Decay Experiment: Prospects for Next Generation Experiments
C. E. AalsethF. T. Avignone IIIR. L. BrodzinskiS. CebrianE. GarciaD. GonzalezW. K. HensleyI. G. IrastorzaI. V. KirpichnikovA. A. KlimenkoH. S. MileyA. Morales  +13
The International Germanium Experiment (IGEX) set a lower bound on the half-life of neutrinoless double-beta decay in $^{76}$Ge at $T_{1/2}(0\nu) > 1.57 \times 10^{25}$ yr (90% C.L.) using 117 mole yr of data from 86% enriched detectors with pulse-shape discrimination. This implies an upper bound on the Majorana neutrino mass $\langle m_\nu \rangle$ between 0.33 eV and 1.35 eV, depending on nuclear matrix elements.
arXivarXiv · · February 12, 2002
0
Comment on "Evidence for Neutrinoless Double Beta Decay"
C. E. AalsethF. T. Avignone IIIA. BarabashF. BoehmR. L. BrodzinskiJ. I. CollarP. J. DoeH. EjiriS. R. ElliottE. FioriniR.J. GaitskellG. Gratta  +14
This comment refutes the claim of experimental observation of neutrinoless double-beta decay. It identifies limitations in the original analysis and concludes that the evidence does not support the reported discovery.
arXivarXiv · · February 7, 2002
0
The Majorana Ge-76 Double-Beta Decay Project
Majorana CollaborationC.E. AalsethD. AndersonF.T. Avignone IIIA. BarabashT.W. BowyerR.L. BrodzinskiV. BrudaninJ.I. CollarP.J. DoeS. EgorovS.R. Elliott  +20
The Majorana project aims to search for neutrinoless double-beta decay in $^{76}$Ge using 500 kg of isotopically enriched germanium arranged as 200 segmented detectors with pulse-shape analysis. The predicted half-life sensitivity is $4.2 \times 10^{27}$ years, corresponding to an effective Majorana neutrino mass $\langle m_\nu \rangle$ between 0.02 and 0.07 eV depending on nuclear matrix elements.
arXivarXiv · · January 11, 2002
0
0
Present status of IGEX dark matter search at Canfranc Underground Laboratory
I.G. IrastorzaA. MoralesC.E. AalsethF.T. Avignone IIIR.L. BrodzinskiS. CebrianE. GarciaI.V. KirpichnikovA.A. KlimenkoH.S. MileyJ. MoralesA. Ortiz de Solorzano  +10
The IGEX 76Ge detector, operating in the Canfranc Underground Laboratory, searches for WIMP dark matter via nuclear recoils from elastic scattering. Analyzing 40 days of data with a 4 keV threshold, a new exclusion plot for spin-independent WIMP-nucleon interactions is derived. This plot improves limits from other germanium detectors for WIMP masses 20–200 GeV, and for the first time enters the region claimed by DAMA's annual modulation effect using only raw data, excluding its upper left part.
arXivarXiv · · November 22, 2001
0
Improved constraints on WIMPs from the International Germanium Experiment IGEX
A. MoralesC.E. AalsethF.T. Avignone IIIR.L. BrodzinskiS. CebrianE. GarciaI.G. IrastorzaI.V. KirpichnikovA.A. KlimenkoH.S. MileyJ. MoralesA. Ortiz de Solorzano  +10
The IGEX Collaboration used a ⁷⁶Ge double-beta decay detector in the Canfranc Underground Laboratory to search for dark matter WIMPs via nuclear recoil. Analyzing 40 days of data with an energy threshold of ~4 keV, they derived new exclusion limits for spin-independent WIMP-nucleon interactions. These limits improve on previous germanium ionization detectors in the 20–200 GeV mass range, where the DAMA annual modulation signal would lie. The IGEX exclusion contour enters the DAMA region for the first time using raw data, excluding its upper left part. The authors note that moderate detector improvements could fully explore the DAMA region.
arXivarXiv · · October 25, 2001
0
Recent results from the canfranc dark matter search with germanium detectors
I. G. IrastorzaA. MoralesC. E. AalsethF. T. Avignone IIIR. L. BrodzinskiS. CebrianE. GarciaD. GonzalezW. K. HensleyH. S. MileyJ. MoralesA. Ortiz de Solorzano  +5
The Canfranc dark matter search operates two germanium detectors. The 234 g COSME detector, with a 2.5 keV threshold, sets a 95% C.L. limit on the axion–photon coupling $g < 2.8 \times 10^{-9}$ GeV$^{-1}$ from 73 kg·days of data via Primakoff conversion and Bragg scattering. Its WIMP search improves exclusion limits for low-mass WIMPs. The 2 kg ⁷⁶Ge IGEX detector (4 keV threshold) improves spin-independent WIMP–nucleon exclusion limits for masses 30–100 GeV, the region highlighted by DAMA.
arXivarXiv · · November 27, 2000
0
New constraints on WIMPs from the Canfranc IGEX dark matter search
A. MoralesC.E. AalsethF.T. Avignone IIIR. L. BrodzinskiS. CebrianE. GarciaD. GonzalezW. K. HensleyI. G. IrastorzaI. V. KirpichnikovA. A. KlimenkoH. S. Miley  +13
Using an enriched germanium detector originally built for double-beta decay, the IGEX Collaboration set new constraints on the spin-independent WIMP-nucleon cross section. A 30-day exposure with a ~4 keV threshold yielded an exclusion plot that improves upon limits from other germanium experiments in the ~50 GeV DAMA region, and suggests that a modest background reduction below 10 keV together with a 1 kg-year exposure could test that region.
arXivarXiv · · February 21, 2000
0
Frequent collaborators
H.S. Miley (10)
S. Cebrian (7)
F.T. Avignone III (7)
H. S. Miley (7)
J. Morales (7)
A. Morales (7)
P.S. Barbeau (6)
J.I. Collar (6)
J.E. Fast (6)
T.W. Hossbach (6)
A. Knecht (6)
M.G. Marino (6)