MCP
HE

H. Ejiri

114 papers in the library · Same-name authors told apart using DBLP

Papers

30
Determination of the Muon Lifetime in 76^{76}Se with the MONUMENT experiment
G. R. AraujoD. BajpaiL. BaudisV. BelovE. BossioT. E. CocoliosH. EjiriM. FominaK. GusevI. H. HashimM. HeinesS. Kazartsev  +17
The MONUMENT collaboration measured the muon lifetime in $^{76}$Se, the daughter nucleus of $^{76}$Ge, to improve nuclear-physics benchmarks for neutrinoless double beta decay. Using high-purity germanium detectors and scintillator counters at the Paul Scherrer Institute, they obtained $(135.1 \pm 0.5)~\text{ns}$, which matches phenomenological calculations based on the quasiparticle random phase approximation with unquenched axial-vector coupling.
arXivarXiv · · October 27, 2025
0
Background stability and annual modulation test using PICOLON ultra-pure NaI(Tl) detector
PICOLON CollaborationK. KoteraD. ChernyakH. Ejiri. K. FushimiK. HataR. HazamaT. IidaH. IkedaK. ImagawaK. InoueH. Ito  +11
The PICOLON experiment uses ultra-pure NaI(Tl) crystals to independently test the dark matter signal claimed by DAMA/LIBRA. This paper reports that the Ingot#94 NaI(Tl) detector, produced with the same purification method as the previously reported Ingot#85, maintains long-term background stability over six months of measurement. Using this stable detector, the authors present the first annual modulation search performed by PICOLON, a key step toward verifying the DAMA/LIBRA result.
arXivarXiv · · September 26, 2025
0
1
Rare multi-nucleon decays with the full data sets of the Majorana Demonstrator
I.J. ArnquistF.T. Avignone III…H. Ejiri
Using the full 64.5 kg yr enriched exposure of the Majorana Demonstrator, this work searches for rare multi-nucleon decays in germanium isotopes, focusing on previously explored three-nucleon modes. The study sets new partial lifetime limits (90% confidence level) of $1.83\times10^{26}$ years for $^{76}\text{Ge}(ppp)\rightarrow^{73}\text{Cu}\ e^+\pi^+\pi^+$ and $2.1\times10^{25}$ years for the fully inclusive tri-proton decay of $^{76}\text{Ge}$, representing the central experimental contribution over prior results.
arXivarXiv · · December 20, 2024
0
Final Results of the MAJORANA DEMONSTRATOR's Search for Double-Beta Decay of 76^{76}Ge to Excited States of 76^{76}Se
I.J. ArnquistF.T. Avignone III…H. Ejiri
The MAJORANA DEMONSTRATOR searched for double-beta decay of $^{76}$Ge to excited states of $^{76}$Se, including both two-neutrino and neutrinoless modes. With 98.2 kg-y of isotopic exposure, it sets the strongest half-life limits for all six possible transitions. For the $2\nu\beta\beta$ decay to the $0^+_1$ state, it reaches a limit of $T_{1/2}>1.5\times10^{24}$ y (90% CL), entering the range predicted by modern many-body nuclear theory.
arXivarXiv · · October 5, 2024
0
An assay-based background projection for the MAJORANA DEMONSTRATOR using Monte Carlo Uncertainty Propagation
I.J. ArnquistF.T. Avignone III…H. Ejiri
This paper presents a Bayesian framework that calculates the background index for $0\nu\beta\beta$ experiments by treating specific activities, masses, and simulated efficiencies as distributions. Monte Carlo uncertainty propagation combines these distributions into a single background index distribution. Applied to the MAJORANA DEMONSTRATOR, which uses $^{76}$Ge-enriched detectors, the framework projects a mean background index of $[8.95 \pm 0.36] \times 10^{-4}$ cts/(keV kg yr) from $^{232}$Th and $^{238}$U in the experiment's components.
arXivarXiv · · August 13, 2024
0
Present status of PICOLON project
K. FushimiD. ChernyakH. EjiriK. HataR. HazamaT. IidaH. IkedaK. ImagawaK. InoueH. ItoT. KisimotoM. Koga  +15
The PICOLON project applies large-volume, high-purity inorganic crystal scintillators to simultaneously investigate cosmic dark matter and neutrino properties, two long-standing problems in cosmology and particle physics. The central contribution is the demonstration that such crystals are a promising detector technology for both dark matter searches and neutrino studies, as reported in the present status of the project.
arXivarXiv · · February 13, 2024
0
2
Majorana Demonstrator Data Release for AI/ML Applications
I.J. ArnquistF.T. Avignone III…H. Ejiri
This release provides a subset of calibration data from the Majorana Demonstrator experiment, formatted for AI/ML algorithm training and testing. Each event includes raw Germanium detector waveforms, pulse shape discrimination cuts, and calibrated final energies, stored in an HDF5 file with metadata. The accompanying document describes the dataset content, access method, and an associated NPML Machine Learning Challenge.
arXivarXiv · · August 21, 2023
0
1
Constraints on the decay of 180m^{180m}Ta
I.J. ArnquistF.T. Avignone III…H. Ejiri
Using the MAJORANA DEMONSTRATOR, an ultra-low-background array of high-purity germanium detectors, the authors searched for the decay of the long-lived nuclear isomer $^{180m}$Ta. Over 17 kg of tantalum metal—the largest amount ever used for such a search—was placed within the detector array. After one year of data taking, no decay was observed, yielding half-life limits up to $1.5 \times 10^{19}$ years, improving previous limits by one to two orders of magnitude and representing the most sensitive search for a single $\beta$ and electron capture decay achieved.
arXivarXiv · · June 3, 2023
0
Ordinary muon capture rates on 100^{100}Mo and nat^{\rm nat}Mo for astro-antineutrinos and double beta decays
I. H. HashimH. EjiriN. N. A. M. A. GhaniF. OthmanR. RazaliZ. W. NgT. ShimaD. TomonoD. ZinatulinaM. SchirchenkoS. KazartsevA. Sato  +3
The authors measured ordinary muon capture (OMC) rates on $^{100}$Mo and $^{\rm nat}$Mo to probe nuclear responses relevant to antineutrinos from double beta decays and astro-antineutrinos. By timing muon decays, they obtained $\Lambda(^{100}\mathrm{Mo}) = (7.07 \pm 0.32) \times 10^6 \,\mathrm{s}^{-1}$ and $\Lambda(^{\rm nat}\mathrm{Mo}) = (9.66 \pm 0.44) \times 10^6 \,\mathrm{s}^{-1}$. The $\sim27\%$ lower rate on $^{100}$Mo reflects the blocking effect of excess neutrons on proton-to-neutron transformation, and the results agree with Goulard–Primakoff and Primakoff empirical predictions.
arXivarXiv · · February 12, 2023
0
Modeling Backgrounds for the MAJORANA DEMONSTRATOR
C.R. HaufeI.J. Arnquist…H. Ejiri
The MAJORANA DEMONSTRATOR, a $0\nu\beta\beta$ experiment with enriched germanium detectors, achieved a background rate of 15.7 $\pm$ 1.4 cts/(FWHM t y) at the Q-value, five times higher than projected. Background model fits attribute this discrepancy to an excess of $^{232}$Th chain events, whose origin is not from a near-detector component. These fits support simulation studies and inform LEGEND design, with recent findings narrowing potential locations for the excess.
arXivarXiv · · September 21, 2022
0
Final Result of the MAJORANA DEMONSTRATOR's Search for Neutrinoless Double-ββ Decay in 76^{76}Ge
I.J. ArnquistF.T. Avignone III…H. Ejiri
MAJORANA DEMONSTRATOR set a lower limit on $^{76}$Ge neutrinoless double-$\beta$ decay half-life of $T_{1/2} > 8.3 \times 10^{25}$ yr (90% C.L.), using 64.5 kg yr of enriched active exposure from Ge detectors with 2.52 keV FWHM energy resolution at the $Q_{\beta\beta}$. This corresponds to $m_{\beta\beta}$ upper limits of $(113-269)$ meV depending on nuclear matrix elements.
arXivarXiv · · July 15, 2022
0
Exotic dark matter search with the Majorana Demonstrator
I.J. ArnquistF.T. Avignone III…H. Ejiri
The Majorana Demonstrator, using high-purity germanium detectors with ultra-low background, searches for exotic dark matter. From a 37.5-kg y exposure, it sets new limits on keV-scale sterile neutrino DM via transition magnetic moment, fermionic DM absorption, sub-GeV DM-nucleus 3→2 scattering, and bosonic DM (axionlike particles and dark photons), all in the 1–100 keV energy range.
arXivarXiv · · June 21, 2022
0
27
Search for solar axions via axion-photon coupling with the Majorana Demonstrator
I.J. ArnquistF.T. Avignone III…H. Ejiri
The Majorana Demonstrator experiment searched for solar axions via the axion-photon coupling using a 33 kg-yr exposure of $^{76}$Ge-enriched germanium detectors. A temporal-energy analysis yielded a new limit on the coupling $g_{a\gamma} < 1.45 \times 10^{-9}$ GeV$^{-1}$ (95% C.I.) for axion masses up to 100 eV/$c^2$, improving laboratory-based limits in the range from about 1 eV/$c^2$ to 100 eV/$c^2$.
arXivarXiv · · June 12, 2022
0
18
Experimental study of 13C(α,n)16O reactions in the Majorana Demonstrator calibration data
MAJORANA CollaborationI.J. Arnquist…H. Ejiri
The Majorana Demonstrator calibration data reveal the $^{13}\text{C}(\alpha,n)^{16}\text{O}$ reaction rate via 6129-keV $\gamma$-rays from excited $^{16}\text{O}$ states, induced by $\alpha$-particles in thorium-based calibration sources enclosed in carbon-rich materials. Comparisons between observed photon rates and TALYS-based predictions, facilitated by Geant4 simulations, show consistency despite large statistical uncertainties. This agreement supports background projections from ($\alpha,n$)-reactions for future double-beta decay searches.
arXivarXiv · · March 27, 2022
0
0
Search for charge nonconservation and Pauli exclusion principle violation with the Majorana Demonstrator
MAJORANA CollaborationI. J. Arnquist…H. Ejiri
Using a 37.5 kg-yr exposure from the Majorana Demonstrator's high-purity germanium detectors, we search for three beyond-standard-model processes. For charge nonconservation via $e \rightarrow \nu_e \overline{\nu_e} \nu_e$, we set a lower limit on the electron mean lifetime that improves the previous best bound by over an order of magnitude. We also probe two types of Pauli exclusion principle violation, constraining the probability that an electron occupies a symmetric quantum state.
arXivarXiv · · March 3, 2022
0
Search for Spontaneous Radiation from Wavefunction Collapse in the Majorana Demonstrator
I.J. ArnquistF.T. Avignone III…H. Ejiri
The Majorana Demonstrator, a 44 kg germanium detector array, searched for spontaneous x-ray radiation predicted by the continuous spontaneous localization (CSL) wavefunction collapse model. No evidence of such radiation was found in a 37.5 kg-y exposure collected between 2015 and 2019. Based on the null result, the experiment sets the most stringent upper limit to date on the CSL collapse rate $\lambda$, improving sensitivity by a factor of 40–100 over comparable searches.
arXivarXiv · · February 3, 2022
0
0
Nuclear matrix elements for neutrinoless double beta decays and spin-dipole giant resonances
H. EjiriL. JokiniemiJ. Suhonen
This paper shows that the experimental spin-dipole (SD) giant resonance energy and SD strength are closely related to the nuclear matrix elements (NMEs) for neutrinoless double beta decays (DBDs). The SD data are used to study the spin-isospin correlation and the quenching of the axial-vector coupling, thereby constraining theoretical model calculations of the DBD-NME.
arXivarXiv · · February 1, 2022
0
A Search for Electron Neutrino Transitions to Sterile States in the BEST Experiment
V.V. BarinovB.T. ClevelandS.N. DanshinH. EjiriS.R. ElliottD. FrekersV.N. GavrinV.V. GorbachevD.S. GorbunovW.C. HaxtonT.V. IbragimovaI. Kim  +18
The BEST experiment uses a two-zone liquid gallium target exposed to a $^{51}$Cr neutrino source to test the gallium anomaly. Measured $^{71}$Ge production rates in both zones show comparable deficits relative to predictions, with a $4\sigma$ deviation from unity. In the sterile neutrino oscillation framework, these deficits yield best-fit parameters $\Delta m^2=3.3^{+\infty}_{-2.3}$ eV$^2$ and $\sin^2 2\theta=0.42^{+0.15}_{-0.17}$, suggesting $\nu_e \to \nu_s$ oscillations with a surprisingly large mixing angle.
arXivarXiv · · January 19, 2022
0
PICOLON dark matter search project
K. FushimiD. ChernyakH. EjiriK. HataR. HazamaT. IidaH. IkedaK. ImagawaK. InoueH. IshiuraH. ItoT. Kishimoto  +12
The PICOLON project searches for dark matter using ultra-pure NaI(Tl) scintillators. Its key contribution is a hybrid purification method that reduces the internal $^{210}$Pb activity to below 5.7 $\mu$Bq/kg, a critical background for annual modulation detection. The paper reports a low-background test at Kamioka Underground Laboratory and discusses the sensitivity to annual modulating signals expected from dark matter particles.
arXivarXiv · · December 19, 2021
0
14
The MAJORANA DEMONSTRATOR Readout Electronics System
N. AbgrallM. Amman…H. Ejiri
The MAJORANA DEMONSTRATOR readout electronics system is described, covering front-end and back-end electronics, cabling, digitizers, and power supplies with a grounding scheme. It was designed for low electronic noise and minimal radioactive background, using low-mass components and low-radioactivity materials near the high-purity germanium detectors. The spectroscopic performance achieved with this system is also demonstrated.
arXivarXiv · · November 17, 2021
0
20
Signatures of muonic activation in the Majorana Demonstrator
I.J. ArnquistF.T. Avignone III…H. Ejiri
The Majorana Demonstrator searches for neutrinoless double-beta decay, requiring extremely low backgrounds. This work uses the Demonstrator's data to identify decay signatures of metastable germanium isotopes produced by muon interactions within the detectors themselves. By correlating time-delayed signals, the measured rate of these decays is found to agree well with simulations. The validated simulation framework is then extended to predict the cosmogenic background for the future tonne-scale LEGEND experiment, which aims for a sensitivity of $10^{28}$ years half-life.
arXivarXiv · · October 27, 2021
0
12
Results from the Baksan Experiment on Sterile Transitions (BEST)
V.V. BarinovB.T. ClevelandS.N. DanshinH. EjiriS.R. ElliottD. FrekersV.N. GavrinV.V. GorbachevD.S. GorbunovW.C. HaxtonT.V. IbragimovaI. Kim  +18
The Baksan Experiment on Sterile Transitions (BEST) placed a 3.414-MCi $^{51}\text{Cr}$ neutrino source at the center of two nested gallium volumes and measured $^{71}\text{Ge}$ production via the charged-current reaction at two average distances. The inner and outer rates were $54.9^{+2.5}_{-2.4}\pm1.4$ and $55.6^{+2.7}_{-2.6}\pm1.4$ atoms of $^{71}\text{Ge}/\text{d}$, respectively, corresponding to $R_{\text{in}}=0.79\pm0.05$ and $R_{\text{out}}=0.77\pm0.05$ of the expected rate. The outer-to-inner ratio $0.97\pm0.07$ is consistent with unity, but both rates are 20–24% lower than expected, reaffirming the gallium anomaly and consistent with $\nu_e\to\nu_s$ oscillations at $\Delta m^2>0.5$ eV$^2$ and $\sin^2 2\theta\approx0.4$.
arXivarXiv · · September 23, 2021
0
284
Dark matter search with high purity NaI(Tl) scintillator
K. FushimiY. KanemitsuK. KoteraD. ChernyakH. EjiriK. HataR. HazamaT. IidaH. IkedaK. ImagawaK. InoueH. Ishiura  +12
This paper reports the development of a highly radiopure NaI(Tl) crystal for dark matter search. By optimizing purification methods, the authors achieved residual $^{\mathrm{nat}}$K below 20 ppb and $^{210}$Pb below 5.7 $\mu$Bq/kg, addressing the need for extremely low background radiation. The design and performance of a prototype detector module for a planned large-volume detector system are presented.
arXivarXiv · · June 29, 2021
0
1
The Majorana Demonstrator's Search for Double-Beta Decay of 76^{76}Ge to Excited States of 76^{76}Se
I.J. ArnquistF.T. Avignone III…H. Ejiri
The Majorana Demonstrator, a low-background array of high-purity germanium detectors (≈2/3 enriched to 88% in $^{76}$Ge), searches for double-beta decay of $^{76}$Ge to excited states of $^{76}$Se. The signature involves a $\beta\beta$ decay followed by prompt $\gamma$-rays, producing multi-detector coincidences. With 41.9 kg-y of isotopic exposure, the experiment set world-leading 90% CL lower half-life limits for each excited-state decay, ranging from $(0.75-4.0)\times10^{24}$ y, including $7.5\times10^{23}$ y for the $2\nu$ transition to the first $0^+$ excited state.
arXivarXiv · · August 13, 2020
0
3
Results of the MAJORANA DEMONSTRATOR's Search for Double-Beta Decay of 76^{76}Ge to Excited States of 76^{76}Se
I.S. GuinnI.J. Arnquist…H. Ejiri
The MAJORANA DEMONSTRATOR searched for double-beta decay of $^{76}$Ge to excited states of $^{76}$Se using a modular array of high-purity germanium detectors. The distinctive multi-site event signature of the $\beta\beta$ decay with prompt $\gamma$-rays, combined with the detector's granularity, enabled strong background discrimination. With 21.3 kg-y of isotopic exposure, the experiment set world-leading 90% CL lower half-life limits of $(0.56-2.1)\times 10^{24}$ y for each excited-state decay, including $0.68\times 10^{24}$ y for the $2\nu$ transition to the first $0^+$ state.
arXivarXiv · · December 12, 2019
0
6
A Low Energy Rare Event Search with the Majorana Demonstrator
MAJORANA CollaborationC. Wiseman…H. Ejiri
Using the MAJORANA DEMONSTRATOR, a low-energy rare-event search is conducted with a novel training set of small-angle Compton scatter events to determine pulse-shape analysis cut efficiency. Based on an 11.17 kg-y dataset and a 5 keV threshold, updated exclusion limits are set for bosonic dark matter and solar axions, demonstrating sensitivity to sub-keV interactions.
arXivarXiv · · December 12, 2019
0
10
Nuclear Isotope Production by Ordinary Muon Capture Reaction
I.H. HashimH. EjiriF. OthmanF. IbrahimF. SoberiN.N.A.M.A. GhaniT. ShimaA. SatoK. Ninomiya
This paper presents muon-capture isotope production (MuCIP), which uses ordinary muon capture (OMC) reactions to produce nuclear isotopes. High capture probability and intense muon beams enable rates of 10⁹–10¹⁰ isotopes per second. The method is demonstrated on natural molybdenum (NatMo) at the RCNP MuSIC facility, producing isotopes such as ⁹⁹Mo and metastable ⁹⁹ᵐTc important for medical applications. A pre-equilibrium and equilibrium proton–neutron emission model evaluates the yields. MuCIP complements photon- and neutron-capture methods.
arXivarXiv · · August 22, 2019
0
A Search for Neutrinoless Double-Beta Decay in 76^{76}Ge with 26 kg-yr of Exposure from the MAJORANA DEMONSTRATOR
S.I. AlvisI.J. Arnquist…H. Ejiri
The MAJORANA DEMONSTRATOR, an array of high-purity Ge detectors (29.7 kg enriched in $^{76}$Ge) at the Sanford Underground Research Facility, searches for neutrinoless double-beta decay. With 26.0 kg-yr of enriched exposure and an energy resolution of 2.53 keV FWHM at $Q_{\beta\beta}$, the collaboration observes one event in the region of interest against 0.65 expected background events, setting a lower limit on the $^{76}$Ge half-life of $2.7\times10^{25}$ yr (90% CL) and a median sensitivity of $4.8\times10^{25}$ yr (90% CL). This corresponds to a 90% CL upper limit on the effective Majorana neutrino mass of 200–433 meV, depending on nuclear matrix elements.
arXivarXiv · · February 6, 2019
0
Multi-site event discrimination for the MAJORANA DEMONSTRATOR
S.I. AlvisI.J. Arnquist…H. Ejiri
For the MAJORANA DEMONSTRATOR's search for neutrinoless double-beta decay in $^{76}$Ge, a pulse-shape analysis cut named AvsE is developed to discriminate multi-site background events from single-site signal events. The cut uses the relationship between maximum current and energy, retaining $(90 \pm 3.5)\%$ of single-site events while rejecting multi-site waveforms. Its efficiency uncertainty includes variation across detectors, energy, and time, and the position-distribution difference between calibration and $0\nu\beta\beta$ events, determined via simulations.
arXivarXiv · · January 16, 2019
0
Recent results from the MAJORANA DEMONSTRATOR
J. MyslikS. I. Alvis…H. Ejiri
The MAJORANA DEMONSTRATOR searches for neutrinoless double-beta decay in $^{76}$Ge using two modules of germanium detectors totaling 44.1 kg at the Sanford Underground Research Facility. Its ultra-low background and record energy resolution enable a sensitive search for this decay, testing lepton number conservation. The paper reports the latest results from this search, discusses design elements enabling such sensitivity, and outlines plans for a future tonne-scale $^{76}$Ge experiment.
arXivarXiv · · December 19, 2018
0
Frequent collaborators
R. Henning (64)
K. Rielage (63)
M. Busch (62)
Yu. Efremenko (60)
J. Gruszko (56)
S. Vasilyev (54)
W. Xu (54)
C. Cuesta (53)
C. Wiseman (53)
S.R. Elliott (52)
Y-D. Chan (52)
D. Tedeschi (50)