MCP
FP

F. Proebst

14 papers in the library

Papers

14
Optimization studies of silicon remoTES cryogenic calorimeters
G. AngloherM. R. Bharadwaj…F. Proebst
This paper reports optimization studies of silicon remoTES cryogenic calorimeters, a design where the Transition Edge Sensor (TES) is on a separate chip thermally coupled to the absorber via a gold link. By testing a new Au link design and three phonon collector configurations (Au, Cu, and Al/Au), the authors reduced thermal boundary resistance and improved signal transmission. The best configuration, Al/Au, achieved a baseline resolution of $(21.5 \pm 0.3)\,$\mathrm{eV}$.
arXivarXiv · · August 10, 2026
0
0
The SWEET project: probing sugar crystals for direct dark matter searches
A. BentoF. Casadei…F. Proebst
This paper presents the first results from a sugar-based phonon detector using sucrose crystals (C₁₂H₂₂O₁₁) for direct dark matter searches. The detector operates at cryogenic temperatures and detects particles through associated scintillation light. Hydrogen-rich sucrose offers favorable kinematics for sub-GeV/c² dark matter masses, making it a promising target material for improved sensitivity in low-mass dark matter detection.
arXivarXiv · · September 29, 2025
0
The CRESST experiment: towards the next-generation of sub-GeV direct dark matter detection
G. AngloherS. Banik…F. Proebst
The CRESST experiment upgrade will deploy about 100 detectors with masses from 2g to 24g to achieve unprecedented sensitivity to sub-GeV dark matter particles, focusing on spin-independent dark matter-nucleus scattering. The paper presents the experimental strategies, projected sensitivities, and approaches to mitigate low-energy excess backgrounds, which have been a key limitation in previous sub-GeV searches. A long-term roadmap for the next decade is also outlined.
arXivarXiv · · May 2, 2025
0
12
Detector development for the CRESST experiment
G. AngloherS. Banik…F. Proebst
The CRESST-III dark matter search faces a low-energy background that rises sharply below 200 eV, limiting its physics reach. To investigate this unexplained signal, the collaboration developed three new detector layouts. These designs are presented as a step toward understanding the background's origin and improving the sensitivity of low-mass dark matter direct detection.
arXivarXiv · · November 13, 2023
0
17
Deep-underground dark matter search with a COSINUS detector prototype
COSINUS CollaborationG. Angloher…F. Proebst
The COSINUS collaboration reports the first underground operation of a NaI cryogenic calorimeter read out via the remoTES scheme, achieving a five-fold improvement in nuclear recoil baseline resolution ($\sigma = 441$ eV) and enhanced $e^-/\gamma$ event discrimination. Using a 3.67 g NaI absorber with a silicon light detector, the experiment set a spin-independent dark-matter nucleon cross-section limit of $\mathcal{O}$(pb) with only 11.6 g d exposure, demonstrating progress toward a model-independent test of the DAMA/LIBRA modulation signal.
arXivarXiv · · July 20, 2023
0
40
New limits on the resonant absorption of solar axions obtained with a 169^{169}Tm-containing cryogenic detector
A. H. AbdelhameedS. V. Bakhlanov…F. Proebst
Using a cryogenic Tm$_3$Al$_5$O$_{12}$ bolometer, this work searches for resonant absorption of solar axions by $^{169}$Tm nuclei. The 8.18 g crystal operated for 6.6 days yields improved limits on the axion–photon and axion–electron coupling combinations: $|g_{A\gamma} (g_{AN}^0 + g_{AN}^3) \leq 1.44 \times 10^{-14}$ GeV$^{-1}$ and $|g_{Ae} (g_{AN}^0 + g_{AN}^3) \leq 2.81 \times 10^{-16}$.
arXivarXiv · · April 17, 2020
0
The CRESST II Dark Matter Search
Leo StodolskyG. Angloher…F. Proebst
Reporting on the CRESST II dark matter search, this paper presents preliminary results from 730 kg-days of data using cryogenic detectors. It emphasizes the possibility of identifying the recoil nucleus to distinguish signal from background. Key backgrounds and methods for their identification and mitigation are discussed.
arXivarXiv · · March 30, 2012
0
18
Brittle fracture down to femto-Joules - and below
J. AstromP. Di StefanoF. ProebstL. StodolskyJ. Timonen
By analyzing energy-release data from stress-induced brittle fracture in pure sapphire at near-zero temperature, the authors find that the waiting-time distribution matches that of rock fracture and earthquakes. Despite strong time correlations and large-event precursors, simple prediction algorithms succeed only in a weak probabilistic sense. The work also discusses prospects for cryogenic experiments approaching single-bond sensitivity to investigate a possible transition-stress regime.
arXivarXiv · · August 31, 2007
0
Interpretation of Light-Quenching Factor Measurements
I. BavykinaP.ChristP.HuffJ.NinkovicF.ProebstW.SeidelL. Stodolsky
Light-quenching factors for ions in CaWO$_4$, reported for dark-matter detectors, are reinterpreted as a saturation effect. The light output is proportional to track length, independent of ion type and energy, matching the high dE/dx limit of Birk's law. This yields a simple model for the intrinsic resolution of low-energy ion detectors.
arXivarXiv · · July 5, 2007
0
Fracture Processes Observed with A Cryogenic Detector
J. AstromP.C.F. Di StefanoF.ProebstL.StodolskyJ.TimonenC.BucciS.CooperC.CozziniF.v. FeilitzschH.KrausJ.MarcheseO.Meier  +6
Using cryogenic sapphire detectors originally built for the CRESST dark-matter search, the authors report the first direct, event-by-event measurement of energy release in microscopic fracture events, with a sensitivity equivalent to breaking only a few hundred covalent bonds. The energy distribution follows a power law $dN/dE\propto E^{-\beta}$, similar to earthquakes; waiting-time distributions show power-law behavior at short intervals and exponential decay at long ones; and autocorrelations reveal time clustering lasting up to an hour.
arXivarXiv · · April 21, 2005
0
77
Detection of the Natural Alpha Decay of Tungsten
C. CozziniG. Angloher…F. Proebst
The natural alpha decay of $^{180}\mathrm{W}$ has been unambiguously detected for the first time using CRESST cryogenic detectors that simultaneously measure phonon and light signals, enabling a background-free spectrum. The measured half-life is $T_{1/2} = (1.8 \pm 0.2) \times 10^{18}$ years, with an energy release of $Q = (2516.4 \pm 1.1\,\mathrm{stat.} \pm 1.2\,\mathrm{sys.})\,\mathrm{keV}$. New limits are also set on the half-lives of other natural tungsten isotopes.
arXivarXiv · · August 6, 2004
0
A Textured Silicon Calorimetric Light Detector
P. C. F. Di StefanoT. FrankG. AngloherM. BruckmayerC. CozziniD. HauffF. ProebstS. RutzingerW. SeidelL. StodolskyJ. Schmidt
This paper adapts the photovoltaic texturing technique to cryogenic silicon calorimetric light detectors, reducing reflectivity and increasing absorption for random-incidence photons. The resulting energy resolution, limited by the position dependence of athermal-phonon collection, scales with the surface-to-volume ratio. For use with a $\mathrm{CaWO_4}$ scintillator, the calorimeter's time constants should match the slow light-emission of the crystal.
arXivarXiv · · July 7, 2003
0
The CRESST Experiment: Recent Results and Prospects
P. Di StefanoM. Bruckmayer…F. Proebst
The CRESST experiment uses cryogenic calorimeters to detect WIMPs via nuclear recoil phonons. A main background from microscopic crystal fracturing has been eliminated, improving the low-energy background rate by up to three orders of magnitude, leaving about one count per day per kg per keV above 10 keV recoil energy. This residual background is dominated by radioactivity, and future scintillating calorimeters measuring both light and phonons will reject most of it.
arXivarXiv · · November 20, 2000
0
7
Discrimination between Nuclear Recoils and Electron Recoils by Simultaneous Detection of Phonons and Scintillation Light
P. MeunierM. BravinM. BruckmayerS. GiordanoM. LoidlO. MeierF. ProebstW. SeidelM. SistiL. StodolskyS. UchaikinL. Zerle
We present a detector that discriminates nuclear recoils from electron recoils by simultaneously measuring phonons and scintillation light. It consists of a cryogenic CaWO$_4$ calorimeter (6 g, 12 mK) and a second calorimeter for the light. At energies above 15 keV, nuclear recoils are identified with a 99.7% suppression of electron recoils, enabling background rejection for the CRESST dark-matter WIMP search.
arXivarXiv · · June 8, 1999
0
Frequent collaborators
F. Petricca (8)
D. Hauff (8)
L. Stodolsky (8)
G. Angloher (7)
M. Mancuso (6)
F. Reindl (5)
K. Schaeffner (5)
A. Bento (5)
C. Bucci (5)
J. Jochum (5)
W. Seidel (5)
S. Fichtinger (4)