High-power X-Point Target divertor experiments on the TCV tokamak
K. LeeM. CarpitaC. TheilerM. ZuritaO. FévrierA. MeleR. I. MorganF. PastoreH. ReimerdesK. VerhaeghM. WinkelD. Brida  +13
High-power (2.5 MW) TCV L-mode experiments test the X-Point Target (XPT) divertor under Lengyel detachment scaling values representative of reactors such as SPARC, ITER and ARC, and establish XPT as a potential power-exhaust solution. Relative to a single-null divertor, XPT cuts the peak outer-target heat flux by 40–60% and achieves nitrogen-seeded detachment where the SN cannot detach, though detachment evolves asymmetrically across the multiple XPT outer strike points. Sensitivities of peak heat fluxes and impurity emission fronts to the X-point separation $\text{d}R_{\text{u},X2}$ weaken with stronger seeding, and field-reversal experiments show that topology-inherent $E\times B$ drifts redistribute density and impurity radiation, largely confirming recent SOLPS-ITER expectations. The results are framed through SOL splitting, connection-length peaking, $E\times B$ drifts and vessel geometry.
arXivarXiv · · November 9, 2026
0
High-power TCV scenario for conventional and alternative divertor studies
K. LeeC. TheilerM. CarpitaM. ZuritaP. SintreO. FévrierF. PastoreH. ReimerdesK. VerhaeghM. WinkelD. BridaB. Y. K. Brown  +11
This paper introduces a high-power scenario on the TCV tokamak that enables the study of alternative divertor configurations under reactor-relevant boundary conditions. With 2.5 MW of electron cyclotron resonance heating fully absorbed in a ~1 m³ plasma, stationary parallel heat fluxes of up to 100 MW m⁻² are measured at the divertor target—an order of magnitude above previous TCV studies. The scenario's SOL collisionality and Lengyel detachment metric match values projected for future reactors (SPARC, ITER, ARC).
arXivarXiv · · August 19, 2026
0
0
Synthetic Diagnostic Modeling for Plasma Tomography: Geometry Matrix Computation Methods and Impact of Model Accuracy
D. HammG. PartesottiC. TheilerU. Sheikh
The paper presents a voxel-to-detector (V2D) method for computing physically accurate volume-of-sight (VoS) geometry matrices for plasma tomography, which avoid the systematic errors of the commonly used line-of-sight (LoS) approximation. Applied to the TCV tokamak, the VoS model is shown to improve reconstruction accuracy and precision over the LoS model, though the simpler model does not introduce significant bias for estimated total, core, divertor, and main chamber radiated powers. The V2D results are validated by agreement with an independent ray-tracing implementation.
arXivarXiv · · August 4, 2026
0
0
Detachment dynamics and disturbance rejection in the TCV X-Point Target divertor
M. WinkelK. VerhaeghB. KoolK. LeeM. CarpitaD. BridaG. DerksO. FévrierR. I. MorganO. PanA. PerekC. Theiler  +4
On TCV, the detachment dynamics and disturbance rejection of the X-Point Target (XPT) divertor, which has a secondary X-point in the divertor leg, were compared with a long-legged single-null (SN) divertor using multi-sine perturbations and the CIII emission front position as a proxy for the detached state. For D$_2$ fuelling at 4-31 Hz, the front-response gain at the secondary X-point is at least a factor of 3 lower than upstream, where it resembles the SN, so the reduced detachment sensitivity seen quasi-statically extends to control-relevant timescales. Under N$_2$ seeding and ECRH perturbations the XPT front stays nearly stationary while the SN responds strongly, though complex SOL profiles near the secondary X-point mean this may not imply rejection for the detached state as a whole; the effect could passively buffer disturbances and simplify exhaust control.
arXivarXiv · · June 22, 2026
0
0
Real-time Tomography-based Bayesian Inference from TCV Bolometry Data
D. HammC. TheilerL. SimonsB. P. DuvalU. Sheikhthe TCV team
This work presents a real-time tomography-based Bayesian method for estimating radiated power from user-defined plasma regions in the TCV tokamak using bolometer data. The method computes cheap linear combinations of measurements with pre-optimized coefficients, bypassing the need for training on synthetic profiles. It is equivalent to traditional tomographic estimates under suitable conditions, and its application to heterogeneous TCV discharges demonstrates accurate real-time estimation of total, core, divertor, and main chamber radiated power. Robustness to faulty detectors is discussed, and open-source code is provided.
arXivarXiv · · March 12, 2026
0
0
Initial observations in X-point target divertor discharges on MAST-U
N. LonigroK. Verhaegh…C. Theiler
High-power H-mode experiments on MAST-U demonstrate the X-point-target (XPT) divertor, which combines a large strike-point radius (as in the Super-X design) with an additional X-point near the separatrix in the outer divertor. The XPT broadens the electron density profile near the secondary X-point, enhancing plasma-neutral interactions and thereby increasing power and ion sinks while lowering target electron temperatures and heat fluxes. Preliminary evidence also suggests improved ELM buffering. The work shows how combining multiple divertor strategies can enhance exhaust performance for future reactors.
arXivarXiv · · January 29, 2026
0
1
Comparison of filament properties in real-size GBS simulations and experiments of TCV-X21
Y. WangC. WüthrichC. TheilerS. García HerrerosD. S. OliveiraD. ManciniT. GolfinopoulosP. RicciT. Bodythe TCV team
By extending the TCV-X21 dataset with Gas Puff Imaging (GPI) measurements and applying a synthetic GPI diagnostic to GBS fluid simulations, this work directly compares scrape-off layer filament properties in TCV tokamak experiments and simulations. Good agreement is found for poloidal and radial filament velocities, but simulations overestimate filament sizes and underestimate relative fluctuation levels. Filaments in the simulations are predominantly density perturbations, and the poloidal velocity direction agrees with the time-averaged $\boldsymbol{E}\times\boldsymbol{B}$ direction at the outboard midplane and X-point, but not in the divertor leg.
arXivarXiv · · December 5, 2025
0
3
Tomography for Plasma Imaging: a Unifying Framework for Bayesian Inference
D. HammC. TheilerM. SimeoniB. P. DuvalT. DebarreL. SimonsJ. R. Queralt
This paper unifies sparse-view tomographic plasma imaging under Bayesian inference. The likelihood models the measurement process, and the prior encodes assumed profile properties, together forming a posterior distribution. The authors show that many existing inversion methods are special cases of this framework. Efficient posterior sampling is achieved via a stochastic gradient flow algorithm, enabling credible reconstructions and uncertainty quantification, demonstrated on soft x-ray data from the TCV tokamak.
arXivarXiv · · June 25, 2025
0
4
Predictive power-sharing scaling law in double-null L-mode plasmas
K. LimP. RicciL. StengerB. De LuccaG. Durr-Legoupil-NicoudO. FévrierC. TheilerK. Verhaegh
This paper derives an analytical scaling law for the power-sharing asymmetry at the outer targets of L-mode double-null (DN) tokamak configurations. Using nonlinear, flux-driven, three-dimensional two-fluid simulations, the authors identify that the asymmetry is governed by the combined effects of diamagnetic drift, turbulence, and geometrical factors. The scaling law, based on these observations, captures the trends from nonlinear simulations and agrees with experimental data from TCV DN discharges.
arXivarXiv · · June 28, 2024
0
14
First 2D electron density measurements using Coherence Imaging Spectroscopy in the MAST-U Super-X divertor
N. LonigroR. DoyleJ. S. AllcockB. LipschultzK.VerhaeghC. BowmanD. BridaJ. HarrisonO. MyatraS. SilburnC. TheilerT.A. Wijkamp  +2
This work presents the first 2D electron density measurements in the MAST-U Super-X divertor using Coherence Imaging Spectroscopy. A non-linear inversion technique infers electron density and neutral temperature from multi-delay images of Balmer line broadening, separating Doppler and Stark components. Applied to simulated data, it achieves mean absolute errors of ~30%, consistent with uncertainty propagation. On experimental L-mode plasmas, it yields densities of 2–3 $10^{19}$ m$^{-3}$ and neutral temperatures of 0–2 eV, in reasonable agreement with other diagnostics.
arXivarXiv · · April 18, 2024
0
1
SPLEND1D, a reduced one-dimensional model to investigate the physics of plasma detachment
O. FévrierS. GornoC. TheilerM. CarpitaG. Durr-Legoupil-NicoudM. von Allmen
SPLEND1D is a fast 1D scrape-off layer model for studying divertor detachment. It self-consistently includes plasma dynamics, atomic physics, sources, sinks, and flows. The code is used to investigate power and momentum losses for parameters typical of the TCV tokamak, and to explore the model's hypotheses and free parameters, serving as a computationally efficient intermediate between analytical models and full 2D/3D simulations.
arXivarXiv · · February 7, 2024
0
Modelling of power exhaust in TCV positive and negative triangularity L-mode plasmas
E. TonelloF. MombelliO. FévrierG. AlbertiT. BolzonellaG. Durr-Legoupil-NicoudS. GornoH. ReimerdesC. TheilerN. VianelloM. PassoniTCV team  +1
SOLPS-ITER modelling of two TCV L-mode lower single null Ohmic discharges with opposite triangularity ($\delta \simeq \pm 0.3$) reproduces the experimental observation that negative triangularity (NT) plasmas are harder to detach than positive triangularity (PT) ones. Using the same anomalous diffusivity for particles and energy in both configurations, the simulations attribute this difference to dissimilar neutral particle transport and accumulation in the scrape-off layer, leading to different ionization sources and plasma fluxes. The outer target remains hotter in the NT case ($T_{e, NT} \gtrsim 5 \, \mathrm{eV}$).
arXivarXiv · · January 8, 2024
0
Validation of SOLPS-ITER Simulations against the TCV-X21 Reference Case
Y. WangC. ColandreaD. S. OliveiraC. TheilerH. ReimerdesT. BodyD. GalassiL. MartinelliK. LeeTCV team
This paper validates SOLPS-ITER simulations against the TCV-X21 reference case, adding five new observables (three deuterium Balmer lines and neutral pressure) to the dataset. Using a quantitative agreement metric combined with the conjugate gradient method, and alternatively a scan of particle and heat diffusion coefficients, the best agreement (10.4% improvement over the gradient method) was found with increased transport coefficients. The simulations show that ~65% of total ionization occurs in the scrape-off layer, motivating neutral inclusion in future turbulence simulations for improved agreement with experiment.
arXivarXiv · · October 26, 2023
0
11
Performance assessment of a tightly baffled, long-legged divertor configuration in TCV with SOLPS-ITER
G. SunH. ReimerdesC. TheilerB. P. DuvalM. CarpitaC. ColandreaO. FévrierTCV team
SOLPS-ITER simulations predict that a tightly baffled, long-legged divertor (TBLLD) configuration in TCV can improve power handling by factors of 2–3 over the current baffled divertor and up to 12 over the unbaffled configuration. This improvement stems from better neutral confinement and enhanced plasma–neutral interactions in the divertor region. Reducing the radial gap between the separatrix and the outer-leg side walls further increases both power handling and neutral confinement. For the TBLLD with the thinnest gap, the required upstream impurity concentration to achieve detachment with nitrogen seeding is reduced by up to 18% relative to wider gaps.
arXivarXiv · · March 16, 2023
0
Improved Heat and Particle Flux Mitigation in High Core Confinement, Baffled, Alternate Divertor Configurations in the TCV tokamak
Harshita RajC. TheilerA. ThorntonO. FevrierS. GornoF. BagnatoP. BlanchardC. ColandreaH. de OliveiraB.P. DuvalB. LabitA. Perek  +4
In the TCV tokamak, nitrogen-seeded detachment in advanced divertor configurations (X-divertor and X-point target) with baffles reduces inter-ELM particle and heat fluxes to the target by 95-98% of peak heat flux, while maintaining high core confinement in H-mode plasmas. This mitigation is a synergetic effect of the divertor geometry, baffling, and nitrogen seeding, demonstrating improved core-divertor compatibility compared to the standard divertor configuration.
arXivarXiv · · July 27, 2022
0
Impurity seeding for suppression of the near Scrape-Off Layer heat flux feature in tokamak limited plasmas
F. NespoliB. LabitI. FurnoC. TheilerU. SheikhC.K. TsuiJ.A. BoedoTCV team
The paper proposes impurity seeding to mitigate the near scrape-off layer (SOL) heat flux feature in inboard-limited tokamak plasmas, which otherwise causes excessive thermal loads on solid surfaces. Building on prior results, first experimental evidence from the TCV tokamak demonstrates successful suppression of this feature, offering a potential technique for protecting reactor components during start-up and ramp-down.
arXivarXiv · · December 4, 2017
0
9
Spectroscopic investigations of divertor detachment in TCV
K. VerhaeghB. LipschultzB.P. DuvalJ.R. HarrisonH. ReimerdesC. TheilerB. LabitR. MaurizioC. MariniF. NespoliU. SheikhC.K. Tsui  +4
This work investigates divertor detachment in the TCV tokamak using a new Divertor Spectroscopy System and Balmer line analysis. During density ramps, detachment is inferred from a drop in target ion current, coinciding with recombination-dominated Balmer $6\rightarrow2$ and $7\rightarrow2$ emission near the target. Unlike higher-density tokamaks, the peaks in recombination and density remain within a few cm poloidally of the target up to a Greenwald fraction of 0.7. Recombination at detachment onset is small compared to the target ion current, but at the highest densities total recombination reaches similar levels.
arXivarXiv · · July 15, 2016
0
73
Frequent collaborators
O. Février (7)
H. Reimerdes (7)
K. Verhaegh (6)
M. Carpita (5)
D. Brida (5)
G. Durr-Legoupil-Nicoud (5)
D. Hamm (5)
U. Sheikh (5)
TCV team (5)
K. Lee (4)
A. Perek (4)
Y. Wang (4)