MCP
FS

F. Silva

10 papers in the library

Papers

10
Ultrasensitive measurement of phase dynamics by time-holographic dark-port readout of a marginally imbalanced interferometer
F. SilvaA. MolinaA. Esteban-MartínJ. García-MonrealG. J. de Valcárcel
This paper shows that reading out the complex dark-port field of a marginally imbalanced interferometer, rather than optical power, yields steep phase sensitivity near destructive interference. For small arm-amplitude imbalance $\mu$, the dark-port phase tangent reduces to $T_{\textrm{out}}=\mu^{-1}\phi_{\textrm{in}}$, defining a magnification $M=\mu^{-1}$ that stays linear over $|\phi_{\textrm{in}}|\lesssim\sqrt{|\mu|}$, larger than the imbalance itself when $|\mu|\ll1$. Optical time-domain holography and Fourier demodulation synthesize $T_{\textrm{out}}$, a heterodyne readout intrinsically immune to laser relative-intensity noise at any magnification. An unoptimized, non-isolated Mach--Zehnder experiment demonstrates $|M|>10^3$ and optical-path resolution better than $\lambda/100{,}000$ (about 5 pm), with a shot-noise floor orders of magnitude below the environment-limited value.
arXivarXiv · · November 20, 2026
0
Demonstration of a 10-metre-long discharge plasma source for plasma wakefield acceleration
C. AmoedoN. LopesN. E. TorradoF. SilvaP. MuggliL. VerraM. TurnerG. Zevi Della PortaM. BergamaschiA. ClairembaudJ. MezgerF. Pannell  +4
The paper reports the first experimental validation of a 10-metre-long pulsed-DC discharge plasma source (DPS) for plasma wakefield acceleration. The DPS, tested at AWAKE with He, Ar, and Xe, produces electron densities of $10^{14}$ to $10^{15}$ cm$^{-3}$ and supports proton bunch self-modulation. The modulation frequency, used as a beam-based density diagnostic, agrees with interferometry and shows event-to-event reproducibility within 0.63%, comparable to the existing laser-ionised vapour source. This establishes the DPS as a viable alternative for long, uniform plasma sources with straightforward density control via discharge-beam timing.
arXivarXiv · · September 8, 2026
0
0
Measurement of the emittance of accelerated electron bunches at the AWAKE experiment
D. A. CookeF. Pannell…F. Silva
The AWAKE experiment at CERN performed a proof-of-principle measurement of the vertical-plane transverse emittance of plasma-wakefield-accelerated electron bunches using its existing spectrometer. The measured geometric emittance was about $0.5\,\text{mm}\,$mrad, several times larger than the injection beam's $0.08\,\text{mm}\,$mrad, consistent with expected growth from plasma density ramps and the large injection beam size. The analysis validated the technique and discussed necessary spectrometer improvements for future runs, which require sensitivity down to roughly $10^{-4}\,\text{mm}\,$mrad.
arXivarXiv · · November 13, 2024
0
6
Inline self-diffraction dispersion-scan of over octave-spanning pulses in the single-cycle regime
M. CanhotaF. SilvaR. WeigandH. M. Crespo
This paper presents an inline self-diffraction dispersion-scan (SD d-scan) for measuring over-octave-spanning sub-4-fs pulses in the single-cycle regime. The method's efficiency is derived theoretically and compared with the spectral response from the d-scan algorithm. Experimental results are validated against second-harmonic generation d-scan. The SD d-scan offers a robust inline setup and extends measurement capability to wavelength ranges, such as the ultraviolet, beyond the reach of SHG crystals.
arXivarXiv · · March 3, 2017
0
Experimental demonstration of phase bistability in a broad area optical oscillator with injected signal
R. Martínez-LorenteA. Esteban-MartínE. RolánK. StaliunasG. J. de ValcárcelF. Silva
Experiments on a broad-area photorefractive oscillator with a spatially modulated injected signal demonstrate phase bistability. The injection phase alternates periodically between two values differing by $\pi$, causing the output to display two-phase patterns. This confirms the technique proposed by de Valcárcel and Staliunas.
arXivarXiv · · October 4, 2016
0
3
Making of a nonlinear optical cavity
R. Martínez-LorenteG.J. de ValcárcelA. Esteban-MartínJ. García-MonrealE. RoldánF. Silva
This paper provides a detailed guide to constructing a photorefractive oscillator (PRO), a laser-pumped nonlinear optical cavity. The specific PRO is based on a Fabry-Perot cavity operating in a non-degenerate four-wave mixing configuration. Its output exhibits laser-like phase invariance, and the authors demonstrate that a suitably modulated injected beam can convert this phase-invariant output into a phase-bistable one. The emphasis is on the construction and measurement procedures, with supporting introductions to the photorefractive effect and nonlinear dynamics for self-containedness.
arXivarXiv · · October 4, 2016
0
1
0.5 keV soft X-ray attosecond continua
S. M. TeichmannF. SilvaS. L. CousinM. HemmerJ. Biegert
By exploiting a transient phase-matching regime, the authors generate carrier-envelope-controlled soft X-ray supercontinua spanning the entire water window (>200 eV). The pulses reach energies of 2.9±0.1 pJ and a flux of (7.3±0.1)×10⁷ photons/s, with a 13-attosecond transform limit. This work provides experimentally demonstrated attosecond pulses at energies sufficient to probe fundamental absorption edges of materials, enabling element-specific electronic dynamics. The advance bridges ultrafast temporal resolution with elemental selectivity, a key step toward real-time interrogation of charge dynamics in matter.
arXivarXiv · · April 3, 2016
0
Continuous spectra in high-harmonic generation driven by multicycle laser pulses
W. HolgadoC. Hernández-GarcíaB. AlonsoM. MirandaF. SilvaL. PlajaH. CrespoI. J. Sola
By using 4–7 fs pulses focused on a Kr gas jet, the authors observe continuous XUV spectra in the 20–37 eV region from high-harmonic generation. The continuum arises from coherent control of the relative delays and phases of individual attosecond pulses, achieved by adjusting the driving chirp and interaction geometry. Under negative chirp and appropriate phase matching, interpulse interference produces a continuum through both microscopic and macroscopic contributions. This method enables synthesizing XUV continua with multicycle pulses, without requiring isolated attosecond bursts.
arXivarXiv · · April 15, 2015
0
17
Multi-octave supercontinuum from mid-IR filamentation in bulk
F. SilvaD. AustinA. ThaiM. BaudischM. HemmerA. CouaironJ. Biegert
This paper demonstrates a broadband supercontinuum generated by femtosecond mid-infrared (MIR) pulse filamentation in bulk material under anomalous dispersion. The spectrum spans more than three octaves, from just above the ultraviolet deep into the MIR, with high spectral energy density (3 pJ to 10 nJ per nanometer), high shot-to-shot reproducibility, and carrier-to-envelope phase (CEP) stability. This method provides a simple, compact, and "all-in-one" source covering UV to MIR in a single filament, without complicated pulse splitting.
arXivarXiv · · October 25, 2011
0
Engineered arrays of NV color centers in diamond based on implantation of CN- molecules through nanoapertures
P. SpinicelliA. DréauL. RondinF. SilvaJ. AchardS. XavierS. BansropunT. DebuisschertS. PezzagnaJ. MeijerV. JacquesJ.-F. Roch
The paper reports a method to engineer arrays of NV color centers in diamond at the nanoscale. NV defects are produced in parallel by implanting CN- molecules through 80 nm diameter apertures patterned in a PMMA layer via electron beam lithography. Using CN- molecules increases the NV formation yield. The method may enable solid-state coupled-spin arrays and positioning of optically active NV centers on photonic microstructures.
arXivarXiv · · August 9, 2010
0
2
Frequent collaborators
A. Esteban-Martín (3)
J. García-Monreal (2)
G. J. de Valcárcel (2)
C. Amoedo (2)
N. Lopes (2)
L. Verra (2)
G. Zevi Della Porta (2)
M. Bergamaschi (2)
A. Clairembaud (2)
J. Mezger (2)
F. Pannell (2)
E. Gschwendtner (2)