MCP
DB

D. Bennett

36 papers in the library

Papers

30
Comparison of Nb and Ta Pentoxide Loss Tangents for Superconducting Quantum Devices
D. P. GoronzyW. W. MahP. G. LimT. GuessS. MajumderD. A. Garcia-WettenM. J. WalkerJ. RamirezW. -R. SyongD. BennettM. VissersR. dos Reis  +5
This work compares the dielectric loss of Nb₂O₅ and Ta₂O₅ pentoxides for superconducting qubits. Pulsed-laser-deposited pentoxides of three thicknesses were measured on identical coplanar waveguide resonators at single-photon, millikelvin conditions. The two-level system loss in Nb₂O₅ is about 30 % higher than in Ta₂O₅, indicating that the native pentoxide itself contributes to higher loss in Nb-based qubits, likely in addition to suboxides, which are largely absent in Ta.
arXivarXiv · · December 5, 2025
0
5
ExoClock Project IV: A homogeneous catalogue of 620 updated exoplanet ephemerides
A. KokoriA. Tsiaras…D. Bennett
The ExoClock project presents an updated catalogue of 620 exoplanet ephemerides, integrating 30,000 measurements from ground-based telescopes, literature, and space telescopes (Kepler, K2, TESS). The new ephemerides reduce prediction uncertainty by an order of magnitude, with 45% of planets requiring updates. This work supports efficient scheduling for future missions like Ariel, JWST, and ELT, and operates under open science, making all tools and products publicly accessible.
arXivarXiv · · November 18, 2025
0
ExoClock Project III: 450 new exoplanet ephemerides from ground and space observations
A. KokoriA. Tsiaras…D. Bennett
This paper presents a homogeneous catalogue of updated ephemerides for 450 exoplanets, produced by integrating ~18,000 data points from ground-based telescopes, literature, and space missions (Kepler/K2, TESS). The ExoClock project achieves a median observation coverage of half the post-discovery years with median uncertainty under one minute. Compared to literature values, these ephemerides are more precise and less biased; over 40% of initial literature ephemerides required updating. Transit Timing Variations (TTVs) are detected for 19 planets. The catalogue supports the Ariel mission's candidate monitoring.
arXivarXiv · · September 20, 2022
0
139
ExoClock project II: A large-scale integrated study with 180 updated exoplanet ephemerides
A. KokoriA. Tsiaras…D. Bennett
The ExoClock project integrates ground-telescope observations, literature mid-times, and space-instrument data to update the ephemerides of 180 exoplanets. Using ~1600 new observations and ~2350 literature values, the analysis shows that 40% of the updated ephemerides significantly improve precision or correct biases, affecting future scheduling. The updated ephemerides are publicly available.
arXivarXiv · · October 26, 2021
0
85
QUBIC IV: Performance of TES Bolometers and Readout Electronics
M. PiatG. Stankowiak…D. Bennett
QUBIC IV reports the performance of its 256 NbSi transition edge sensor (TES) bolometers and time-domain multiplexing readout. The low-noise amplifier achieved 0.3 nV/Hz$^{-0.5}$ white noise, and about 80% of detectors operated within specifications. The instrument noise equivalent power was about 2×10$^{-16}$ W/Hz$^{-0.5}$, sufficient for demonstrating bolometric interferometry, though limited by microphonics and noise aliasing.
arXivarXiv · · January 17, 2021
0
36
QUBIC I: Overview and ScienceProgram
J.-Ch. HamiltonL. Mousset…D. Bennett
QUBIC is a novel bolometric interferometer for CMB B-mode polarization that combines the systematic-error control of interferometry with the wide-band sensitivity of bolometers. Its synthesized beam's frequency-dependent shape enables multi-sub-band polarization mapping within the 150 and 220 GHz bands, aiding foreground removal. Simulations for three years of observation from Argentina, assuming perfect foreground subtraction and stable atmosphere, yield a statistical sensitivity to the effective tensor-to-scalar ratio of $\sigma(r)=0.015$.
arXivarXiv · · November 4, 2020
0
QUBIC II: Spectro-Polarimetry with Bolometric Interferometry
L. MoussetM.M. Gamboa Lerena…D. Bennett
This paper reports that bolometric interferometry enables spectral imaging, allowing a single instrument to reconstruct sky maps in multiple sub-bands from a wide frequency band. Using the QUBIC instrument, the authors demonstrate point-source reconstruction and Galactic dust mapping, characterize the frequency-dependent point spread function, and study noise correlations between sub-bands via simulations. They conclude that with QUBIC, spectral imaging performance is nearly optimal for up to five sub-bands, offering a method to separate CMB B-mode polarization from astrophysical foregrounds.
arXivarXiv · · October 28, 2020
0
0
QUBIC V: Cryogenic system design and performance
S. MasiE.S. Battistelli…D. Bennett
The QUBIC experiment's cryogenic system, designed for long-duration CMB polarization measurements, is presented. The system uses two pulse-tube refrigerators to cool a ~1 m³, ~165 kg instrument to ~3K. A ⁴He evaporator cools the beam combiner to ~1K, and a ³He evaporator cools the detector arrays to ~0.33K. The system operated stably for over six months, and tilting from 20° to 90° elevation caused no significant temperature changes, confirming readiness for deployment.
arXivarXiv · · August 24, 2020
0
29
QUBIC VI: cryogenic half wave plate rotator, design and performances
G. D'AlessandroL. Mele…D. Bennett
The QUBIC Stokes polarimeter rotates a half-wave plate (HWP) at cryogenic temperature to modulate polarization while minimizing spurious signals from optical element emissivity. Its rotation is driven by an external stepper motor to avoid thermal load at low temperature. Tests show positioning precision below 0.1° and an extra power load of only a few mK on the ~8 K cryogenic stage.
arXivarXiv · · August 24, 2020
0
QUBIC III: Laboratory Characterization
S.A. TorchinskyJ.-Ch. Hamilton…D. Bennett
The QUBIC Technological Demonstrator successfully validates bolometric interferometry through laboratory characterization. A prototype scanned a far-field modulated millimeter-wave source to produce synthesized beam maps, achieving measured beams matching theoretical simulations and enabling spectro-imaging. Polarization performance showed less than 0.5% cross-polarization rejection. The instrument is now ready for deployment in Argentina.
arXivarXiv · · August 23, 2020
0
28
QUBIC VIII: Optical design and performance
C. O'SullivanM. De Petris…D. Bennett
QUBIC uses bolometric interferometry to detect CMB B-mode polarisation around the recombination peak. A cold reflective combiner overlays beams from 400 feedhorns onto two focal planes, combining imager sensitivity with interferometer systematic-error control. A fixed groundshield and a moving forebaffle limit local contamination. The paper presents the optics modelling, design, manufacturing, and preliminary measurements.
arXivarXiv · · August 23, 2020
0
36
QUBIC: the Q & U Bolometric Interferometer for Cosmology
E.S. BattistelliP. Ade…D. Bennett
QUBIC combines Transition Edge Sensor bolometers with interferometric techniques to measure the faint polarization signal of the cosmic microwave background left by inflation. This hybrid design achieves the sensitivity of cryogenic detectors and the systematic-error control of an interferometer, distinguishing it from classical imaging CMB experiments. The instrument, demonstrated in the lab, will be deployed in Argentina at the end of 2019.
arXivarXiv · · January 28, 2020
0
21
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
M. PiatB. Bélier…D. Bennett
QUBIC is a ground-based CMB experiment that measures polarized fluctuations using bolometric interferometry, combining the systematic-immunity of an interferometer with the sensitivity of cryogenic detectors. Its detection chain uses 2048 NbSi Transition Edge Sensors (TESs) cooled to 350 mK, read out via time-domain multiplexing (MUX factor 128) with SQUIDs at 1 K and a SiGe ASIC at 60 K. Characterization results from a reduced detector setup are presented, focusing on the detectors and readout system.
arXivarXiv · · November 27, 2019
0
The Potential of Exozodiacal Disks Observations with the WFIRST Coronagraph Instrument
B. MennessonV. BaileyJ. KasdinJ. TraugerO. AbsilR. AkesonL. ArmusJ. L. BaudinoP. BaudozA. BelliniD. BennettB. Berriman  +51
The WFIRST Coronagraph Instrument (CGI), the first space coronagraph with active wavefront control, will achieve contrast below $10^{-7}$ in the optical. This enables imaging and low-resolution spectroscopy of exozodiacal dust in the habitable zone of nearby sunlike stars, down to densities comparable to the Solar System's zodiacal cloud. Such observations cross a threshold where disk structure is dominated by transport rather than collisions, informing dust production and transport in mature low-density disks. CGI will also constrain asymmetry at roughly ten times solar zodiacal emission, aiding future exo-Earth imaging missions like HabEx and LUVOIR.
arXivarXiv · · September 5, 2019
0
2
Astro2020 Science White Paper: Science at the edges: internal kinematics of globular clusters' external fields
A. BelliniM. LibralatoJ. AndersonD. BennettA. CalamidaS. CasertanoS. M. FallB. S. GaudiP. GuhathakurtaS. HoJ. LuS. Malhotra  +8
This white paper argues that the outer regions of globular clusters, though observationally uncharted, hold answers to fundamental questions about cluster formation, stellar populations, and Milky Way dynamics. It identifies high-precision proper motions of low-mass stars over a large field of view as the key to exploring these outskirts, and positions the Wide Field InfraRed Survey Telescope (WFIRST) as the ideal instrument for this task due to its unique combination of capabilities.
arXivarXiv · · March 12, 2019
0
1
The Diverse Science Return from a Wide-Area Survey of the Galactic Plane
R.A. StreetM.B. Lund…D. Bennett
LSST's resolution and Difference Image Analysis enable a high-cadence (2-3 d) survey of the Galactic Plane, a region previously avoided due to stellar crowding. This paper argues that such a survey would yield diverse science, especially measuring the black hole mass spectrum and mapping exoplanet populations across varying star-forming environments. The authors outline survey strategies that maximize returns for fields including young stellar objects, cataclysmic variables, and Neptune Trojans.
arXivarXiv · · December 7, 2018
0
2
Unique Science from a Coordinated LSST-WFIRST Survey of the Galactic Bulge
R.A. StreetM.B. LundM. DonachieS. KhakpashN. GolovichM. PennyD. BennettW.A. DawsonJ. PepperM. RabusP. SzkodyW.I. Clarkson  +10
This paper proposes a coordinated survey of the Galactic Bulge by LSST (as a Deep Drilling Field) and WFIRST, which will perform a NIR microlensing exoplanet survey. The authors argue that the timing overlap (mid-2020s, midway through LSST) enables unique synergy, with LSST covering the full WFIRST footprint. The central contribution is an exploration of the scientific potential and recommendation of effective observing strategies for this joint program.
arXivarXiv · · December 7, 2018
0
5
Thermal architecture for the QUBIC cryogenic receiver
A.J. MayC. Chapron…D. Bennett
The QUBIC cryogenic receiver uses a four-stage thermal architecture (40 K, 4 K, 1 K, 350 mK) driven by two pulse tube coolers, a novel 4He sorption cooler, and a double-stage 3He/4He sorption cooler. This design enables bolometric interferometry for measuring the B-mode polarization of the cosmic microwave background. The paper presents the thermal and mechanical design, modeling, and laboratory cryogenic testing of the receiver.
arXivarXiv · · November 6, 2018
0
11
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background
A. MennellaP.A.R. AdeJ. AumontS. BanfiP. BattagliaE.S. BattistelliA. BaùB. BélierD.BennettL. BergéJ.Ph. BernardM. Bersanelli  +96
QUBIC is a novel instrument that combines the sensitivity of bolometric detectors with the systematic-effects control of interferometers to detect polarized signals from the cosmic microwave background, specifically primordial gravitational waves. Its key contribution is "self-calibration", a technique intrinsic to its interferometric design that removes instrumental effects from the measured data. The first module, a dual-band instrument at 150 GHz and 220 GHz, was set for deployment in Argentina in fall 2018.
arXivarXiv · · January 11, 2018
0
3
Measuring the electron neutrino mass with improved sensitivity: the HOLMES experiment
A. GiacheroB. AlpertD. BeckerD. BennettM. BiasottiC. BrofferioV. CerialeG. CerutiD. CorsiniP. DayM. De GeroneR. Dressler  +30
The HOLMES experiment aims to directly measure the electron neutrino mass with a sensitivity below 2 eV by calorimetrically detecting the energy released in $^{163}$Ho decay. This calorimetric approach eliminates systematic uncertainties inherent in spectrometer-based beta decay experiments. HOLMES will use a large array of low-temperature microcalorimeters (Mo/Cu bilayer TESs on SiN$_x$ membranes with gold absorbers) implanted with $^{163}$Ho, aiming to collect about $3\times10^{13}$ decays with 1000 detectors having an energy resolution of a few eV and a time resolution of a few microseconds. The experiment also demonstrates the potential of this technique to reach sensitivities down to 0.1 eV.
arXivarXiv · · December 12, 2016
0
22
Spectroscopic characterisation of microlensing events Towards a new interpretation of OGLE-2011-BLG-0417
A. SanterneJ.-P. BeaulieuB. Rojas AyalaI. BoisseE. SchlawinJ.-M. AlmenaraV. BatistaD. BennettR. F. DíazP. FigueiraD. J. JamesT. Herter  +5
UVES and new near-infrared observations of the bright microlensing event OGLE-2011-BLG-0417 reveal a spectral energy distribution (SED) incompatible with the published lens parameters. The SED fits a foreground star of $0.94\pm0.09\,M_\odot$ at $1.07\pm0.24\,\mathrm{kpc}$, contradicting the earlier $0.52\pm0.04\,M_\odot$ at $0.95\pm0.06\,\mathrm{kpc}$ from light-curve modelling. This work shows that spectroscopic follow-up can independently constrain lens and source properties, breaking degeneracies that photometry alone cannot resolve.
arXivarXiv · · October 14, 2016
0
16
QUBIC Technical Design Report
J. AumontS. BanfiP. BattagliaE.S. BattistelliA. BaùB. BélierD.BennettL. BergéJ.Ph. BernardM. BersanelliM.A. Bigot-SazyN. Bleurvacq  +87
The QUBIC instrument is designed to measure CMB B-mode polarization anisotropies at multipoles 30–200. It is a bolometric interferometer that combines background-limited Transition-Edge-Sensor sensitivity with systematic control via interference fringe patterns, operating at two frequencies to separate polarized foregrounds from primordial B-mode signal. This Technical Design Report provides a detailed description of its characteristics.
arXivarXiv · · September 14, 2016
0
15
Algorithms for Identification of Nearly-Coincident Events in Calorimetric Sensors
B. AlpertE. FerriD. BennettM. FaverzaniJ. FowlerA. GiacheroJ. Hays-WehleM. MainoA. NucciottiA. PuiuD. SwetzJ. Ullom
For calorimetric neutrino-mass experiments like HOLMES, unidentified pulse pile-ups from nearly-coincident events are a leading error source. Wiener filtering for pile-up detection suffers from detector nonlinearity, sub-sample arrival-time dependence, and ill-posed deconvolution. This work develops a method using singular value decomposition to separate single-pulse from piled-up training records and build a model of single pulses that accounts for varying shape with amplitude, arrival time, and baseline. This enables reliable pile-up identification, reducing detector or readout requirements or allowing larger sensor arrays.
arXivarXiv · · December 5, 2015
0
35
Wide-Field InfrarRed Survey Telescope-Astrophysics Focused Telescope Assets WFIRST-AFTA 2015 Report
D. SpergelN. GehrelsC. BaltayD. BennettJ. BreckinridgeM. DonahueA. DresslerB. S. GaudiT. GreeneO. GuyonC. HirataJ. Kalirai  +43
This report presents the 2014 Science Definition Team study of the Wide-Field Infrared Survey Telescope (WFIRST) mission, which uses a 2.4-m telescope with a wide-field infrared instrument and an optical coronagraph to address dark energy, exoplanet demographics, and general astrophysics. The 2.4-m mirror, a Hubble-quality assembly made available to NASA, provides greater sensitivity and higher angular resolution than earlier 1.3-m and 1.1-m designs. An on-axis coronagraphic instrument enables imaging and spectroscopy of planets around nearby stars.
arXivarXiv · · March 12, 2015
0
921
HOLMES - The Electron Capture Decay of 163Ho to Measure the Electron Neutrino Mass with sub-eV sensitivity
B. AlpertM. BalataD. BennettM. BiasottiC. BoragnoC. BrofferioV. CerialeD. CorsiniP.K. DayM. De GeroneR. DresslerM. Faverzani  +26
HOLMES directly measures the electron neutrino mass by calorimetrically detecting the energy released in the electron capture decay of $^{163}\mathrm{Ho}$. This calorimetric approach eliminates systematic uncertainties from external beta sources used in spectrometer-based experiments. The experiment uses a large array of low-temperature microcalorimeters with implanted $^{163}\mathrm{Ho}$ nuclei, aiming for a sensitivity of 0.4 eV and potentially 0.1 eV.
arXivarXiv · · December 16, 2014
0
A study of decays to strange final states with GlueX in Hall D using components of the BaBar DIRC
GlueX CollaborationM. Dugger…D. Bennett
This paper proposes enhancing the GlueX detector's kaon identification by building an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector from decommissioned BaBar DIRC components, reusing one-third of its synthetic fused silica bars. The upgrade would enable systematic studies of hybrid meson decays into strange final states, essential for determining quark flavor content. The enhanced detector would operate in Hall D for 220 days at $5\times10^7$ $\gamma$/s, a program conditionally approved by PAC39.
arXivarXiv · · August 1, 2014
0
18
Explaining Phenomenologically Observed Space-time Flatness Requires New Fundamental Scale Physics
D. BennettH. B. Nielsen
This paper argues that the observed near-flatness of spacetime cannot be explained by continuum Planck-scale physics, because dimensional analysis shows any such action yields chaotic Christoffel symbols. The authors propose new fundamental fields that spontaneously break translational invariance; using these fields as coordinates, the metric is defined so that the Riemann tensor vanishes identically as a Bianchi identity, enforcing flatness. General relativity with curvature emerges at larger scales, where crystal-like disclinations act as sources of curvature.
arXivarXiv · · June 12, 2013
0
Wide-Field InfraRed Survey Telescope-Astrophysics Focused Telescope Assets WFIRST-AFTA Final Report
D. SpergelN. Gehrels…D. Bennett
This report describes the Design Reference Mission for the Wide-Field InfraRed Survey Telescope (WFIRST) using a 2.4-m, Hubble-quality mirror assembly. The mission, recommended by the Astro2010 Decadal Survey, will carry out dark energy science, a microlensing exoplanet census, and a general observing program. The 2.4-m aperture provides greater sensitivity and angular resolution than earlier designs. An optional coronagraph would enable direct imaging and spectroscopy of exoplanets.
arXivarXiv · · May 23, 2013
0
268
WFIRST-2.4: What Every Astronomer Should Know
D. SpergelN. Gehrels…D. Bennett
The WFIRST-2.4 mission, recommended by the Astro2010 Decadal Survey, uses a 2.4-m, Hubble-quality mirror to achieve greater sensitivity and higher angular resolution than previous designs. This enables enhanced surveys in dark energy, exoplanet demographics, galaxy evolution, and Milky Way stellar populations. A possible coronagraphic instrument would directly image and study planets around nearby stars. The paper summarizes the Design Reference Mission from the Science Definition Team report.
arXivarXiv · · May 23, 2013
0
47
An initial study of mesons and baryons containing strange quarks with GlueX
GlueX CollaborationA. AlekSejevs…D. Bennett
The GlueX experiment aims to study gluonic excitations in the meson spectrum via $\(\gamma p\)$ collisions. A systematic amplitude analysis of many hadronic final states containing kaons is needed to map the predicted hybrid meson spectrum, including strange-quark components. The authors propose collecting 200 days of data at $5\times 10^7$ tagged photons/s, enabling an order-of-magnitude statistical improvement over initial running. This will allow the first program of studying mesons and baryons with strange quarks, significantly advancing knowledge of hybrid mesons and excited $\(\Xi\)$ baryons.
arXivarXiv · · May 7, 2013
0
17
Frequent collaborators
M. Piat (13)
P. de Bernardis (13)
S. Marnieros (13)
S. Masi (13)
A. Tartari (13)
F. Voisin (13)
M. Zannoni (13)
L. Dumoulin (13)
M. Gervasi (13)
M. Giard (13)
M. Gradziel (13)
J. Kaplan (13)