MCP
EM

E Massa

5 papers in the library

Papers

5
Wavefront errors in a two-beam interferometer
G ManaE MassaC P Sasso
This paper examines how wavefront errors from optical aberrations in a two-beam interferometer affect the period of travelling fringes observed by integrating the interference pattern. Monte Carlo simulation shows that the fringe-period estimate remains unbiased when evaluated using the angular spectrum of the entering beam, but the wavefront errors increase the uncertainty of the estimate.
arXivarXiv · · July 16, 2020
0
Improved measurement results for the Avogadro constant using a 28Si-enriched crystal
Y AzumaP Barat…E Massa
By reconditioning two 28Si-enriched spheres to remove metal contamination and improve sphericity, then measuring them with improved methods and apparatus, the X-ray crystal density method achieved the target relative standard uncertainty of 2.0×10⁻⁸ for the Avogadro constant. The result is $N_A = 6.02214076(12) \times 10^{23}$ mol⁻¹.
arXivarXiv · · December 16, 2015
0
The watt-balance operation: magnetic force and induced electric potential on a conductor in a magnetic field
C. P. SassoE. MassaG. Mana
This paper re-examines the magnetic force and induced electric potential in a watt balance from a microscopic perspective, focusing on corrective terms from a non-uniform conduction electron density caused by the magnetic field. The analysis shows that these corrections are irrelevant to the watt balance operation, confirming the validity of the macroscopic equations used for Planck constant measurement.
arXivarXiv · · December 21, 2012
0
An accurate determination of the Avogadro constant by counting the atoms in a 28Si crystal
B. AndreasY. Azuma…E. Massa
The paper reports a determination of the Avogadro constant by counting the atoms in 1 kg single-crystal spheres highly enriched with the 28Si isotope. This approach, using isotope dilution mass spectroscopy to measure the molar mass with unprecedented accuracy, yields a value of 6.02214084(18) × 10^23 mol^-1, which is the most accurate input datum for redefining the kilogram in terms of a fundamental constant.
arXivarXiv · · October 12, 2010
0
Comparison of the INRIM and PTB lattice-spacing standards
E MassaG ManaU Kuetgens
This paper compares lattice-spacing standards from INRIM and PTB to support redefining the kilogram via the $^{28}\text{Si}$ atomic mass, which requires a relative lattice-parameter uncertainty of $3\times10^{-9}$. INRIM built a new apparatus with a centimetre measurement baseline. The comparison of crystals MO*4 (INRIM) and WASO4.2a (PTB) aims to verify measurement capabilities and assess experimental limits.
arXivarXiv · · February 3, 2009
0
Frequent collaborators
G Mana (3)
U Kuetgens (2)
G. Mana (2)
C P Sasso (1)
Y Azuma (1)
P Barat (1)
G Bartl (1)
H Bettin (1)
M Borys (1)
I Busch (1)
L Cibik (1)
G D'Agostino (1)