MCP
EC

E. Cudmore

4 papers in the library

Papers

4
First demonstration of a TES based cryogenic Li2_2MoO4_4detector for neutrinoless double beta decay search
G. BratrudC. L. ChangR. ChenE. CudmoreE. Figueroa-FelicianoZ. HongK. T. KennardS. LewisM. LisovenkoL. O. MateoV. NovatiV. Novosad  +13
This paper presents a cryogenic Li$_2$MoO$_4$ detector for neutrinoless double-beta decay ($0\nu\beta\beta$) search that uses a low-impedance TES-based readout, replacing the conventional NTD thermistor. A 21$\,$g prototype achieves rise times of $\sim$0.5$\,$ms—more than an order of magnitude faster than NTD-based detectors—and a baseline energy resolution of 1.95$\,$keV (FWHM). These parameters extrapolate to a pile-up background index as low as $5\cdot 10^{-6}\,$counts/keV/kg/yr for CUPID-sized crystals, making the design suitable for future large-scale experiments like CUPID-1T.
arXivarXiv · · June 4, 2024
0
Modeling and characterization of TES-based detectors for the Ricochet experiment
R. ChenE. Figueroa-FelicianoG. BratrudC.L. ChangL. ChaplinskyE. CudmoreW. Van De PontseeleJ. A. FormaggioP. HarringtonS. A. HertelZ. HongK. T. Kennard  +17
The Ricochet experiment aims to measure coherent elastic neutrino-nucleus scattering (CE$\nu$NS) using an array of cryogenic thermal detectors read out by Transition-Edge Sensors (TES). This paper presents an updated characterization and modeling of a prototype TES detector, which has a mass of about 30 g and a sub-100 eV energy threshold, serving as a demonstrator for future neutrino experiments with thousands of detectors.
arXivarXiv · · November 21, 2023
0
2
First demonstration of 30 eVee ionization energy resolution with Ricochet germanium cryogenic bolometers
C. AugierG. Baulieu…E. Cudmore
The Ricochet experiment will search for new physics by measuring coherent elastic neutrino-nucleus scattering from reactor antineutrinos with sub-100 eV nuclear recoil sensitivity. This paper reports the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) using the CryoCube germanium cryogenic bolometer, coupled with a dedicated HEMT-based front-end. This resolution is an order of magnitude better than previous best results from EDELWEISS and SuperCDMS, and a factor of three better than the prior HEMT-based CDMS-II detector. The findings are discussed in the context of Ricochet's background mitigation goals.
arXivarXiv · · May 31, 2023
0
29
First ultracold neutrons produced at TRIUMF
S. AhmedE. AltiereT. AndalibB. BellC. P. BidinostiE. CudmoreM. DasC. A. DavisB. FrankeM. GerickeP. GiampaP. Gnyp  +41
The authors report the first production of ultracold neutrons (UCN) at TRIUMF using a superfluid-helium converter cooled to 0.9 K. After a one-minute irradiation of the spallation target, they extracted up to 325000 UCN, more than three times the previous best for this source, corresponding to a density of 5.3 cm$^{-3}$ in the production and guide volume. The initial storage lifetime was 37 s, dropping to 24 s over eighteen days. Simulations of UCN production, transport, and temperature-dependent yield and storage lifetime agree well with data and confirm that the UCN upscattering rate in superfluid helium is proportional to $T^7$.
arXivarXiv · · September 11, 2018
0
79
Frequent collaborators
R. Chen (3)
E. Figueroa-Feliciano (3)
Z. Hong (3)
V. Novati (3)
B. Schmidt (3)
L. Winslow (3)
G. Bratrud (2)
K. T. Kennard (2)
M. Lisovenko (2)
L. O. Mateo (2)
G. Wang (2)
J. Zhang (2)