MCP
CS

C. Sozzi

9 papers in the library

Papers

9
New plasma regimes with small ELMs and high confinement at the Joint European Torus
J. GarciaE. de la Luna…C. Sozzi
On the Joint European Torus tokamak, new plasma regimes combining high confinement, low core impurity accumulation, and small edge localized mode (ELM) perturbations were achieved near ITER conditions. Optimized particle fueling triggered a self-organized state with increased rotation and ion temperature and decreased edge density. Core–edge interplay reduced turbulence and produced outward impurity convection, offering an alternative to standard plasmas for metal-walled tokamaks like ITER.
arXivarXiv · · March 3, 2021
0
Planck Early Results: The Planck mission
Planck CollaborationP. A. R. Ade…C. Sozzi
The Planck satellite, launched by ESA on 14 May 2009, has been surveying the sky continuously since 13 August 2009 with performance meeting expectations. This paper provides an overview of Planck's first year of operations and key satellite performance aspects, as part of a package accompanying the Early Release Compact Source Catalogue—the first public Planck data product.
arXivarXiv · · January 11, 2011
0
1k+
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
A. MennellaM. Bersanelli…C. Sozzi
This paper assesses the in-flight performance of Planck's Low Frequency Instrument (LFI) after one year of operation. It presents the main optical parameters, photometric calibration, white noise sensitivity, and noise properties, along with a preliminary evaluation of systematic effects. The methods used to derive these parameters from flight data are outlined, and the results confirm pre-launch ground assessments.
arXivarXiv · · January 11, 2011
0
234
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
F. VillaL. Terenzi…C. Sozzi
This paper reports the pre-launch calibration of the eleven radiometer subsystems (RCAs) aboard the Planck Low Frequency Instrument. Each RCA, a pseudo-correlation receiver, was tested in a cryogenic environment with its front-end at 20 K and back-end at 300 K, using a variable-temperature blackbody load. Key parameters—noise temperature, gain, 1/f noise, spectral response, and thermal susceptibility—were measured. These results provide essential inputs for Planck-LFI data analysis.
arXivarXiv · · May 14, 2010
0
28
Planck LFI flight model feed horns
F. VillaO. D'ArcangeloM. PecoraL. FiginiR. NestiA. SimonettoC. SozziM. SandriP. BattagliaP. GuzziM. BersanelliR.C. Butler  +1
This paper describes the design, manufacturing, and testing of the 11 corrugated feed horns that optically interface the Planck Low Frequency Instrument (LFI) with the ESA Planck telescope. The horns were designed to optimize the LFI optical interfaces while satisfying the stringent mechanical requirements of the Planck focal plane layout. All eleven flight-model units were successfully tested and integrated with the Ortho Mode Transducers.
arXivarXiv · · January 26, 2010
0
The PLANCK LFI flight model ortho-mode transducers
O. D'ArcangeloA. Simonetto…C. Sozzi
The Planck LFI uses 22 ultra-sensitive pseudocorrelation radiometers at 30, 44, and 70 GHz to measure CMB anisotropy and polarization. Intrinsic polarization sensitivity is achieved by Ortho-Mode Transducers (OMTs) that separate incoming radiation into two linear orthogonal components. A set of 11 flight-model OMTs (2 at 30 GHz, 3 at 44 GHz, 6 at 70 GHz) was developed through an Elegant Bread Board and Qualification Model campaign. The paper reports that all flight units were accepted and their electromagnetic performance is at least marginally compliant with requirements, with mechanical qualification passed after a rework.
arXivarXiv · · January 26, 2010
0
16
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
A. MennellaM. Bersanelli…C. Sozzi
Based on ground cryogenic tests, the Planck Low Frequency Instrument (LFI) achieves excellent $1/f$ stability and rejection of systematic effects, with measured noise performance making it the most sensitive instrument of its kind. These calibration parameters represent the best pre-launch characterization of the LFI's scientific performance and will be updated during flight operations.
arXivarXiv · · January 25, 2010
0
55
Planck pre-launch status: Design and description of the Low Frequency Instrument
M. BersanelliN. Mandolesi…C. Sozzi
This paper describes the design and scientific requirements of the Planck Low Frequency Instrument (LFI), a 20-K cryogenic array of differential microwave radiometers using Indium Phosphide HEMT amplifiers and 4-K blackbody reference loads. LFI will map the full sky in intensity and polarization at 30, 44, and 70 GHz to complement the higher-frequency HFI instrument in precision imaging of the cosmic microwave background.
arXivarXiv · · January 19, 2010
0
308
Planck pre-launch status: the Planck-LFI programme
N. MandolesiM. Bersanelli…C. Sozzi
The Planck Low Frequency Instrument (LFI) programme is designed to produce high-precision maps of the microwave sky at 27–77 GHz, targeting the cosmic microwave background (CMB) and foregrounds. The instrument has been developed and tested, with a data processing centre (DPC) capable of reducing flight data into calibrated time-ordered data, sky maps (temperature and polarization), component emission maps, and source catalogues. Tests on the flight model demonstrate excellent performance, and the pipeline's main steps are verified. After launch, three months of commissioning and calibration will precede the operational phase.
arXivarXiv · · January 15, 2010
0
186
Frequent collaborators
M. Bersanelli (8)
O. D'Arcangelo (8)
N. Mandolesi (8)
A. Simonetto (8)
M. Sandri (7)
F. Villa (7)
B. Cappellini (6)
F. Cuttaia (6)
E. Franceschi (6)
A. Gregorio (6)
R. Leonardi (6)
D. Maino (6)