MCP
DC

DarkSide Collaboration

10 papers in the library

Papers

10
Separating 39^{39}Ar from 40^{40}Ar by cryogenic distillation with Aria for dark matter searches
DarkSide CollaborationP. AgnesS. AlbergoI. F. M. AlbuquerqueT. AlexanderA. AliciA. K. AltonP. AmaudruzM. ArbaP. ArpaiaS. ArcelliM. Ave  +300
The Aria project deploys a 350 m cryogenic distillation column, the tallest ever built, to separate $^{39}$Ar from $^{40}$Ar for dark-matter searches. The plant reduces the isotopic abundance of $^{39}$Ar, a cosmogenic $\beta$-emitter whose activity causes background in argon detectors. The paper reports the column’s requirements, design, construction, tests, and projected performance, along with successful nitrogen distillation results from a prototype operated at total reflux.
arXivarXiv · · January 21, 2021
0
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
DarkSide CollaborationC. E. AalsethS. AbdelhakimF. AcerbiP. AgnesR. AjajI. F. M. AlbuquerqueT. AlexanderA. AliciA. K. AltonP. AmaudruzF. Ameli  +319
The DArT in ArDM experiment is a small, ultra-radio-pure detector designed to measure the $^{39}$Ar content of underground argon (UAr) for the DarkSide-20k dark matter search. It will be placed at the center of the ArDM detector, which acts as an active veto against background radioactivity. The article describes the chamber's design, construction, and background requirements needed to achieve the performance required for the Global Argon Dark Matter Collaboration.
arXivarXiv · · January 22, 2020
0
49
Low-Mass Dark Matter Search with the DarkSide-50 Experiment
DarkSide CollaborationP. AgnesI. F. M. AlbuquerqueT. AlexanderA. K. AltonG. R. AraujoD. M. AsnerM. AveH. O. BackB. BaldinG. BatignaniK. Biery  +183
DarkSide-50 searched for low-mass dark matter WIMPs below 20 GeV/c² using a low-radioactivity argon target. The analysis relied on the ionization signal, with full efficiency at 0.1 keVee. The observed rate at 0.5 keVee is about 1.5 events/keVee/kg/day, mostly from known backgrounds. The experiment set a 90% C.L. exclusion limit on the spin-independent WIMP-nucleon cross section above 1.8 GeV/c², extending the exclusion region below previous limits for 1.8–6 GeV/c².
arXivarXiv · · February 20, 2018
0
801
Constraints on Sub-GeV Dark Matter-Electron Scattering from the DarkSide-50 Experiment
DarkSide CollaborationP. AgnesI. F. M. AlbuquerqueT. AlexanderA. K. AltonG. R. AraujoD. M. AsnerM. AveH. O. BackB. BaldinG. BatignaniK. Biery  +184
Based on the DarkSide-50 experiment's argon detector, new constraints are placed on sub-GeV dark matter particles scattering off electrons. The analysis uses the detector's ionization signal data to set limits on the interaction cross-section for dark matter masses below 1 GeV.
arXivarXiv · · February 20, 2018
0
349
DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
DarkSide CollaborationP. AgnesI. F. M. AlbuquerqueT. AlexanderA. K. AltonG. R. AraujoM. AveH. O. BackB. BaldinG. BatignaniK. BieryV. Bocci  +163
The DarkSide-50 experiment, a dual-phase argon time projection chamber at Gran Sasso, performed a blind analysis of a 16,660 kg·d exposure using underground-sourced low-radioactivity argon. No events were observed in the dark matter selection box, yielding a 90% C.L. upper limit on the spin-independent WIMP-nucleon cross section of $1.14\times10^{-44}\,\text{cm}^2$ for a WIMP mass of $100\,\text{GeV}/c^2$.
arXivarXiv · · February 20, 2018
0
457
The Electronics, Trigger and Data Acquisition System for the Liquid Argon Time Projection Chamber of the DarkSide-50 Search for Dark Matter
DarkSide CollaborationP.AgnesI.F.M.AlbuquerqueT.AlexanderA.K.AltonK.ArisakaD.M.AsnerM.AveH.O.BackB.BaldinK.BieryV.Bocci  +168
The DarkSide-50 dark matter search uses a dual-phase liquid argon time projection chamber (TPC). This paper describes the electronics, trigger, and data acquisition system built for it. The system processes signals from 38 photo-multiplier tubes (PMTs) via custom pre-amplifiers immersed in liquid argon, room-temperature amplifier/discriminators, and CAEN waveform digitizers. CAEN logic modules construct the trigger, and the Fermilab "artdaq" software handles data acquisition. The system has been operational since early 2014.
arXivarXiv · · July 31, 2017
0
30
Simulation of argon response and light detection in the DarkSide-50 dual phase TPC
DarkSide CollaborationP. AgnesI. F. M. AlbuquerqueT. AlexanderA. K. AltonD. M. AsnerH. O. BackK. BieryV. BocciG. BonfiniW. BoniventoM. Bossa  +138
The G4DS Monte Carlo package simulates the response of the DarkSide-50 dual-phase TPC, focusing on liquid argon scintillation, ionization, and electron-ion recombination. The simulation accurately reproduces the detector's electron recoil rejection power of ~10^7 via pulse shape discrimination and the measured ~1000-fold reduction of 39Ar contamination in underground argon. The central component is PARIS, a custom liquid argon response model that underpins these key results.
arXivarXiv · · July 18, 2017
0
85
The veto system of the DarkSide-50 experiment
DarkSide CollaborationP. AgnesL. AgostinoI. F. M. AlbuquerqueT. AlexanderA. K. AltonK. ArisakaH. O. BackB. BaldinK. BieryG. BonfiniM. Bossa  +149
The DarkSide-50 experiment uses a neutron veto system to suppress and measure neutron-induced backgrounds that mimic WIMP signals. The veto consists of a boron-loaded liquid scintillator detector inside a water Cherenkov detector. This paper describes the veto's detector structure, event reconstruction and data analysis fundamentals, and basic performance parameters.
arXivarXiv · · December 24, 2015
0
94
Results from the first use of low radioactivity argon in a dark matter search
DarkSide CollaborationP. AgnesL. AgostinoI. F. M. AlbuquerqueT. AlexanderA. K. AltonK. ArisakaH. O. BackB. BaldinK. BieryG. BonfiniM. Bossa  +149
DarkSide-50 reports the first WIMP search using low-radioactivity underground argon as the target. The argon contains $^{39}$Ar at a level reduced by a factor of $(1.4 \pm 0.2) \times 10^3$ relative to atmospheric argon. Based on 2616 kg·d of exposure, a background-free null result is obtained. Combining with previous atmospheric-argon data gives a 90% C.L. upper limit on the spin-independent WIMP-nucleon cross section of $2.0 \times 10^{-44}\,\text{cm}^2$ for a WIMP mass of 100 GeV/$c^2$.
arXivarXiv · · October 2, 2015
0
337
The Electronics and Data Acquisition System of the DarkSide Dark Matter Search
DarkSide CollaborationP. AgnesT. AlexanderA. AltonK. ArisakaH. O. BackB. BaldinK. BieryG. BonfiniM. BossaA. BrigattiJ. Brodsky  +134
The DarkSide-50 experiment searches for Weakly Interacting Massive Particle (WIMP) dark matter by detecting nuclear recoils in a liquid argon time projection chamber (TPC), nested inside a liquid scintillator veto and a water veto. This paper describes the electronics and data acquisition system that reads out the TPC and veto detectors, capturing residual ionization signals from potential WIMP-nuclear collisions with the required sensitivity and timing resolution.
arXivarXiv · · December 9, 2014
0
4
Frequent collaborators
P. Agnes (9)
T. Alexander (9)
H. O. Back (9)
N. Canci (9)
P. Cavalcante (9)
A. Chepurnov (9)
A. Devoto (9)
F. Di Eusanio (9)
G. Fiorillo (9)
D. Franco (9)
F. Gabriele (9)
C. Galbiati (9)