MCP
GB

G. Bison

44 papers in the library

Papers

30
New high-sensitivity search for neutron to mirror-neutron oscillations at the PSI UCN source
N. J. AyresZ. BerezhianiG. BisonK. BodekV. BondarP. -J. ChiuM. DaumC. B. DoorenbosS. EmmeneggerK. KirchV. KletzlJ. Krempel  +10
A collaboration at the Paul Scherrer Institute performed a high-sensitivity search for neutron to mirror-neutron (n-n') oscillations using a dedicated apparatus and the PSI UCN source. By analyzing neutron losses under magnetic fields from 5 to 109 microT with field mapping and Monte Carlo simulations, no evidence of oscillations was found. New limits on the oscillation time constant exclude the previously claimed parameter space to 99.98% confidence.
arXivarXiv · · February 26, 2026
0
Simulation and optimization of the Active Magnetic Shield of the n2EDM experiment
N. J. AyresG. BanG. BisonK. BodekV. BondarT. BouillaudG. L. CaratschE. ChanelW. ChenC. CrawfordV. CzamlerC. B. Doorenbos  +38
The n2EDM experiment searches for the neutron electric dipole moment using passive shielding and an Active Magnetic Shield (AMS) of eight coils on an irregular grid. The AMS suppresses external disturbances up to ±50 μT (homogeneous) and ±5 μT/m (gradients) to a few μT. This work presents a finite-element simulation of AMS fields inside the magnetically shielded room, accurate enough to match measurements. The simulation is demonstrated by optimizing the number and placement of feedback sensors with a genetic algorithm.
arXivarXiv · · January 30, 2026
0
Ultracold neutron energy spectrum and storage properties from magnetically induced spin depolarization
N. J. AyresG. BanG. BisonK. BodekV. BondarT. BouillaudD. BowlesG. L. CaratschE. ChanelW. ChenP. -J. ChiuC. B. Crawford  +44
This paper presents a method to extract the energy spectrum of ultracold neutrons from magnetically induced spin depolarization measurements in the n2EDM apparatus. The approach also distinguishes specular from diffuse wall collisions, as demonstrated by comparing two storage chambers. The method is validated against an independent magnetic-filter measurement, and the extracted spectrum is used to compute the neutron center-of-mass offset, a key systematic effect for neutron electric dipole moment searches.
arXivarXiv · · November 10, 2025
0
Temperature dependent ultracold neutron transmission in D2_2 gas −- a test of the Young-Koppel model
G. BisonR. GrössleK. KirchB. LaussF. PriesterI. RienäckerG. Zsigmond
This paper reports the first experimental test of the Young-Koppel model for ultracold neutron (UCN) scattering in gaseous D$_2$ over a wide temperature range. The results validate the YK model while revealing a significant discrepancy with the low-energy low-temperature approximation (LETA) for D$_2$, though LETA remains valid for monoatomic gases like Ne. Cross sections for other noble gases are also confirmed. A more limited measurement in H$_2$ gas further supports the YK prediction.
arXivarXiv · · September 26, 2024
0
Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments
N. J. AyresG. BanG. BisonK. BodekV. BondarT. BouillaudD. BowlesE. ChanelW. ChenP.-J. ChiuC. B. CrawfordO. Naviliat-Cuncic  +38
The paper reports a degaussing procedure for the magnetically shielded room (MSR) of the n2EDM experiment that halves the residual magnetic field. With the full coil system and vacuum vessel installed, the field inside the ~1.4 m³ volume is reduced below 300 pT and made more uniform. The procedure is also faster and generates less heat, cutting the thermal relaxation time from 12 h to ~1.5 h.
arXivarXiv · · September 28, 2023
0
A large 'Active Magnetic Shield' for a high-precision experiment
C. AbelN.J. AyresG. BanG. BisonK. BodekV. BondarT. BouillaudE.ChanelJ. ChenW. ChenP.-J. ChiuC.B. Crawford  +39
The paper presents the design and implementation of a large Active Magnetic Shield (AMS) for the n2EDM neutron electric dipole moment experiment. The AMS, a system of eight feedback-controlled coils on an irregular grid around a 5m cubic magnetically shielded room, compensates static and variable magnetic fields up to ±50 μT (homogeneous) and ±5 μT (first-order gradients), suppressing them to a few μT in the sub-Hertz range. This fulfills the experiment's stringent stability requirements while remaining compact for spatial constraints.
arXivarXiv · · July 14, 2023
0
Search for an interaction mediated by axion-like particles with ultracold neutrons at the PSI
N. J. AyresG. BisonK. BodekV. BondarT. BouillaudE. ChanelP.-J. ChiuB. ClementC. B. CrawfordM. DaumC. B. DoorenbosS. Emmenegger  +35
This paper reports a search for a short-range, spin-dependent interaction mediated by axion-like particles, using ultracold neutrons stored in vacuum near material surfaces. The dominant systematic uncertainty from magnetic-field gradients was controlled to about 4 pT/cm. No new interaction was found, and a new limit on the monopole-dipole coupling $g_s g_p \lambda^2 < 8.3 \times 10^{-28}\,\text{m}^2$ (95% C.L.) was set for force ranges $5\,\mu\text{m} < \lambda < 25\,\text{mm}$, improving the previous limit by a factor of 2.7 and providing the current tightest constraint obtained with free neutrons.
arXivarXiv · · March 31, 2023
0
Search for ultralight axion dark matter in a side-band analysis of a 199Hg free-spin precession signal
C. AbelN. J. AyresG. BanG. BisonK. BodekV. BondarE. ChanelC. B. CrawfordM. DaumB. DechenauxS. EmmeneggerP. Flaux  +26
This paper reports a null result from a demonstration experiment that searched for ultralight axion dark matter by looking for a frequency modulation in the free spin-precession signal of $^{199}$Hg in a $1\,\mathrm{\mu T}$ magnetic field. The axion would produce an oscillating pseudo-magnetic field via its coupling to nuclear spins. The search covers axion masses $10^{-16}\,\mathrm{eV} \lesssim m_a \lesssim 10^{-13}\,\mathrm{eV}$ and achieves a peak sensitivity to the axion-nucleon coupling $g_{aNN} \approx 3.5 \times 10^{-6}\,\mathrm{GeV}^{-1}$.
arXivarXiv · · December 2, 2022
0
22
The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements
N.J. AyresG. BanG. BisonK. BodekV. BondarT. BouillaudB. ClementE. ChanelP.-J. ChiuC. B. CrawfordM. DaumC. B. Doorenbos  +32
The n2EDM experiment's magnetically shielded room (MSR) provides a 2.92m-sided cubic interior (25m³) with 87 openings for apparatus and intermediate space for electronics. Characterization shows a remanent magnetic field below 100pT in the central 1m³ and below 600pT throughout the entire inner volume, with a quasi-static shielding factor of about 100,000 at 0.01Hz across all spatial directions, increasing to 10^8 above 1Hz.
arXivarXiv · · June 21, 2022
0
Improved search for neutron to mirror-neutron oscillations in the presence of mirror magnetic fields with a dedicated apparatus at the PSI UCN source
N.J.AyresZ.BerezhianiR.BiondiG.BisonK.BodekV.BondarP.-J.ChiuM.DaumR.T.DinaniC.B.DoorenbosS.EmmeneggerK.Kirch  +13
This paper presents a new search for neutron to mirror-neutron ($n-n'$) oscillations using ultracold neutrons stored in a large 1.47 m$^3$ vessel at PSI, designed to test for anomalous loss as a function of applied magnetic field $B$. The experiment will reach sensitivity to oscillation times $\tau_{nn'}/\sqrt{\cos(\beta)}$ above one hundred seconds, scanning $B$ to confirm or exclude previously reported potential signals, where $\beta$ is the angle between the mirror magnetic field $B'$ and $B$.
arXivarXiv · · October 31, 2021
0
Ultracold neutron storage and transport at the PSI UCN source
G. BisonM. DaumK. KirchB. LaussD. RiesP. Schmidt-WellenburgG. Zsigmond
This paper reports absolute ultracold neutron (UCN) transport efficiency measurements at the PSI UCN source, completing a series of source-characterization studies. Two complementary measurements were performed: one on height-dependent UCN density, and another on the transmission of a calibrated UCN quantity over a ~16 m guide connecting two beamports via the source storage vessel. Together with Monte Carlo simulations, these enable quantification and optimization of guide-system performance.
arXivarXiv · · October 25, 2021
0
Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments
N. J. AyresG. BanG. BisonK. BodekV. BondarP.-J. ChiuB. ClementC. B. CrawfordM. DaumS. EmmeneggerM. FertlA. Fratangelo  +28
This paper presents the first dedicated study of magnetic Johnson-Nyquist noise (JNN) from metal electrodes in neutron electric-dipole-moment (nEDM) experiments. The authors derive surface- and volume-averaged RMS noise amplitudes for a cylindrical geometry and model noise as current dipoles to simulate spatial and temporal JNN dependencies. Applying these to the n2EDM apparatus, they show that JNN does not limit the $^{133}$Cs and $^{199}$Hg co-magnetometers and that its impact is negligible for nEDM searches down to $4\times 10^{-28}\,e\cdot\mathrm{cm}$ per measurement, making solid aluminum electrodes viable.
arXivarXiv · · February 2, 2021
0
The design of the n2EDM experiment
N. J. AyresG. BanL. BienstmanG. BisonK. BodekV. BondarT. BouillaudE. ChanelJ. ChenP.-J. ChiuB. ClémentC. Crawford  +49
n2EDM, a next-generation experiment under construction at PSI, targets a neutron electric dipole moment with an order-of-magnitude better sensitivity than its predecessor. The design overview covers the experimental method, setup, sensitivity requirements, and technical implementation, with provisions for further substantial improvements.
arXivarXiv · · January 21, 2021
0
A search for neutron to mirror-neutron oscillations
C. AbelN. J. AyresG. BanG. BisonK. BodekV. BondarE. ChanelP.-J. ChiuC. CrawfordM. DaumR. T. DinaniS. Emmenegger  +31
The neutron electric dipole moment collaboration performed a dedicated search for neutron to mirror-neutron oscillations at the Paul Scherrer Institute, finding no evidence. New lower limits on the oscillation time $\tau_{nn'}$ were set: $\tau_{nn'} > 352$ s at $B'=0$ (95% C.L.), $\tau_{nn'} > 6$ s for all $0.4~\mu\text{T} < B' < 25.7~\mu\text{T}$ (95% C.L.), and $\tau_{nn'}/\sqrt{\cos\beta} > 9$ s for all $5.0~\mu\text{T} < B' < 25.4~\mu\text{T}$ (95% C.L.), where $\beta$ is the fixed angle between the applied and local mirror magnetic fields. These are the best constraints measured around $B' \sim 10~\mu$T and $B' \sim 20~\mu$T.
arXivarXiv · · September 23, 2020
0
Measurement of the permanent electric dipole moment of the neutron
C. AbelS. AfachN. J. AyresC. A. BakerG. BanG. BisonK. BodekV. BondarM. BurghoffE. ChanelZ. ChowdhuriP.-J. Chiu  +72
We report a neutron electric dipole moment (EDM) measurement at the Paul Scherrer Institute using Ramsey's method with ultracold neutrons. The experiment employed a $^{199}$Hg co-magnetometer and cesium magnetometer array to control magnetic field changes. The result, $d_n = (0.0 \pm 1.1_{\text{stat}} \pm 0.2_{\text{sys}}) \times 10^{-26} e\,\text{cm}$, is consistent with zero and constrains time-reversal-violating physics beyond the Standard Model.
arXivarXiv · · January 31, 2020
0
1k+
Neutron optics of the PSI ultracold neutron source: characterization and simulation
G.BisonB.BlauM.DaumL.GöltlR.HenneckK.KirchB.LaussD.RiesP.Schmidt-WellenburgG.Zsigmond
This paper presents the characterization and simulation of the ultracold neutron (UCN) source at the Paul Scherrer Institute. The central contribution is a detailed simulation model of the source, which is used to analyze measurements of key parameters—such as emptying times, storage times, and transmission probabilities—that define the UCN intensity delivered at beamports. The model enables extraction of crucial surface parameters, providing a foundation for future source improvements to advance high-intensity fundamental physics experiments.
arXivarXiv · · July 12, 2019
0
nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset
C. AbelN. J. AyresG. BanG. BisonK. BodekV. BondarE. ChanelP.-J. ChiuM. DaumS. EmmeneggerL. Ferraris-BouchezP. Flaux  +31
This paper reports the data-taking strategy for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute, using ultracold neutrons stored in a single chamber. The magnetic field, monitored by a mercury cohabiting magnetometer and cesium magnetometers, was precisely controlled with field coils. The approach balances statistical sensitivity and systematic effect control, achieving an irreducible sensitivity better than $1 \times 10^{-26}$ ecm.
arXivarXiv · · November 9, 2018
0
The n2EDM experiment at the Paul Scherrer Institute
C. AbelN. J. AyresG. BanG. BisonK. BodekV. BondarE. ChanelP.-J. ChiuB. ClementC. CrawfordM. DaumS. Emmenegger  +36
The n2EDM experiment at the Paul Scherrer Institute is a new spectrometer for measuring the neutron electric dipole moment (nEDM) at room temperature in vacuum using ultracold neutrons. Its design features a large double storage chamber and neutron transport optimized for the PSI UCN source. Building on the previous apparatus, the new setup is calculated to achieve an order of magnitude improvement in sensitivity.
arXivarXiv · · November 6, 2018
0
Statistical sensitivity of the nEDM apparatus at PSI to neutron mirror-neutron oscillations
C. AbelN. AyresG. BisonK. BodekV. BondarP.-J. ChiuM. DaumS. EmmeneggerP. FlauxL. Ferraris-BouchezW. C. GriffthN. Hild  +24
The nEDM collaboration at PSI conducted a new search for neutron–mirror-neutron ($n-n'$) oscillations, a hypothetical mixing process faster than neutron beta decay. Run configurations were chosen with filling time 29 s, storage times 180 s and 380 s, and applied magnetic fields of 10 µT and 20 µT to overlap with previous efforts and improve sensitivity. The normalization technique and magnetic field characterization required for the experiment are described. The resulting statistical sensitivity is comparable to the leading constraints on $n-n'$ oscillations.
arXivarXiv · · November 5, 2018
0
Solid deuterium surface degradation at ultracold neutron sources
A.AnghelT.L.BaileyG.BisonB.BlauL.J.BroussardS.M.ClaytonC.Cude-WoodsM.DaumA.HawariN.HildP.HuffmanT.M.Ito  +18
Solid deuterium (sD$_2$) is a key converter for ultracold neutrons (UCN), but UCN yield decreases with operation time after initial conditioning. This work shows that, beyond bulk quality, the surface quality of sD$_2$ is essential. Observations and simulations indicate that under pulsed operation, D$_2$ frost accumulates on the surface, causing strong albedo reflections that reflect UCN back into the solid where they are lost. The finding is supported by yield measurements, temperature/pressure data, and optical studies of frost formation, giving a consistent explanation of the yield degradation.
arXivarXiv · · April 23, 2018
0
42
Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches
G. BanG. BisonK. BodekM. DaumM. FertlB. FrankeZ. D. GrujićW. HeilM. HorrasM. KasprzakY. KermaidicK. Kirch  +22
The paper demonstrates a laser-based $^{199}$Hg co-magnetometer for neutron electric dipole moment searches. Compared to a $^{204}$Hg discharge lamp, the laser readout increases the signal-to-noise ratio by a factor of over five. An improved data model consistently describes both laser- and lamp-based measurements, explaining the performance gain. The laser magnetometer meets the sensitivity requirements for next-generation nEDM experiments.
arXivarXiv · · April 16, 2018
0
Search for axion-like dark matter through nuclear spin precession in electric and magnetic fields
C. AbelN.J. AyresG. BanG. BisonK. BodekV. BondarM. DaumM. FairbairnV.V. FlambaumP. GeltenbortK. GreenW.C. Griffith  +36
This paper reports a search for axion-like dark matter by measuring the ratio of spin-precession frequencies of ultracold neutrons and $^{199}$Hg atoms in electric and magnetic fields. No signal was observed for axion masses $10^{-24}~\textrm{eV} \le m_a \le 10^{-17}~\textrm{eV}$. The null result provides the first laboratory constraints on the coupling of axion dark matter to gluons, improving on astrophysical limits by up to three orders of magnitude, and improves on previous laboratory constraints on the axion–nucleon coupling by up to a factor of 40.
arXivarXiv · · August 21, 2017
0
Comparison of ultracold neutron sources for fundamental physics measurements
G. BisonM. DaumK. KirchB. LaussD. RiesP. Schmidt-WellenburgG. ZsigmondT. BrennerP. GeltenbortT. JenkeO. ZimmerM. Beck  +11
This paper experimentally compares leading ultracold neutron (UCN) sources for fundamental physics, focusing on the search for a neutron electric dipole moment (nEDM). Using a 32-liter storage bottle, comparable in size to nEDM experiments, the authors measure and compare the UCN density at each source's beam port, providing a direct performance benchmark.
arXivarXiv · · October 26, 2016
0
Ultracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute
G. BanG. BisonK. BodekZ. ChowdhuriP. GeltenbortW.C. GriffithV. HélaineR. HenneckM. KasprzakY. KermaidicK. KirchS. Komposch  +23
This paper characterizes ultracold neutron (UCN) detection using 6Li-doped glass scintillators. A single 100–200 μm GS10 or GS20 scintillator achieves adequate UCN detection with acceptable neutron-gamma discrimination. A stack of 6Li-depleted and 6Li-enriched glass bonded by optical contact significantly improves this discrimination. The stack-based detector, named NANOSC, has been used in the nEDM experiment at PSI since 2010, handling rates up to 10^5 counts/s with efficiency similar to a 3He gas detector.
arXivarXiv · · June 23, 2016
0
An ultracold neutron storage bottle for UCN density measurements
G. BisonF. BurriM. DaumK. KirchJ. KrempelB. LaussM. MeierD. RiesP. Schmidt-WellenburgG. Zsigmond
The paper presents a 32-liter mobile storage bottle for ultracold neutrons (UCN), designed to measure the UCN density at beamports of the PSI UCN source. The bottle is robust and has a volume comparable to typical storage experiments, such as those searching for a neutron electric dipole moment. Its design, construction, and commissioning are described.
arXivarXiv · · June 6, 2016
0
A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron
J.M. PendleburyS. AfachN.J. AyresC.A. BakerG. BanG. BisonK. BodekM. BurghoffP. GeltenbortK. GreenW.C. GriffithM. van der Grinten  +38
This paper reanalyzes the experimental data that set the current world sensitivity limit on the neutron electric dipole moment (EDM). Incorporating improved understanding of gravity's effect on ultracold neutron depolarization, refined neutron spectrum calculations, and updated systematic error estimates, the analysis yields $d_\mathrm{n} = -0.21 \pm 1.82 \times 10^{-26} \, e\mathrm{cm}$. This implies a revised upper limit of $3.0 \times 10^{-26} \, e\mathrm{cm}$ (90% CL) or $3.6 \times 10^{-26} \, e\mathrm{cm}$ (95% CL).
arXivarXiv · · September 15, 2015
0
A highly stable atomic vector magnetometer based on free spin precession
S. AfachG. BanG. BisonK. BodekZ. ChowdhuriZ. D. GrujicL. HayenV. HelaineM. KasprzakK. KirchP. KnowlesH.-C. Koch  +22
This paper presents a highly stable atomic vector magnetometer that uses optically pumped Cs atoms to measure both the magnitude and direction of a 1 μT magnetic field. The central contribution is a design optimized for long-time stability, achieving a scalar resolution below 300 fT for integration times from 80 ms to 1000 s and a best scalar resolution under 80 fT at 1.6–6 s. Directional resolution better than 10 μrad was maintained for 10–2000 s.
arXivarXiv · · July 30, 2015
0
Gravitational Depolarization of Ultracold Neutrons: Comparison with Data
S. AfachN.J. AyresC.A. BakerG. BanG. BisonK. BodekM. FertlB. FrankeP. GeltenbortK. GreenW.C. GriffithM. van der Grinten  +38
This paper compares the expected effects of gravitationally enhanced depolarization of ultracold neutrons with measurements from a spin-precession chamber under various vertical magnetic-field gradients. The study finds excellent qualitative agreement, showing that this mechanism explains previously unexplained features in both spin depolarization rates and shifts in the measured neutron Larmor precession frequency.
arXivarXiv · · June 22, 2015
0
Observation of gravitationally induced vertical striation of polarized ultracold neutrons by spin-echo spectroscopy
S. AfachN.J. AyresG. BanG. BisonK. BodekZ. ChowdhuriM. DaumM. FertlB. FrankeW.C. GriffithZ.D. GrujićP.G. Harris  +36
We report a spin-echo method for ultracold neutrons confined in a precession chamber with a $1~\mu\text{T}$ magnetic field. The method reconstructs the energy spectrum of the ensemble by analyzing spin-echo resonance signals, leveraging the gravitationally induced vertical striation of neutrons with different energies. It also enables an improved determination of the vertical magnetic-field gradient to an accuracy of $1.1~\text{pT/cm}$. This technique is expected to be valuable for assessing systematic effects in precision experiments such as searches for the neutron electric dipole moment.
arXivarXiv · · June 1, 2015
0
Measurement of a false electric dipole moment signal from 199^{199}Hg atoms exposed to an inhomogeneous magnetic field
S. AfachC. A. BakerG. BanG. BisonK. BodekZ. ChowdhuriM. DaumM. FertlB. FrankeP. GeltenbortK. GreenM. G. D. van der Grinten  +37
The paper reports a Larmor frequency shift in $^{199}$Hg atoms that is linear in the applied electric field, mimicking an electric dipole moment (EDM) signal. The shift arises from the interplay of magnetic field gradients and the motional magnetic field, and is P- and T-conserving, unlike a true EDM. Using a neutron EDM spectrometer with a Hg co-magnetometer and Cs magnetometers, the authors measure the shift as a function of the applied gradient; results agree with theory.
arXivarXiv · · March 30, 2015
0
Frequent collaborators
K. Kirch (35)
B. Lauss (35)
G. Zsigmond (35)
P. Schmidt-Wellenburg (32)
K. Bodek (30)
J. Zejma (30)
T. Lefort (30)
S. Roccia (30)
D. Ries (29)
N. Severijns (29)
G. Pignol (28)
M. Daum (27)