MCP
DI

D. Indurthy

9 papers in the library

Papers

9
The NuMI Neutrino Beam
P. AdamsonK. Anderson…D. Indurthy
The paper describes the hardware, operations, and design considerations of the NuMI neutrino beam at Fermilab. It details key components, beam monitoring systems, procedures for tuning and alignment, and reports on the long-term performance of the beam. The work constitutes a comprehensive technical reference on the NuMI beamline.
arXivarXiv · · July 23, 2015
0
591
Beam-Based Alignment of the NuMI Target Station Components at FNAL
R. ZwaskaM. BishaiS. ChildressG. DrakeC. EscobarP. GouffonD.A. HarrisJ. HylenD. IndurthyG. KoizumiS. KoppP. Lucas  +6
The relative alignment of the NuMI target, focusing horns, and primary proton beam at FNAL affects the delivered neutrino energy spectrum. This paper reports a beam-based check of the alignment of these components by using the proton beam itself, providing a direct method to verify the positioning of the target station components without relying on external surveys.
arXivarXiv · · September 13, 2006
0
Secondary Beam Monitors for the NuMI Facility at FNAL
S. KoppM. BishaiM. DierckxsensM. DiwanA.R. ErwinD.A. HarrisD. IndurthyR. KeislerM. KostinM. LangJ. MacDonaldA. Marchionni  +11
Four arrays of ionization chambers were built for the NuMI neutrino beam facility at Fermilab to monitor the position and intensity of the hadron and muon beams downstream of the decay volume. The paper describes the chambers' construction, calibration, and commissioning in the beam, providing a practical characterization of these secondary beam monitors used for neutrino production.
arXivarXiv · · July 26, 2006
0
48
Beam Test of a Segmented Foil SEM Grid
S.KoppD. IndurthyZ. PavlovichM. ProgaR. ZwaskaS. ChildressR. FordC. KendzioraT. KobilarcikC. MooreG. Tassotto
A prototype secondary-electron emission monitor (SEM) using a segmented grid of 5 µm Ti foils was tested in the 8 GeV proton line for MiniBooNE. Full signal collection required a bias voltage, with a stronger effect at higher beam intensity. Beam centroid and width resolutions were measured at beam widths of 3, 7, and 8 mm. Extrapolating to the NuMI beam (1 mm spot size) yields expected centroid and width resolutions of 20 µm and 25 µm, respectively.
arXivarXiv · · July 29, 2005
0
Segmented Foil SEM Grids at Fermilab
S. KoppD. IndurthyZ. PavlovichM. ProgaR. ZwaskaB.BallerS.ChildressR.FordD.HarrisC.KendzioraC.MooreG.Tassotto
Fermilab tested segmented Ti-foil grids (5 µm thick) as secondary-electron emission monitors for proton beams. The new design provides beam centroid position and beam width measurements, with data reported on their precision and on beam loss caused by the foil material inserted into the beam.
arXivarXiv · · June 27, 2005
0
Ion Chamber Arrays for the Numi Beam at Fermilab
D.IndurthyZ.PavlovicR.ZwaskaR.KeislerS.MendozaS.KoppM.ProgaD.HarrisA.MarchionniJ.MorfinA.ErwinH.Ping  +7
This paper describes the construction and deployment of four arrays of ionization chambers at the NuMI beamline at Fermilab. Positioned downstream of the decay volume, these arrays monitor the neutrino beam direction and quality by measuring the remnant hadron beam and tertiary muons produced alongside neutrinos in meson decays. The goal is to characterize the intense muon neutrino beam for the NuMI experiment.
arXivarXiv · · June 26, 2005
0
5
Study of Neutron-Induced Ionization in Helium and Argon Chamber Gases
D.IndurthyA.R.ErwinD.HarrisS.KoppM.ProgaR.M.Zwaska
This paper reports measurements of neutron-induced ionization in helium and argon chamber gases, motivated by backgrounds in NuMI beamline ion chambers. Using PuBe neutron sources ($E_n=1-10$ MeV, $\sim10^8$ n/s), the authors derive the number of ion pairs per incident neutron in each gas. Despite limited precision from a large gamma background, the results are consistent with purely elastic neutron interactions in the chamber gas.
arXivarXiv · · May 5, 2004
0
Profile Monitor SEM's for the NuMI Beam at FNAL
D.IndurthyS.KoppZ.PavlovichM.Proga
Secondary emission monitors (SEMs) are designed for the NuMI beam line at FNAL to measure 120 GeV proton beam profiles and halo. Each SEM uses 5 µm titanium foils segmented into 1 mm or 0.5 mm pitch strips, causing a beam loss of ~5 × 10⁻⁶. The paper covers mechanical design, expected beam heating, and results from an 8 GeV test beam at FNAL.
arXivarXiv · · May 5, 2004
0
Ion Chambers for Monitoring the NuMI Neutrino Beam at FNAL
D.IndurthyR.KeislerS.KoppS.MendozaM. ProgaZ.PavlovichR.ZwaskaD.HarrisA.MarchionniJ.MorfinA.ErwinH.Ping  +6
This paper describes ionization-chamber arrays built for the NuMI beamline at FNAL, which produces a muon neutrino beam directed at the Soudan Underground Laboratory. Four arrays downstream of the decay volume measure the remnant hadron beam and tertiary muons from meson decays, providing information to steer the neutrino beam with 1 mRad angular accuracy. The paper covers chamber construction, radiation damage testing, calibration, and test beam results alongside the intended beam-quality monitoring application.
arXivarXiv · · May 5, 2004
0
0
Frequent collaborators
R. Zwaska (5)
S.Kopp (5)
S. Kopp (4)
M. Proga (4)
D.Harris (4)
M. Bishai (3)
S. Childress (3)
A. Marchionni (3)
Z. Pavlovic (3)
B. Viren (3)
M.Proga (3)
R. Ford (2)