A comparative study of deconvolution techniques for quantum-gas microscope images
A. La RooijC. UlmE. HallerS. Kuhr
A. La Rooij
C. Ulm
E. Haller
S. Kuhr
+4
This study compares three deconvolution techniques—local iterative algorithm, Wiener deconvolution, and Lucy-Richardson algorithm—for quantum-gas microscope images where atoms are separated near or below the diffraction limit. Using simulated images, it evaluates reconstruction fidelity under varying signal-to-noise ratio, lattice filling fraction, fluorescence per atom, and imaging resolution. The results identify single-atom detection limits and provide quantitative fidelities applicable across different atomic species and microscope setups.

arXiv ·