Proposal for the first measurement of antiproton polarization in proton-nucleus interactions
D. AlfsD. GrzonkaG. KhatriP. KulessaJ. RitmanT. SefzickJ. SmyrskiV. VerhoevenH. XuM. Zielinski
This paper proposes the first dedicated measurement of antiproton transverse polarization in proton-nucleus collisions. The polarization is accessed via the left-right asymmetry in elastic $\bar{p}p$ scattering within the Coulomb-Nuclear Interference region. Monte Carlo simulations of a setup at CERN show the statistical sensitivity needed to detect a specific degree of polarization, which would provide new constraints on the spin structure of antinucleon-nucleon interactions.
arXivarXiv · · April 14, 2026
0
0
Time calibration of the J-PET detector
M. SkurzokM. SilarskiD. AlfsP. BialasShivaniC. CurceanuE. CzerwinskiK. DulskiA. GajosB. GlowaczM. GorgolB. C. Hiesmayr  +23
This paper presents the time calibration and synchronization of the J-PET scanner, a PET prototype for whole-body 3D imaging using organic scintillators. Each of the 192 scintillator strips arranged in three cylindrical layers is irradiated with a $^{22}\text{Na}$ source. A small detector provides a common reference time, enabling synchronization of all detector modules for high time- and angular-resolution imaging of annihilation photons.
arXivarXiv · · October 16, 2017
0
6
Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation
L. RaczyńskiW. WiślickiW.KrzemieńP. KowalskiD. AlfsT. BednarskiP. BiałasC. CurceanuE. CzerwińskiK. DulskiA. GajosB. Głowacz  +22
The paper derives closed-form analytical formulas for the time resolution of the J-PET tomograph by combining Tikhonov regularization for signal processing with Kernel Density Estimation. The method is validated on signals from a single 30 cm plastic scintillator detection unit with vacuum tube photomultipliers, showing consistency between experimental and theoretical results.
arXivarXiv · · June 3, 2017
0
Measurement of gamma quantum interaction point in plastic scintillator with WLS strips
J. SmyrskiD. AlfsT. BednarskiP. BiałasE. CzerwińskiK. DulskiA. GajosB. GłowaczN. Gupta-SharmaM. GorgolB. JasińskaM. Kajetanowicz  +20
This paper demonstrates that the axial coordinate of a gamma quantum interaction point inside a plastic scintillator bar can be measured by detecting scintillation photons escaping the bar with an array of wavelength-shifting (WLS) strips. Using a BC-420 scintillator bar and sixteen BC-482A WLS strips, a spatial resolution of 5 mm ($\sigma$) was achieved for annihilation photons from $^{22}$Na, suggesting a potential improvement for the J-PET collaboration's plastic-scintillator-based PET scanner.
arXivarXiv · · December 27, 2016
0
61
A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
D. KamińskaA. GajosE. CzerwińskiD. AlfsT. BednarskiP. BiałasC. CurceanuK. DulskiB. GłowaczN. Gupta-SharmaM. GorgolB. C. Hiesmayr  +17
This paper demonstrates that the J-PET scanner, constructed from plastic scintillators rather than the inorganic crystals used in standard PET scanners, can measure angular and energy resolutions of $\sigma(\theta) \approx 0.4^{\circ}$ and $\sigma(E) \approx 4.1$ keV for ortho-positronium $3\gamma$ decays. While Compton scattering in plastic prevents direct energy measurement, the faster signal decay in plastic reduces pileup, allowing higher source activity to compensate for lower efficiency. Monte Carlo simulations confirm J-PET's suitability for studying discrete symmetries in o-Ps decays alongside medical imaging.
arXivarXiv · · July 28, 2016
0
113
Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector
A. GajosD. KamińskaE. CzerwińskiD. AlfsT. BednarskiP. BiałasB. GłowaczM. GorgolB. JasińskaŁ. KapłonG. KorcylP. Kowalski  +19
This paper introduces a trilateration-based algorithm that simultaneously reconstructs the decay location and time of ortho-positronium atoms decaying into three photons using the positions and times of detected photons. Monte Carlo simulations with the J-PET detector yield a spatial resolution of about 2 cm (FWHM) in X and Y and 1 cm in Z after a kinematic fit. The method also enables discrimination of random three-photon background and a novel determination of ortho-positronium linear polarization, supporting tests of CP and CPT symmetries.
arXivarXiv · · February 24, 2016
0
91
Sampling FEE and Trigger-less DAQ for the J-PET Scanner
G. KorcylD. AlfsT. BednarskiP. BiałasE. CzerwińskiK. DulskiA. GajosB. GłowaczB. JasińskaD. KamińskaŁ. KapłonP. Kowalski  +20
The paper presents a complete trigger-less data acquisition system for the J-PET tomography scanner. The readout chain continuously digitizes signals without preliminary selection, generating up to 8 Gbps. A Central Controller Module based on a Xilinx Zynq SoC with 16 optical transceivers performs online event building and feature extraction. Signal discrimination uses LVDS buffers in the FPGA. This trigger-less approach preserves most information for high-level processing, a novel method for such detector systems.
arXivarXiv · · February 17, 2016
0
61
Determination of the 3γfraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner
B. JasińskaM. GorgolM. WiertelR. ZaleskiD. AlfsT. BednarskiP. BiałasE. CzerwińskiK. DulskiA. GajosB. GłowaczD. Kamińska  +21
The paper selects a mesoporous material for experiments requiring a high yield of long-lived positronium, as needed for symmetry-violation studies with the J-PET scanner. By measuring $γ$-ray energy spectra and positron annihilation lifetime spectra, the fraction of 3$γ$ annihilation in various materials is found to range from 20% to 25%. The polymer XAD-4 yields the highest 3$γ$ fraction and o-Ps formation probability, and SEM-EDS confirms its high purity.
arXivarXiv · · February 17, 2016
0
69
Scatter fraction of the J-PET tomography scanner
P. KowalskiW. WiślickiL. RaczyńskiD. AlfsT. BednarskiP. BiałasE. CzerwińskiA. GajosB. GłowaczJ. JasińskaD. KamińskaG. Korcyl  +15
The J-PET collaboration is developing a plastic-scintillator Positron Emission Tomography system. This paper simulates the scatter fraction, a key background parameter defined by the NEMA-NU-2-2012 standard. Event selection methods are designed to suppress gamma quanta scattered in the phantom or undergoing multiple scattering in the detector. For the single-layer J-PET scanner, the estimated scatter fraction ranges from 37% to 53%, depending on the applied energy threshold.
arXivarXiv · · February 17, 2016
0
39
Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system
P. MoskalD. AlfsT. BednarskiP. BiałasE. CzerwińskiC. CurceanuA. GajosB. GłowaczM. GorgolB. C. HiesmayrB. JasińskaD. Kamińska  +15
The Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector capable of testing discrete symmetries in the purely leptonic positronium system. Positronium—a parity and charge conjugation eigenstate—decays into photons. J-PET can determine expectation values of discrete-symmetries-odd operators constructed from the ortho-positronium spin and the momenta and polarization vectors of its annihilation photons, enabling tests of C, CP, T, and CPT symmetries in the leptonic sector.
arXivarXiv · · February 16, 2016
0
125
Beam profile investigation of the new collimator system for the J-PET detector
E. KubiczM. SilarskiA. WieczorekD. AlfsT. BednarskiP. BiałasE. CzerwińskiA. GajosB. GłowaczB. JasińskaD. KamińskaG. Korcyl  +14
This paper presents three methods for determining the beam profile of collimated annihilation gamma quanta for the J-PET detector. The central contribution is the demonstration that using two lead bricks of dimensions 5x10x20 cm³ forms a beam with a Gaussian profile characterized by 1 mm full width at half maximum (FWHM). This precise profile characterization is essential for detector calibration and signal reconstruction, and simulations guided the selection of an optimal collimator system balancing beam profile parameters, dimensions, and weight for the 24-module J-PET prototype.
arXivarXiv · · February 16, 2016
0
8
Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
P. MoskalO. RundelD. AlfsT. BednarskiP. BiałasE. CzerwińskiA. GajosK. GiergielM. GorgolB. JasińskaD. KamińskaŁ. Kapłon  +18
This paper introduces a method for recording timestamps of multiple photons at both ends of a plastic scintillator strip using a matrix of silicon photomultipliers (SiPM), aiming to improve the time resolution of the J-PET tomograph. Simulations show that the improvement saturates as the number of SiPM increases, and a 2x5 configuration at each end (reading twenty timestamps) is optimal. This configuration achieves a coincidence resolving time of approximately 0.170 ns for a 15 cm axial field-of-view and 0.365 ns for 100 cm, enabling a cost-effective TOF-PET scanner with better resolution and larger field-of-view.
arXivarXiv · · February 5, 2016
0
198
Overview of the software architecture and data flow for the J-PET tomography device
W. KrzemienD. AlfsP. BialasE. CzerwinskiA. GajosB. GlowaczB. JasinskaD. KaminskaG. KorcylP. KowalskiT. KozikE. Kubicz  +10
This paper presents the software architecture and data flow for the J-PET time-of-flight PET scanner. It describes the data acquisition system, reconstruction framework, and image reconstruction software, and introduces the concept of offloading computation to remote centers such as the Świerk Computing Centre in Poland, addressing the high-speed computing demands of modern TOF-PET systems.
arXivarXiv · · August 10, 2015
0
29
Frequent collaborators
M. Silarski (12)
A. Gajos (12)
G. Korcyl (12)
P. Kowalski (12)
E. Kubicz (12)
Z. Rudy (12)
P. Moskal (12)
A. Wieczorek (11)
T. Kozik (10)
L. Raczyński (10)
W. Wiślicki (10)
T. Bednarski (10)