MCP
CE

C. Enss

27 papers in the library

Papers

27
Improved limit on neutrinoless double beta decay of 100^{100}Mo from AMoRE-I
A. AgrawalV.V. Alenkov…C. Enss
The AMoRE-I experiment searched for neutrinoless double beta decay of $^{100}$Mo using 18 scintillating molybdate crystals at milli-Kelvin temperatures. With 8.02 kg$\cdot$year exposure and a background rate of $0.025\pm0.002$ counts/keV/kg/year near the $Q$-value, no signal was observed. The collaboration set a new lower limit on the half-life $T^{0\nu}_{1/2}>2.9\times10^{24}$ yr (90% CL) and constrained the effective Majorana mass $m_{\beta\beta}<(210-610)$ meV depending on nuclear models.
arXivarXiv · · July 8, 2024
0
Background study of the AMoRE-pilot experiment
A. AgrawalV.V. Alenkov…C. Enss
The AMoRE-pilot experiment searched for neutrinoless double beta decay ($0\nu\beta\beta$) of $^{100}$Mo using $\sim$1.9 kg of CaMoO$_4$ crystals at Yangyang Underground Laboratory (2015–2018). By comparing measured $\beta/\gamma$ spectra with Monte Carlo simulations across three configurations, the study identified background sources and guided detector upgrades, including improved neutron shielding. The analysis set a lower limit on the $0\nu\beta\beta$ half-life of $^{100}$Mo at $T_{1/2}^{0\nu} \ge 3.0\times 10^{23}$ years (90% CL), based on measured background and its modeling.
arXivarXiv · · January 15, 2024
0
16
Metallic magnetic calorimeter arrays for the first phase of the ECHo experiment
F. MantegazziniA. BarthH. DorrerCh. E. DüllmannC. EnssA. FleischmannR. HammannS. KempfT. KieckN. KovacC. VelteM. Wegner  +3
For the first phase of the ECHo experiment (ECHo-1k), a 72-pixel metallic magnetic calorimeter array was developed to measure the $^{163}$Ho electron capture spectrum for neutrino mass determination. Each pixel is designed for 100% stopping power of the capture radiation and an energy resolution below 10 eV FWHM. Two detector chips, with $^{163}$Ho implanted in gold and silver respectively, achieved average activities of 0.81 Bq and 0.71 Bq per pixel and average energy resolutions of 6.07 eV and 5.55 eV FWHM, meeting the ECHo-1k requirements.
arXivarXiv · · November 18, 2021
0
Online Demodulation and Trigger for Flux-ramp Modulated SQUID Signals
N. KarcherT. MuscheidT. WolberD. RichterC. EnssS. KempfO. Sander
This paper presents an FPGA-based implementation for online demodulation of flux-ramp modulated SQUID signals, targeting cryogenic microcalorimeter readout. The system processes 32 channels at up to 500 MHz clock frequency, integrating run-time demodulation and an event trigger with a configurable buffer. Trigger loss rates are theoretically characterized as a function of buffer size. The modules are validated using magnetic microcalorimeter data from an Iron-55 source read by a microwave SQUID multiplexer, demonstrating correct functionality and data reduction capability.
arXivarXiv · · October 22, 2021
0
First Results from the AMoRE-Pilot neutrinoless double beta decay experiment
V. AlenkovH. W. Bae…C. Enss
The AMoRE-Pilot experiment searches for neutrinoless double beta decay of $^{100}$Mo using six $^{48\text{depl}}$Ca$^{100}$MoO$_4$ crystals (1.9 kg total) with dual heat and light readout at milli-Kelvin temperatures in the Yangyang underground laboratory. With a 111 kg·d live exposure, no signal is observed, setting a half-life limit of $T^{0\nu}_{1/2} > 9.5\times10^{22}$ y at 90% C.L., corresponding to an effective Majorana neutrino mass limit $\langle m_{\beta\beta}\rangle \le (1.2-2.1)$ eV.
arXivarXiv · · March 22, 2019
0
154
Development of 100^{100}Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
E. ArmengaudC. Augier…C. Enss
This paper reports the development of $^{100}$Mo-enriched scintillating bolometers for the CUPID neutrinoless double-beta decay search. The detectors achieve 4–6 keV FWHM energy resolution near the 3034 keV $Q$-value, >8$\sigma$ rejection of $\alpha$-induced background above 2.6 MeV, and crystal radiopurity <10 $\mu$Bq/kg for $^{232}$Th and $^{226}$Ra. Using only 10 kg$\times$d exposure, the two-neutrino double-beta decay half-life of $^{100}$Mo was measured with the highest accuracy to date: $T_{1/2}=[6.90\pm0.15(\text{stat.})\pm0.37(\text{syst.})]\times10^{18}$ yr. Lithium molybdate was selected for the CUPID-0/Mo demonstrator.
arXivarXiv · · April 6, 2017
0
Direct Measurement of the Mass Difference of Ho163 and Dy163 Solves the Q-Value Puzzle for the Neutrino Mass Determination
S. EliseevK. BlaumM. BlockS. ChenmarevH. DorrerCh.E. DuellmannC. EnssP.E. FilianinL. GastaldoM. GoncharovU. KoesterF. Lautenschlaeger  +5
This paper reports a direct Penning-trap mass spectrometry measurement of the atomic mass difference between $^{163}$Ho and $^{163}$Dy using the SHIPTRAP apparatus with the phase imaging ion cyclotron resonance technique. The resulting mass difference of $2833(30_{\text{stat}})(15_{\text{sys}})\,\text{eV}/c^2$ shifts the 2012 Atomic Mass Evaluation value by more than $7\sigma$, resolving long-standing discrepancies in the $Q$ value of the electron capture in $^{163}$Ho. This new $Q$ value enables the ECHo experiment to reach a statistical sensitivity to the neutrino mass below $10\,\text{eV}$ in its first phase, more than an order of magnitude improvement over the current upper limit.
arXivarXiv · · April 14, 2016
0
A White Paper on keV Sterile Neutrino Dark Matter
R. AdhikariM. Agostini…C. Enss
This white paper reviews keV-scale sterile neutrinos as a Dark Matter candidate, synthesizing contributions from cosmology, astrophysics, nuclear, and particle physics. It examines the motivation from tensions in cold Dark Matter scenarios, critically summarizes observational and experimental constraints, and discusses the potentially positive X-ray signal. The paper also reviews particle physics models that generate keV-scale sterile neutrinos beyond the Standard Model, and surveys current and future search strategies, including their experimental challenges and discovery prospects.
arXivarXiv · · February 15, 2016
0
860
LUMINEU: a search for neutrinoless double beta decay based on ZnMoO4_4 scintillating bolometers
E.ArmengaudQ.Arnaud…C.Enss
LUMINEU uses ZnMoO$_4$ scintillating bolometers enriched in $^{100}$Mo to search for neutrinoless double beta decay. The detectors measure both the light and heat from particle interactions, providing high energy resolution and background discrimination. Aboveground and underground tests with natural and enriched crystals show that energy resolution, $\alpha/\beta$ discrimination, and radioactive contamination meet specifications. Simulations indicate that zero background near 3 MeV can be achieved with hundreds of kg$\times$years of exposure, supporting future experiments targeting the inverted neutrino mass hierarchy.
arXivarXiv · · January 19, 2016
0
13
Proceedings of the third French-Ukrainian workshop on the instrumentation developments for HEP
F. AlessioS.Ya. Barsuk…C. Enss
This volume reports the proceedings of the third French-Ukrainian workshop on instrumentation for high-energy physics, held at LAL, Orsay in October 2015 under the IDEATE International Associated Laboratory. The collected papers cover joint developments and new proposals in accelerator and beam monitoring, detector development, large-scale high-energy and astroparticle physics projects, and medical applications.
arXivarXiv · · December 23, 2015
0
0
Technical Design Report for the AMoRE 0νββ0νββ Decay Search Experiment
V. AlenkovP. Aryal…C. Enss
The AMoRE experiment searches for neutrinoless double-beta decay of $^{100}$Mo using cryogenic $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals. The high $Q$-value and nuclear matrix element of $^{100}$Mo, combined with the bright scintillation of calcium molybdate, enable discrimination of signal from alpha and two-neutrino backgrounds. With a 200 kg crystal array operating for three years, the experiment aims to reach an effective Majorana neutrino mass sensitivity of 20–50 meV, covering the inverted mass hierarchy.
arXivarXiv · · December 18, 2015
0
64
Cryogenic micro-calorimeters for mass spectrometric identification of neutral molecules and molecular fragments
O. NovotnýS. AllgeierC. EnssA. FleischmannL. GamerD. HengstlerS. KempfC. KrantzA. PabingerC. PiesD. W. SavinD. Schwalm  +1
This paper demonstrates that magnetic micro-calorimeters (MMCs) can identify neutral molecules and fragments by calorimetric mass spectrometry. For atomic projectiles with $E\approx13$ to 150 keV, absolute energy resolutions down to $\Delta E \approx 120$ eV and relative resolutions down to $\Delta E/E\approx10^{-3}$ are achieved. For molecular projectiles up to mass 56 u, the energy-response function is modeled, showing backscattering as the dominant energy-spread source, which is mitigated by a detector absorber coating. This work supports neutral-particle mass measurements in gas-phase collision reactions.
arXivarXiv · · May 27, 2015
0
Scintillating bolometers based on ZnMoO4_4 and Zn100^{100}MoO4_4 crystals to search for 0νν2ββ decay of 100^{100}Mo (LUMINEU project): first tests at the Modane Underground Laboratory
D.V. PodaE. Armengaud…C. Enss
The LUMINEU project develops scintillating bolometers based on ZnMoO$_4$ crystals to search for $0\nu2\beta$ decay of $^{100}$Mo. Using a low-thermal-gradient Czochralski technique, a Zn$^{100}$MoO$_4$ crystal from enriched $^{100}$Mo was produced for the first time. Initial tests of the detectors at the Modane Underground Laboratory demonstrate high detection performance, laying the groundwork for large-scale experiments targeting the inverted neutrino mass hierarchy.
arXivarXiv · · February 4, 2015
0
First Calorimetric Measurement of OI-line in the Electron Capture Spectrum of 163^{163}Ho
P. C.-O. RanitzschC. HasselM. WegnerS. KempfA. FleischmannC. EnssL. GastaldoA. HerlertK. Johnston
The paper reports the first calorimetric measurement of the OI-line (peak energy 48 eV) from the atomic de-excitation of 163Dy following electron capture from the 5s shell of 163Ho. The measurement, performed with low-temperature metallic magnetic calorimeters, demonstrates that the 163Ho calorimetric spectrum can be measured with high precision and that its parameters can be extracted from data. This result supports the ECHo experiment, which aims for sub-eV electron neutrino mass sensitivity via high-precision, high-statistics calorimetric measurement of the 163Ho spectrum.
arXivarXiv · · August 30, 2014
0
Specific heat of K071Na0.29Fe2As2 at very low temperatures
A. ReifenbergerM. HempelP. VogtS. AswarthamM. Abdel-HafiezV. GrinenkoS. WurmehlS.-L. DrechslerA. FleischmannC. EnssR. Klingeler
The present specific-heat measurements on a K0.71Na0.29Fe2As2 single crystal down to 0.02 K reveal a large T² contribution, providing evidence for d-wave order parameter symmetry in the superconducting state. To improve such measurements, the authors propose a calorimeter design using a paramagnetic temperature sensor, which is expected to achieve a temperature resolution of ΔT ≈ 0.1 μK and an addenda heat capacity below 200 pJ/K at T < 100 mK.
arXivarXiv · · May 11, 2014
0
Purification of molybdenum oxide, growth and characterization of medium size zinc molybdate crystals for the LUMINEU program
V.N. ShlegelL. Berge…C. Enss
The LUMINEU program seeks to detect neutrinoless double beta decay of $^{100}$Mo using radiopure ZnMoO$_4$ scintillating bolometers. This paper reports a purification method for molybdenum oxide that combines double sublimation (with zinc molybdate) and recrystallization in aqueous solutions (using zinc molybdate as a collector). The resulting compound enabled growth of ZnMoO$_4$ crystals up to 1.5 kg by the low-thermal-gradient Czochralski technique, whose optical, luminescent, diamagnetic, thermal, and bolometric properties were tested.
arXivarXiv · · December 12, 2013
0
20
The Electron Capture 163^{163}Ho Experiment ECHo: an overview
L. GastaldoK. BlaumA. DoerrCh. E. DuellmannK. EberhardtS. EliseevC. EnssAmand FaesslerA. FleischmannS. KempfM. KrivoruchenkoS. Lahiri  +6
The ECHo experiment aims to determine the electron neutrino mass in the sub-eV range by calorimetrically measuring the energy spectrum following the electron capture of $^{163}$Ho. Essential aspects to reach this sensitivity include detector optimization with metallic magnetic calorimeters, multiplexed readout, $^{163}$Ho source production, and precise parameterization of the capture spectrum, particularly the $Q_{\mathrm{EC}}$ value. Preliminary results from a single-channel prototype and a 64-pixel chip with integrated micro-wave SQUID multiplexer already allow eV-scale investigation.
arXivarXiv · · September 20, 2013
0
Multiplexed readout of MMC detector arrays using non-hysteretic rf-SQUIDs
S. KempfM. WegnerL. GastaldoA. FleischmannC. Enss
This paper presents the design and expected performance of a 64-pixel metallic magnetic calorimeter (MMC) array integrated with a microwave SQUID multiplexer for frequency-domain readout. The multiplexer uses non-hysteretic rf-SQUIDs to transduce detector signals into frequency shifts of high-$Q$ resonators, which are monitored via standard microwave techniques. First experimental data characterize dc-SQUIDs with a virtually identical washer design, supporting the multiplexer's feasibility for future large MMC arrays.
arXivarXiv · · September 19, 2013
0
Prospects for measuring the 229Th isomer energy using a metallic magnetic microcalorimeter
G. A. KazakovV. SchauerJ. SchwestkaS. P. StellmerJ. H. SterbaA. FleischmannL. GastaldoA. PabingerC. EnssT. Schumm
This paper proposes using metallic magnetic microcalorimeters with a few eV resolution to directly measure the 229Th isomer energy, replacing the current indirect value of 7.8±0.5 eV derived from a 26 eV resolution instrument. The key idea is to resolve the 29.18 keV doublet in the γ-spectrum of 233U α-decay, which corresponds to transitions into the ground and isomer states, enabling a model-independent measurement with improved accuracy. The study analyzes how the attainable precision depends on instrumental resolution, signal rate, and background count rate.
arXivarXiv · · June 13, 2013
0
The Electron Capture 163^{163}Ho Experiment ECHo
K. BlaumA. DoerrC. E. DuellmannK. EberhardtS. EliseevC. EnssA. FaesslerA. FleischmannL. GastaldoS. KempfM. KrivoruchenkoS. Lahiri  +6
The ECHo experiment determines the electron neutrino mass by measuring the calorimetric energy spectrum of the electron capture process of $^{163}$Ho. Low-temperature magnetic calorimeter arrays provide the high precision and high statistics needed to reach sub-eV sensitivity. Preliminary results from single-channel detector prototypes are reported, and the collaborating groups present their ongoing developments.
arXivarXiv · · June 11, 2013
0
Evidence of d-wave Superconductivity in K_(1-x)Na_xFe_2As_2 (x = 0, 0.1) Single Crystals from Low-Temperature Specific Heat Measurements
M. Abdel-HafiezV. Grinenko…C. Enss
Low-temperature specific heat measurements on K_{1-x}Na_xFe_2As_2 (x = 0, 0.1) single crystals reveal a large T^2 term with coefficient α_sc ~ 30 mJ/mol K^3 and a square-root field dependence. These two features constitute evidence for d-wave superconductivity on nearly all Fermi surface sheets, with an average gap amplitude Δ_0 between 0.4 and 0.8 meV. The observed Δ_0 and T_c align with Eliashberg theory calculations based on spin-fluctuation mediated pairing in the intermediate coupling regime.
arXivarXiv · · January 22, 2013
0
2
Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted 163^{163}Ho ions
L. GastaldoP. RanitzschF. von SeggernJ.-P. PorstS. SchäferC. PiesS. KempfT. WolfA. FleischmannC. EnssA. HerlertK. Johnston
This paper reports the first characterization of fully micro-fabricated low-temperature metallic magnetic calorimeters (MMCs) after the ion-implantation of radioactive $^{163}$Ho into their gold absorbers. The implantation was performed at ISOLDE-CERN. The MMCs with implanted $^{163}$Ho are compared to unimplanted detectors, showing that the implantation dose used does not compromise detector performance. An optimized detector design for future $^{163}$Ho experiments is also presented.
arXivarXiv · · June 25, 2012
0
The Microcalorimeter Arrays for a Rhenium Experiment (MARE): a next-generation calorimetric neutrino mass experiment
A. MonfardiniC. ArnaboldiC. BrofferioS. CapelliF. CapozziO. CremonesiC. EnssE. FioriniA. FleischmannL. FoggettaG. GallinaroL. Gastaldo  +20
The Microcalorimeter Arrays for a Rhenium Experiment (MARE) project aims to directly measure the neutrino mass with a sensitivity of about $0.2\,\mathrm{eV}/c^2$. It builds on the experience of previous experiments and combines the technical expertise of multiple groups. MARE is presented as a complementary effort to KATRIN, addressing the absolute neutrino mass scale not determined by oscillation experiments.
arXivarXiv · · September 26, 2005
0
83
Magnetic Field Dependent Coherent Polarization Echoes in Glasses
S. LudwigP. NagelS. HunklingerC. Enss
This paper reports polarization echo experiments on insulating glasses at very low temperatures, which reveal a strong magnetic field dependence of coherent properties of atomic tunneling systems. The results support a model in which nuclear quadrupoles are the key origin of the observed magnetic field effects on dielectric properties, a phenomenon that has been puzzling since its discovery.
arXivarXiv · · October 10, 2002
0
Evidence for Magnetic Field Induced Changes of the Phase of Tunneling States: Spontaneous Echoes in (KBr)1−x_{1-x}(KCN)x_x in Magnetic Fields
C. EnssS. Ludwig
The paper reports that magnetic fields alter the phase of atomic tunneling states in a crystalline host. Two-pulse echo experiments on (KBr)$_{1-x}$(KCN)$_x$ with 7.5% CN$^-$ show a strong, non-monotonic dependence of the echo amplitude on fields up to 230 mT. This direct evidence of field-induced phase changes in tunneling systems, previously observed only in glasses, is surprising for a crystalline system and may explain the magnetic-field dependence of low-temperature dielectric properties.
arXivarXiv · · April 16, 2002
0
Influence of Random Internal Fields on the Tunneling of OH Defects in NaCl Crystals
M. ThesenR. KühnC. EnssS. Ludwig
The paper investigates the dielectric susceptibility of hydroxyl ions (OH⁻) in NaCl crystals at very low concentrations of less than 30 ppm, where defect interactions are negligible. The observed temperature dependence deviates from the behavior expected for isolated defects in a symmetric environment. The authors propose that random internal strains from host-crystal imperfections cause these deviations. They present experimental data and a microscopic theoretical model that quantitatively accounts for the influence of these random internal fields on the tunneling of OH⁻ defects.
arXivarXiv · · October 10, 2001
0
1
Evidence for a Second Order Phase Transition in Glasses at Very Low Temperatures -- A Macroscopic Quantum State of Tunneling Systems
P. StrehlowC. EnssS. Hunklinger
Dielectric measurements on a BaO-Al$_2$O$_3$-SiO$_2$ glass show a phase transition at 5.84 mK. Below this temperature, magnetic fields of about 10 $\mu$T significantly alter the dielectric constant, whereas above 10 mK the glass is insensitive to fields up to 20 T. This behavior is interpreted as a second-order phase transition into a phase where many tunneling systems undergo coherent motion, forming a macroscopic quantum state.
arXivarXiv · · December 31, 1997
0
Frequent collaborators
A. Fleischmann (19)
L. Gastaldo (18)
S. Kempf (11)
R.S. Boiko (7)
F.A. Danevich (7)
V.V. Kobychev (7)
V.I. Tretyak (7)
E.P. Makarov (6)
V.N. Shlegel (6)
V. Kornoukhov (5)
M. Wegner (5)
A. Giuliani (5)