MCP
ED

E. Dey

15 papers in the library

Papers

15
Evaluation of tracking plane pitch and xenon-helium gas mixtures for the NEXT experiment
NEXT CollaborationM. Pérez Maneiro…E. Dey
Using Monte Carlo simulations in the NEXT-100 geometry, with a sparse convolutional neural network separating signal from background, this study identifies optimal configurations for SiPM-based tracking planes in the NEXT neutrinoless double-beta decay program. Topological rejection power roughly doubles at 5 bar versus the 13.5 bar baseline; at 13.5 bar, finer pitch (15 mm to 5 mm) cuts accepted background by about 1.4 for fixed signal efficiency, and helium addition cuts it by up to 1.5. The authors highlight pure Xe at 15 mm and a Xe-He mixture at 10 mm as practical 13.5 bar options.
arXivarXiv · · November 18, 2026
0
Detection of scintillation light in noble gases with wavelength-shifting optical fibers
S. R. SoletiS. Torelli…E. Dey
The paper investigates wavelength-shifting (WLS) fibers coated with tetraphenyl butadiene (TPB) for detecting vacuum-ultraviolet scintillation light in gaseous xenon and argon at pressures up to 8.5 bar, targeting future high-pressure xenon time-projection chambers. In two detector configurations (SiPM and PMT readout), the central contribution is a measured light collection efficiency (LCE) of $1.18\%$ (SiPM, Xe) and $0.45\%$ (PMT, Xe), with the SiPM result representing an upper limit for realistic large-scale TPCs where additional photon losses are expected.
arXivarXiv · · July 6, 2026
0
0
Radon-induced backgrounds in the NEXT-100 experiment
NEXT CollaborationC. Cortes-Parra…E. Dey
The NEXT-100 experiment measured radon-induced backgrounds for its search for neutrinoless double-beta decay. The internal $^{222}$Rn activity was (0.95±0.04(stat)±0.09(sys)) Bq/m$^3$. The resulting background index in the region of interest is $(7.3±1.5(stat)±0.8(sys))\times10^{-4}$ counts/(keV·kg·yr) for fully contained events. Applying a topological selection that requires a single double-electron-like track reduces this index to $\sim4\times10^{-5}$ counts/(keV·kg·yr), one order of magnitude below the total radiogenic background expectation.
arXivarXiv · · April 21, 2026
0
0
Electroluminescence Yield Measurements in Xenon Gas with the NEXT-DEMO++ Detector
NEXT CollaborationJ. Renner…E. Dey
Using the NEXT-DEMO++ high-pressure xenon gas time projection chamber, a prototype for NEXT-100, the electroluminescence (EL) yield was measured as a function of reduced electric field ($E/p$) across 2.0 to 9.4 bar with the 41.5 keV $^{83m}$Kr peak. The reduced EL yield $Y/p$ was fitted linearly, revealing a modest ($\sim$5%) increase in slope starting around 5 bar and rising with pressure, addressing inconsistencies in past literature on the pressure dependence of this slope.
arXivarXiv · · April 17, 2026
0
0
Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector
NEXT CollaborationM. Pérez Maneiro…E. Dey
The NEXT-100 high-pressure xenon TPC achieves sub-percent energy resolution, critical for the neutrinoless double-beta decay ($\beta\beta0\nu$) search. Calibrated with a Th-228 source, the detector demonstrates $(0.90 \pm 0.02)\%$ FWHM resolution at the 2615-keV Tl-208 photopeak, extrapolating to $(0.93 \pm 0.02)\%$ FWHM at the $Q_{\beta\beta}$ = 2458-keV decay endpoint, confirming its design goal of <1% FWHM.
arXivarXiv · · November 4, 2025
0
3
The NEXT-100 Detector
NEXT CollaborationC. Adams…E. Dey
The NEXT-100 detector, a high-pressure gas electroluminescent time projection chamber for studying double beta decays of $^{136}$Xe, began data-taking at the Laboratorio Subterráneo de Canfranc in May 2024. It achieves exceptional energy resolution ($\leq 1\%$ FWHM at the $Q_{\beta\beta}$ value) and topological event discrimination using two sensor planes. Commissioning with argon and xenon gases demonstrated stable operation, with alpha decays from the $^{222}$Rn chain confirming a constant electron lifetime. This paper details the detector design, assembly, radiopurity budget, and commissioning results.
arXivarXiv · · May 23, 2025
0
19
High Voltage Delivery and Distribution for the NEXT-100 Time Projection Chamber
NEXT CollaborationC. Adams…E. Dey
The NEXT-100 neutrinoless double-beta-decay experiment uses a time projection chamber that requires tens of kilovolts to drift electrons over meter-scale distances. This paper describes the cathode feedthrough and high-voltage distribution through the field cage. The feedthrough withstands up to 20 bar and -65 kV, and the TPC operates stably at its design voltages within a stringent radiopurity budget, enabling sensitive double-beta-decay analyses.
arXivarXiv · · May 2, 2025
0
1
Performance of an Optical TPC Geant4 Simulation with Opticks GPU-Accelerated Photon Propagation
NEXT CollaborationI. Parmaksiz…E. Dey
This paper evaluates Opticks, a GPU-accelerated photon propagation tool based on NVIDIA OptiX API 7.5, against a single-threaded Geant4 simulation using an improved model of the NEXT-CRAB-0 gaseous time projection chamber. Opticks accelerates simulation speeds by 58.47–181.39 times relative to the CPU-only Geant4 simulation, with speedups depending on the GPU and CPU types. The number of detected photons, their times, and wavelengths agree closely between the two methods, validating Opticks as a faster alternative for optical photon simulations.
arXivarXiv · · February 18, 2025
0
3
Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
NEXT CollaborationM. Martínez-Vara…E. Dey
For a future xenon gas detector that can precisely locate the decay vertex, this paper studies the accuracy of reconstructing kinematic observables in neutrinoless double beta decay. Under realistic conditions (10 bar gas pressure, 4 mm spatial resolution), the average opening angle between the two electrons and the average single-electron energy can be measured with precisions of 0.19 and 110 keV, respectively, assuming only 10 detected events. This demonstrates the feasibility of distinguishing different lepton-number-violating mechanisms beyond light neutrino exchange.
arXivarXiv · · February 14, 2025
0
2
Ion Transport on Phased Radiofrequency Carpets in Xenon Gas
E. DeyB.J.P. JonesY. MeiM. BrodeurV.A. ChirayathN. CowardF.W. FossK.E. NavarroI. ParmaksizNEXT Collaboration
This paper presents a four-phased radiofrequency (RF) carpet system for transporting ions in high-pressure xenon gas, designed with a 160 µm pitch. The authors demonstrate transport efficiency of caesium ions at pressures up to 600 mbar and compare results with SIMION simulations. The key contribution is the novel use of an N-phased RF carpet at high pressure, enabling ion levitation and controlled lateral motion in a denser environment than typical, making it a candidate for ion transport in future neutrinoless double-beta decay experiments.
arXivarXiv · · January 30, 2025
0
0
Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers
T. ContrerasB. Palmeiro…E. Dey
Using $^{83m}\text{Kr}$ data from the NEXT-White detector, this work measures the energy resolution achievable with silicon photomultipliers (SiPMs) for future neutrinoless double beta decay searches. The obtained full-width half-maximum resolution of $(10.9 \pm 0.6)\%$ is slightly larger than predictions from photon statistics, attributed to incomplete corrections. SiPM noise is not a dominant factor and can be made negligible with appropriate subtraction. These results support the development of SiPM-only readout planes that combine imaging capability with energy resolution comparable to that of conventional photomultiplier tubes.
arXivarXiv · · May 30, 2024
0
3
Fluorescence Imaging of Individual Ions and Molecules in Pressurized Noble Gases for Barium Tagging in 136^{136}Xe
NEXT CollaborationN. ByrnesE. DeyF.W. FossB.J.P. JonesR. MadiganA. McDonaldR.L. MillerK.E. NavarroL.R. NormanD.R. NygrenC. Adams  +103
This paper demonstrates selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment, a key step for barium tagging in neutrinoless double beta decay searches in $^{136}$Xe. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with a 1x1 cm$^2$ scan area, operating inside 10 bar of xenon gas.
arXivarXiv · · May 20, 2024
0
11
Demonstration of Event Position Reconstruction based on Diffusion in the NEXT-White Detector
J.HaefnerK.E.Navarro…E.Dey
The paper demonstrates event position reconstruction in the NEXT-White detector by quantifying electron diffusion in a high-pressure xenon gas TPC, without relying on primary scintillation timing. For low-energy $^{83\mathrm{m}}$Kr point-like deposits ($E\sim45$keV), the drift distance is determined to 2~cm precision with bias $<1$mm. A convolutional neural network applied to longer tracks ($E\geq1.5$MeV) achieves 3~cm precision on the event barycenter. These results support sub-1% FWHM energy calibration at $Q_{\beta\beta}$ and enable fiducialization in future large detectors.
arXivarXiv · · November 6, 2023
0
5
Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT
NEXT CollaborationP. Novella…E. Dey
The NEXT experiment demonstrates neutrinoless double beta decay ($0\nu\beta\beta$) searches in gaseous xenon using the NEXT-White detector. With a 1% FWHM energy resolution at 2.6 MeV and topological background rejection, the analysis combines 271.6 days of $^{136}$Xe-enriched and 208.9 days of $^{136}$Xe-depleted data. Two analysis methods—a background-model-dependent approach and a direct background-subtraction technique—yield 90% C.L. lower limits on the half-life in the range $T_{1/2}^{0\nu} > 5.5\times10^{23} - 1.3\times10^{24}$ yr, using a fiducial mass of $3.50\pm0.01$ kg of $^{136}$Xe-enriched xenon. This serves as a proof-of-concept for larger NEXT detectors.
arXivarXiv · · May 16, 2023
0
55
Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness
J. HaefnerA. Fahs…E. Dey
The authors measure the reflectance of PTFE coated with TPB at 200, 260, and 450 nm in air and find that at 450 nm the reflectance is approximately 92% for thicknesses from 5 mm to 10 mm, with negligible variation within this range. A cross-check in an argon chamber at 128 nm confirms that reducing thickness from 10 mm to 5 mm does not significantly affect light response. This indicates that thinner TPB-coated PTFE can be used in particle physics detectors without compromising the light signal.
arXivarXiv · · November 9, 2022
0
8
Frequent collaborators
N. López-March (13)
J. Renner (13)
H. Almazán (13)
V. Álvarez (13)
L. Arazi (13)
F. Auria-Luna (13)
S. Ayet (13)
F. Ballester (13)
R. Esteve (13)
R. Felkai (13)
Z. Freixa (13)
R. Guenette (13)