30
The MAJORANA DEMONSTRATOR Readout Electronics System
N. AbgrallM. AmmanI.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonP.J. BartonF.E. BertrandK.H. BhimaniB. BosA.W. BradleyT.H. Burritt  +67
The MAJORANA DEMONSTRATOR readout electronics system is described, covering front-end and back-end electronics, cabling, digitizers, and power supplies with a grounding scheme. It was designed for low electronic noise and minimal radioactive background, using low-mass components and low-radioactivity materials near the high-purity germanium detectors. The spectroscopic performance achieved with this system is also demonstrated.
arXivarXiv · · November 17, 2021
0
20
Signatures of muonic activation in the Majorana Demonstrator
I.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonF.E. BertrandE. BlalockB. BosM. BuschM. BuuckT.S. CaldwellY-D. ChanC.D. Christofferson  +46
The Majorana Demonstrator searches for neutrinoless double-beta decay, requiring extremely low backgrounds. This work uses the Demonstrator's data to identify decay signatures of metastable germanium isotopes produced by muon interactions within the detectors themselves. By correlating time-delayed signals, the measured rate of these decays is found to agree well with simulations. The validated simulation framework is then extended to predict the cosmogenic background for the future tonne-scale LEGEND experiment, which aims for a sensitivity of $10^{28}$ years half-life.
arXivarXiv · · October 27, 2021
0
12
The Majorana Demonstrator's Search for Double-Beta Decay of 76^{76}Ge to Excited States of 76^{76}Se
I.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonF.E. BertrandE. BlalockB. BosM. BuschM. BuuckT.S. CaldwellY-D. ChanC.D. Christofferson  +51
The Majorana Demonstrator, a low-background array of high-purity germanium detectors (≈2/3 enriched to 88% in $^{76}$Ge), searches for double-beta decay of $^{76}$Ge to excited states of $^{76}$Se. The signature involves a $\beta\beta$ decay followed by prompt $\gamma$-rays, producing multi-detector coincidences. With 41.9 kg-y of isotopic exposure, the experiment set world-leading 90% CL lower half-life limits for each excited-state decay, ranging from $(0.75-4.0)\times10^{24}$ y, including $7.5\times10^{23}$ y for the $2\nu$ transition to the first $0^+$ excited state.
arXivarXiv · · August 13, 2020
0
3
Results of the MAJORANA DEMONSTRATOR's Search for Double-Beta Decay of 76^{76}Ge to Excited States of 76^{76}Se
I.S. GuinnI.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonF.E. BertrandB. BosM. BuschM. BuuckT.S. CaldwellY-D. ChanC.D. Christofferson  +48
The MAJORANA DEMONSTRATOR searched for double-beta decay of $^{76}$Ge to excited states of $^{76}$Se using a modular array of high-purity germanium detectors. The distinctive multi-site event signature of the $\beta\beta$ decay with prompt $\gamma$-rays, combined with the detector's granularity, enabled strong background discrimination. With 21.3 kg-y of isotopic exposure, the experiment set world-leading 90% CL lower half-life limits of $(0.56-2.1)\times 10^{24}$ y for each excited-state decay, including $0.68\times 10^{24}$ y for the $2\nu$ transition to the first $0^+$ state.
arXivarXiv · · December 12, 2019
0
6
A Low Energy Rare Event Search with the Majorana Demonstrator
MAJORANA CollaborationC. WisemanI.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonF.E. BertrandB. BosM. BuschM. BuuckT.S. CaldwellY-D. Chan  +50
Using the MAJORANA DEMONSTRATOR, a low-energy rare-event search is conducted with a novel training set of small-angle Compton scatter events to determine pulse-shape analysis cut efficiency. Based on an 11.17 kg-y dataset and a 5 keV threshold, updated exclusion limits are set for bosonic dark matter and solar axions, demonstrating sensitivity to sub-keV interactions.
arXivarXiv · · December 12, 2019
0
10
A Search for Neutrinoless Double-Beta Decay in 76^{76}Ge with 26 kg-yr of Exposure from the MAJORANA DEMONSTRATOR
S.I. AlvisI.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonV. BasuF.E. BertrandB. BosM. BuschM. BuuckT.S. CaldwellY-D. Chan  +52
The MAJORANA DEMONSTRATOR, an array of high-purity Ge detectors (29.7 kg enriched in $^{76}$Ge) at the Sanford Underground Research Facility, searches for neutrinoless double-beta decay. With 26.0 kg-yr of enriched exposure and an energy resolution of 2.53 keV FWHM at $Q_{\beta\beta}$, the collaboration observes one event in the region of interest against 0.65 expected background events, setting a lower limit on the $^{76}$Ge half-life of $2.7\times10^{25}$ yr (90% CL) and a median sensitivity of $4.8\times10^{25}$ yr (90% CL). This corresponds to a 90% CL upper limit on the effective Majorana neutrino mass of 200–433 meV, depending on nuclear matrix elements.
arXivarXiv · · February 6, 2019
0
Multi-site event discrimination for the MAJORANA DEMONSTRATOR
S.I. AlvisI.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonF.E. BertrandB. BosM. BuuckT.S. CaldwellY-D. ChanC.D. ChristoffersonP.-H. Chu  +51
For the MAJORANA DEMONSTRATOR's search for neutrinoless double-beta decay in $^{76}$Ge, a pulse-shape analysis cut named AvsE is developed to discriminate multi-site background events from single-site signal events. The cut uses the relationship between maximum current and energy, retaining $(90 \pm 3.5)\%$ of single-site events while rejecting multi-site waveforms. Its efficiency uncertainty includes variation across detectors, energy, and time, and the position-distribution difference between calibration and $0\nu\beta\beta$ events, determined via simulations.
arXivarXiv · · January 16, 2019
0
Recent results from the MAJORANA DEMONSTRATOR
J. MyslikS. I. AlvisI. J. ArnquistF. T. Avignone IIIA. S. BarabashC. J. BartonF. E. BertrandT. BodeB. BosV. BrudaninM. BuschM. Buuck  +56
The MAJORANA DEMONSTRATOR searches for neutrinoless double-beta decay in $^{76}$Ge using two modules of germanium detectors totaling 44.1 kg at the Sanford Underground Research Facility. Its ultra-low background and record energy resolution enable a sensitive search for this decay, testing lepton number conservation. The paper reports the latest results from this search, discusses design elements enabling such sensitivity, and outlines plans for a future tonne-scale $^{76}$Ge experiment.
arXivarXiv · · December 19, 2018
0
Search for Tri-Nucleon Decay in the Majorana Demonstrator
S.I. AlvisI.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonF.E. BertrandB. BosV. BrudaninM. BuschM. BuuckT.S. CaldwellY-D. Chan  +54
Using the ultra-low-background Majorana Demonstrator, an experiment primarily designed for neutrinoless double-beta decay in $^{76}$Ge, the first limits on tri-nucleon decay are reported. For the $^{76}$Ge(ppn) → $^{73}$Zn $e^+\pi^+$ mode, a half-life limit of $4.9 \times 10^{25}$ yr is set; for the $^{76}$Ge(ppp) → $^{73}$Cu $e^+\pi^+\pi^+$ mode, the limit is $4.7 \times 10^{25}$ yr. An invisible tri-proton decay mode of $^{76}$Ge yields a half-life limit of $7.5 \times 10^{24}$ yr.
arXivarXiv · · December 3, 2018
0
Recent Results from the Majorana Demonstrator
T GillissS I AlvisI J ArnquistF T Avignone IIIA S BarabashC J BartonF E BertrandT BodeV BrudaninM BuschM BuuckT S Caldwell  +56
The MAJORANA DEMONSTRATOR, an array of high-purity Ge detectors searching for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{76}$Ge, has completed construction and is operating at the Sanford Underground Research Facility. Its primary goal is to establish a low-background design scalable to a tonne-scale experiment. This paper reports initial background levels in the $0\nu\beta\beta$ region of interest, alongside first results from searches for bosonic dark matter, solar axions, Pauli exclusion principle violation, and electron decay using P-type point-contact detectors with sub-keV thresholds.
arXivarXiv · · April 4, 2018
0
The Majorana Demonstrator Status and Preliminary Results
C. -H. YuS. I. AlvisI. J. ArnquistF. T. Avignone IIIA. S. BarabashC. J. BartonF. E. BertrandT. BodeV. BrudaninM. BuschM. BuuckT. S. Caldwell  +54
The Majorana Demonstrator, an array of high-purity Ge detectors searching for neutrinoless double-beta decay in $^{76}$Ge, achieved a 2.5 keV FWHM energy resolution at $Q_{\beta\beta}$ and high detector-production efficiency. Its 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in $^{76}$Ge) operate within a low-background shield. Physics data-taking began in 2016. This paper outlines construction and reports preliminary results from the initial data run.
arXivarXiv · · March 29, 2018
0
3
First Limit on the Direct Detection of Lightly Ionizing Particles for Electric Charge as Low as ee/1000 with the \textsc{Majorana Demonstrator}
S. I. AlvisI. J. ArnquistF. T. Avignone IIIA. S. BarabashC. J. BartonF. E. BertrandV. BrudaninM. BuschM. BuuckT. S. CaldwellY-D. ChanC. D. Christofferson  +52
The Majorana Demonstrator, a low-background germanium detector array searching for neutrinoless double-beta decay, also enables a search for free relativistic lightly ionizing particles (LIPs) with charge $< e$. This analysis uses multiple-detector events with energy depositions as low as 1 keV over 285 days. No candidate events were found, yielding the first direct-detection limits on the LIP flux for charges as low as $e/1000$.
arXivarXiv · · January 30, 2018
0
0
Low Background Materials and Fabrication Techniques for Cables and Connectors in the Majorana Demonstrator
M. BuschN. AbgrallS.I. AlvisI.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonF.E. BertrandT. BodeA.W. BradleyV. BrudaninM. Buuck  +58
The Majorana Demonstrator, a Ge-76 neutrinoless double-beta decay experiment, requires cables and connectors that do not significantly raise its ultra-low radioactive background. This paper details the material selection and fabrication techniques used to meet that requirement, including a planned 2018 wiring upgrade for higher reliability. The same approach is being extended to the tonne-scale LEGEND project.
arXivarXiv · · December 13, 2017
0
5
Design improvements to cables and connectors in the Majorana Demonstrator
C. R. HaufeA. L. ReineN. AbgrallS. I. AlvisI. J. ArnquistF. T. Avignone IIIA. S. BarabashC. J. BartonF. E. BertrandT. BodeA. W. BradleyV. Brudanin  +59
The Majorana Demonstrator, searching for neutrinoless double-beta decay, uses custom low-mass cables and connectors to bias and read out its germanium detectors. These components must meet strict radiopurity standards while enduring thermal and mechanical stress. After identifying reliability issues with the current design, an improved set of cables and connectors is being developed to increase overall reliability and connectivity. This paper discusses the encountered problems, the improved designs, and initial performance results.
arXivarXiv · · December 10, 2017
0
0
Initial Results from the Majorana Demonstrator
T.S. CaldwellN. AbgrallS.I. AlvisI.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonF.E. BertrandT. BodeB. BosA.W. BradleyV. Brudanin  +60
The MAJORANA DEMONSTRATOR, an array of high-purity Ge detectors operating at the Sanford Underground Research Facility, searches for neutrinoless double-beta decay in $^{76}$Ge. Comprising 44 kg of detectors (30 kg enriched in $^{76}$Ge) with p-type point contact geometry, the array has been acquiring data since August 2016. Initial results present background estimates, exotic low-energy physics searches, and projections for physics reach, informing the design of a future ton-scale experiment.
arXivarXiv · · November 29, 2017
0
Contamination Control and Assay Results for the Majorana Demonstrator Ultra Clean Components
C.D. ChristoffersonN. AbgrallS.I. AlvisI.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonF.E. BertrandT. BodeA.W. BradleyV. BrudaninM. Busch  +58
The MAJORANA DEMONSTRATOR, a neutrinoless double beta decay experiment using enriched Ge-76 detectors, developed ultra-clean copper and plastic components through world-leading assay sensitivities. Post-production assays of Module 1 revealed increased uranium and thorium surface contamination in finished parts compared to bulk material. A revised cleaning method and additional surface studies for Module 2 demonstrated that more rigorous process control reduces surface contamination, informing ultra-clean fabrication and process design.
arXivarXiv · · November 28, 2017
0
9
Data quality assurance for the MAJORANA DEMONSTRATOR
J. MyslikN. AbgrallS. I. AlvisI. J. ArnquistF. T. Avignone IIIA. S. BarabashC. J. BartonF. E. BertrandT. BodeA. W. BradleyV. BrudaninM. Busch  +59
The paper describes the data quality assurance procedures for the MAJORANA DEMONSTRATOR, a neutrinoless double-beta decay search experiment using germanium-76 detectors. To ensure the integrity of measured energy spectra, the experiment employs a set of monitoring checks during data collection, followed by careful analysis to qualify data for physics analysis. Instrumental background events are tagged for removal, and problematic detector channels are removed from consideration as needed.
arXivarXiv · · November 28, 2017
0
1
Progress Toward A 2νββ2νββ Measurement For The Majorana Demonstrator
T GillissN AbgrallS I AlvisI J ArnquistF T Avignone IIIA S BarabashC J BartonF E BertrandT BodeA W BradleyV BrudaninM Busch  +59
The Majorana Demonstrator, a $^{76}$Ge-based neutrinoless double-beta decay ($0\nu\beta\beta$) experiment, is pursuing a measurement of the two-neutrino double-beta decay ($2\nu\beta\beta$) mode. While $2\nu\beta\beta$ is a negligible background for $0\nu\beta\beta$ searches due to the detectors' 0.1% energy resolution, its precise measurement enables systematics checks of active detector mass, enrichment fraction, and pulse shape discrimination cuts. A Bayesian fit to the full experimental background model will extract the $2\nu\beta\beta$ spectrum and half-life, and its spectral shape can be searched for distortions indicative of new physics such as $0\nu\beta\beta\chi$.
arXivarXiv · · November 15, 2017
0
0
Spectral analysis for the Majorana Demonstrator experiment
L. HehnN. AbgrallS. I. AlvisI. J. ArnquistF. T. Avignone IIIA. S. BarabashC. J. BartonF. E. BertrandT. BodeA. W. BradleyV. BrudaninM. Busch  +59
The MAJORANA DEMONSTRATOR searches for neutrinoless double-beta decay in germanium-76 using two modular arrays of natural and enriched detectors (44.1 kg total, 29.7 kg enriched) at the Sanford Underground Research Facility. Data from summer 2015 onward show a reduced background index around the $0\nu\beta\beta$ region of interest as shielding improves. The paper presents a profile-likelihood-based hypothesis test with toy Monte Carlo to derive the physics sensitivity for $10\,\textrm{kg}\cdot\textrm{y}$ exposure from enriched detectors.
arXivarXiv · · November 8, 2017
0
2
Search for Zero-Neutrino Double Beta Decay in 76Ge with the Majorana Demonstrator
C.E. AalsethN. Abgrall…F.E. Bertrand
The Majorana Demonstrator searches for neutrinoless double-beta decay in $^{76}$Ge using an array of high-purity Ge detectors. With an unprecedented energy resolution of 2.5 keV FWHM at the $Q$-value and a very low background, no candidate events were observed in 10 kg yr of enriched Ge exposure, yielding a lower half-life limit of $1.9\times10^{25}$ yr (90% CL). This constrains the effective Majorana neutrino mass to 240–520 meV, depending on nuclear matrix elements.
arXivarXiv · · October 31, 2017
0
The Status and Initial Results of the MAJORANA DEMONSTRATOR Experiment
V.E. GuiseppeN. AbgrallS.I. AlvisI.J. ArnquistF.T. Avignone IIIA.S. BarabashC.J. BartonF.E. BertrandT. BodeA.W. BradleyV. BrudaninM. Busch  +58
The MAJORANA DEMONSTRATOR, an array of high-purity Ge detectors (44.1 kg total, 29.7 kg enriched in $^{76}$Ge) at the Sanford Underground Research Facility, searches for neutrinoless double-beta decay in $^{76}$Ge. Its initial physics runs, beginning with one module in early 2016 and a second in August 2016, aim to establish the background and scalability needed for a next-generation ton-scale experiment. The paper reports the status and results of these runs, focusing on the experiment's background and physics reach.
arXivarXiv · · August 24, 2017
0
8
The Processing of Enriched Germanium for the MAJORANA DEMONSTRATOR and R&D for a Possible Future Ton-Scale Ge-76 Double-Beta Decay Experiment
N. AbgrallI.J. ArnquistF.T. Avignone IIIA.S. BarabashF.E. BertrandA.W. BradleyV. BrudaninM. BuschM. BuuckJ. CajaM. CajaT.S. Caldwell  +58
The MAJORANA DEMONSTRATOR uses Ge detectors enriched to 88% in Ge-76 to search for neutrinoless double beta decay. To maximize recovery of costly enriched material, special processing was developed, achieving a 70% detector mass yield. Projections indicate 80–85% recovery if all byproducts, including acid etchant, are reprocessed—a critical factor for a future ton-scale experiment. All material was shielded from cosmic rays to reduce cosmogenic Ge-68, which would otherwise contribute background in the region of interest.
arXivarXiv · · July 19, 2017
0
The Majorana Demonstrator calibration system
N. AbgrallI.J. ArnquistF.T. Avignone IIIA.S. BarabashF.E. BertrandM. BoswellA.W. BradleyV. BrudaninM. BuschM. BuuckT.S. CaldwellC.D. Christofferson  +55
The Majorana Demonstrator calibrates its germanium detectors for neutrinoless double-beta decay searches by deploying radioactive line sources around the cryostats. The sources are stored outside the shielding during low-background measurements and are moved in and out by the data acquisition system without human intervention. This calibration system provides the event rates needed for pulse-shape cuts and energy calibration, and its design and implementation are described in detail.
arXivarXiv · · February 7, 2017
0
36
New limits on Bosonic Dark Matter, Solar Axions, Pauli Exclusion Principle Violation, and Electron Decay from the Majorana Demonstrator
N. AbgrallI.J. ArnquistF.T. Avignone IIIA.S. BarabashF.E. BertrandA.W. BradleyV. BrudaninM. BuschM. BuuckT.S. CaldwellY-D. ChanC.D. Christofferson  +55
Using 478 kg d of commissioning data from the Majorana Demonstrator, this work sets 90% confidence-level limits on several exotic keV-scale phenomena. The most stringent constraints on bosonic dark matter are for 11.8 keV particles: $g_{Ae} < 4.5\times 10^{-13}$ for pseudoscalars and $\alpha'/\alpha < 9.7\times 10^{-28}$ for vectors. Additional limits cover a 14.4 keV solar axion coupling, Pauli exclusion principle violating electron transitions, and electron decay into invisible channels with a lifetime exceeding $1.2\times 10^{24}$ yr.
arXivarXiv · · December 2, 2016
0
123
Search for Pauli Exclusion Principle Violating Atomic Transitions and Electron Decay with a P-type Point Contact Germanium Detector
N. AbgrallI.J. ArnquistF.T. Avignone IIIA.S. BarabashF.E. BertrandA.W. BradleyV. BrudaninM. BuschM. BuuckA.S. CaldwellY-D. ChanC.D. Christofferson  +57
Using 89.5 kg-d of data from a p-type point contact germanium detector, the authors search for K-alpha atomic transitions that violate the Pauli exclusion principle. No signal is observed, and a lower limit of $5.8 \times 10^{30}$ seconds at 90% C.L. is set on the transition lifetime. A similar search for the decay of a K-shell electron into neutrinos yields a lower limit of $6.8 \times 10^{30}$ seconds at 90% C.L. The planned MAJORANA DEMONSTRATOR could improve these limits tenfold over three years.
arXivarXiv · · October 19, 2016
0
34
Delayed charge recovery discrimination of passivated surface alpha events in P-type point-contact detectors
J. GruszkoN. AbgrallI.J. ArnquistF.T. Avignone IIIA.S. BarabashF.E. BertrandA.W. BradleyV. BrudaninM. BuschM. BuuckT.S. CaldwellY-D. Chan  +55
The Majorana Demonstrator, which searches for neutrinoless double-beta decay in $^{76}$Ge, faces a background from alpha particles that deposit energy on the passivated surface of its germanium detectors. These events produce a reduced prompt signal and a distinct change in the pulse tail slope because charges drift along the surface with reduced mobility. This paper presents a filter that identifies this delayed charge recovery, enabling efficient rejection of such alpha events.
arXivarXiv · · October 7, 2016
0
23
Initial Results from the MAJORANA DEMONSTRATOR
S.R. ElliottN. AbgrallI.J. ArnquistF.T. Avignone IIIA.S. BarabashF.E. BertrandA.W. BradleyV. BrudaninM. BuschM. BuuckT.S. CaldwellY-D. Chan  +55
The MAJORANA DEMONSTRATOR, an array of high-purity Ge detectors (44.8 kg total, 29.7 kg enriched in $^{76}$Ge) at the Sanford Underground Research Facility, aims to establish the background and scalability for a tonne-scale neutrinoless double-beta decay ($0\nu\beta\beta$) search in $^{76}$Ge. Initial results from Module 1, which began physics data production in early 2016 after a 2015 commissioning run, are presented, along with the status and potential physics reach of the full experiment. The second module is planned for completion by mid-2016.
arXivarXiv · · October 4, 2016
0
Background model for the MAJORANA DEMONSTRATOR
C. CuestaN. AbgrallI.J. ArnquistF.T. Avignone IIIA.S. BarabashF.E. BertrandA.W. BradleyV. BrudaninM. BuschM. BuuckT.S. CaldwellY-D. Chan  +55
The MAJORANA DEMONSTRATOR, with 44 kg of high-purity Ge detectors, targets a background rate at or below 1 count/(ROI·t·y) in the 4 keV region of interest around the Q-value of 2039 keV, a prerequisite for a future tonne-scale experiment probing the neutrino mass scale to ~15 meV. This goal is pursued through reducing radioactive impurities in construction materials and using pulse shape analysis from p-type point contact detectors. Background simulations constrained by radioassay measurements assess the effectiveness of these methods. Preliminary engineering-run results are presented.
arXivarXiv · · October 3, 2016
0
The Majorana Demonstrator search for neutrinoless double beta decay
C. CuestaM. Buuck…F.E. Bertrand
The MAJORANA DEMONSTRATOR, a 44.8-kg modular array of HPGe detectors (29.7 kg enriched >88% in ⁷⁶Ge), searches for neutrinoless double beta decay in ⁷⁶Ge. Its central contribution is to demonstrate that a background rate ≤1 count/tonne/year in the 4-keV region around the 2039-keV Q-value is achievable, thereby paving the way for tonne-scale experiments that could probe the inverted neutrino mass hierarchy. The modular design facilitates scaling to the next generation. First data are introduced.
arXivarXiv · · August 25, 2016
0
0
High voltage testing for the MAJORANA Demonstrator
N. AbgrallI.J. ArnquistF.T. Avignone IIIA.S. BarabashF.E. BertrandA.W. BradleyV. BrudaninM. BuschM. BuuckD. ByramA.S. CaldwellY-D. Chan  +61
The MAJORANA Demonstrator, a 44-kg HPGe detector array searching for neutrinoless double-beta decay in $^{76}$Ge, requires high-voltage (up to 5 kV) supply without surface micro-discharge that could damage electronics or mimic signals. Through R&D, the optimal cable layout and feedthrough flange design were determined, and every cable and feedthrough was characterized. A stable configuration was achieved, enabling discharge-free operation during commissioning.
arXivarXiv · · March 28, 2016
0
16
Frequent collaborators
H. Ejiri (51)
R. Henning (51)
K. Rielage (51)
M. Busch (50)
Yu. Efremenko (48)
M. Shirchenko (46)
Y-D. Chan (45)
V. Yumatov (45)
J. Gruszko (44)
S. Mertens (44)
W. Xu (44)
E. Yakushev (44)