CUORE Data Release for ML Applications: Pulse Shape Analysis Dataset
CUORE Collaboration
The CUORE experiment releases a public dataset of thermal pulses from its TeO$_2$ cryogenic calorimeters, stored as one-dimensional time series in HDF5 format. Each pulse is labeled for binary classification—single-pulse event versus pile-up event with two or more pulses—and includes normalization parameters and metadata. The dataset enables supervised learning benchmarks for pulse shape analysis and pile-up identification in rare-event searches.
arXivarXiv · · June 25, 2026
0
Reconstruction of cosmic-ray muon events with CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoA. ArmatolF. T. AvignoneO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. Biassoni  +109
By using the segmentation of the CUORE cryogenic detector array, a multi-objective optimization algorithm achieves in-situ 3D reconstruction of through-going cosmic-ray muons without time-of-flight estimation. The integral muon flux measured underground at the Laboratori Nazionali del Gran Sasso agrees with other experiments. This work is the first demonstration of 3D particle tracking with per-event angular determination in a millikelvin detector, critical for validating muon-related background in next-generation neutrinoless double-beta decay experiments.
arXivarXiv · · September 5, 2025
0
0
Exploring the keV-scale physics potential of CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoA. ArmatolF. T. AvignoneO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. Biassoni  +111
This paper reports the keV-scale analysis of the CUORE experiment using over 2 tonne yr of data. By applying stricter selection to optimize thresholds at 10 keV and 3 keV, the analysis achieves average baseline resolutions of 2.54 ± 0.14 keV and 1.18 ± 0.02 keV FWHM, respectively. The overall background is reduced by about an order of magnitude, reaching 2.06 ± 0.05 counts/(keV kg days) at 10 keV and 16 ± 2 counts/(keV kg days) at 3 keV. Near-threshold reconstruction efficiencies are evaluated for the first time, yielding 50 ± 2 % at 10 keV and 26 ± 4 % at 3 keV, demonstrating the scalability of tonne-scale cryogenic calorimeters for low-energy physics.
arXivarXiv · · May 29, 2025
0
5
Search for fractionally charged particles with CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. Branca  +108
The Cryogenic Underground Observatory for Rare Events (CUORE), a 988-crystal TeO$_2$ array operating below 20 mK, is used to search for fractionally charged particles (FCPs) with charges between $e/24$ and $e/5$. Using the first tonne-year of exposure, no significant excess of FCP candidate tracks is found, leading to the most stringent limits on the underground FCP flux in this charge range at 90% confidence level. This work demonstrates the sensitivity of tonne-scale sub-Kelvin detectors to exotic particle signatures.
arXivarXiv · · June 18, 2024
0
15
Data-driven background model for the CUORE experiment
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. Branca  +106
We present a data-driven background model for the CUORE experiment, built from a Bayesian fit to energy spectra across a broad range using 1038.4 kg yr of exposure. The model exploits detector granularity, exposure, and operational stability to resolve spatial and time-dependent backgrounds, achieving sensitivity to bulk activities as low as 10 nBq kg$^{-1}$ and surface activities as low as 0.1 nBq cm$^{-2}$. The extracted contamination levels are compared with prior radio-assay data, informing future background mitigation strategies for CUORE and the CUPID experiment.
arXivarXiv · · May 28, 2024
0
36
Constraints on Lepton Number Violation with the 2 tonne⋅\cdotyr CUORE Dataset
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. AvignoneO. AzzoliniG. BariF. BelliniG. BenatoM. BerettaM. BiassoniA. Branca  +106
The CUORE experiment searches for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te using a tonne-scale cryogenic calorimeter at milli-kelvin temperatures. With over 2 tonne$\cdot$year TeO$_2$ exposure, no evidence of $0\nu\beta\beta$ is found, yielding a lower limit on the half-life of $T_{1/2} > 3.5 \times 10^{25}$ years (90% C.I.). This result and the stable operation of nearly 1000 detectors demonstrate infrastructure for future searches.
arXivarXiv · · April 5, 2024
0
11
Search for Double-Beta Decay of 130Te\mathrm{^{130}Te} to the 0+0^+ States of 130Xe\mathrm{^{130}Xe} with CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. Biassoni A. BrancaC. BrofferioC. Bucci  +96
The CUORE experiment searches for neutrino-less double beta decay ($0\nu\beta\beta$) of $^{130}\mathrm{Te}$ to the first $0^+_2$ excited state of $^{130}\mathrm{Xe}$. Using 372.5 kg$\times$yr TeO$_2$ exposure, no significant evidence for either $0\nu\beta\beta$ or Standard Model-allowed two-neutrino double beta decay ($2\nu\beta\beta$) to this state was found. Bayesian lower bounds at 90% C.I. set half-life limits of $ (T_{1/2})^{0\nu}_{0^+_2} > 5.9 \times 10^{24}$ yr and $ (T_{1/2})^{2\nu}_{0^+_2} > 1.3 \times 10^{24}$ yr, the most stringent limits on double beta decay of $^{130}\mathrm{Te}$ to excited states, improving previous results by a factor of $\sim5$.
arXivarXiv · · January 26, 2021
0
Measurement of the 2νββνββ Decay Half-life of 130^{130}Te with CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BiassoniA. BrancaC. Brofferio  +101
Using a 300.7 kg$\cdot$yr exposure from the CUORE detector, the two-neutrino double beta decay half-life of $^{130}$Te was measured via a Bayesian analysis that disentangled background sources from the signal. The result, $T_{1/2}^{2\nu} = 7.71^{+0.08}_{-0.06}(\mathrm{stat.})^{+0.12}_{-0.15}(\mathrm{syst.})\times10^{20}$ yr, agrees with prior measurements but achieves the most precise determination to date.
arXivarXiv · · December 21, 2020
0
Improved Limit on Neutrinoless Double-Beta Decay in 130^{130}Te with CUORE
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoM. BiassoniA. BrancaC. Brofferio  +99
The CUORE collaboration reports an improved search for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{130}$Te using a 372.5 kg$\cdot$yr exposure, a fourfold increase over previous data. No evidence for decay is found, yielding a $90\%$ CI Bayesian lower limit of $3.2\cdot10^{25}$ yr on the half-life. Assuming light Majorana neutrinos, this corresponds to an effective Majorana mass upper limit of 75–350 meV, depending on nuclear matrix elements.
arXivarXiv · · December 23, 2019
0
Double-beta decay of 130{}^{130}Te to the first 0+0^+ excited state of 130{}^{130}Xe with CUORE-0
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniT. I. BanksG. BariJ.W. BeemanF. BelliniA. BersaniM. Biassoni  +109
Using a 9.8 kg·yr exposure of $^{130}$Te collected with CUORE-0, a search for double-beta decay to the first $0^+$ excited state of $^{130}$Xe found no evidence for either neutrinoless or two-neutrino modes, yielding lower half-life bounds of $\tau^{0\nu}_{0^+}>7.9\cdot 10^{23}$ yr and $\tau^{2\nu}_{0^+}>2.4\cdot 10^{23}$ yr. Combining these with CUORICINO results gives the most stringent constraints: $\tau^{0\nu}_{0^+}>1.4\cdot 10^{24}$ yr and $\tau^{2\nu}_{0^+}>2.5\cdot 10^{23}$ yr.
arXivarXiv · · November 26, 2018
0
Update on the recent progress of the CUORE experiment
CUORE CollaborationD. Q. AdamsC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoA. BersaniM. BiassoniA. Branca  +109
The CUORE experiment, a 741 kg array of 988 TeO₂ bolometers, searches for the neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te. Based on 86.3 kg·yr of TeO₂ exposure collected since 2017, it sets a $0\nu\beta\beta$ half-life limit $T^{0\nu}_{1/2} > 1.5\times10^{25}$ yr at 90% C.L. and measures the $2\nu\beta\beta$ half-life as $T_{1/2}^{2\nu} = [7.9\pm0.1\text{(stat.)}\pm0.2\text{(syst.)}]\times10^{20}$ yr, the most precise such measurement yet.
arXivarXiv · · August 30, 2018
0
5
Study of Rare Nuclear Processes with CUORE
CUORE CollaborationC. AlduinoK. AlfonsoF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoA. BersaniM. BiassoniA. BrancaC. Brofferio  +107
The CUORE experiment, a tonne-scale TeO$_2$ bolometer array, has set the most stringent limit on neutrinoless double beta decay of $^{130}\text{Te}$, with a half-life $T_{1/2}^{0\nu} > 1.5 \times 10^{25}\,\text{yr}$, corresponding to an effective Majorana neutrino mass upper bound of $140-400\,\text{meV}$. Beyond this leading result, CUORE will also study other rare nuclear processes, including two-neutrino double beta decay, electron capture, and interactions of dark matter and axions, building on past TeO$_2$ bolometer experiments.
arXivarXiv · · January 16, 2018
0
21
First Results from CUORE: A Search for Lepton Number Violation via 0νββ0νββ Decay of 130^{130}Te
CUORE CollaborationC. AlduinoK. AlfonsoE. AndreottiC. ArnaboldiF. T. Avignone IIIO. AzzoliniI. BandacT. I. BanksG. BariM. BarucciJ.W. Beeman  +153
The CUORE experiment, a ton-scale cryogenic bolometer array, performed its first high-sensitivity search for $^{130}$Te neutrinoless double-beta decay ($0\nu\beta\beta$), a lepton-number-violating process. Based on 86.3 kg$\cdot$yr of TeO$_2$ exposure with an energy resolution of $(7.7 \pm 0.5)$ keV FWHM and background of $(0.014 \pm 0.002)$ counts/(keV$\cdot$kg$\cdot$yr), no evidence for $0\nu\beta\beta$ was found. The median sensitivity was $7.0\times10^{24}$ yr, and a lower limit of $T^{0\nu}_{1/2}(^{130}\text{Te}) > 1.3\times10^{25}$ yr (90% C.L.) was set. Combined with earlier experiments, the limit increased to $>1.5\times10^{25}$ yr, the most stringent yet, corresponding to an effective Majorana neutrino mass $m_{\beta\beta} < (110-520)$ meV.
arXivarXiv · · October 22, 2017
0
Search for Neutrinoless β+ECβ^{+}\hspace{-0.2em}EC Decay of 120^{120}Te with CUORE-0
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniG. BariF. BelliniG. BenatoA. BersaniM. BiassoniA. Branca  +106
CUORE-0 searches for the neutrinoless $\beta^{+}EC$ decay of $^{120}$Te, a lepton-number-violating process. A new analysis method simultaneously fits signals with different event topologies and data subsets with varying efficiencies. The resulting half-life limit is $T_{1/2}>1.6\times10^{21}$ yr at 90% CI. Combining this with earlier Cuoricino data yields the strongest limit to date, $T_{1/2}>2.7\times10^{21}$ yr at 90% CI.
arXivarXiv · · October 20, 2017
0
Low Energy Analysis Techniques for CUORE
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniG. BariJ.W. BeemanF. BelliniG. BenatoA. BersaniM. Biassoni  +112
This paper presents low-energy analysis techniques for CUORE, a tonne-scale cryogenic detector searching for neutrinoless double-beta decay of $^{130}$Te. To enable rare-event searches like solar axions or WIMP scattering, the energy threshold is improved to 10 keV. Using data from the CUORE-0 prototype (November 2013 – March 2015), the authors detail threshold optimization, trigger efficiency monitoring, event selection, and low-energy calibration. They also show the low-energy background spectrum below 60 keV and report CUORE's sensitivity to WIMP annual modulation based on CUORE-0's performance.
arXivarXiv · · August 25, 2017
0
36
CUORE Sensitivity to 0νββ0νββ Decay
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniT. I. BanksG. BariJ.W. BeemanF. BelliniG. BenatoA. Bersani  +119
The CUORE experiment's sensitivity to neutrinoless double beta decay is evaluated via a Bayesian toy Monte Carlo analysis. With expected background and energy resolution, the 90% credibility interval exclusion sensitivity on the half-life $T_{1/2}^{0\nu}$ reaches $2\times10^{25}$ yr after 3 months and $9\times10^{25}$ yr after 5 years of live time. The corresponding $3\sigma$ discovery sensitivities are $7\times10^{24}$ yr and $4\times10^{25}$ yr, respectively.
arXivarXiv · · May 30, 2017
0
71
The projected background for the CUORE experiment
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniT. I. BanksG. BariJ.W. BeemanF. BelliniG. BenatoA. Bersani  +120
The CUORE experiment searches for neutrinoless double beta decay of $^{130}\text{Te}$ using 988 TeO$_2$ bolometers at $∼10$ mK. To achieve a $9\times10^{25}$-year half-life exclusion sensitivity, the background rate in the region of interest must be $≤10^{-2}$ counts/keV/kg/y. This paper presents a detailed Monte Carlo simulation, built from material screening, radioassays, and bolometric measurements, that projects the expected background. The model has guided the experiment's construction and now provides the background estimate for the upcoming physics run.
arXivarXiv · · April 28, 2017
0
215
Measurement of the Two-Neutrino Double Beta Decay Half-life of 130^{130}Te with the CUORE-0 Experiment
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniT. I. BanksG. BariJ.W. BeemanF. BelliniA. BersaniM. Biassoni  +114
The CUORE-0 experiment measured the two-neutrino double beta decay half-life of $^{130}$Te using a 33.4 kg$\cdot$y exposure of TeO$_2$. The result is $T_{1/2}^{2\nu} = [8.2 \pm 0.2\,(\text{stat.}) \pm 0.6\,(\text{syst.})] \times 10^{20}$ y, obtained after detailed reconstruction of the detector's counting rate and background sources, including those affecting the neutrinoless double beta decay region of interest.
arXivarXiv · · September 6, 2016
0
173
CUORE-0 detector: design, construction and operation
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniM. BalataT. I. BanksG. BariJ. W. BeemanF. BelliniA. Bersani  +142
The CUORE-0 detector, a prototype tower of 52 TeO$_2$ bolometers built using CUORE assembly procedures, operated at Laboratori Nazionali del Gran Sasso from 2013 to 2015. Its design, construction, and operation improved upon the predecessor Cuoricino, and data from CUORE-0 demonstrate that the design goals of the full 988-bolometer CUORE experiment for neutrinoless double-beta decay search are achievable.
arXivarXiv · · April 19, 2016
0
156
Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in 130^{130}Te with CUORE-0
CUORE CollaborationC. AlduinoK. AlfonsoD. R. ArtusaF. T. Avignone IIIO. AzzoliniT. I. BanksG. BariJ. W. BeemanF. BelliniA. BersaniM. Biassoni  +109
This paper details the analysis techniques used by the CUORE-0 bolometric detector array to search for neutrinoless double-beta decay in $^{130}\text{Te}$. The central contribution is a comprehensive description of the methods for data collection, event selection, and energy calibration that produced the final search spectrum. The analysis yielded a half-life limit of $T^{0\nu}_{1/2} > 2.7 \times 10^{24}$ yr for CUORE-0 alone, and $T^{0\nu}_{1/2} > 4.0 \times 10^{24}$ yr when combined with the Cuoricino experiment, establishing a competitive bound on the effective Majorana neutrino mass.
arXivarXiv · · January 6, 2016
0
Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments
CUORE CollaborationM. SistiD.R. ArtusaF.T. Avignone IIIO. AzzoliniM. BalataT.I. BanksG. BariJ. BeemanF. BelliniA. BersaniM. Biassoni  +116
CUORE, a 741 kg array of TeO₂ bolometers searching for neutrinoless double beta decay of ¹³⁰Te, aims for a 1σ half-life sensitivity of 10²⁶ y in five years at a background of 0.01 counts/keV/kg/y. Its precursor, CUORE‑0 (a single 52‑bolometer tower), began taking data in spring 2013 to verify expected performance. This paper reports CUORE’s status and presents the first CUORE‑0 data.
arXivarXiv · · February 12, 2015
0
11
CUORE-0 results and prospects for the CUORE experiment
CUORE CollaborationD.R. ArtusaF.T. Avignone IIIO. AzzoliniM. BalataT.I. BanksG. BariJ. BeemanF. BelliniA. BersaniM. BiassoniC. Brofferio  +118
The CUORE-0 detector, a single CUORE-style tower of 52 TeO₂ bolometers, tested the background and performance of the upcoming CUORE experiment. With 18.1 kg·yr exposure, CUORE-0 data show the background meets CUORE's design goal, and the projected neutrinoless double-beta decay half-life sensitivity of $1.6\times10^{26}$ yr (1σ) for $^{130}$Te in five years of live time is within reach.
arXivarXiv · · February 9, 2015
0
1
Searching for neutrinoless double-beta decay of 130^{130}Te with CUORE
CUORE CollaborationD. R. ArtusaF. T. Avignone IIIO. AzzoliniM. BalataT. I. BanksG. BariJ. BeemanF. BelliniA. BersaniM. BiassoniC. Brofferio  +109
CUORE is a cryogenic bolometer array built to search for neutrinoless double-beta decay of $^{130}$Te, a hypothesized lepton-number-violating process. The detector uses 988 TeO$_2$ crystals operated at 10 mK, containing 206 kg of $^{130}$Te with an average energy resolution of 5 keV. The projected half-life sensitivity after five years of live time is $1.6\times10^{26}$ y at $1\sigma$, corresponding to an upper limit on the effective Majorana mass of 40--100 meV.
arXivarXiv · · February 25, 2014
0
234
Initial performance of the CUORE-0 experiment
CUORE CollaborationD. R. ArtusaF. T. Avignone IIIO. AzzoliniM. BalataT. I. BanksG. BariJ. BeemanF. BelliniA. BersaniM. BiassoniC. Brofferio  +101
CUORE-0, a cryogenic array of TeO$_2$ bolometers, searches for neutrinoless double-beta decay of $^{130}$Te. Analyzing 7.1 kg·y of exposure, it measures a background rate of $0.071 \pm 0.011$ counts/keV/kg/y in the 2.47–2.57 MeV region of interest and $0.019 \pm 0.002$ counts/keV/kg/y in the 2.70–3.90 MeV $α$-dominated region—a factor of 6 improvement over its predecessor Cuoricino. The energy resolution (FWHM) in the region of interest is 5.7 keV, and with one year of live time the half-life sensitivity is expected to surpass Cuoricino's lower bound.
arXivarXiv · · February 5, 2014
0
118
Search for 14.4 keV solar axions from M1 transition of Fe-57 with CUORE crystals
Cuore CollaborationF. AlessandriaR. ArditoD. R. ArtusaF. T. Avignone IIIO. AzzoliniM. BalataT. I. BanksG. BariJ. BeemanF. BelliniA. Bersani  +103
The paper reports a search for 14.4 keV solar axions from the Fe-57 M1 transition using the axio-electric effect in TeO2 bolometers. With 43.65 kg d of CUORE test data, an upper limit of 0.63 c kg⁻¹ d⁻¹ (95% C.L.) was set, yielding a lower bound on the Peccei-Quinn energy scale fa ≥ 0.76 × 10⁶ GeV for a flavor-singlet axial vector matrix element S = 0.55, with bounds given for 0.15 < S < 0.55.
arXivarXiv · · September 13, 2012
0
63
Physics Potential and Prospects for the CUORICINO and CUORE Experiments
CUORE Collaboration
CUORICINO and CUORE are cryogenic TeO2 bolometer arrays searching for rare events, primarily neutrinoless double beta decay of 130Te. CUORICINO, with 62 detectors, is being installed; CUORE plans 1000 detectors of 760 g each. Both stages also probe WIMP dark matter and solar axions. The central contribution is the physics potential of these experiments, especially their sensitivity to lepton number violation via 0νββ decay.
arXivarXiv · · February 16, 2003
0
Frequent collaborators
O. Azzolini (24)
G. Bari (24)
F. Bellini (24)
C. Brofferio (24)
C. Bucci (24)
S. Capelli (24)
L. Cardani (24)
O. Cremonesi (24)
I. Dafinei (24)
D. Q. Fang (24)
F. Ferroni (24)
E. Fiorini (24)