A Cryogenic Penning Trap Based on Permanent Magnets
F. VölksenK. K. Anjum…J. A. Devlin
This paper demonstrates a Penning trap using NdFeB permanent magnets, operating at 4 K with a 280 mT field. Single protons, H₂⁺ ions, and electrons were loaded and confined, with non-destructive detection via superconducting circuits. Axial-frequency shot-to-shot stability reached 47 ppb, comparable to conventional precision traps, while the proton modified-cyclotron frequency showed 0.14 ppm scatter, limited by millikelvin temperature fluctuations. The design offers a compact, scalable approach for precision measurements and portable antiproton systems.

arXiv ·
· September 22, 2026