MCP
DN

D. Northacker

25 papers in the library

Papers

25
The NOvA Test Beam Experiment
NOvA CollaborationS. Abubakar…D. Northacker
The NOvA Test Beam experiment collected data from 2019 to 2022 using a 30-ton detector identical to NOvA's main detectors, exposed to tagged electrons, muons, pions, kaons, and protons (0.4–1.5 GeV/c) from p-Cu collisions. Its central contribution is characterizing the detector response, energy calibration, and hadronic/electromagnetic energy resolutions, thereby addressing the largest systematic uncertainties in NOvA's neutrino oscillation measurements.
arXivarXiv · · September 9, 2026
0
0
Shower Separation in Five Dimensions for Highly Granular Calorimeters using Machine Learning
S. LaiJ. Utehs…D. Northacker
This paper evaluates three neural-network-based shower separation models for the CALICE AHCAL highly granular calorimeter prototype, targeting the Particle Flow goal of distinguishing energy deposits from charged and neutral hadrons. The best-performing model achieved significantly superior event reconstruction when timing information from AHCAL was included in training, for the case where the charged hadron was more energetic than the neutral one. This result motivates the development of temporally sensitive calorimeters. A consistent bias was observed: all models tended to allocate energy from the more energetic shower to the less energetic one.
arXivarXiv · · June 28, 2024
0
2
Particle Identification Using Boosted Decision Trees in the Semi-Digital Hadronic Calorimeter Prototype
D. BoumedieneA. PingaultM. TytgatB. BilkiD. NorthackerY. OnelG. ChoD-W. KimS. C. LeeW. ParkS. VallecorsaY. Deguchi  +78
The CALICE SDHCAL prototype, a high-granularity calorimeter for future leptonic colliders, was exposed to hadron, electron, and muon beams at CERN. This work introduces a particle identification method based on Boosted Decision Trees (BDT) for the SDHCAL. The method's performance is evaluated using both Geant4 simulations and data collected in 2015 across 10–80 GeV. The BDT method is applied to reject electron and muon contamination in SPS hadron beams.
arXivarXiv · · April 6, 2020
0
7
Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models
CALICE CollaborationM. Chefdeville…D. Northacker
This paper reports on the response of the highly granular Fe-DHCAL, a digital hadron calorimeter with steel absorbers and RPC active layers, to positrons, muons, and pions (2–60 GeV/c). Using testbeam data from Fermilab (2010–11), the study measures calorimeter response, energy resolution, and shower shapes. These measurements are compared with Geant4 simulations employing different physics lists, providing validation of the Monte Carlo models for this $1\times1$ cm$^2$ granularity, 38-layer, 350,208-channel digital calorimeter.
arXivarXiv · · January 25, 2019
0
28
Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter
CALICE collaborationJ. Repond…D. Northacker
A highly granular electromagnetic calorimeter prototype using 2160 individually read out scintillator strips ($10 \times 45 \times 3$ mm$^3$) was constructed and tested with 2-32 GeV electrons at Fermilab. The device achieved a deviation from linear energy response below 1.1% and an intrinsic energy resolution of $(12.5 \pm 0.1 \pm 0.4)\% / \sqrt{E[\mathrm{GeV}]} \oplus (1.2 \pm 0.1^{+0.6}_{-0.7})\%$, demonstrating performance suitable for future lepton collider experiments.
arXivarXiv · · July 22, 2017
0
19
Beam tests of an integrated prototype of the ATLAS Forward Proton detector
J. LangeL. Adamczyk…D. Northacker
The ATLAS Forward Proton (AFP) detector, combining 3D silicon pixel tracking and Quartz-Cherenkov time-of-flight (ToF) sub-detectors, was tested as an integrated prototype at the CERN-SPS test-beam facility in 2014-2015. The central contribution is the demonstration of successful tracking-timing integration with measured performance: the tracker achieved hit efficiencies above 99.9% at a 14° sensor tilt, a spatial resolution of $5.5 \pm 0.5\,\mu$m per pixel plane (50 µm pitch) and $2.8 \pm 0.5\,\mu$m for the full four-plane tracker, surpassing the AFP requirement of 10 µm. The ToF prototype, with two quartz bars, showed a full-system time resolution of $35 \pm 6$ ps, meeting initial low-luminosity requirements.
arXivarXiv · · August 4, 2016
0
Resistive Plate Chamber Digitization in a Hadronic Shower Environment
Z.DengY.Li…D.Northacker
For the CALICE Semi-Digital Hadron Calorimeter prototype using Glass Resistive Plate Chambers with three-threshold readout, the SimDigital algorithm digitizes GEANT4 simulated hits into detector signals. Its parameters are determined from muon tracks and electromagnetic showers. Comparisons with hadronic shower data show good agreement up to 50 GeV; discrepancies at higher energies are investigated.
arXivarXiv · · April 15, 2016
0
19
DHCAL with Minimal Absorber: Measurements with Positrons
CALICE CollaborationB. Freund…D. Northacker
The CALICE DHCAL prototype was tested with absorber plates removed, exposing its active layers directly to low-energy positron beams. Each layer had a thickness of about 0.29 radiation lengths. Measurements were taken with 1 to 10 GeV positrons at Fermilab. The results are compared to simulations using GEANT4 and a custom program that models the detailed response of the active elements.
arXivarXiv · · March 4, 2016
0
17
Design, Construction and Commissioning of the Digital Hadron Calorimeter - DHCAL
C. AdamsA. Bambaugh…D. Northacker
The paper reports on the design, construction, and commissioning of a large-scale prototype digital hadron calorimeter (DHCAL) for future lepton colliders. The calorimeter uses Resistive Plate Chambers with 1 x 1 cm² cells and a one-bit digital readout, optimized for Particle Flow Algorithms. Energy reconstruction is proportional to the number of pads above threshold. The prototype, with about 500,000 readout channels, was tested at Fermilab and CERN.
arXivarXiv · · March 4, 2016
0
33
Design, Construction and Testing of the Digital Hadron Calorimeter (DHCAL) Electronics
C. AdamsA. Bambaugh…D. Northacker
This paper reports on the design, construction, and commissioning of the electronic readout system for a large-scale Digital Hadron Calorimeter (DHCAL) prototype with approximately 500,000 channels. The system uses the DCAL front-end chip for one-bit digital readout of Resistive Plate Chambers (RPCs) with 1×1 cm² cells, and a VME-based back-end. The prototype underwent extensive testing at Fermilab and CERN test beams.
arXivarXiv · · March 4, 2016
0
3
Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
CALICE CollaborationG. Eigen…D. Northacker
Using test beam data from the CALICE scintillator-steel analogue hadron calorimeter, the study parametrises the longitudinal and radial development of hadron showers initiated by positive pions and protons (10–80 GeV/c) with two-component functions. The parametrisation is fitted to data and Geant4 simulations (QGSP_BERT and FTFP_BERT). The extracted parameters are compared for the two hadron types, and the response to pions and the ratio h/e are estimated from the longitudinal profile decomposition.
arXivarXiv · · February 27, 2016
0
18
First results of the CALICE SDHCAL technological prototype
V. BuridonC. Combaret…D. Northacker
The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) technological prototype, built in 2011 and tested at CERN SPS in 2012, demonstrates a linear response (within 5%) and good energy resolution for hadrons from 5 to 80 GeV. With 48 layers of Glass Resistive Plate Chambers operated in triggerless and power-pulsing mode, it achieves over 90% efficiency. The Semi-Digital mode improves performance at energies above 30 GeV over the Digital mode.
arXivarXiv · · February 6, 2016
0
92
An Upgrade Proposal from the PHENIX Collaboration
A. AdareS. Afanasiev…D. Northacker
The PHENIX collaboration proposes the sPHENIX upgrade to study the strongly coupled quark-gluon plasma (QGP) discovered at RHIC. The upgrade enables a jet and beauty quarkonia physics program to investigate how QCD, an asymptotically free theory, produces a near-perfect fluid with shear viscosity near $T_C$ as low as the uncertainty principle allows, an emergent property fundamental to understanding confinement.
arXivarXiv · · January 25, 2015
0
61
Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter
CALICE CollaborationB. Bilki…D. Northacker
The paper reports a study of positive hadron showers in the CALICE scintillator-steel analogue hadron calorimeter using test-beam data at 10–80 GeV/c. It compares the calorimeter response, energy resolution, and spatial shower development for proton- and pion-induced showers, and contrasts these measurements with Geant4 version 9.6 simulations. The central contribution is a systematic experimental characterization of the differences between pion and proton showers in this highly granular detector, providing data for validating hadronic shower models.
arXivarXiv · · December 8, 2014
0
27
Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter
CALICE CollaborationB. Bilki…D. Northacker
The paper reports a test of hadronic interaction models using 2–10 GeV negatively charged pion events recorded by the CALICE highly granular silicon-tungsten calorimeter. Geant4-based Monte Carlo predictions are compared to approximately 350,000 selected events. Overall, the models describe the data within 20%, with many observables matching more closely. The largest discrepancies are in the longitudinal and transverse distributions of reconstructed energy, highlighting specific areas where the models need improvement.
arXivarXiv · · November 26, 2014
0
34
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
C. AdloffJ.-J. Blaising…D. Northacker
The CALICE T3B experiment measures the intrinsic time structure of hadronic showers in sampling calorimeters with tungsten and steel absorbers using 15 plastic scintillator tiles read out by Silicon Photomultipliers, providing high spatial and temporal resolution on a statistical basis. Comparisons with GEANT4 (version 9.4 patch 03) simulations show that for tungsten absorbers, high-precision treatment of low-energy neutrons is crucial for accurate modeling, whereas for steel, all considered hadronic physics models achieve good agreement with data.
arXivarXiv · · April 25, 2014
0
30
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
CALICE CollaborationK. Francis…D. Northacker
This paper presents the performance of the first prototype of a scintillator strip electromagnetic calorimeter built for future linear collider experiments. The prototype, comprising 26 tungsten absorber layers interleaved with plastic scintillator strips, was tested with a positron beam of 1–6 GeV/c. The energy measurement linearity and resolution are reported, marking an important milestone for highly granular calorimeters based on scintillator strip technology, which aim to enable precise jet energy measurements via particle flow techniques.
arXivarXiv · · November 15, 2013
0
43
Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL
C. AdloffJ.-J. Blaising…D. Northacker
The paper reports on the performance of a fine-grained hadron sampling calorimeter prototype with tungsten absorber plates and scintillator tiles read out by silicon photomultipliers, built for the proposed CLIC $e^+e^-$ collider. Using particle beams of electrons, pions, and protons with momenta from 1 to 10 GeV, the study presents energy resolution and shower shape measurements. The results are compared with multiple GEANT4 simulation models to evaluate the reliability of Monte Carlo predictions for a future CLIC experiment.
arXivarXiv · · November 14, 2013
0
47
sPHENIX: An Upgrade Concept from the PHENIX Collaboration
A. AdareC. Aidala…D. Northacker
The PHENIX collaboration proposes sPHENIX, a major detector upgrade at RHIC, to enable a jet physics program addressing fundamental questions about the strongly coupled quark-gluon plasma (sQGP) discovered at RHIC to be a perfect fluid. The upgrade fully utilizes the recently upgraded RHIC luminosity to study how to reconcile the sQGP with asymptotic freedom, the dynamical changes of the plasma with temperature, and the sharpness of the transition from the strongly coupled regime to weakly coupled partons. Three appendices describe additional physics capabilities from further detector additions and upgrades.
arXivarXiv · · July 26, 2012
0
38
The T2K Side Muon Range Detector
S. AokiG. Barr…D. Northacker
The T2K experiment's Side Muon Range Detector (SMRD), the outermost component of the ND280 near detector, is described. The SMRD consists of scintillation counters with embedded wavelength shifting fibers and Multi-Pixel Photon Counter readout. Its components, performance, and response are presented, contributing to the measurement of the un-oscillated neutrino flux and neutrino cross sections in the T2K long baseline neutrino oscillation experiment.
arXivarXiv · · June 15, 2012
0
Scintillator counters with WLS fiber/MPPC readout for the side muon range detector (SMRD)of the T2K experiment
A. IzmaylovS. Aoki…D. Northacker
The T2K experiment's side muon range detector uses 0.7 cm thick extruded scintillator slabs inserted into UA1 magnet yokes, each read out by a single serpentine-shaped WLS fiber coupled to two Hamamatsu MPPCs at both ends. This design achieves a MIP detection efficiency above 99%, with a light yield of 25–50 p.e./MIP, time resolution of about 1 ns, and spatial resolution better than 10 cm along the slab.
arXivarXiv · · April 29, 2009
0
26
Calibration of a digital hadron calorimeter with muons
B.BilkiJ.Butler…D.Northacker
This paper presents a calibration method for a finely segmented digital hadron calorimeter that uses Resistive Plate Chambers as its active elements. The procedure is validated with data from a nine-layer stack exposed to muons at the Fermilab test beam.
arXivarXiv · · February 22, 2008
0
63
Secondary Beam Monitors for the NuMI Facility at FNAL
S. KoppM. Bishai…D. Northacker
Four arrays of ionization chambers were built for the NuMI neutrino beam facility at Fermilab to monitor the position and intensity of the hadron and muon beams downstream of the decay volume. The paper describes the chambers' construction, calibration, and commissioning in the beam, providing a practical characterization of these secondary beam monitors used for neutrino production.
arXivarXiv · · July 26, 2006
0
48
Ion Chamber Arrays for the Numi Beam at Fermilab
D.IndurthyZ.Pavlovic…D.Northacker
This paper describes the construction and deployment of four arrays of ionization chambers at the NuMI beamline at Fermilab. Positioned downstream of the decay volume, these arrays monitor the neutrino beam direction and quality by measuring the remnant hadron beam and tertiary muons produced alongside neutrinos in meson decays. The goal is to characterize the intense muon neutrino beam for the NuMI experiment.
arXivarXiv · · June 26, 2005
0
5
Ion Chambers for Monitoring the NuMI Neutrino Beam at FNAL
D.IndurthyR.Keisler…D.Northacker
This paper describes ionization-chamber arrays built for the NuMI beamline at FNAL, which produces a muon neutrino beam directed at the Soudan Underground Laboratory. Four arrays downstream of the decay volume measure the remnant hadron beam and tertiary muons from meson decays, providing information to steer the neutrino beam with 1 mRad angular accuracy. The paper covers chamber construction, radiation damage testing, calibration, and test beam results alongside the intended beam-quality monitoring application.
arXivarXiv · · May 5, 2004
0
0
Frequent collaborators
Y. Onel (15)
B. Bilki (14)
J. Kvasnicka (12)
F. Richard (12)
F. Simon (12)
V. Vrba (12)
J. Zalesak (11)
K. Gadow (11)
S. Lu (11)
M. Reinecke (11)
F. Sefkow (11)
M. Danilov (11)