MCP
GC

G. Che

7 papers in the library

Papers

7
Nuclear modification factor in Pb-Pb and p-Pb collisions using Boltzmann transport equation
L. QiaoG. CheJ. GuH. ZhengW.C. Zhang
Using the Boltzmann transport equation with relaxation time approximation, the study describes the nuclear modification factor ($R_{AA}$) of identified particles in Pb-Pb and p-Pb collisions. The initial particle distribution is modeled by the Tsallis distribution, and the local equilibrium distribution by the Boltzmann-Gibbs blast-wave distribution. A combined fit to $R_{AA}$ spectra up to $p_{\rm T}\approx 3$ GeV/c yields common non-extensive parameter $q_{pp}$, Tsallis temperature $T_{pp}$, and equilibrium temperature $T_{eq}$ for all particles, while the ratio of kinetic freeze-out time to relaxation time $t_{f}/\tau$ varies per particle. $q_{pp}$ and $T_{eq}$ decrease nonlinearly, $t_{f}/\tau$ increases with centrality, and $T_{pp}$ remains nearly centrality-independent. The dependence of these trends on collision energy and system size is examined.
arXivarXiv · · April 7, 2020
0
Optical Demonstration of THz, Dual-Polarization Sensitive Microwave Kinetic Inductance Detectors
B. DoberJ.A. AustermannJ.A. BeallD. BeckerG. CheH.M. ChoM. DevlinS.M. DuffN. GalitzkiJ. GaoC. GroppiG.C. Hilton  +8
We present the first optical demonstration of dual-polarization sensitive microwave kinetic inductance detectors (MKIDs) at 250 $\mu$m, a key step toward the BLAST-TNG balloon payload. Each spatial pixel comprises two orthogonal MKIDs made from a Ti/TiN multilayer film and coupled via a feedhorn and stepped half-wave plate. The devices are designed to be photon-noise-limited, meeting the requirements for mapping polarized dust emission in the 250 $\mu$m, 350 $\mu$m and 500 $\mu$m wavebands.
arXivarXiv · · March 9, 2016
0
A Titanium Nitride Absorber for Controlling Optical Crosstalk in Horn-Coupled Aluminum LEKID Arrays for Millimeter Wavelengths
H. McCarrickD. FlaniganG. JonesB. R. JohnsonP. A. R. AdeK. BradfordS. BryanR. CantorG. CheP. DayS. DoyleH. Leduc  +6
The paper presents a titanium nitride (TiN) mesh absorber that reduces optical crosstalk in horn-coupled aluminum LEKID arrays for millimeter wavelengths. Integrated on a fused silica anti-reflection coating, the absorber was tested on 20-element prototype arrays. Measurements show a 66% average reduction in crosstalk compared to arrays without the absorber, confirming its effectiveness for future kilo-pixel arrays.
arXivarXiv · · December 6, 2015
0
6
Low Noise Titanium Nitride KIDs for SuperSpec: A Millimeter-Wave On-Chip Spectrometer
S. Hailey-DunsheathE. ShirokoffP. S. BarryC. M. BradfordS. ChapmanG. CheJ. GlennM. HollisterA. KovácsH. G. LeDucP. MauskopfC. McKenney  +8
This paper presents SuperSpec, a millimeter-wave on-chip spectrometer for high-redshift galaxy survey spectroscopy. It employs a filter bank of half-wave superconducting resonators, each coupled to a titanium nitride (TiN) kinetic inductance detector (KID). A new prototype achieves the targeted resolving power of $R=100$ with improved sensitivity and optical efficiency. Using a new method that separates shot and wave noise with coherent and thermal sources, the authors measure an upper limit detector NEP of $1.4\times10^{-17}$ W Hz$^{-1/2}$, within 10% of the photon-noise limit for a ground-based $R=100$ spectrometer.
arXivarXiv · · November 14, 2015
0
25
Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic Inductance Detectors for Millimeter Wavelengths
H. McCarrickD. FlaniganG. JonesB. R. JohnsonP. AdeD. AraujoK. BradfordR. CantorG. CheP. DayS. DoyleH. Leduc  +7
The paper reports the design, commercial fabrication, and characterization of horn-coupled lumped-element kinetic inductance detectors (LEKIDs) for CMB studies. The 20-element arrays, made from aluminum on silicon and optimized for 150 GHz, achieved a 91% device yield and a noise-equivalent temperature of 26 ± 6 μK√s under a 4 K optical load, demonstrating a robust and scalable multiplexing scheme.
arXivarXiv · · July 29, 2014
0
58
A LEKID-based CMB instrument design for large-scale observations in Greenland
D. C. AraujoP. A. R. AdeJ. R. BondK. J. BradfordD. ChapmanG. CheP. K. DayJ. DidierS. DoyleH. K. EriksenD. FlaniganC. E. Groppi  +13
This paper presents a feasibility study for a ground-based millimeter-wave CMB polarimeter designed for deployment at Isi Station in Greenland. The instrument uses lumped-element kinetic inductance detectors (LEKIDs) and a 500 mm crossed-Dragone telescope cooled to < 4 K, with a rotating metal-mesh half-wave plate for polarization modulation and a modular detector array supporting bands centered at 150, 210, or 267 GHz. Mounted on a precision rotary air bearing, it enables continuous 360° scans, producing a hypotrochoid scan pattern that achieves 34% sky coverage and sensitivity to angular multipoles 5 < ℓ < 1000 at 150 GHz.
arXivarXiv · · July 10, 2014
0
10
Pressure Effect on Superconductivity of Iron-based Arsenic-oxide ReFeAsO0.85 (Re=Sm and Nd)
W. YiL. SunZ. RenX. DongH.ZhangX. DaiZ. FangG. CheJ. YangZ. LiX. ShenF. Zhou  +1
This paper reports the pressure dependence of the superconducting transition temperature $T_c$ in fluorine-free iron-based arsenic-oxide ReFeAsO$_{0.85}$ (Re = Sm and Nd). In-situ high-pressure measurements show that $T_c$ decreases monotonically with pressure in both compounds. The different pressure coefficients $dT_c/dP$ observed for SmFeAsO$_{0.85}$ and NdFeAsO$_{0.85}$ indicate that layer deformation significantly affects $T_c$. Theoretical calculations reveal that the electron density of states decreases with increasing pressure, consistent with the experimental trend.
arXivarXiv · · July 4, 2008
0
Frequent collaborators
P. Mauskopf (5)
J. Zmuidzinas (4)
H. McCarrick (3)
D. Flanigan (3)
G. Jones (3)
B. R. Johnson (3)
S. Doyle (3)
M. Limon (3)
T. Mroczkowski (3)
P. A. R. Ade (2)
K. Bradford (2)
R. Cantor (2)