MCP
DF

D. Fuchs

51 papers in the library

Papers

30
The liquid-phase xenon purification system of the XENONnT dark matter experiment
E. AprileJ. Aalbers…D. Fuchs
The XENONnT dark matter experiment developed a liquid-phase xenon purification system to remove impurities, particularly O$_2$, from 8.5 t of liquid xenon, achieving an O$_2$-equivalent concentration below 100 ppt needed for sensitivity. The system circulates liquid xenon (~2 L/min at ~175 K) through two purifier types: a Q5 copper-on-alumina purifier with nearly 100% efficiency for initial cleanup, followed by a St707 getter purifier with 55% efficiency for sustained operation with negligible background. Commissioning achieved below 19 ppt, with over 86% electron survival across the 1.5-meter TPC.
arXivarXiv · · October 23, 2026
0
0
Pulse Shape Model for a Light Enhanced Phonon Detector
G. AngloherM. R. Bharadwaj…D. Fuchs
COSINUS prototypes of NaI-based cryogenic scintillating calorimeters, with the transition edge sensor on a separate carrier crystal, showed pulse shape deviations and no identifiable nuclear recoil population in neutron calibration. This work presents a new pulse shape model explaining these observations, showing the prototypes acted as light enhanced phonon detectors where phonons are enhanced by light absorption in the carrier. This design allows single-channel particle discrimination. Recent results use a Bayesian pulse shape fitting method based on BAT.jl.
arXivarXiv · · October 20, 2026
0
0
Search for Magnetic and Spin-Independent Inelastic Dark Matter with XENONnT
E. AprileJ. Aalbers…D. Fuchs
XENONnT sets 90% C.L. upper limits on magnetic and spin-independent inelastic dark matter using 2.1 tonne-years of data. The search exploits the delayed de-excitation photon after an initial nuclear recoil, applying directional and kinematic selections on the inferred speed and direction of the excited particle between scatter and decay sites. No signal is found, yielding constraints across the GeV/c$^2$–TeV/c$^2$ mass range.
arXivarXiv · · August 15, 2026
0
1
Optimization studies of silicon remoTES cryogenic calorimeters
G. AngloherM. R. Bharadwaj…D. Fuchs
This paper reports optimization studies of silicon remoTES cryogenic calorimeters, a design where the Transition Edge Sensor (TES) is on a separate chip thermally coupled to the absorber via a gold link. By testing a new Au link design and three phonon collector configurations (Au, Cu, and Al/Au), the authors reduced thermal boundary resistance and improved signal transmission. The best configuration, Al/Au, achieved a baseline resolution of $(21.5 \pm 0.3)\,$\mathrm{eV}$.
arXivarXiv · · August 10, 2026
0
0
Direct Measurement of the 212Pb^{212}\mathrm{Pb} and 214Pb^{214}\mathrm{Pb} β\beta Decay Branching Ratios with the XENONnT Experiment
E. AprileJ. Aalbers…D. Fuchs
Using calibration data from the XENONnT dual-phase liquid xenon time projection chamber, this work reports the most precise direct measurements of the $^{212}\mathrm{Pb}$ and $^{214}\mathrm{Pb}$ $\beta$-decay branching ratios to the ground state. The measured values are $(14.75 \pm 0.20(\mathrm{stat}) ^{+0.14}_{-0.40}(\mathrm{sys}))\%$ for $^{212}\mathrm{Pb}$ and $(9.8 \pm 0.3(\mathrm{stat}) ^{+0.8}_{-0.2}(\mathrm{sys}))\%$ for $^{214}\mathrm{Pb}$. These results improve background modeling for rare-event searches, thereby enhancing sensitivity to dark matter and solar neutrinos.
arXivarXiv · · June 16, 2026
0
0
Optimisation of TES design for the CRESST experiment
G. AngloherS. Banik…D. Fuchs
This work presents an optimisation study of tungsten transition-edge sensors (W-TESs) for the CRESST dark matter experiment. By systematically investigating the thickness, dimensions, and material composition of phonon collectors, the authors demonstrate a significant improvement in the signal-to-noise ratio and overall detector performance, establishing new benchmarks for the sensors used in CRESST.
arXivarXiv · · May 8, 2026
0
3
Cosmic Ray Boosted Dark Matter in COSINUS: Modeling and Constraints
G. AngloherM. R. Bharadwaj…D. Fuchs
This work models boosted dark matter (DM) in the COSINUS experiment. Cosmic rays or neutrinos scatter off sub-GeV DM, boosting its kinetic energy to detectable levels. The authors present a catalog of DM-nucleon scattering cross sections for spin-0, 1/2, and 1 DM, with scalar and vector mediators of even or odd parity, in the heavy mediator limit. They then project constraints on the cross section for COSINUS with a 100 kg d exposure, showing sensitivity to sub-GeV boosted DM.
arXivarXiv · · March 24, 2026
0
0
Enhancing Neutrinoless Double-Beta Decay Sensitivity of Liquid-Xenon Time Projection Chamber with Augmented Convolutional Neural Network
E. AprileJ. Aalbers…D. Fuchs
Gamma-ray backgrounds from detector materials limit neutrinoless double-beta decay ($0\nu\beta\beta$) searches in liquid-xenon time projection chambers. The authors built an augmented convolutional neural network (A-CNN) that extracts additional event-topology information from the detector data. Using XENONnT simulation and calibration data, the model rejects over 60% of the background while retaining 90% signal acceptance, improving the projected $^{136}$Xe $0\nu\beta\beta$ sensitivity by about 40%.
arXivarXiv · · March 20, 2026
0
0
ImpCresst -- A versatile simulation tool focusing on solid-state detectors at keV energies
G. AngloherS. Banik…D. Fuchs
This paper introduces ImpCresst, a Geant4-based Monte Carlo tool for simulating backgrounds and calibration signals in solid-state detectors at keV energies. Originally developed by the CRESST collaboration, it features dynamic geometry from CAD files, ROOT-based data persistency, automatic metadata annotation, and a novel particle generator for radioactive bulk and surface contaminations independent of user-defined confinement volumes. The auxiliary tool CresstDS applies empirical detector-specific energy and time resolutions. The tool is designed for flexibility and suitability in heterogeneous detector environments.
arXivarXiv · · March 2, 2026
0
2
Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT
E. AprileJ. Aalbers…D. Fuchs
This paper reports a search for dark matter using ionization-only signals from 7.83 tonne$\times$year of XENONnT exposure. No significant excess was found, and the strongest constraints were set on spin-independent DM–nucleon scattering, excluding cross sections above $6.0\times10^{-45}$ cm$^2$ at a DM mass of 5 GeV/$c^2$, pushing sensitivity toward the neutrino fog.
arXivarXiv · · January 16, 2026
0
28
Defect Formation in NaI Crystals: A Novel Pathway to Dark Matter Detection
G. AngloherM. R. Bharadwaj…D. Fuchs
This paper uses molecular dynamics and density functional theory to simulate dark matter collisions on NaI crystals, focusing on defect formation. The central contribution is a characterization of the structural and electronic properties of resulting defects (interstitials, vacancies and their band-gap states) and the anisotropic threshold displacement energy. The authors propose exploiting these dark-matter-induced defects as a novel detection channel for scintillating calorimeters such as those in the COSINUS experiment.
arXivarXiv · · December 29, 2025
0
3
Constraints on Solar Reflected Dark Matter from a combined analysis of XENON1T and XENONnT data
XENON CollaborationE. Aprile…D. Fuchs
This work searches for sub-GeV dark matter upscattered by solar reflection in the heavy mediator scenario. By analyzing XENON1T ionization-only and XENONnT low-energy electronic recoil data, they enhance sensitivity to low-mass dark matter via electron scattering and reduced detection thresholds. The analysis excludes previously unconstrained dark matter-electron scattering cross sections for masses between $4.6\,\text{keV}/c^2$ and $20\,\text{keV}/c^2$, and between $0.2\,\text{MeV}/c^2$ and $2\,\text{MeV}/c^2$, reaching a minimum of $3.41\times10^{-39}\,\text{cm}^2$ at $0.3\,\text{MeV}/c^2$ (90% confidence level).
arXivarXiv · · December 22, 2025
0
0
Spectral Measurement of the 214^{214}Bi beta-decay to the 214^{214}Po Ground State with XENONnT
E. AprileJ. Aalbers…D. Fuchs
Using the XENONnT detector, we measure the $^{214}$Bi beta-decay spectrum to the $^{214}$Po ground state, a first-forbidden non-unique transition. A dedicated algorithm selects a high-purity sample of ground-state decays, excluding events with gamma rays. Comparing the measured spectrum (up to 3.27 MeV) with nuclear models, the conserved vector current (CVC) hypothesis best describes the data. This dataset also yields charge and light yield curves for electronic recoils, extending detector response modeling to the MeV scale.
arXivarXiv · · October 6, 2025
0
2
Description of CRESST-III lithium aluminate data
G. AngloherS. Banik…D. Fuchs
The paper describes the CRESST-III data set from two lithium aluminate detector modules operated in 2021, which produced the strongest spin-dependent dark matter cross-section limits for 0.25–1.5 GeV/c² masses. It specifies how to use the publicly available data to reproduce the reported dark matter results.
arXivarXiv · · August 5, 2025
0
1
Experimental Observation of Short-Range Magnetic Correlations in Amorphous Nb2_2O5_5 and Ta2_2O5_5 Thin Films
Y. V. KrasnikovaA. A. Murthy…D. Fuchs
Using muon spin rotation/relaxation/resonance, the authors observe magnetic responses at 2.8 K in amorphous Nb₂O₅ and Ta₂O₅ thin films. The character of the magnetism is structurally dependent: fully amorphous Ta₂O₅ shows local static magnetism, whereas the response in amorphous Nb₂O₅ is dominated by magnetic fluctuations and stronger disorder. These differences in short-range magnetic correlations may explain performance limitations in superconducting qubits and resonators.
arXivarXiv · · May 12, 2025
0
5
The CRESST experiment: towards the next-generation of sub-GeV direct dark matter detection
G. AngloherS. Banik…D. Fuchs
The CRESST experiment upgrade will deploy about 100 detectors with masses from 2g to 24g to achieve unprecedented sensitivity to sub-GeV dark matter particles, focusing on spin-independent dark matter-nucleus scattering. The paper presents the experimental strategies, projected sensitivities, and approaches to mitigate low-energy excess backgrounds, which have been a key limitation in previous sub-GeV searches. A long-term roadmap for the next decade is also outlined.
arXivarXiv · · May 2, 2025
0
12
WIMP Dark Matter Search using a 3.1 Tonne-Year Exposure of the XENONnT Experiment
E. AprileJ. Aalbers…D. Fuchs
The XENONnT experiment reports a WIMP dark matter search using 3.1 tonne-years of exposure from two science campaigns. A blind analysis of nuclear recoil events above 3.8 keV$_{NR}$ found no significant excess. The resulting upper limit on the spin-independent WIMP-nucleon cross section reaches a minimum of $1.7 \times 10^{-47}\,\mathrm{cm}^2$ at 90% CL for a 30 GeV/$c^2$ WIMP, with a best median sensitivity of $1.4 \times 10^{-47}\,\mathrm{cm}^2$ for a 41 GeV/$c^2$ WIMP, improving sensitivity up to 1.8 times over the first campaign.
arXivarXiv · · February 25, 2025
0
221
Flexible strained membranes of multiferroic TbMnO3
H. ShiF. RingeD. WangO. MoranK. NayakA. K. JaiswalM. Le TaconD. Fuchs
This paper reports the preparation of elastic freestanding TbMnO3 membranes with (001) or (010) orientation, 20 nm thick, showing bulk-like lattice parameters and strong twinning suppression in (010) membranes. Using a commercial strain cell, tensile strain up to ~0.5% shifts the B1g oxygen-stretching Raman mode to lower energy, indicating controlled Mn-O bond modification. This allows strain manipulation of the multiferroic state, with crystallographic orientation enabling in- or out-of-plane electric polarization.
arXivarXiv · · May 27, 2024
0
First observation of single photons in a CRESST detector and new dark matter exclusion limits
CRESST CollaborationG. Angloher…D. Fuchs
The CRESST-III experiment reports the first observation of single-luminescence photons in the eV range using a 0.6\,g silicon-on-sapphire cryogenic detector with an energy threshold of (6.7\, \pm \,0.2)\,eV and a baseline resolution of (1.0\, \pm \,0.2)\,eV. This calibration enabled new exclusion limits on dark matter-nucleon scattering that extend to dark matter particle masses below 100\,MeV/$c^{2}$.
arXivarXiv · · May 10, 2024
0
62
A likelihood framework for cryogenic scintillating calorimeters used in the CRESST dark matter search
CRESST CollaborationG. Angloher…D. Fuchs
This paper presents a likelihood framework that models backgrounds and a potential dark matter signal in the two-dimensional plane of phonon and scintillation light energies for cryogenic scintillating calorimeters. Applied to CaWO4-based CRESST detectors, it is the first single framework in CRESST to simultaneously fit calibration and physics data and extract dark matter results in one step via a profile likelihood ratio test. The framework can be expanded to other materials and experiments.
arXivarXiv · · March 6, 2024
0
15
Optimal operation of cryogenic calorimeters through deep reinforcement learning
G. AngloherS. Banik…D. Fuchs
This paper automates the optimization of cryogenic phonon detectors with transition-edge sensors using deep reinforcement learning. The method tunes the thermometer temperature and bias current to achieve optimal detector performance. It was tested in simulation and on three real CRESST detectors in an underground setup, matching human-expert results in speed and quality. This reduces manual intervention, enabling large-scale detector tuning.
arXivarXiv · · November 26, 2023
0
5
Detector development for the CRESST experiment
G. AngloherS. Banik…D. Fuchs
The CRESST-III dark matter search faces a low-energy background that rises sharply below 200 eV, limiting its physics reach. To investigate this unexplained signal, the collaboration developed three new detector layouts. These designs are presented as a step toward understanding the background's origin and improving the sensitivity of low-mass dark matter direct detection.
arXivarXiv · · November 13, 2023
0
17
Light Dark Matter Search Using a Diamond Cryogenic Detector
CRESST CollaborationG. Angloher…D. Fuchs
By operating diamond as a cryogenic calorimeter with a 16.8 eV energy threshold, this work sets exclusion limits on the elastic spin-independent dark matter–nucleon cross section down to dark matter masses of 0.122 GeV/c². Two 0.175 g CVD diamond samples instrumented with tungsten transition-edge sensors were measured. The limits demonstrate the scientific potential of diamond as a target material for low-mass dark matter direct detection.
arXivarXiv · · October 9, 2023
0
11
Results on sub-GeV Dark Matter from a 10 eV Threshold CRESST-III Silicon Detector
CRESST CollaborationG. Angloher…D. Fuchs
The CRESST-III experiment reports a new limit on spin-independent dark matter–silicon scattering using a 0.35 g cryogenic calorimeter with the lowest-ever baseline nuclear recoil energy resolution of $(1.36\pm 0.05)$ eV$_{\text{nr}}$ and a threshold of $(10.0\pm 0.2)$ eV$_{\text{nr}}$. This improves sensitivity to sub-GeV dark matter (mass below 160 MeV/c$^2$) by up to 20× over earlier results. The observed low-energy excess is characterized, ruling out noise triggers and surface radioactive contamination as dominant sources.
arXivarXiv · · December 23, 2022
0
90
Towards an automated data cleaning with deep learning in CRESST
G. AngloherS. Banik…D. Fuchs
For the CRESST dark matter experiment, the authors frame the manual cleaning of cryogenic calorimeter signals—removing pile-up and read-out artefacts—as a time-series classification task. Testing four neural network architectures on over one million labeled records from 68 detectors, their best model achieves 0.932 balanced accuracy. They further show that about half of the model's errors on one detector are actually mislabeled data, and most remaining errors have context-dependent ground truth, demonstrating that the trained classifiers are well suited for automated data cleaning.
arXivarXiv · · November 1, 2022
0
30
Latest observations on the low energy excess in CRESST-III
G. AngloherS. Banik…D. Fuchs
The CRESST-III experiment reports an unexplained low-energy excess in its latest data. By comparing detectors with different designs, the collaboration finds that the excess shows no dependence on time, energy, or temperature in ways that would be consistent with dark matter, radioactive backgrounds, or intrinsic crystal-bulk sources. These observations rule out those major candidate explanations, narrowing the search for the origin of the excess.
arXivarXiv · · July 19, 2022
0
47
Testing spin-dependent dark matter interactions with lithium aluminate targets in CRESST-III
G. AngloherS. Banik…D. Fuchs
The CRESST-III experiment operated two 10.46 g LiAlO$_2$ cryogenic detector modules and used the odd-proton/odd-neutron isotopes $^6$Li, $^7$Li, and $^{27}$Al to achieve the currently strongest upper limits on the spin-dependent dark matter-nucleon cross section for dark matter masses between 0.25 and 1.5 GeV/c$^2$.
arXivarXiv · · July 15, 2022
0
69
A low-threshold diamond cryogenic detector for sub-GeV Dark Matter searches
A. H. AbdelhameedG. AngloherA. BentoE. BertoldoA. BertoliniL. CanonicaN. Ferreiro IachelliniD. FuchsA. GaraiD. HauffA. NilimaM. Mancuso  +4
We report the first cryogenic detector using diamond as absorber for sub-GeV dark matter searches. Two 0.175 g CVD diamond samples, each instrumented with a W-TES and operated at about 25 mK, were tested. The best-performing device achieved an energy threshold of 16.8 eV, making diamond a promising material for low-threshold, high-resolution applications such as light dark matter searches and coherent elastic neutrino-nucleus scattering.
arXivarXiv · · March 22, 2022
0
EXCESS workshop: Descriptions of rising low-energy spectra
P. AdariA. Aguilar-Arevalo…D. Fuchs
This paper reports the outcome of the first EXCESS Workshop (June 2021), where ten low-threshold dark-matter and neutrino experiments (CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI, SuperCDMS) shared observed energy spectra and known backgrounds. The central contribution is a comprehensive overview of the similarities and differences among these measurements, all showing sharply rising event rates below a few hundred eV that exceed expected backgrounds. The data and a visualization tool are publicly available at the workshop’s repository.
arXivarXiv · · February 10, 2022
0
137
Probing spin-dependent dark matter interactions with 6^6Li
G. AngloherG. Benato…D. Fuchs
CRESST, a direct detection experiment for sub-GeV/c$^2$ dark matter, can include diverse nuclides in its target. This work uses new calculations of nuclear matrix elements to incorporate $^{6}$Li into the analysis of previously collected CRESST prototype data. The inclusion of $^{6}$Li drastically improves limits on spin-dependent dark matter interactions with neutrons across the entire mass range, with an improvement of over two orders of magnitude for masses below 1 GeV/c$^2$.
arXivarXiv · · January 11, 2022
0
Frequent collaborators
F. Petricca (22)
M. Mancuso (21)
G. Angloher (20)
S. Fichtinger (19)
F. Reindl (19)
J. Schieck (19)
C. Schwertner (19)
M. Stahlberg (19)
V. Zema (19)
A. Bento (18)
L. Canonica (18)
F. Pröbst (17)