MCP
EB

E. Brown

77 papers in the library · Same-name authors told apart using DBLP

Papers

30
Simulation and Rejection of Radon Progeny Backgrounds in nEXO
M. P. WattsB. T. Foust…E. Brown
This simulation-based study of nEXO addresses $^{214}$Bi backgrounds from implanted radon progeny, using a physically motivated model of progeny transport and implantation at the cathode. Its central result is that the spatial distribution of scintillation light discriminates events surviving standard energy, topology, and fiducial-volume cuts: a simple discriminator on light detected below the cathode rejects 41% of remaining $^{214}$Bi backgrounds at 95% $0\nu\beta\beta$ signal efficiency, and a convolutional neural network raises this to 57%. An updated optical model also increases the expected Bi-Po coincidence-tagging efficiency for bottom-surface $^{214}$Bi decays from below 1% to about 50%.
arXivarXiv · · November 22, 2026
0
Estimating cosmogenic backgrounds in nEXO at SNOLAB using Geant4 and FLUKA
R. RossS. Al Kharusi…E. Brown
The nEXO experiment searches for neutrinoless double beta decay in $^{136}$Xe using a five-tonne liquid xenon TPC. This paper estimates its cosmogenic background rate at the underground SNOLAB site, comparing Geant4 and FLUKA Monte Carlo simulations of muon-induced spallation and neutron reactions. Only $^{137}$Xe, from neutron capture on xenon, is concerning. The authors devise a veto strategy achieving 92% rejection of $^{137}$Xe with under 1 day dead time per 10 years.
arXivarXiv · · October 31, 2026
0
0
The nEXO Radioassay Program
R. MacLellanP. Acharya…E. Brown
The nEXO Radioassay Program provides a compilation of radioactivity constraints for materials of interest to low-background experiments. Using several assay techniques, this work reports among the most restrictive limits on natural radioactivity content for materials relevant to the planned nEXO double-beta decay search. This data helps researchers select radiopure materials, saving time and reducing duplication of effort in rare-event search experiments.
arXivarXiv · · April 16, 2026
0
1
Design of a high voltage delivery system for noble liquid time projection chambers
R. SaldanhaL. Pagani…E. Brown
This paper presents a high voltage (HV) delivery system for noble liquid time projection chambers (TPCs), specifically designed for the nEXO neutrinoless double beta decay experiment. Building on prior HV research and experimental investigations, the authors identify factors that influence HV stability and propose design choices to prevent electrical discharges. The novel system incorporates these stability-enhancing measures while meeting nEXO's stringent radiopurity requirements, offering a practical design framework for future noble-liquid HV applications.
arXivarXiv · · February 27, 2026
0
1
Characterization of CRYO ASIC for charge readout in the nEXO experiment
Z. LiM. Yu…E. Brown
This work characterizes the CRYO ASIC, a cryogenic charge-readout chip designed to operate directly in liquid xenon (LXe) for the nEXO neutrinoless double beta decay experiment, thereby minimizing input capacitance and pick-up noise. Tested on an auxiliary printed circuit board in a cryogenic chamber and a dedicated LXe test stand, the ASICs achieved the desired performance at LXe temperatures, with gain stability better than 0.2% over 24-hour operation and reliable in-situ calibration via an on-chip pulser. Boiling from chip heat dissipation was mitigated by operating above ~0.1 MPa, and measured in-LXe noise agreed with simulation, indicating the $150~e^-$ design requirement can be met, establishing the CRYO ASIC as a viable low-noise in-LXe solution for nEXO.
arXivarXiv · · December 11, 2025
0
1
From Commissioning to Precision Data-Taking: Resolving Operational Challenges in the Nab Detector Systems
L. J. BroussardH. AcharyaR. AlarconS. BaeßlerM. BenoitK. BorahC. L. BrittonE. BrownJ. ChoiS. ClymerC. CrawfordN. Ericson  +27
The Nab experiment at the Spallation Neutron Source aims to resolve the CKM unitarity anomaly by precisely extracting $V_{ud}$ via the electron-neutrino correlation coefficient in neutron beta decay, using an asymmetric spectrometer for coincident proton and electron energy reconstruction. Recent upgrades to the detector system have improved proton detection efficiency, noise performance, and segment availability, enabling high-precision data-taking for a first full momentum phase-space observation of the decay above detector thresholds, with implications for exotic neutron states.
arXivarXiv · · November 10, 2025
0
0
Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments
T. J. RoosendaalC. T. Overman…E. Brown
This paper evaluates chemical vapor deposition (CVD) nickel as a structural material for low-radioactivity instruments. CVD Ni achieves a planar tensile strength of ~600 MPa, significantly higher than standard nickel, and record-low bulk contaminations of $^{232}\\mathrm{Th}$ (~70 ppq), $^{238}\\mathrm{U}$ (<100 ppq), and $^{\\mathrm{nat}}\\mathrm{K}$ (~900 ppt). However, welding and heat treatment reduce strength to standard Ni levels, with weld porosity as a likely cause. Surface-etch profiling reveals higher contamination extending ~10 $\\mu$m below the surface from the aluminum substrate. These results establish CVD Ni as promising while highlighting needed improvements in welding and surface cleaning for rare-event search experiments.
arXivarXiv · · August 11, 2025
0
3
Sensitivity of nEXO to 136^{136}Xe Charged-Current Interactions: Background-free Searches for Solar Neutrinos and Fermionic Dark Matter
G. RichardsonB. G. Lenardo…E. Brown
nEXO's sensitivity to charged-current interactions of $\nu_e$ or fermionic dark matter with $^{136}$Xe is studied, exploiting a time-delayed coincident signal in the scintillation channel from low-lying isomeric states of $^{136}$Cs. A detailed Monte Carlo simulation shows that correlated signal can achieve background discrimination of $10^{-9}$, enabling background-free solar neutrino measurements above 0.668 MeV. nEXO could measure the CNO neutrino flux with 25% statistical uncertainty, constrain $^7$Be neutrino mean energy to $\sigma\leq1.5$ keV, and probe dark matter masses $m_\chi=0.668$-$7$ MeV with sensitivity up to three orders of magnitude better than current limits.
arXivarXiv · · June 27, 2025
0
3
Prototyping and Test of the "Canis" HTS Planar Coil Array for Stellarator Field Shaping
D. NashD.A. Gates…E. Brown
Thea Energy designed, built, and tested the "Canis" 3×3 array of high-temperature superconductor (HTS) planar shaping coils to demonstrate the field-shaping approach for the "Eos" planar coil stellarator. Operated at 20 K, the array generated stellarator-relevant magnetic field shapes and achieved closed-loop field control within 1% of the predicted field, a margin acceptable for an integrated stellarator. This test campaign provides a proof of concept that HTS planar coils can produce the magnetic fields needed to confine stellarator plasmas without complex modular coils.
arXivarXiv · · March 19, 2025
0
8
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a 136^{136}Xe double beta decay experiment
M. YvaineD. Fairbank…E. Brown
This work extends single-atom barium imaging in solid xenon, relevant for $^{136}$Xe neutrinoless double-beta-decay background rejection, by detecting Ba atoms occupying a hexa-vacancy matrix site. Despite increased photobleaching at this site, imaging is achieved. The study observes abrupt fluorescence turn-off in single Ba atoms and demonstrates significant fluorescence recovery upon annealing of Ba deposits. Post-annealing, hexa-vacancy Ba atoms exhibit antibleaching while tetra-vacancy Ba atoms show bleaching, suggesting laser-induced matrix site transfer. These findings advance barium tagging across all relevant sites in solid xenon.
arXivarXiv · · June 29, 2024
0
0
Neutrinoless Double Beta Decay
C. AdamsK. Alfonso…E. Brown
This White Paper, prepared for the 2023 Nuclear Physics Long Range Plan, argues that neutrinoless double beta decay experiments are a critical component of the future nuclear physics program. It is endorsed by the major experimental collaborations and many theorists, establishing community consensus on the priority of this physics search.
arXivarXiv · · December 21, 2022
0
36
A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
M. SzydagisJ. BalajthyG.A. BlockJ.P. BrodskyE. BrownJ.E. CutterS.J. FarrellJ. HuangA.C. KamahaE.S. KozlovaC.S. LiebenthalD.N. McKinsey  +14
This review presents the Noble Element Simulation Technique (NEST) for liquid xenon detectors, a toolkit that uses experimental data and empirical formulae to model scintillation and ionization yields as functions of particle type, energy, and electric field. NEST outputs are compared against other models and validated with data from XENON, LUX, LZ, and other experiments, making it a central reference for simulating detector responses in rare-event searches.
arXivarXiv · · November 19, 2022
0
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
J. AalbersK. Abe…E. Brown
This review article argues that a next-generation dual-phase xenon time-projection chamber will serve as a multi-purpose observatory, advancing dark matter and neutrino physics. It is the leading technology for probing Weakly Interacting Massive Particles (WIMPs) and other dark matter candidates, while also enabling studies of neutrinoless double-beta decay and astrophysical neutrinos. The paper presents the science cases for such a detector, highlighting its potential contributions to particle physics, nuclear physics, astrophysics, solar physics, and cosmology.
arXivarXiv · · March 4, 2022
1
255
Development of a 127^{127}Xe calibration source for nEXO
B. G. LenardoC. A. Hardy…E. Brown
The authors propose a $^{127}$Xe electron capture source for in-situ calibration of the nEXO experiment, which searches for neutrinoless double beta decay ($0\nu\beta\beta$) using a 5-tonne liquid xenon TPC. With a 36.3-day half-life and a small $Q$-value, $^{127}$Xe can be maintained continuously in the detector without adding backgrounds, enabling calibration of position- and time-dependent response. The work describes source production, preliminary tests, and simulations projecting the precision of spatial corrections to light and charge response.
arXivarXiv · · January 12, 2022
0
8
NEXO: Neutrinoless double beta decay search beyond 102810^{28} year half-life sensitivity
nEXO CollaborationG. Adhikari…E. Brown
The nEXO experiment, using a time projection chamber with 5000 kg of enriched liquid xenon, targets neutrinoless double beta decay in $^{136}$Xe. Updated detector design, higher-fidelity simulation, and advanced analysis based on EXO-200 yield a predicted half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level over 10 years, covering the inverted neutrino mass ordering parameter space and most of the normal ordering for nearly all nuclear matrix elements. The design incorporates custom electroformed copper to reduce material backgrounds, and the model is robust against several background deviations.
arXivarXiv · · June 30, 2021
0
388
Search for Coherent Elastic Scattering of Solar 8^8B Neutrinos in the XENON1T Dark Matter Experiment
E. AprileJ. Aalbers…E. Brown
The XENON1T experiment searches for coherent elastic scattering of solar $^8$B neutrinos off xenon nuclei by lowering its energy threshold from 2.6 to 1.6 keV. No significant excess is found in 0.6 t$\times$y exposure, setting new constraints on the light yield of 1–2 keV nuclear recoils and on non-standard neutrino-quark interactions. The result also improves world-leading limits on dark matter–nucleus interactions for masses between 3 and 11 GeV/c$^2$ by up to an order of magnitude.
arXivarXiv · · December 4, 2020
0
Search for inelastic scattering of WIMP dark matter in XENON1T
XENON CollaborationE. Aprile…E. Brown
Using 0.89 tonne-years of XENON1T data, a search for inelastic WIMP scattering off $^{129}$Xe found no evidence above 2$\sigma$. The characteristic 39.6 keV de-excitation photon was required in coincidence with the nuclear recoil. A profile-likelihood ratio analysis set a 90% CL upper limit of $3.3 \times 10^{-39}$ cm$^2$ for 130 GeV/c$^2$ WIMPs, excluding new parameter space for WIMPs heavier than 100 GeV/c$^2$.
arXivarXiv · · November 20, 2020
0
59
222^{222}Rn emanation measurements for the XENON1T experiment
E. AprileJ. Aalbers…E. Brown
For the XENON1T dark matter experiment, $^{222}$Rn emanation from material surfaces was measured to select low-radioactivity construction materials. The emanation measurements, combined with bulk impurity screening, guided the elimination of critical components, targeting a $^{222}$Rn activity concentration of 10 $\mu$Bq/kg in 3.2 t of xenon. The final measured concentration of (4.5 $\pm$ 0.1) $\mu$Bq/kg is the lowest ever achieved in a xenon dark matter experiment.
arXivarXiv · · September 29, 2020
0
0
Excess Electronic Recoil Events in XENON1T
E. AprileJ. Aalbers…E. Brown
The XENON1T experiment observed an excess of low-energy electronic recoil events between 2 and 3 keV above known backgrounds. The excess is consistent with solar axions (3.4σ), an enhanced neutrino magnetic moment (3.2σ), or tritium β decays (3.2σ). However, solar axion and neutrino magnetic moment interpretations are in strong tension with stellar constraints, and the tritium hypothesis cannot be confirmed or excluded. If an unconstrained tritium component is included, the significance of solar axion and neutrino magnetic moment hypotheses reduces to 2.0σ and 0.9σ, respectively. The excess is also compatible with a 2.3 keV monoenergetic peak from bosonic dark matter (3.0σ global significance).
arXivarXiv · · June 17, 2020
1
735
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
P. LvG.F. Cao…E. Brown
This paper reports the angular and spectral dependence of specular reflectance of SiPMs from FBK and Hamamatsu in the 120 nm–280 nm vacuum ultraviolet range. The refractive index and extinction coefficient of the SiO₂ film on FBK SiPMs are derived from reflectance measurements of a reference wafer. Diffuse reflectance at 193 nm is also measured. The optical constants are used to predict reflectance in liquid xenon, which is relevant for large-scale photodetector systems.
arXivarXiv · · December 4, 2019
0
24
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
O. NjoyaT. Tsang…E. Brown
The authors report measurements of electron drift properties in liquid and gaseous xenon. Using a laser-driven gold photocathode in a small chamber with a 2.0 cm drift distance, they measure drift velocities and longitudinal diffusion coefficients. At 0.5 kV/cm, the drift velocity in liquid xenon is $1.97 \pm 0.04$ mm/$\mu$s with a temperature coefficient of $(-0.69\pm0.05)$\%/K; in gaseous xenon at 1.5 bar, it is $1.42 \pm 0.03$ mm/$\mu$s with $(+0.11\pm0.01)$\%/K. Diffusion coefficients are $25.7 \pm 4.6$ cm$^2$/s (liquid) and $149 \pm 23$ cm$^2$/s (gas). The photocathode's quantum efficiency is also studied.
arXivarXiv · · November 25, 2019
0
34
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
P. NakarmiI. Ostrovskiy…E. Brown
This paper reports the first measurement of specular reflectivity and relative photodetection efficiency (PDE) of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μm micro-cells in liquid xenon using xenon scintillation light (~175 nm). At 15° incidence, specular reflectivity of three samples is 30.4±1.4%, 28.6±1.3%, and 28.0±1.3%, respectively. PDE at normal incidence varies by ±8% (standard deviation) among devices. Both reflectivity and PDE decrease with increasing incidence angle.
arXivarXiv · · October 14, 2019
0
32
Search for Light Dark Matter Interactions Enhanced by the Migdal effect or Bremsstrahlung in XENON1T
E. AprileJ. Aalbers…E. Brown
This paper searches for low-mass dark matter (down to ~85 MeV/c²) using XENON1T data. Standard elastic-scattering searches lose sensitivity below ~5 GeV/c² due to small momentum transfer. The authors instead target electronic recoils from the Migdal effect (atomic excitation/ionization) and Bremsstrahlung that inevitably accompany elastic scattering. They use both the standard scintillation+ionization method and a novel ionization-only approach for a lower threshold, significantly extending XENON1T's reach to lighter dark matter.
arXivarXiv · · July 30, 2019
0
449
Light Dark Matter Search with Ionization Signals in XENON1T
E. AprileJ. Aalbers…E. Brown
Using only ionization signals in XENON1T, we set constraints on light dark matter models. By selecting events without requiring a scintillation signal, we achieve an effective exposure of $(22 \pm 3)$ tonne-days and a background rate above $\sim\!0.4\,\mathrm{keV}_\mathrm{ee}$ below $1$ event/(tonne$\times$day$\times$keV$\_\mathrm{ee}$). While unexplained low-energy excess prevents a DM or CEvNS detection claim, we exclude new parameter space for DM-nucleus scattering with $m_\chi$ in $3-6\,\mathrm{GeV}/c^2$, DM-electron scattering for $m_\chi > 30\,\mathrm{MeV}/c^2$, and dark photon/axion-like particle absorption for $m_\chi$ in $0.186-1\,\mathrm{keV}/c^2$.
arXivarXiv · · July 26, 2019
0
875
Simulation of charge readout with segmented tiles in nEXO
Z. LiW.R. Cen…E. Brown
nEXO, a proposed tonne-scale liquid xenon TPC searching for $0\nu\beta\beta$ decay of $^{136}$Xe, uses segmented charge-collection tiles as its anode. A dedicated simulation shows that a multi-variate method and a deep neural network can distinguish signal from radioactive backgrounds. The estimated half-life sensitivity improves by $\sim$20\% with the multi-variate method and $\sim$32\% with the deep neural network, relative to the pre-conceptual design report.
arXivarXiv · · July 17, 2019
0
29
The XENON1T Data Acquisition System
E. AprileJ. Aalbers…E. Brown
The XENON1T data acquisition system (DAQ) digitizes signals from the most sensitive liquid xenon time projection chamber built for WIMP dark matter detection. Its central contribution is achieving a sub-tenth-of-photoelectron signal threshold via a parallelized readout that defers the global trigger to a software stage. Event identification, using MongoDB queries, exceeds 97% efficiency at the analysis energy threshold. The DAQ reaches over 300 MB/s readout bandwidth in calibration modes, expandable through parallelization, and was successfully used throughout XENON1T's three-year operation.
arXivarXiv · · June 3, 2019
0
43
First observation of two-neutrino double electron capture in 124^{124}Xe with XENON1T
E. AprileJ. Aalbers…E. Brown
The XENON1T dark matter detector reports the first direct observation of two-neutrino double electron capture in $^{124}$Xe, a second-order Weak process. The signal significance is $4.4\sigma$, yielding a half-life of $T_{1/2}^{2\nu\text{ECEC}} = (1.8\pm 0.5_\text{stat}\pm 0.1_\text{sys})\times 10^{22}\;\text{y}$, the longest ever measured directly. This result provides input for nuclear structure models and is a step toward searching for neutrinoless double electron capture, which would probe neutrino properties.
arXivarXiv · · April 24, 2019
0
Cylindrical Films for Electronics in Low Background Physics Searches
E. BrownK. OdgersM. GiordanoK. LewisT. BergerJ.Freedberg
This paper demonstrates a technique for manufacturing thin-film resistors on cylindrical substrates using electron beam deposition with substrate rotation, targeting low-background physics detectors. The cylindrical Ni films show anisotropic resistivity: ~888.5–1392.5 nΩ·m azimuthally and ~72.8–81.9 nΩ·m axially, measured via a modified Van Der Pauw method and electrostatic simulations. The anisotropy is not intrinsic to the deposition process, as planar samples made without rotation exhibit isotropic resistivity around 66–72 nΩ·m. Despite this, the cylindrical films are usable as resistors.
arXivarXiv · · March 8, 2019
0
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
G. GallinaP. Giampa…E. Brown
The Hamamatsu VUV4 MPPC was characterized for the nEXO experiment's liquid xenon scintillation detection. At 163 K and 3.1 V over voltage, correlated avalanches per pulse (0.161±0.005) and dark-noise rate (0.137 Hz/mm²) meet nEXO specifications. However, its photon detection efficiency at 189 nm and 233 K (13.4% and 11% for two devices) falls well below the advertised 24% saturation PDE, with the second device also below nEXO's requirement. The first device's PDE is marginally close, suggesting that modest improvements could make it a viable alternative to FBK-LF SiPMs.
arXivarXiv · · March 8, 2019
0
94
XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
E. AprileJ. Aalbers…E. Brown
This paper details the detector response, background/signal models, and statistical inference used in XENON1T's dark matter analysis with a 1 tonne×year exposure. The central contribution is the resulting best limit on the WIMP-nucleon spin-independent elastic scattering cross-section for WIMP masses above 6 GeV/c², achieved through the lowest background rate in a liquid xenon detector.
arXivarXiv · · February 28, 2019
0
Frequent collaborators
K. Ni (56)
L. Baudis (50)
H. Wang (48)
E. Aprile (48)
F. Arneodo (48)
M. Schumann (48)
P. Shagin (48)
G. Plante (47)
D. Thers (47)
C. Weinheimer (47)
U. Oberlack (47)
S. Lindemann (45)