Low-Energy Radon Backgrounds from Electrode Grids in Dual-Phase Xenon TPCs
D. S. AkeribA. K. Al Musalhi…J. Balajthy
The dual-phase xenon TPC, sensitive to few-electron signals from low-mass dark matter, suffers from electron backgrounds. This paper presents a first-principle model attributing much of this background to $^{222}$Rn decay chain isotopes plated on the high-voltage electrode grids spanning the TPC cross-section. The model's predictions are consistent with LZ and LUX data. Mitigation strategies and application to ionization-only dark matter searches are discussed.
arXivarXiv · · February 24, 2026
0
2
A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
M. SzydagisJ. BalajthyG.A. BlockJ.P. BrodskyE. BrownJ.E. CutterS.J. FarrellJ. HuangA.C. KamahaE.S. KozlovaC.S. LiebenthalD.N. McKinsey  +14
This review presents the Noble Element Simulation Technique (NEST) for liquid xenon detectors, a toolkit that uses experimental data and empirical formulae to model scintillation and ionization yields as functions of particle type, energy, and electric field. NEST outputs are compared against other models and validated with data from XENON, LUX, LZ, and other experiments, making it a central reference for simulating detector responses in rare-event searches.
arXivarXiv · · November 19, 2022
0
First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
J. AalbersD.S. Akerib…J. Balajthy
The LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time projection chamber at the Sanford Underground Research Facility, reports its first search for weakly interacting massive particles (WIMPs). Based on 60 live days of exposure with a 5.5 t fiducial mass, a profile-likelihood ratio analysis found the data consistent with a background-only hypothesis, setting the most stringent limit on spin-independent WIMP-nucleon cross sections: for a 36 GeV/c$^2$ WIMP, cross sections above $9.2 \times 10^{-48}$ cm$^2$ are excluded at 90% confidence. New limits are also set for spin-dependent WIMP-neutron and WIMP-proton interactions for masses above 9 GeV/c$^2$.
arXivarXiv · · July 8, 2022
0
1k+
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
J. AalbersK. Abe…J. Balajthy
This review article argues that a next-generation dual-phase xenon time-projection chamber will serve as a multi-purpose observatory, advancing dark matter and neutrino physics. It is the leading technology for probing Weakly Interacting Massive Particles (WIMPs) and other dark matter candidates, while also enabling studies of neutrinoless double-beta decay and astrophysical neutrinos. The paper presents the science cases for such a detector, highlighting its potential contributions to particle physics, nuclear physics, astrophysics, solar physics, and cosmology.
arXivarXiv · · March 4, 2022
1
255
Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning
LUX CollaborationD.S. AkeribS. AlsumH.M. AraújoX. BaiJ. BalajthyJ. BangA. BaxterE.P. BernardA. BernsteinT.P. BiesiadzinskiE.M. Boulton  +88
This work combines machine learning with the profile likelihood fit procedure on LUX dark matter data, achieving a 30-fold reduction in computation time without loss of performance. The method flexibly captures non-linear correlations between variables, performing equally well with or without position corrections on pulse areas. It also efficiently incorporates additional variables, such as a light signal pulse shape, enabling future experiments to use more information and reduce computational resources.
arXivarXiv · · January 15, 2022
0
16
Cosmogenic production of 37^{37}Ar in the context of the LUX-ZEPLIN experiment
J. AalbersD.S. Akerib…J. Balajthy
The paper estimates that cosmogenic spallation during above-ground xenon storage produces $^{37}$Ar at 0.024 atoms/kg/day at sea level. For a 10-tonne payload purified in 1-tonne monthly batches, the resulting $^{37}$Ar activity in the LUX-ZEPLIN experiment is 0.058–0.090 $\mu$Bq/kg, serving as a noticeable background in early data with a 35-day half-life. This production mechanism should be considered in future liquid xenon experiments.
arXivarXiv · · January 8, 2022
0
Projected sensitivities of the LUX-ZEPLIN (LZ) experiment to new physics via low-energy electron recoils
LZ CollaborationD.S. Akerib…J. Balajthy
LUX-ZEPLIN (LZ), a xenon-based dark matter detector, will achieve world-leading sensitivity to several new physics signals via low-energy electron recoils. For a 5.6 tonne-year exposure and backgrounds below 100 keV, LZ will constrain an effective neutrino magnetic moment and millicharge from solar pp neutrinos, solar axions, axion-like-particle dark matter, hidden photons, mirror dark matter, and leptophilic dark matter. The analysis uses a consistent signal, background, and profile-likelihood framework.
arXivarXiv · · February 23, 2021
0
Constraints on Effective Field Theory Couplings Using 311.2 days of LUX Data
D.S. AkeribS. AlsumH.M. AraújoX. BaiJ. BalajthyJ. BangA. BaxterE.P. BernardA. BernsteinT.P. BiesiadzinskiE.M. BoultonB. Boxer  +85
Using 311.2 days of LUX data with a 3.14×10⁴ kg·day exposure, this work extends the nuclear recoil search window to ~180 keV$_{nr}$ and employs a binned Profile Likelihood framework to set 90% C.L. exclusion limits on non-relativistic Effective Field Theory (EFT) couplings for WIMP-nucleon interactions. These limits are the most stringent to date for a significant fraction of EFT operators, and the analysis also produces world-leading constraints on inelastic EFT WIMP-nucleon recoils.
arXivarXiv · · February 13, 2021
0
32
Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals
D.S. AkeribA.K. Al MusalhiS.K. AlsumC.S. AmarasingheA. AmesT.J. AndersonN. AngelidesH.M. AraújoJ.E. ArmstrongM. ArthursX. BaiJ. Balajthy  +175
This simulation study investigates two techniques for lowering the energy threshold of the LUX-ZEPLIN (LZ) two-phase xenon detector, enhancing sensitivity to low-mass dark matter and astrophysical neutrinos. The first technique exploits the double photoelectron emission effect, where a single vacuum ultraviolet photon has a ~20% probability of ejecting two photoelectrons from a photomultiplier tube photocathode. The second technique removes the S1 signal requirement, using only the more efficiently detected ionization signal. When incorporating double photoelectron signals, the dark matter-nucleon scattering cross-section sensitivity improves by a factor of ~4 at 2.5 GeV/c$^2$ and the solar $^8$B neutrino detection rate increases by a factor of ~1.6. Dropping the S1 requirement may yield two orders of magnitude improvement in both cases. Applying these techniques with the Migdal effect could lower the dark matter particle mass threshold to 80 MeV/c$^2$.
arXivarXiv · · January 21, 2021
0
14
Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
LUX CollaborationD. S. AkeribS. AlsumH. M. AraújoX. BaiJ. BalajthyJ. BangA. BaxterE. P. BernardA. BernsteinT. P. BiesiadzinskiE.M. Boulton  +86
This paper presents a machine learning technique that uses ionization pulse shape to identify and reject low-energy electron backgrounds from wire grid electrodes in the LUX xenon time projection chamber, thereby improving the sensitivity of low-mass dark matter searches. The technique improves Poisson limits on low-mass dark matter interactions by a factor of 2-7 depending on the size of ionization signals. Applied to an effective 5 tonne-day exposure from LUX's 2013 science operation, the method places strong limits on dark matter particles with masses $m_{\chi}\in0.15$-$10$ GeV. The technique is expected to benefit future experiments like LZ and XENONnT.
arXivarXiv · · November 19, 2020
0
43
An Effective Field Theory Analysis of the First LUX Dark Matter Search
D.S. AkeribS. AlsumH.M. AraújoX. BaiJ. BalajthyA. BaxterE.P. BernardA. BernsteinT.P. BiesiadzinskiE.M. BoultonB. BoxerP. Brás  +85
This paper reports the first search for all 14 effective field theory (EFT) operators describing WIMP-nucleon interactions using the initial science run of the LUX dark matter experiment. The analysis, based on a 1.4×10⁴ kg·day exposure, places limits on each coupling as a function of WIMP mass. This extends beyond the conventional spin-independent and spin-dependent paradigm to include novel responses such as angular-momentum-dependent and spin-orbit couplings.
arXivarXiv · · March 24, 2020
0
Projected sensitivity of the LUX-ZEPLIN experiment to the 0νββ0νββ decay of 136^{136}Xe
D. S. AkeribC. W. AkerlofA. AlqahtaniS. K. AlsumT. J. AndersonN. AngelidesH. M. AraújoJ. E. ArmstrongM. ArthursX. BaiJ. BalajthyS. Balashov  +180
The LUX-ZEPLIN (LZ) experiment, primarily designed for dark matter detection, can simultaneously search for neutrinoless double beta decay ($0\nu\beta\beta$) of $^{136}$Xe using its >600 kg of natural $^{136}$Xe. After 1000 live-days, the median exclusion sensitivity to the $^{136}$Xe half-life is projected to be $1.06\times10^{26}$ years (90% CL), comparable to current limits. A future dedicated run with 90% enriched $^{136}$Xe could reach $1.06\times10^{27}$ years.
arXivarXiv · · December 9, 2019
0
0
Search for two neutrino double electron capture of 124^{124}Xe and 126^{126}Xe in the full exposure of the LUX detector
LUX CollaborationD. S. AkeribS. AlsumH. M. AraújoX. BaiJ. BalajthyA. BaxterE. P. BernardA. BernsteinT. P. BiesiadzinskiE. M. BoultonB. Boxer  +87
Using the full 27769.5 kg-day exposure of the LUX detector, the search for two-neutrino double electron capture in $^{124}$Xe and $^{126}$Xe found no signal, yielding 90% C.L. lower half-life limits of $2.0\times10^{21}$ years and $1.9\times10^{21}$ years, respectively.
arXivarXiv · · December 5, 2019
0
12
The LUX-ZEPLIN (LZ) Experiment
LZ CollaborationD.S. Akerib…J. Balajthy
The LUX-ZEPLIN (LZ) experiment is a direct dark matter search designed to detect cosmic WIMP nuclear recoils using a large liquid xenon time projection chamber. Background rejection is enhanced by a Xe skin veto and a gadolinium-loaded liquid scintillator outer detector for efficient neutron tagging. The experiment is located at the 4850′ level of the Sanford Underground Research Facility.
arXivarXiv · · October 21, 2019
0
406
Improved Modeling of ββ Electronic Recoils in Liquid Xenon Using LUX Calibration Data
LUX CollaborationD.S. AkeribS. AlsumH.M. AraújoX. BaiJ. BalajthyA. BaxterE.P. BernardA. BernsteinT.P. BiesiadzinskiE.M. BoultonB. Boxer  +87
This paper details the creation and tuning of a model for electronic recoils in liquid xenon using LUX calibration data. The model, based on the NEST v2.0 framework, is refined using beta decay data from ${}^3$H and ${}^{14}$C and external datasets to extrapolate beyond LUX conditions. The resulting model and detector parameters will be used in the LUX Legacy Analysis Monte Carlo Application (LLAMA) for accurate background reproduction in dark matter searches.
arXivarXiv · · October 9, 2019
0
15
First direct detection constraint on mirror dark matter kinetic mixing using LUX 2013 data
LUX CollaborationD. S. AkeribS. AlsumH. M. AraújoX. BaiJ. BalajthyA. BaxterE. P. BernardA. BernsteinT. P. BiesiadzinskiE. M. BoultonB. Boxer  +88
Using 95 live-days × 118 kg from LUX 2013, this search finds no mirror dark matter electron recoil signal after accounting for Earth shielding, annual/diurnal modulation, and atomic shell effects. It places the first direct detection upper limit on the kinetic mixing parameter for local mirror electron temperatures 0.1–0.6 keV, improving on previous orthopositronium bounds. Mirror electron temperatures above 0.3 keV are excluded at 90% confidence, and the mixing is constrained below this temperature.
arXivarXiv · · August 9, 2019
0
29
Extending light WIMP searches to single scintillation photons in LUX
D. S. AkeribS. AlsumH. M. AraújoX. BaiA. J. BaileyJ. BalajthyA. BaxterP. BeltrameE. P. BernardA. BernsteinT. P. BiesiadzinskiE. M. Boulton  +113
We present a new analysis technique for liquid xenon TPCs that lowers the energy threshold by accepting events with a single detected photon in the prompt scintillation signal, exploiting the double photoelectron emission effect in certain photomultipliers. Applied to LUX 2013 electron recoil calibration data, this yields new constraints on the spin-independent WIMP-nucleon cross section down to a WIMP mass of 2.5 GeV/c$^2$, extending sensitivity to light dark matter and promising improvements for next-generation experiments.
arXivarXiv · · July 14, 2019
0
50
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
D. S. AkeribS. AlsumH. M. AraújoX. BaiJ. BalajthyA. BaxterP. BeltrameE. P. BernardA. BernsteinT. P. BiesiadzinskiE. M. BoultonB. Boxer  +89
Using high-statistics $^{3}$H and $^{14}$C calibration data from the LUX detector, this work provides improved measurements of the $\beta$-decay response in liquid xenon. The mean light-to-charge ratio is reported for 13 electric field values (43–491 V/cm) and energies from 1.5 to 145 keV, serving as a reference for dark matter and neutrino experiments.
arXivarXiv · · March 29, 2019
0
Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
D.S. AkeribS. AlsumH.M. AraújoX. BaiJ. BalajthyP. BeltrameE.P. BernardA. BernsteinT.P. BiesiadzinskiE.M. BoultonB. BoxerP. Brás  +86
Using the Bremsstrahlung and Migdal effects, which produce detectable electron recoils from sub-GeV dark matter (DM) scattering, the LUX experiment analyzed 1.4×10^4 kg·day of 2013 data to constrain spin-independent DM–nucleon scattering for DM masses of 0.4–5 GeV/c^2 across four mediator classes. This method extends liquid xenon-based DM searches to lower masses than previously achieved.
arXivarXiv · · November 27, 2018
0
241
Search for annual and diurnal rate modulations in the LUX experiment
D.S. AkeribS. AlsumH.M. AraújoX. BaiJ. BalajthyP. BeltrameE.P. BernardA. BernsteinT.P. BiesiadzinskiE.M. BoultonB. BoxerP. Brás  +84
The LUX experiment searches for annual and diurnal modulations of dark matter interaction rates, using 20 months of data. Focusing on low-energy electron recoil events, it achieves a stable rate of 2.3±0.2 cpd/keVee/tonne. No significant annual modulation is observed up to 26 keVee, and between 2–6 keVee the result shows 9.2σ tension with DAMA/LIBRA. No diurnal modulation above 0.2 cpd/keVee/tonne amplitude is found in that window.
arXivarXiv · · July 18, 2018
0
66
LUX Trigger Efficiency
D.S. AkeribS. AlsumH.M. AraújoX. BaiJ. BalajthyP. BeltrameE.P. BernardA. BernsteinT.P. BiesiadzinskiE.M. BoultonB. BoxerP. Brás  +85
The LUX dark-matter experiment reports the trigger efficiency of its dual-phase xenon detector, defined as the probability that an event of interest is selected for offline analysis. From raw calibration data for electron recoils (ER) and nuclear recoils (NR), the efficiency exceeds 98% at a pulse area of 90 detected photons, well below the WIMP analysis threshold. It also exceeds 98% at recoil energies ≥0.2 keV (ER) and ≥1.3 keV (NR), and varies between 99% and 100% over the fiducial volume.
arXivarXiv · · February 21, 2018
0
6
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
D.S. AkeribC.W. AkerlofS.K. AlsumH.M. AraújoM. ArthursX. BaiA.J. BaileyJ. BalajthyS. BalashovD. BauerJ. BelleP. Beltrame  +166
The LUX-ZEPLIN (LZ) experiment, a next-generation dark matter direct-detection instrument using a 7-tonne two-phase xenon detector, projects its sensitivity to Weakly Interacting Massive Particles (WIMPs) based on updated background estimates and simulations. For a 1000-day run with a 5.6-tonne fiducial mass, LZ is expected to exclude spin-independent WIMP-nucleon cross sections above $1.4 \times 10^{-48}$ cm$^2$ at 90% confidence for a 40 GeV/$c^2$ WIMP, and to achieve a $5\sigma$ discovery potential below recent experimental limits. Spin-dependent sensitivities for 40 GeV/$c^2$ WIMPs are projected at $2.3 \times 10^{-43}$ cm$^2$ (neutron) and $7.1 \times 10^{-42}$ cm$^2$ (proton).
arXivarXiv · · February 16, 2018
0
Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
D. S. AkeribS. AlsumH. M. AraújoX. BaiA. J. BaileyJ. BalajthyP. BeltrameE. P. BernardA. BernsteinT. P. BiesiadzinskiE. M. BoultonP. Brás  +86
For the LUX dark matter experiment, the 2013 analysis of $1.4\times10^4\,\mathrm{kg\,days}$ of target exposure is described in detail. The central contribution is a set of stringent upper limits on the nuclear scattering cross section for dark matter, derived through calibration, event reconstruction, and statistical tests. Innovations include in situ measurement of photomultiplier response to xenon scintillation, verification of fiducial mass with an internal low-energy source, and empirical models for low-energy signal yield from large-sample calibrations.
arXivarXiv · · December 15, 2017
0
Position Reconstruction in LUX
LUX CollaborationD. S. AkeribS. AlsumH. M. AraújoX. BaiA. J. BaileyJ. BalajthyP. BeltrameE. P. BernardA. BernsteinT. P. BiesiadzinskiE. M. Boulton  +82
The LUX experiment's $(x, y)$ position reconstruction method uses an iterative statistical test to derive PMT light response functions directly from calibration data, incorporating a two-dimensional functional form for wall-reflected photons and a photon counting technique for small pulses. The method achieves a horizontal position uncertainty of $\sigma = 0.82$ cm for 200 electroluminescence photons (electron recoil energy $\sim$0.25 keV) and $\sigma = 0.17$ cm for 4,000 photons ($\sim$10 keV), with a single electron event uncertainty of 2.13 cm.
arXivarXiv · · October 7, 2017
0
60
Ultra-Low Energy Calibration of LUX Detector using 127^{127}Xe Electron Capture
LUX CollaborationD. S. AkeribS. AlsumH. M. AraújoX. BaiA. J. BaileyJ. BalajthyP. BeltrameE. P. BernardA. BernsteinT. P. BiesiadzinskiE. M. Boulton  +82
This paper reports an absolute calibration of the ionization yield ($Q_y$) and its fluctuations for electronic recoils in liquid xenon at discrete energies from 186 eV to 33.2 keV, using $^{127}$Xe electron capture decay data from the first 95-day run of the LUX detector. By identifying K-, L-, M-, and N-shell cascade events, the authors verify the observed event ratios against calculations. The N-shell analysis includes single-electron events and constitutes the lowest-energy electronic recoil in situ measurements in liquid xenon to date.
arXivarXiv · · September 4, 2017
0
3D Modeling of Electric Fields in the LUX Detector
LUX CollaborationD. S. AkeribS. AlsumH. M. AraújoX. BaiA. J. BaileyJ. BalajthyP. BeltrameE. P. BernardA. BernsteinT. P. BiesiadzinskiE. M. Boulton  +82
This paper presents a three-dimensional electric field model developed for the LUX dark matter detector. A time-varying negative charge on the PTFE panels caused radial forces on drifting electrons. The model, built monthly in COMSOL Multiphysics and fitted to calibration data, maps field variations over time, depth, and azimuth. The average PTFE charge density increased from -3.6 to -5.5 $\mu$C/m$^2$ during the exposure, while the mean field of ~200 V/cm remained constant. This work enables accurate modeling of field effects on event reconstruction.
arXivarXiv · · August 31, 2017
0
48
83m^{83\textrm{m}}Kr calibration of the 2013 LUX dark matter search
LUX CollaborationD. S. AkeribS. AlsumH. M. AraújoX. BaiA. J. BaileyJ. BalajthyP. BeltrameE. P. BernardA. BernsteinT. P. BiesiadzinskiE. M. Boulton  +82
The LUX dark matter experiment introduced a $^{83\mathrm{m}}$Kr calibration source for the first time. This paper reports the source preparation and injection methods, and shows how the source was used to measure temporal and spatial variations in scintillation and charge signal amplitudes during the 2013 exposure. The calibration also enabled several independent ways to characterize the electric field inside the time projection chamber, which is essential for understanding detector response.
arXivarXiv · · August 8, 2017
0
Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
LUX CollaborationD. S. AkeribS. AlsumH. M. AraújoX. BaiA. J. BaileyJ. BalajthyP. BeltrameE. P. BernardA. BernsteinT. P. BiesiadzinskiE. M. Boulton  +88
Using the complete 129.5 kg-year exposure from the LUX experiment, a profile likelihood ratio analysis sets 90% CL upper limits on spin-dependent WIMP-nucleon elastic cross sections. For a 35 GeV/$c^{2}$ WIMP, the WIMP-neutron limit is $\sigma_n = 1.6 \times 10^{-41}$ cm$^{2}$ and the WIMP-proton limit is $\sigma_p = 5 \times 10^{-40}$ cm$^{2}$, representing a nearly sixfold improvement over previous LUX spin-dependent results, with the neutron limit being the most sensitive constraint to date.
arXivarXiv · · May 9, 2017
0
368
First Searches for Axions and Axion-Like Particles with the LUX Experiment
D.S. AkeribS. AlsumC. AquinoH.M. AraújoX. BaiA.J. BaileyJ. BalajthyP. BeltrameE.P. BernardA. BernsteinT.P. BiesiadzinskiE.M. Boulton  +89
The LUX experiment set the first direct constraints on axions and axion-like particles using 95 live-days of data from 118 kg of liquid xenon. Assuming an axio-electric interaction, a profile likelihood ratio test excludes solar axion–electron coupling $g_{Ae} > 3.5 \times 10^{-12}$ at 90% CL, corresponding to an axion mass below 0.12 eV/c$^2$ under the DFSZ model. For galactic axion-like particles with masses 1–16 keV/c$^2$, $g_{Ae} > 4.2 \times 10^{-13}$ is excluded. These are the most stringent limits for these interactions.
arXivarXiv · · April 7, 2017
0
LUX-ZEPLIN (LZ) Technical Design Report
B.J. MountS. Hans…J. Balajthy
The LZ dark matter experiment, described in this Technical Design Report, is a detector to be built at SURF with a design sensitivity to a WIMP-nucleon spin-independent cross section of $3\times10^{-48}$ cm$^2$. This single performance target captures the central contribution: a substantial improvement in direct dark matter search capabilities, with the detector architecture and operations detailed to achieve that goal.
arXivarXiv · · March 27, 2017
0
230
Frequent collaborators
M. Szydagis (41)
C. Chan (40)
E. Druszkiewicz (40)
S. Fiorucci (40)
C. Ghag (40)
A. Lindote (40)
F. Neves (40)
C. Silva (40)
P. Sorensen (40)
X. Bai (39)
M. Horn (38)
W. Ji (37)