MCP
FL

F. Levi

14 papers in the library

Papers

14
Measurement and control of the interaction frequency shift in bosonic optical lattice clocks
J. P. SalvatierraM. BarbieroG. BertainaD. CalonicoF. LeviM. G. Tarallo
This paper reports measurements of inter-level interactions in a bosonic optical lattice clock using $^{88}$Sr atoms. A nonlinear density dependence of the clock shift is observed without quantum degeneracy. In a 2D lattice, the Rabi line shape shows an interaction sideband consistent with a collective spin model, while in a 1D lattice density-induced dephasing modifies the shift. These findings enable operation at a net-zero systematic density shift in $^{88}$Sr lattice clocks, with implications for many-body physics and precision measurements.
arXivarXiv · · August 3, 2026
0
0
Multi-Machine Scaling Laws for Fuel and Impurity Puffing Rates Sufficient for Detachment Access: a Systematic Review of Magnetic Confinement Fusion Devices
M. MoscheniA. HerrmannR. KembletonM. KryjakS. LazersonF. LeviM. SiccinioP. StaniecT. GiegerichC. Tantosthe Gauss Fusion GmbH Team
From 457 experimental and numerical entries across 32 magnetic confinement devices, multi-machine scaling laws are derived for fuel and impurity puffing rates sufficient to achieve edge plasma detachment. The fuel scaling, $\Gamma_{\text{D}} \propto [n_{\text{sep}}\, a\, (S_{\text{div}}/V_{\text{div}})^{-1.5}]^{1.05}$, incorporates plasma opaqueness and is validated across all toroidal devices. A simplified H-mode form, $\Gamma_{\text{D}}^{\text{HDL}} \propto 0.43\, a^{1.58}\, \lambda_q^{-0.89}$, avoids explicit density dependence. The impurity seeding follows a general non-linear law, yielding the simplification $\Gamma_{\text{Z}}^{\text{GES}} \propto a^{1.51}\, \lambda_q^{-0.27}$. These macroscopic 0D laws link detachment access to engineering actuators, with validation against 40 plasmas showing agreement within a factor of 2 on average.
arXivarXiv · · July 28, 2025
0
3
Roadmap towards the redefinition of the second
N. DimarcqM. Gertsvolf…F. Levi
This paper presents the roadmap toward redefining the SI second, updated by the CCTF Task Force in 2020. It discusses the status of optical frequency standards, their contribution to time scales and UTC, comparison methods, and the required knowledge of Earth's gravitational potential. The mandatory criteria for redefinition and their current fulfilment level are described, along with options based on a single or a set of transitions.
arXivarXiv · · July 26, 2023
0
243
Direct comparisons of European primary and secondary frequency standards via satellite techniques
F. RiedelA. Al-Masoudi…F. Levi
This paper reports a 26-day comparison of five optical clocks and six atomic fountain clocks located at four European metrology institutes using two satellite-based frequency comparison techniques: TWSTFT and GPS PPP. With an enhanced statistical analysis procedure that accounts for correlations and gaps, combined overall uncertainties of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for optical clock comparisons were achieved. The fountain clock comparison showed a maximum relative frequency difference of $6.9 \times 10^{-16}$ with uncertainties of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$, demonstrating direct cross-border frequency comparisons at the $10^{-16}$ level.
arXivarXiv · · October 9, 2019
0
60
Measuring molecular frequencies in the 1--10 μm range at 11-digits accuracy
G. InseroS. BorriD. CalonicoP. Cancio PastorC. ClivatiD. D'AmbrosioP. De NataleM. InguscioF. LeviG. Santambrogio
This paper presents a mid-infrared spectroscopy setup that achieves 11-digit accuracy across the entire 1–10 μm range by combining a quantum cascade laser (QCL) with difference-frequency generation in an OP-GaP crystal, referenced to a primary frequency standard via a metrological fiber link. The authors demonstrate this performance by measuring a CO vibrational transition around 6 μm, obtaining precision four orders of magnitude better than the previous literature value.
arXivarXiv · · March 31, 2017
0
Synthetic dimensions and spin-orbit coupling with an optical clock transition
L. F. LiviG. CappelliniM. DiemL. FranchiC. ClivatiM. FrittelliF. LeviD. CalonicoJ. CataniM. InguscioL. Fallani
The paper reports a synthetic spin-orbit coupling method using a single-photon optical clock transition in $^{173}$Yb atoms. Electronic states are treated as sites along a synthetic dimension, forming fermionic ladders with tunable magnetic fluxes. Fiber-link-enhanced clock spectroscopy detects the spin-orbit coupling, and chiral edge currents are measured as a function of flux, offering a new route to topological states with ultracold gases.
arXivarXiv · · September 15, 2016
0
372
Measuring absolute frequencies beyond the GPS limit via long-haul optical frequency dissemination
C. ClivatiG. CappelliniL. LiviF. PoggialiM. Siciliani de CumisM. ManciniG. PaganoM. FrittelliA. MuraG. A. CostanzoF. LeviD. Calonico  +3
This work demonstrates that a 642-km optical fiber link to a remote primary cesium frequency standard can replace GPS for absolute frequency measurements, achieving precision beyond GPS limits without a local atomic clock. The setup stably addresses the $^1$S$_0$---$^3$P$_0$ clock transition in ultracold $^{173}$Yb, improving the reported transition frequency accuracy by two orders of magnitude.
arXivarXiv · · November 26, 2015
0
59
Beyond the fundamental noise limit in coherent optical fiber links
C. E. CalossoE. BertaccoD. CalonicoC. ClivatiG. A. CostanzoM. FrittelliF. LeviS. MicalizioA. MuraA. Godone
Active stabilization compensates most fiber-induced phase noise in coherent optical links, but the propagation delay leaves a fundamental "delay-unsuppressed" noise floor. This paper demonstrates a post-processing subtraction algorithm between the remote-end optical signal and the round-trip signal, achieving a 6 dB improvement beyond that fundamental limit. Experimental data from a 47 km metropolitan fiber link confirm the theoretical prediction, effectively doubling the resolution of remote optical clock comparisons.
arXivarXiv · · May 22, 2014
0
Coherent optical frequency transfer at 5e-19 over a doubled 642 km fiber link
D. CalonicoE. K. Bertacco…F. Levi
This paper demonstrates coherent optical frequency transfer over a 642 km fiber link, achieving a resolution of $3\times10^{-19}$ at 1000 s and an accuracy of $5\times10^{-19}$. The link performance is evaluated by doubling the path to 1284 km using a single fiber with a double round-trip technique, avoiding the need for a second fiber. The Allan deviation analysis is theoretically derived for the observed noise power spectrum, supporting the characterization of long-haul links for future continental frequency metrology networks.
arXivarXiv · · April 1, 2014
0
The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems
S. SchillerA. Görlitz…F. Levi
The Space Optical Clocks (SOC) project aims to install an optical lattice clock on the ISS, improving upon the ACES mission by at least one order of magnitude. As a precursor, the EU-funded SOC2 project (2011-2015) develops two transportable lattice optical clock demonstrators based on trapped neutral ytterbium and strontium atoms. These achieve a relative frequency instability below $1\times10^{-15}$ at 1 s and inaccuracy below $5\times10^{-17}$, representing improvements of about two and one orders over today's best transportable clocks. This paper presents the first year's results.
arXivarXiv · · June 17, 2012
0
49
Bayesian estimate of the zero-density frequency of a Cs fountain
D CalonicoF LeviL LoriniG Mana
The paper presents a Bayesian analysis that estimates the zero-density frequency of a Cs fountain clock by incorporating the known sign of the collisional coefficient as prior knowledge. Compared to the orthodox analysis, this method reduces the uncertainty of the frequency estimate by 28% when applied to data from the INRIM caesium fountain, demonstrating its value in primary frequency metrology.
arXivarXiv · · July 28, 2009
0
Bayesian inference of a negative quantity from positive measurement results
D CalonicoF LeviL LoriniG Mana
This paper applies Bayesian inference to assign a probability density to a quantity that is known to be negative, based on positive measurement results. The analysis yields a posterior density that is logically consistent with both positive and negative measurement outcomes, and is used to estimate the atom density shift in a caesium fountain clock. The advantages of this Bayesian approach for the realization of the time unit are discussed.
arXivarXiv · · February 17, 2009
0
Black Body Radiation Shift of the 133Cs Hyperfine Transition Frequency
S. MicalizioA. GodoneD. CalonicoF. LeviL. Lorini
This paper theoretically evaluates the static scalar polarizability of the $^{133}$Cs ground state and the black-body radiation (BBR) shift of the hyperfine transition frequency (with $m_F=0$). The computed polarizability is $\alpha_0 = 6.600(16) \times 10^{-39} \,\mathrm{C\,m^2/V}$, agreeing with recent results at the $10^{-3}$ level. The relative BBR shift at $300\,\mathrm{K}$ is $\beta = -1.49(7) \times 10^{-14}$, which is $2 \times 10^{-15}$ lower than the previously accepted value derived from dc-Stark measurements.
arXivarXiv · · October 17, 2003
0
Measurement of the Blackbody Radiation Shift of the 133Cs Hyperfine Transition in an Atomic Fountain
F. LeviD. CalonicoL. LoriniS. MicalizioA. Godone
The authors report a measurement of the blackbody radiation shift of the cesium ground-state hyperfine transition (9.2 GHz) using an atomic fountain frequency standard. The measured relative shift at 300 K is $(-1.43 \pm 0.11) \times 10^{-14}$, which agrees with their theoretical evaluation $(-1.49 \pm 0.07) \times 10^{-14}$ but differs from the previously accepted value $(-1.69 \pm 0.04) \times 10^{-14}$. This discrepancy has implications for the accuracy of frequency standards and high-precision physics tests.
arXivarXiv · · October 13, 2003
0
Frequent collaborators
D. Calonico (11)
C. Clivati (5)
G. A. Costanzo (4)
M. Frittelli (4)
A. Godone (4)
J. Lodewyck (3)
M. Inguscio (3)
A. Mura (3)
S. Micalizio (3)
E. Peik (2)
I. Sesia (2)
H. S. Margolis (2)