MCP
EH

E. E. Haller

48 papers in the library

Papers

30
Double-beta decay of 130{}^{130}Te to the first 0+0^+ excited state of 130{}^{130}Xe with CUORE-0
CUORE CollaborationC. Alduino…E. E. Haller
Using a 9.8 kg·yr exposure of $^{130}$Te collected with CUORE-0, a search for double-beta decay to the first $0^+$ excited state of $^{130}$Xe found no evidence for either neutrinoless or two-neutrino modes, yielding lower half-life bounds of $\tau^{0\nu}_{0^+}>7.9\cdot 10^{23}$ yr and $\tau^{2\nu}_{0^+}>2.4\cdot 10^{23}$ yr. Combining these with CUORICINO results gives the most stringent constraints: $\tau^{0\nu}_{0^+}>1.4\cdot 10^{24}$ yr and $\tau^{2\nu}_{0^+}>2.5\cdot 10^{23}$ yr.
arXivarXiv · · November 26, 2018
0
First Results from CUORE: A Search for Lepton Number Violation via 0νββ0νββ Decay of 130^{130}Te
CUORE CollaborationC. Alduino…E. E. Haller
The CUORE experiment, a ton-scale cryogenic bolometer array, performed its first high-sensitivity search for $^{130}$Te neutrinoless double-beta decay ($0\nu\beta\beta$), a lepton-number-violating process. Based on 86.3 kg$\cdot$yr of TeO$_2$ exposure with an energy resolution of $(7.7 \pm 0.5)$ keV FWHM and background of $(0.014 \pm 0.002)$ counts/(keV$\cdot$kg$\cdot$yr), no evidence for $0\nu\beta\beta$ was found. The median sensitivity was $7.0\times10^{24}$ yr, and a lower limit of $T^{0\nu}_{1/2}(^{130}\text{Te}) > 1.3\times10^{25}$ yr (90% C.L.) was set. Combined with earlier experiments, the limit increased to $>1.5\times10^{25}$ yr, the most stringent yet, corresponding to an effective Majorana neutrino mass $m_{\beta\beta} < (110-520)$ meV.
arXivarXiv · · October 22, 2017
0
Low Energy Analysis Techniques for CUORE
CUORE CollaborationC. Alduino…E. E. Haller
This paper presents low-energy analysis techniques for CUORE, a tonne-scale cryogenic detector searching for neutrinoless double-beta decay of $^{130}$Te. To enable rare-event searches like solar axions or WIMP scattering, the energy threshold is improved to 10 keV. Using data from the CUORE-0 prototype (November 2013 – March 2015), the authors detail threshold optimization, trigger efficiency monitoring, event selection, and low-energy calibration. They also show the low-energy background spectrum below 60 keV and report CUORE's sensitivity to WIMP annual modulation based on CUORE-0's performance.
arXivarXiv · · August 25, 2017
0
36
CUORE Sensitivity to 0νββ0νββ Decay
CUORE CollaborationC. Alduino…E. E. Haller
The CUORE experiment's sensitivity to neutrinoless double beta decay is evaluated via a Bayesian toy Monte Carlo analysis. With expected background and energy resolution, the 90% credibility interval exclusion sensitivity on the half-life $T_{1/2}^{0\nu}$ reaches $2\times10^{25}$ yr after 3 months and $9\times10^{25}$ yr after 5 years of live time. The corresponding $3\sigma$ discovery sensitivities are $7\times10^{24}$ yr and $4\times10^{25}$ yr, respectively.
arXivarXiv · · May 30, 2017
0
71
The projected background for the CUORE experiment
CUORE CollaborationC. Alduino…E. E. Haller
The CUORE experiment searches for neutrinoless double beta decay of $^{130}\text{Te}$ using 988 TeO$_2$ bolometers at $∼10$ mK. To achieve a $9\times10^{25}$-year half-life exclusion sensitivity, the background rate in the region of interest must be $≤10^{-2}$ counts/keV/kg/y. This paper presents a detailed Monte Carlo simulation, built from material screening, radioassays, and bolometric measurements, that projects the expected background. The model has guided the experiment's construction and now provides the background estimate for the upcoming physics run.
arXivarXiv · · April 28, 2017
0
215
The CUORE and CUORE-0 experiments at LNGS
A. D&#39;AddabboC. Alduino…E. E. Haller
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton bolometric experiment searching for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{130}$Te using 988 TeO$_2$ crystals at 10 mK. Its demonstrator, CUORE-0, operated from 2013 to 2015 and represents the largest $^{130}$Te bolometric setup ever run. This paper presents the final CUORE-0 $0\nu\beta\beta$ analysis and detector performance, together with the status of CUORE's construction and cryostat commissioning.
arXivarXiv · · December 13, 2016
0
1
Measurement of the Two-Neutrino Double Beta Decay Half-life of 130^{130}Te with the CUORE-0 Experiment
CUORE CollaborationC. Alduino…E. E. Haller
The CUORE-0 experiment measured the two-neutrino double beta decay half-life of $^{130}$Te using a 33.4 kg$\cdot$y exposure of TeO$_2$. The result is $T_{1/2}^{2\nu} = [8.2 \pm 0.2\,(\text{stat.}) \pm 0.6\,(\text{syst.})] \times 10^{20}$ y, obtained after detailed reconstruction of the detector's counting rate and background sources, including those affecting the neutrinoless double beta decay region of interest.
arXivarXiv · · September 6, 2016
0
173
Large Stark tuning of donor electron spin quantum bits in germanium
A. J. SigillitoA. M. TyryshkinJ. W. BeemanE. E. HallerK. M. ItohS. A. Lyon
This paper demonstrates that replacing silicon with germanium as the host material for donor electron spin qubits enables Stark tuning of the qubit energy by more than the ensemble linewidth, making them compatible with gate-addressable architectures. Using X-band pulsed ESR, the authors measured the Stark effect for $^{75}$As and $^{31}$P donor electrons in germanium at 0.4 T, finding that the spin-orbit Stark shift dominates and is highly anisotropic. The spin-orbit Stark parameter is four orders of magnitude larger than in silicon, and the hyperfine Stark effect is an order of magnitude larger. Specifically, $^{31}$P donors in germanium can be tuned by at least four times the ensemble linewidth, highlighting germanium's advantage over silicon for spin qubits.
arXivarXiv · · June 10, 2016
0
CUORE-0 detector: design, construction and operation
CUORE CollaborationC. Alduino…E. E. Haller
The CUORE-0 detector, a prototype tower of 52 TeO$_2$ bolometers built using CUORE assembly procedures, operated at Laboratori Nazionali del Gran Sasso from 2013 to 2015. Its design, construction, and operation improved upon the predecessor Cuoricino, and data from CUORE-0 demonstrate that the design goals of the full 988-bolometer CUORE experiment for neutrinoless double-beta decay search are achievable.
arXivarXiv · · April 19, 2016
0
156
Magnetic effects in sulfur-decorated graphene
Choongyu HwangShane A. Cybart…E. E. Haller
Proximity to sulfur, a diamagnetic insulator, induces magnetic effects in graphene that are absent in clean graphene. For the graphene/sulfur compound, an energy gap opens at the Fermi level as temperature decreases, accompanied by a steep resistance increase, a sign change in the magneto-resistance slope between high and low fields, and magnetic hysteresis. These results suggest the onset of low-temperature magnetic ordering in a graphene-based compound.
arXivarXiv · · February 19, 2016
0
20
Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in 130^{130}Te with CUORE-0
CUORE CollaborationC. Alduino…E. E. Haller
This paper details the analysis techniques used by the CUORE-0 bolometric detector array to search for neutrinoless double-beta decay in $^{130}\text{Te}$. The central contribution is a comprehensive description of the methods for data collection, event selection, and energy calibration that produced the final search spectrum. The analysis yielded a half-life limit of $T^{0\nu}_{1/2} > 2.7 \times 10^{24}$ yr for CUORE-0 alone, and $T^{0\nu}_{1/2} > 4.0 \times 10^{24}$ yr when combined with the Cuoricino experiment, establishing a competitive bound on the effective Majorana neutrino mass.
arXivarXiv · · January 6, 2016
0
Electron spin coherence of shallow donors in natural and isotopically enriched germanium
A. J. SigillitoR. M. JockA. M. TyryshkinJ. W. BeemanE. E. HallerK. M. ItohS. A. Lyon
This paper reports the first pulsed ESR measurements of coherence ($T_2$) and relaxation ($T_1$) times for arsenic and phosphorus donors in germanium. Spectral diffusion from $^{73}$Ge nuclear spins limits $T_2$ in samples with substantial $^{73}$Ge, while in highly isotopically enriched samples $T_2$ is limited by $T_1$ to $T_2 = 2T_1$. An anisotropy in $T_1$ and ensemble linewidths is observed across crystal axes, but no angular dependence appears in the spectral-diffusion-limited $T_2$.
arXivarXiv · · June 18, 2015
0
64
Search for Neutrinoless Double-Beta Decay of 130^{130}Te with CUORE-0
K. AlfonsoD.R. Artusa…E.E. Haller
CUORE-0, a bolometric detector array, searched for neutrinoless double-beta decay of $^{130}$Te in a 9.8 kg$\cdot$yr exposure. With an energy resolution of $5.1\pm 0.3$ keV FWHM and a background of $0.058 \pm 0.004$ counts/(keV$\cdot$kg$\cdot$yr) in the region of interest, it found no signal. The experiment set a Bayesian lower limit on the half-life of $T^{0\nu}_{1/2} > 2.7 \times 10^{24}$ yr at 90% C.L., and a combined analysis with Cuoricino data yielded $T^{0\nu}_{1/2} > 4.0 \times 10^{24}$ yr, the most stringent limit on $^{130}$Te to date, corresponding to an effective Majorana neutrino mass $m_{\beta\beta} < 270$--$760$ meV.
arXivarXiv · · April 9, 2015
0
Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments
CUORE CollaborationM. Sisti…E.E. Haller
CUORE, a 741 kg array of TeO₂ bolometers searching for neutrinoless double beta decay of ¹³⁰Te, aims for a 1σ half-life sensitivity of 10²⁶ y in five years at a background of 0.01 counts/keV/kg/y. Its precursor, CUORE‑0 (a single 52‑bolometer tower), began taking data in spring 2013 to verify expected performance. This paper reports CUORE’s status and presents the first CUORE‑0 data.
arXivarXiv · · February 12, 2015
0
11
CUORE-0 results and prospects for the CUORE experiment
CUORE CollaborationD.R. Artusa…E.E. Haller
The CUORE-0 detector, a single CUORE-style tower of 52 TeO₂ bolometers, tested the background and performance of the upcoming CUORE experiment. With 18.1 kg·yr exposure, CUORE-0 data show the background meets CUORE's design goal, and the projected neutrinoless double-beta decay half-life sensitivity of $1.6\times10^{26}$ yr (1σ) for $^{130}$Te in five years of live time is within reach.
arXivarXiv · · February 9, 2015
0
1
Host isotope mass effects on the hyperfine interaction of group-V donors in silicon
T. SekiguchiA. M. TyryshkinS. TojoE. AbeR. MoriH. RiemannN. V. AbrosimovP. BeckerH.-J. PohlJ. W. AgerE. E. HallerM. L. W. Thewalt  +3
Pulsed ENDOR spectroscopy of isotopically engineered Si reveals that the hyperfine interaction of group-V donors (P, As, Sb, Bi) is modulated by the host Si isotope mass. Each hyperfine-split donor ENDOR line splits into components whose relative intensities match the statistical probability of the nine possible average Si masses at the four nearest-neighbor sites, arising from random occupation by Si-28, Si-29, and Si-30. For P-31 donors, the resolved components shift linearly with the bulk-averaged Si mass.
arXivarXiv · · July 25, 2014
0
12
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
D. R. ArtusaF. T. Avignone III…E. E. Haller
The CUORE experiment uses 741 kg of TeO$_2$ crystals with 5 keV (0.2%) energy resolution to search for neutrinoless double beta decay of $^{130}$Te. Its projected half-life sensitivity after five years is $1.6\times10^{26}$ y at $1\sigma$ ($9.5\times10^{25}$ y at 90% CL), corresponding to an effective Majorana mass limit of 40--100 meV (50--130 meV). The paper further notes that adding auxiliary light detectors for background rejection could enable bolometric detectors to fully explore the inverted neutrino mass hierarchy with $^{130}$Te and other nuclei.
arXivarXiv · · July 4, 2014
0
0
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
D. R. ArtusaF. T. Avignone III…E. E. Haller
This paper reviews the status and outlook of bolometric neutrinoless double beta decay ($0\nu\beta\beta$) searches, focusing on the goal of fully exploring the inverted neutrino mass hierarchy. By simulating a future CUORE-like detector array with improved background suppression from simultaneous heat and light readout, the authors show that a bolometric experiment with approximately 1 ton of isotope mass could reach a sensitivity to the effective Majorana neutrino mass $|m_{ee}|$ of order 10–20 meV, thereby covering the entire inverted hierarchy region. The paper also identifies key challenges and R&D priorities.
arXivarXiv · · April 17, 2014
0
142
Searching for neutrinoless double-beta decay of 130^{130}Te with CUORE
CUORE CollaborationD. R. Artusa…E. E. Haller
CUORE is a cryogenic bolometer array built to search for neutrinoless double-beta decay of $^{130}$Te, a hypothesized lepton-number-violating process. The detector uses 988 TeO$_2$ crystals operated at 10 mK, containing 206 kg of $^{130}$Te with an average energy resolution of 5 keV. The projected half-life sensitivity after five years of live time is $1.6\times10^{26}$ y at $1\sigma$, corresponding to an upper limit on the effective Majorana mass of 40--100 meV.
arXivarXiv · · February 25, 2014
0
234
Initial performance of the CUORE-0 experiment
CUORE CollaborationD. R. Artusa…E. E. Haller
CUORE-0, a cryogenic array of TeO$_2$ bolometers, searches for neutrinoless double-beta decay of $^{130}$Te. Analyzing 7.1 kg·y of exposure, it measures a background rate of $0.071 \pm 0.011$ counts/keV/kg/y in the 2.47–2.57 MeV region of interest and $0.019 \pm 0.002$ counts/keV/kg/y in the 2.70–3.90 MeV $α$-dominated region—a factor of 6 improvement over its predecessor Cuoricino. The energy resolution (FWHM) in the region of interest is 5.7 keV, and with one year of live time the half-life sensitivity is expected to surpass Cuoricino's lower bound.
arXivarXiv · · February 5, 2014
0
118
Validation of techniques to mitigate copper surface contamination in CUORE
F. AlessandriaR. Ardito…E. E. Haller
The CUORE experiment faces background from copper surface contamination, which mimics the neutrinoless double-beta decay signal. This paper validates three mitigation techniques using a dedicated test apparatus. The achieved contamination levels below $10^{-7}$–$10^{-8}$ Bq/cm² for $^{238}$U and $^{232}$Th would yield a projected background of 0.02–0.03 counts/keV/kg/y in the region of interest, confirming that the techniques can meet CUORE's stringent radiopurity requirements.
arXivarXiv · · October 3, 2012
0
125
Search for 14.4 keV solar axions from M1 transition of Fe-57 with CUORE crystals
Cuore CollaborationF. Alessandria…E. E. Haller
The paper reports a search for 14.4 keV solar axions from the Fe-57 M1 transition using the axio-electric effect in TeO2 bolometers. With 43.65 kg d of CUORE test data, an upper limit of 0.63 c kg⁻¹ d⁻¹ (95% C.L.) was set, yielding a lower bound on the Peccei-Quinn energy scale fa ≥ 0.76 × 10⁶ GeV for a flavor-singlet axial vector matrix element S = 0.55, with bounds given for 0.15 < S < 0.55.
arXivarXiv · · September 13, 2012
0
63
The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
F. AlessandriaR. Ardito…E. E. Haller
Using 19.4 days of data from four 750~g TeO$_2$ bolometers, a new analysis technique lowered the energy threshold to about 3~keV in three detectors. The measured background rate falls from 25~cpd/keV/kg at 3~keV to 2~cpd/keV/kg at 25~keV. An unexplained 4.7~keV peak is confirmed by reanalysis of 62.7~kg·days of CUORICINO data. Expected sensitivities of CUORE-0 and CUORE to a WIMP annual modulation signal are reported.
arXivarXiv · · September 12, 2012
0
Sensitivity and Discovery Potential of CUORE to Neutrinoless Double-Beta Decay
F. AlessandriaR. Ardito…E. E. Haller
This paper evaluates CUORE's sensitivity and discovery potential for neutrinoless double-beta decay. Computing sensitivity for various background scenarios, the authors find that with a background rate of $10^{-2}$ cts/(keV kg y) and 5 years of live time, the 1-sigma half-life sensitivity is $T_{1/2}(1\sigma) = 1.6 \times 10^{26}$ y, probing effective Majorana neutrino masses down to 40-100 meV. The 90% C.L. sensitivity is $T_{1/2}(1.64\sigma) = 9.5 \times 10^{25}$ y. This range is compared with the claimed observation in $^{76}$Ge and oscillation-based neutrino mass parameter space.
arXivarXiv · · September 2, 2011
0
21
CUORE crystal validation runs: results on radioactive contamination and extrapolation to CUORE background
F. AlessandriaE. Andreotti…E. E. Haller
This paper presents the radiopurity results of the first five CUORE Crystal Validation Runs (CCVRs) for TeO₂ crystals produced at SICCAS. Bulk and surface contaminations from several nuclides are measured. Based on these measurements, an extrapolation to the CUORE experiment's background level is performed.
arXivarXiv · · August 24, 2011
0
124
Double-beta decay of 130^{130}Te to the first 0+^{+} excited state of 130^{130}Xe with CUORICINO
E. AndreottiC. Arnaboldi…E. E. Haller
Using the CUORICINO TeO₂ bolometer array (11.3 kg of ¹³⁰Te, 9.5 × 10²⁵ y exposure), no evidence was found for double-beta decay of ¹³⁰Te to the first 0⁺ excited state of ¹³⁰Xe. The resulting lower limits are T^{2ν}_{1/2} > 1.3 × 10²³ y and T^{0ν}_{1/2} > 9.4 × 10²³ y, both at 90% C.L.
arXivarXiv · · August 22, 2011
0
130Te Neutrinoless Double-Beta Decay with CUORICINO
E. AndreottiC. Arnaboldi…E. E. Haller
The CUORICINO experiment, operating from 2003 to 2008 with a total exposure of 19.75 kg yr of $^{130}\text{Te}$, reports a lower bound on the $0\nu\beta\beta$ half-life of $2.8 \times 10^{24}$ years at 90% C.L. after accounting for systematic uncertainties. This implies an upper bound on the neutrino Majorana mass of 300–710 meV, depending on the nuclear matrix element evaluation used.
arXivarXiv · · December 15, 2010
0
407
Effect of pulse error accumulation on dynamical decoupling of the electron spins of phosphorus donors in silicon
Zhi-Hui WangWenxian ZhangA. M. TyryshkinS. A. LyonJ. W. AgerE. E. HallerV. V. Dobrovitski
For electron spins of phosphorus donors in silicon, pulse errors in dynamical decoupling (DD) sequences accumulate differently depending on the spin state. Periodic DD sequences using $x$/$y$ rotations outperform $x$/$z$ rotations by avoiding rapid error accumulation in some states. Concatenation suppresses pulse errors to first order: fidelity remains high for all spin components even as the number of pulses grows exponentially, matching experimental results.
arXivarXiv · · November 29, 2010
0
68
Dynamical Decoupling in the Presence of Realistic Pulse Errors
A. M. TyryshkinZhi-Hui WangWenxian ZhangE. E. HallerJ. W. AgerV. V. DobrovitskiS. A. Lyon
A major obstacle for quantum information processors is errors. Dynamical decoupling cancels correlated noise without extra qubits, but imperfect control pulses introduce instrumental errors. Using electron spin resonance of donor spins in ^{28}Si, we compare decoupling sequences. Only XYXY sequences, based on alternating π-rotations about X and Y, store arbitrary quantum states. Their superior performance arises because they are self-correcting for the dominant instrumental pulse errors. Concatenated XYXY sequences maintain near-100% fidelity after hundreds of pulses because the first-order error does not increase with concatenation.
arXivarXiv · · November 8, 2010
0
18
Muon-induced backgrounds in the CUORICINO experiment
E. AndreottiC. Arnaboldi…E. E. Haller
From dedicated measurements with 10 plastic scintillator detectors during the final 3 months of the CUORICINO experiment, an upper limit of 0.0021 counts/(keV kg yr) (95% CL) was set on the cosmic-ray muon-induced background in the neutrinoless double-beta-decay region of interest. The measurements were compared to Geant4 simulations.
arXivarXiv · · December 18, 2009
0
58
Frequent collaborators
C. Brofferio (27)
C. Bucci (27)
S. Capelli (27)
O. Cremonesi (27)
E. Fiorini (27)
A. Nucciotti (27)
M. Pavan (27)
G. Pessina (27)
S. Pirro (27)
E. Previtali (27)
C. Rosenfeld (27)
M. Sisti (27)