MCP
GM

G Mana

13 papers in the library

Papers

13
Wavefront errors in a two-beam interferometer
G ManaE MassaC P Sasso
This paper examines how wavefront errors from optical aberrations in a two-beam interferometer affect the period of travelling fringes observed by integrating the interference pattern. Monte Carlo simulation shows that the fringe-period estimate remains unbiased when evaluated using the angular spectrum of the entering beam, but the wavefront errors increase the uncertainty of the estimate.
arXivarXiv · · July 16, 2020
0
Coupling of wavefront errors and pointing jitter in the LISA interferometer: misalignments of the interfering wavefronts
C P SassoG ManaS Mottini
The Laser Interferometer Space Antenna (LISA) aims to detect gravitational waves by heterodyning received and local laser wavefronts. This work analytically investigates how misalignments between these interfering wavefronts, caused by spacecraft and constellation jitter, couple with wavefront aberrations. The resulting coupling is shown to contribute to the noise in the heterodyne signal, providing an estimate of this noise source for LISA.
arXivarXiv · · March 8, 2019
0
The LISA interferometer: impact of stray light on the phase of the heterodyne signal
C P SassoG ManaS Mottini
The paper evaluates how stray light from the powerful transmitted beam affects the phase of the heterodyne signal in the LISA gravitational-wave detector. It finds that the dominant noise source is random phase variations of stray photons, and that a balanced detection scheme is more effective than frequency separation at mitigating this effect. To keep phase noise at the picometer level, the incoherent stray-light power must be below roughly 10 nW/W for a 1 % beam-splitter asymmetry.
arXivarXiv · · September 21, 2018
0
Density functional theory calculations of the stress of oxidised (110) silicon surfaces
C MelisS GiordanoL ColomboG Mana
This paper uses density functional theory to calculate the surface stress of oxidized (110) silicon surfaces. The computed value exceeds the 1 N/m tensile strength previously assumed in finite element analyses of intrinsic strain. This discrepancy suggests that the assumption of strain-free crystals in x-ray interferometry measurements of the silicon lattice parameter may be inaccurate, potentially affecting measurement precision.
arXivarXiv · · August 5, 2016
0
Improved measurement results for the Avogadro constant using a 28Si-enriched crystal
Y AzumaP Barat…G Mana
By reconditioning two 28Si-enriched spheres to remove metal contamination and improve sphericity, then measuring them with improved methods and apparatus, the X-ray crystal density method achieved the target relative standard uncertainty of 2.0×10⁻⁸ for the Avogadro constant. The result is $N_A = 6.02214076(12) \times 10^{23}$ mol⁻¹.
arXivarXiv · · December 16, 2015
0
Instrumental neutron activation analysis of an enriched 28Si single-crystal
G. DAgostinoL. BergamaschiL. GiordaniG. ManaM. Oddone
This paper extends a relative neutron activation analysis method to 59 elements and applies it to a monoisotopic $^{28}$Si single-crystal grown to test the enrichment for Avogadro-constant determination. The method quantifies contaminations by Ge, Ga, As, Tm, Lu, Ta, W, and Ir, and demonstrates that for several detectable elements a detection limit of 1 ng/g is already achievable, meeting the requirement for total impurity mass fraction below a few parts in $10^9$.
arXivarXiv · · September 19, 2013
0
The watt-balance operation: magnetic force and induced electric potential on a conductor in a magnetic field
C. P. SassoE. MassaG. Mana
This paper re-examines the magnetic force and induced electric potential in a watt balance from a microscopic perspective, focusing on corrective terms from a non-uniform conduction electron density caused by the magnetic field. The analysis shows that these corrections are irrelevant to the watt balance operation, confirming the validity of the macroscopic equations used for Planck constant measurement.
arXivarXiv · · December 21, 2012
0
Comment on "Compositional and Microchemical Evidence of Piezonuclear Fission Reactions in Rock Specimens Subjected to Compression Tests" [Strain 47 (Suppl. 2), 282 (2011)]
G. AmatoG. BertottiO. BottauscioG. CrottiF. FiorilloG. ManaM. L. RastelloP. TavellaF. Vinai
This comment argues that the chemical composition data in Carpinteri et al. (2011) cannot be from independent measurements as claimed. Consequently, those data provide no basis for concluding that piezonuclear reactions altered the stone composition during catastrophic failure.
arXivarXiv · · May 29, 2012
0
3
An accurate determination of the Avogadro constant by counting the atoms in a 28Si crystal
B. AndreasY. Azuma…G. Mana
The paper reports a determination of the Avogadro constant by counting the atoms in 1 kg single-crystal spheres highly enriched with the 28Si isotope. This approach, using isotope dilution mass spectroscopy to measure the molar mass with unprecedented accuracy, yields a value of 6.02214084(18) × 10^23 mol^-1, which is the most accurate input datum for redefining the kilogram in terms of a fundamental constant.
arXivarXiv · · October 12, 2010
0
Bayesian estimate of the zero-density frequency of a Cs fountain
D CalonicoF LeviL LoriniG Mana
The paper presents a Bayesian analysis that estimates the zero-density frequency of a Cs fountain clock by incorporating the known sign of the collisional coefficient as prior knowledge. Compared to the orthodox analysis, this method reduces the uncertainty of the frequency estimate by 28% when applied to data from the INRIM caesium fountain, demonstrating its value in primary frequency metrology.
arXivarXiv · · July 28, 2009
0
Bayesian inference of a negative quantity from positive measurement results
D CalonicoF LeviL LoriniG Mana
This paper applies Bayesian inference to assign a probability density to a quantity that is known to be negative, based on positive measurement results. The analysis yields a posterior density that is logically consistent with both positive and negative measurement outcomes, and is used to estimate the atom density shift in a caesium fountain clock. The advantages of this Bayesian approach for the realization of the time unit are discussed.
arXivarXiv · · February 17, 2009
0
Comparison of the INRIM and PTB lattice-spacing standards
E MassaG ManaU Kuetgens
This paper compares lattice-spacing standards from INRIM and PTB to support redefining the kilogram via the $^{28}\text{Si}$ atomic mass, which requires a relative lattice-parameter uncertainty of $3\times10^{-9}$. INRIM built a new apparatus with a centimetre measurement baseline. The comparison of crystals MO*4 (INRIM) and WASO4.2a (PTB) aims to verify measurement capabilities and assess experimental limits.
arXivarXiv · · February 3, 2009
0
X-ray and γγ-ray propagation in bent crystals with flat and cylindrical surfaces
A. ApolloniG. ManaC.PalmisanoG.Zosi
This paper solves the Takagi-Taupin equations for X-ray and gamma-ray propagation in crystals with constant strain gradient and flat or cylindrical surfaces, using the Riemann-Green method or a numerical method. The results are applied to a double-crystal Laue-Laue diffractometer with a flat collimator and a bent analyzer. The analysis confirms that, in both dispersive and non-dispersive setups, diffraction peak locations depend only on the diffracting plane spacing at the analyzer entrance surface, not on the bulk strain.
arXivarXiv · · February 25, 2008
0
7
Frequent collaborators
E Massa (3)
C P Sasso (3)
S Mottini (2)
U Kuetgens (2)
E. Massa (2)
D Calonico (2)
F Levi (2)
L Lorini (2)
C Melis (1)
S Giordano (1)
L Colombo (1)
Y Azuma (1)