MCP
CM

C. Mandache

6 papers in the library

Papers

6
Laser locking to the 199Hg clock transition with 5.4x10^(-15)/sqrt(tau) fractional frequency instability
J. J. McFerranD. V. MagalhaesC. MandacheJ. MilloW. ZhangY. Le CoqG. SantarelliS. Bize
By trapping Hg atoms in an optical lattice in the Lamb-Dicke regime, the authors obtain a sub-15 Hz spectral line at 265.6 nm and lock an ultrastable laser to this clock transition. The locked laser achieves a fractional frequency instability of $5.4\times 10^{-15}/\sqrt{\tau}$ for $\tau\leq 400$ s. The probe light is derived from a 1062.6 nm fiber laser stabilized to a cavity with a mean drift of $-6.0\times 10^{-17}$ s$^{-1}$ over five months.
arXivarXiv · · May 18, 2012
0
An Ultra-Stable Referenced Interrogation System in the Deep Ultraviolet for a Mercury Optical Lattice Clock
S.T. DawkinsR. ChicireanuM. PetersenJ. MilloD.V. MagalhãesC. MandacheY. Le CoqS. Bize
The paper presents an ultra-stable deep-UV interrogation source for a mercury optical lattice clock. A Fabry-Pérot cavity with fused-silica mirrors (low thermal noise) stabilizes a 1062.6 nm fiber laser. The signal is referenced to primary frequency standards via an optical frequency comb, achieving fractional stability at the 1E-15 level. After two frequency-doubling stages, several milliwatts at 265.6 nm are obtained for clock interrogation.
arXivarXiv · · March 22, 2010
0
Ultrastable lasers based on vibration insensitive cavities
J. MilloD. V. MagalhaesC. MandacheY. Le CoqE. M. L. EnglishP. G. WestergaardJ. LodewyckS. BizeP. LemondeG. Santarelli
The paper presents two ultrastable lasers built from vibration-insensitive cavities, one with vertical and one with horizontal optical axis. Using fused silica mirror substrates reduces the thermal noise limit, improving frequency stability. Vibration sensitivity in each spatial direction is at or below $1.5 \times 10^{-11}$ per $\text{m} \cdot \text{s}^{-2}$, and the design eliminates fine-tuning of support points. One laser achieves a relative frequency stability better than $5.6 \times 10^{-16}$ at 1 second, the best reported for this cavity length.
arXivarXiv · · January 29, 2009
0
312
Doppler-free spectroscopy of the 1S0-3P0 optical clock transition in laser-cooled fermionic isotopes of neutral mercury
M. PetersenR. ChicireanuS.T. DawkinsD.V. MagalhãesC. MandacheY. LecoqA. ClaironS. Bize
We report the first direct laser spectroscopy of the $^1$S$_0$-$^3$P$_0$ optical clock transition at 265.6 nm in laser-cooled fermionic isotopes of neutral mercury. The Doppler-free recoil doublet is resolved by measuring trap depletion from excited $^3$P$_0$ atoms. Absolute frequencies are measured as $1128575290808 \pm 5.6$ kHz for $^{199}$Hg and $1128569561140 \pm 5.3$ kHz for $^{201}$Hg, improving precision by over four orders of magnitude over prior indirect determinations. Mercury's low blackbody radiation sensitivity makes it a promising candidate for optical lattice clocks.
arXivarXiv · · July 22, 2008
0
A Search for Variations of Fundamental Constants using Atomic Fountain Clocks
H. MarionF. Pereira Dos SantosM. AbgrallS. ZhangY. SortaisS. BizeI. MaksimovicD. CalonicoJ. GruenertC. MandacheP. LemondeG. Santarelli  +3
Over five years, the authors compared the hyperfine frequencies of laser-cooled 133Cs and 87Rb atoms using atomic fountain clocks at ~10^{-15} accuracy. They set an upper bound on fractional time variation of the frequency ratio: (d/dt)ln(ν_Rb/ν_Cs) = (0.2 ± 7.0)×10^{-16} yr^{-1} (1σ). This also constrains variation of (μ_Rb/μ_Cs)·α^{-0.44}, involving nuclear magnetic moments and the fine-structure constant.
arXivarXiv · · December 31, 2002
0
133Cs87Rb Laser Cooled Dual Fountain
D. CalonicoY. SortaisS. BizeH. MarionC. MandacheC. SalomonG. SantarelliA. Clairon
This paper describes a dual fountain that simultaneously operates with both $^{87}$Rb and $^{133}$Cs atoms within the same vacuum structure at BNM-SYRTE, Paris. Although only the Cs fountain is currently running, the Rb section is complete and will soon be operational. The primary goal is to improve fountain frequency standards and, by comparing the two species, to test for a time variation of the fine structure constant $\alpha$ at the $10^{-16}$ level.
arXivarXiv · · December 10, 2002
0
Frequent collaborators
S. Bize (6)
G. Santarelli (4)
J. Millo (3)
Y. Le Coq (3)
A. Clairon (3)
D. V. Magalhaes (2)
S.T. Dawkins (2)
R. Chicireanu (2)
M. Petersen (2)
D.V. Magalhães (2)
P. Lemonde (2)
H. Marion (2)